Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph

Size: px
Start display at page:

Download "Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph"

Transcription

1 Analysis of USP <7> Residual Solvents using the Agilent 797A Headspace Sampler with the Agilent 79B Gas Chromatograph Application Note Pharmaceuticals Authors Bart Tienpont, Frank David, and Pat Sandra Research Institute for Chromatography Kennedypark B- Kortrijk Belgium Roger L Firor Agilent Technologies, Inc. Centerville Rd Wilmington, DE 9 Abstract USP <7> residual solvents were analyzed by static headspace on the Agilent 797A Headspace Sampler combined with the Agilent 79B Gas Chromatograph. The previously described method performed on an Agilent 79A GC was directly transferred to the 79B GC. Excellent chromatographic performance was achieved at USP <7> specified limits and equivalent results were obtained. This test clearly indicated that methods can be transferred directly from an Agilent 79A GC to the 79B GC without modification.

2 Introduction Residual solvent analysis is a very important quality control procedure performed in the pharmaceutical industry. Sampling is typically performed by static headspace and analysis is done by GC/FID using a dedicated column. Often, a parallel column dual channel analysis by GC/FID or GC/FID/MSD is used. Previously, different configurations were described and tested in terms of repeatability, sensitivity and resolution []. The described dual channel GC/FID method was evaluated on the Agilent 79B GC. The original method was transferred to the GC, without modification. Repeatability, sensitivity, and resolution were all tested using residual solvent solutions in water of Class, Class A, and Class B compounds. Experimental Solutions Three stock solutions of residual solvents in DMSO were used: Residual Solvent Revised Method 7 Class (p/n 9-9), Residual Solvent Revised Method 7 Class A (p/n 9-9), Residual Solvent Revised Method 7 Class B (p/n 9-). These stock solutions were diluted in water to the USP specified limits according to the following scheme: Class solvents. ml stock solution vial plus 9 ml DMSO diluted to ml. ml from step diluted to ml with water ml from step diluted to ml with water. ml from step + ml water in a -ml headspace (HS) vial Table. Residual Solvents, Peak Number, USP Concentration Limits (ppm = mg/kg) and Repeatability (n = ) Obtained by HS-GC-FID on Column (VF) Identity USP limit (ppm) RSD (%) Class,-dichloroethene.,,-trichloroethane,.7 carbon tetrachloride.9 benzene.7,-dichloroethane. Class A methanol,. acetonitrile. dichloromethane. trans-,-dichloroethene,7. cis-,-dichloroethene,7. tetrahydrofuran 7. 7 cyclohexane,. methylcyclohexane,. 9,-dioxane. toluene 9.7 chlorobenzene. ethylbenzene,7., m-xylene, p-xylene,7. o-xylene,7. Class B hexane 9. nitromethane. chloroform.7,-dimethoxyethane. trichloroethene. pyridine. 7 -hexanone. tetralin.7 Class A solvents. ml stock solution vial, diluted to ml. ml from step + ml water in a -ml HS vial Class B solvents. ml stock solution vial, diluted to ml. ml step + ml water in a -ml HS vial The total sample volume was thus constant at ml in -ml headspace vials. Assuming a -mg drug substance sample in the headspace vial, the final residual solvent concentrations correspond to the USP concentration limits (Table ).

3 System Configuration Analyses were performed on an Agilent 797A Headspace Sampler coupled to an Agilent 79B GC. Figure shows the parallel dual column configuration. Experimental conditions Static headspace analysis was performed at C during minutes, according to the previously described method []. Table summarizes the experimental GC conditions. An Ultra Inert liner, p/n 9-9, with glass wool removed was installed in the split/spitless inlet. EPC Figure. Agilent 797A Headspace Sampler SSL. m µm id deactivated fused silica System configuration. Splitter un-purged HP-INNOWax (p/n 99N-) m µm id,. µm df VF-ms (p/n CP9) m µm id,. µm df FID back FID front Table. GC Conditions Conditions Column A Column B Carrier gas Agilent 79A GC m. mm id,. µm VF-ms (p/n CP9) m. mm id,. µm HP-INNOWax (p/n 99N-) Helium, kpa Injection Split/splitless C split ratio : Oven temperature C ( minutes) to C ( minutes) at C/min Detection (both channels) FID, C at Hz

4 Results and Discussion The chromatograms obtained for, respectively, Class, Class A, and Class B residual solvents are given in Figures. Peaks in the chromatograms can be identified by referring to Table. The obtained separations are very similar to those obtained previously on a 79A GC []. Elution order, resolution, and sensitivity are equivalent.. VF-ms. HP-INNOWax. 7 min,. 7 min Figure. Dual channel GC/FID profile of Class residual solvents at USP specification limits using an Agilent 797A Headspace Sampler and an Agilent 79B GC (peak identification: see Table ). VF-ms 7, HP-INNOWax 7 9, 9 min.9 min Figure. Dual channel GC/FID profile of Class A residual solvents at USP specification limits using an Agilent 797A Headspace Sampler and an Agilent 79B GC (peak identification: see Table ).

5 Note that Class solvents benzene and,-dichloroethene are baseline separated on the VF- column. The signal-to-noise (S/N) ratio for class solvents was for,-dichloroethene, for,,-trichloroethene, for carbon tetrachloride, for benzene, and 9 for,-dichloroethane; all clearly better than the required S/N >. These values were obtained with parallel column detection (: split between columns). Values using a single column would be x higher. The analysis was repeated six times, and the RSDs obtained on the VF- column are listed in Table. The average RSD was.%, which is excellent for static headspace sampling at these concentrations. This level of performance can be attributed to precise EPC controlled vial sampling, complete inert sample path, stable uniform thermal zones, and Capillary Flow Technology (CFT) devices. VF-ms 7 min HP-INNOWax 7 min Figure. Dual channel GC/FID profile of Class B residual solvents at USP specification limits using an Agilent 797A Headspace Sampler and an Agilent 79B GC (peak identification: see Table ).

6 Conclusions Methods developed for USP <7> residual solvent analysis on an Agilent 797A Headspace sampler combined with an Agilent 79A GC can be transferred to an Agilent 79B GC with preserved resolution, sensitivity, and repeatability. Excellent results were obtained at USP <7> specified limit concentrations for the three classes of residual solvents. References. R. L. Firor, Analysis of USP<7> residual solvents with improved repeatability using the Agilent 797A Headspace Sampler, Agilent Technologies application note 99-7EN, August.. USP -NF 7, General chapter USP <7>, Organic volatile impurities, US Pharmacopeia, Rockville, MD, /9 For More Information These data represent typical results. For more information on our products and services, visit our Web site at Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., Printed in the USA January 9, 99-EN

Prefractionator for Reliable Analysis of the Light Ends of Crude Oil and other Petroleum Fractions

Prefractionator for Reliable Analysis of the Light Ends of Crude Oil and other Petroleum Fractions Prefractionator for Reliable Analysis of the Light Ends of Crude Oil and other Petroleum Fractions Application Note Hydrocarbon Processing Author Roger L Firor Agilent Technologies, Inc. 2850 Centerville

More information

Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application

Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application Food Authors Frank David Research Institute for Chromatography Pres. Kennedypark

More information

Improving GC-MS Method Robustness and Cycle Times Using Capillary Flow Technology and Backflushing

Improving GC-MS Method Robustness and Cycle Times Using Capillary Flow Technology and Backflushing Improving GC-MS Method Robustness and Cycle Times Using Capillary Flow Technology and Backflushing Application Note Environmental Author Chris Sandy Agilent Technologies, Inc. UK and Ireland Sales Headquarters

More information

Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D7504 on the Agilent 8890 GC System

Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D7504 on the Agilent 8890 GC System Application Note Petrochemicals Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D50 on the Agilent 0 GC System Authors Jie Pan, Lukas Wieder,

More information

Environmental Volatiles using a Headspace-GC/MSD Analyzer

Environmental Volatiles using a Headspace-GC/MSD Analyzer Environmental Volatiles using a Headspace-GC/MSD Analyzer Application Note Environmental Author Mike Szelewski Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19809-1610 USA Abstract The

More information

Analysis of Semivolatiles by GC/FID using the Ultra Inert Inlet Liners with Wool

Analysis of Semivolatiles by GC/FID using the Ultra Inert Inlet Liners with Wool Analysis of Semivolatiles by GC/FID using the Ultra Inert Inlet Liners with Wool Application Note Environmental Authors Limian Zhao and Bill Wilson Agilent Technologies, Inc. 2850 Centerville Road Wilmington,

More information

A New Horizon of Performance Agilent G1888 Network Headspace Sampler

A New Horizon of Performance Agilent G1888 Network Headspace Sampler A New Horizon of Performance Agilent G1888 Network Headspace Sampler Full system integration Extended sample capacity Built-in ease-of-use Uncompromised reliability The Steps To Confidence From sample

More information

Organohalide Pesticides in Water by GC/µECD with Agilent J&W DB-CLP1 and DB-CLP2

Organohalide Pesticides in Water by GC/µECD with Agilent J&W DB-CLP1 and DB-CLP2 Organohalide Pesticides in Water by GC/µECD with Agilent J&W DB-CLP and DB-CLP Application Note Environmental Authors Doris Smith and Ken Lynam Agilent Technologies, Inc. Abstract Organohalide pesticides

More information

Direct Injection of Fish Oil for the GC-ECD Analysis of PCBs: Results Using a Deans Switch With Backflushing. Application. Author.

Direct Injection of Fish Oil for the GC-ECD Analysis of PCBs: Results Using a Deans Switch With Backflushing. Application. Author. Direct Injection of Fish Oil for the GC-ECD Analysis of PCBs: Results Using a Deans Switch With Backflushing Application Environmental and Pharmaceutical Author Philip L. Wylie Agilent Technologies, Inc.

More information

A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water

A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water Application Note Environmental Authors Min Cai and Yun Zou Agilent Technologies Co. Ltd, 412 Ying Lun Road Waigaoqiao

More information

EPA Method 524 for Determination of VOCs in Drinking Water Using Agilent 5975T LTM GC/MSD with Static Headspace

EPA Method 524 for Determination of VOCs in Drinking Water Using Agilent 5975T LTM GC/MSD with Static Headspace EPA Method 524 for Determination of VOCs in Drinking Water Using Agilent 5975T LTM GC/MSD with Static Headspace Application Note Environmental Authors Xiaohua Li Agilent Technologies (Shanghai) Co., Ltd.

More information

Agilent Consumables Improve Performance with Shimadzu GC/MS

Agilent Consumables Improve Performance with Shimadzu GC/MS Agilent Consumables Improve Performance with Shimadzu GC/MS Application Note Environmental & Food Safety Author Ken Lynam Agilent Technologies, Inc. Abstract Leak-free performance over 150 heat cycles

More information

METHOD TRANSLATION OF HJ FOR INTUVO

METHOD TRANSLATION OF HJ FOR INTUVO METHOD TRANSLATION OF HJ679-2013 FOR INTUVO Translating a 530 µm id Column Method to 250 µm or 320 µm column Methods for the Agilent Intuvo 9000 GC Introduction HJ method 679-2013 describes the determination

More information

A Direct Column-Performance Comparison for Rapid Contract Laboratory Program (CLP) Pesticide Analysis. Application. Authors. Abstract.

A Direct Column-Performance Comparison for Rapid Contract Laboratory Program (CLP) Pesticide Analysis. Application. Authors. Abstract. A Direct Column-Performance Comparison for Rapid Contract Laboratory Program (CLP) Pesticide Analysis Application Environmental Authors Ken Lynam and John W. Henderson, Jr. Agilent Technologies, Inc. 2850

More information

Analysis of Permanent Gases and Extended Hydrocarbons in Natural Gas and Natural Gas Liquids by Capillary Gas Chromatography

Analysis of Permanent Gases and Extended Hydrocarbons in Natural Gas and Natural Gas Liquids by Capillary Gas Chromatography Analysis of Permanent Gases and Extended Hydrocarbons in Natural Gas and Natural Gas Liquids by Capillary Gas Chromatography Application Note Natural Gas Analyzer Authors Shannon Coleman and Kelly Beard

More information

Contract Laboratory Program (CLP) Pesticide Analysis with 0.18 mm ID High-Efficiency GC Columns Utilizing Helium Carrier Gas. Application.

Contract Laboratory Program (CLP) Pesticide Analysis with 0.18 mm ID High-Efficiency GC Columns Utilizing Helium Carrier Gas. Application. Contract Laboratory Program (CLP) Pesticide Analysis with 0.8 mm ID High-Efficiency GC Columns Utilizing Helium Carrier Gas Application Environmental Authors Ken Lynam and William Long Agilent Technologies,

More information

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE.

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE Authors: DANI Instruments Inc 257 Simarano Drive Marlborough, MA 01752 Ph: 508-281-6232

More information

Improved Gas Chromatograph Method for the Analysis of Trace Hydrocarbon Impurities in 1, 3-Butadiene

Improved Gas Chromatograph Method for the Analysis of Trace Hydrocarbon Impurities in 1, 3-Butadiene Improved Gas Chromatograph Method for the Analysis of Trace Hydrocarbon Impurities in 1, 3-Butadiene Application Note Hydrocarbon processing industry Author Chunxiao Wang Agilent Technologies (Shanghai)

More information

US EPA Method Atomx XYZ and Agilent 7890B GC/5977A MS

US EPA Method Atomx XYZ and Agilent 7890B GC/5977A MS Application Note Environmental US EPA Method 524.3 Atomx XYZ and Agilent 7890B GC/5977A MS Author Amy Nutter Applications Chemist, Teledyne Tekmar Abstract US EPA Method 524.3 was used to determine the

More information

The Use Of Automated Backflush on the 7890A/5975A GC-MS System. Application. Setup Example Using Biomarkers. Authors. Abstract.

The Use Of Automated Backflush on the 7890A/5975A GC-MS System. Application. Setup Example Using Biomarkers. Authors. Abstract. The Use Of Automated Backflush on the 7890A/5975A GC-MS System Setup Example Using Biomarkers Application Hydrocarbon Processing Authors Courtney Milner and Russell Kinghorn BST International 41 Greenaway

More information

N E W S L E T T E R F R O M TO S H V I N A N A LY T I C A L P V T. LT D. JULY 2013

N E W S L E T T E R F R O M TO S H V I N A N A LY T I C A L P V T. LT D. JULY 2013 N E W S L E T T E R F R O M TO S H V I N A N A LY T I C A L P V T. LT D. JULY 213 Analysis of Residual Pesticides in Foods Using Twin Line GC MS To obtain highly reliable data from analyzing residual pesticides

More information

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau Development, validation, and comparison of an HPLC method to analyze paracetamol and related impurities according to the European Pharmacopoeia (EP) and USP using the Agilent 1120 Compact LC and the Agilent

More information

Chlorinated Solvents and Disinfection By-Product Analysis Using Agilent J&W HP-1ms Ultra Inert and DB-1301 Capillary GC Columns

Chlorinated Solvents and Disinfection By-Product Analysis Using Agilent J&W HP-1ms Ultra Inert and DB-1301 Capillary GC Columns Chlorinated Solvents and Disinfection By-Product Analysis Using Agilent J&W HP-1ms Ultra Inert and DB-1301 Capillary GC Columns Application Note Environmental Authors Doris Smith and Ken Lynam Agilent

More information

USEPA Methods and 8021B using the Eclipse Purge-and-Trap (P&T) Sample Concentrator and PID/ELCD Tandem Detectors

USEPA Methods and 8021B using the Eclipse Purge-and-Trap (P&T) Sample Concentrator and PID/ELCD Tandem Detectors Application Note 31630508 USEPA Methods 502.2 and 8021B using the Eclipse Purge-and-Trap (P&T) Sample Concentrator and PID/ELCD Tandem Detectors Keywords Volatile Organic Compounds (VOCs) Purge-and-Trap

More information

USEPA Methods and 8021B using the Eclipse Purge-and-Trap (P&T) Sample Concentrator and PID/ELCD Tandem Detectors

USEPA Methods and 8021B using the Eclipse Purge-and-Trap (P&T) Sample Concentrator and PID/ELCD Tandem Detectors Application Note 31630710 USEPA Methods 502.2 and 8021B using the Eclipse Purge-and-Trap (P&T) Sample Concentrator and PID/ELCD Tandem Detectors Keywords Volatile Organic Compounds (VOCs) Purge-and-Trap

More information

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools Application Note Abstract The Commonwealth of Massachusetts Department of Environmental Protection

More information

Thermal Desorption Technical Support Note 87: A cryogen-free method for monitoring trace greenhouse gases in air. Key Words:

Thermal Desorption Technical Support Note 87: A cryogen-free method for monitoring trace greenhouse gases in air. Key Words: Thermal Desorption Technical Support Note 87: A cryogen-free method for monitoring trace greenhouse gases in air Key Words: Trace greenhouse gases, Kyoto Protocol, CFCs, HCFCs, UNITY 2, CIA 8, air toxics,

More information

Reduced carryover and increased reproducibility in the analysis of cold pressed pink grapefruit essential oil

Reduced carryover and increased reproducibility in the analysis of cold pressed pink grapefruit essential oil Application Note Food Testing and Agriculture Reduced carryover and increased reproducibility in the analysis of cold pressed pink grapefruit essential oil Using an Agilent J&W DB-HeavyWAX GC column Author

More information

Fast GC Analyses of Volatiles

Fast GC Analyses of Volatiles 6 Fast GC Analyses of Volatiles Michael D. Buchanan mike.buchanan@sial.com Introduction The primary aim of Fast GC is to maintain (compared to conventional GC) sufficient resolving power in a shorter time.

More information

US EPA Method 8260 with the Atomx XYZ and the Thermo Scientific TRACE 1310 GC and ISQ MS

US EPA Method 8260 with the Atomx XYZ and the Thermo Scientific TRACE 1310 GC and ISQ MS APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1803 P+T VOC ENV US EPA Method 8260 with the Atomx XYZ and the Thermo Scientific TRACE 1310 GC and ISQ MS Amy Nutter, Applications Chemist; Teledyne Tekmar Page

More information

Semivolatile Analysis with Specially Designed Agilent J&W DB-UI 8270D Columns

Semivolatile Analysis with Specially Designed Agilent J&W DB-UI 8270D Columns Semivolatile Analysis with Specially Designed Agilent J&W DB-UI 8270D Columns Application Note Environmental Author Ken Lynam Agilent Technologies, Inc. Abstract Excellent peak shapes and chromatographic

More information

Protocol for Quantitative Determination of Residual Solvents in Cannabis Concentrates Prepared by: Amanda Rigdon, May 23 rd, 2016

Protocol for Quantitative Determination of Residual Solvents in Cannabis Concentrates Prepared by: Amanda Rigdon, May 23 rd, 2016 Protocol for Quantitative Determination of Residual Solvents in Cannabis Concentrates Prepared by: Amanda Rigdon, May 23 rd, 2016 1.0 Method background: This method employs full evaporation technique headspace

More information

Gas Chromatography SSI-GC-003

Gas Chromatography SSI-GC-003 Gas Chromatography SSI-GC-003 Trace Oxygenated Hydrocarbons in Liquid Hydrocarbon Streams by Multidimensional GC Introduction It has been widely accepted that oxygenates are related to corrosion and fouling

More information

Quantitative determination of residual 2-(2-chloroethoxy) ethanol (CEE) in quetiapine fumarate by gas chromatogaraphy

Quantitative determination of residual 2-(2-chloroethoxy) ethanol (CEE) in quetiapine fumarate by gas chromatogaraphy Advances in Bioscience and Biotechnology, 2010, 1, 367-371 doi:10.4236/abb.2010.15049 Published Online December 2010 (http://www.scirp.org/journal/abb/). Quantitative determination of residual 2-(2-chloroethoxy)

More information

Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e 1

Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e 1 Application Note US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e 1 Abstract US EPA Method 8260 in conjunction

More information

Agilent Ultimate Plus Fused Silica Tubing

Agilent Ultimate Plus Fused Silica Tubing Agilent Ultimate Plus Fused Silica Tubing Technical Overview Introduction Deactivated fused silica tubing is widely used for guard columns, transfer lines, or long retention gaps in GC and GC/MS applications

More information

Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1

Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1 Application Note US EPA Method 524.3 with the Tekmar Lumin P & T Concentrator and Agilent 7890B GC and 5977A MSD System Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1 Abstract US EPA Method

More information

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Application Note US EPA Method 524.4 with the Tekmar Lumin P & T Concentrator and Agilent 7890B GC and 5977A MSD System Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Abstract US EPA Method

More information

Chromatography 2015, 36, Technical Note

Chromatography 2015, 36, Technical Note Technical Note Development and Validation of an Analytical Method for Simultaneous Quantitation of Organic Volatile Impurities in Technical-Grade Active Ingredients of Pesticides and Agrochemicals by Headspace

More information

Using Alternative Carrier Gas for US EPA Application Note. Abstract. Introduction. Experimental-Instrument Conditions

Using Alternative Carrier Gas for US EPA Application Note. Abstract. Introduction. Experimental-Instrument Conditions Using Alternative Carrier Gas for US EPA 524.3 Application Note Abstract Due to regional shortages and increasing costs of helium, the preferred carrier gas in gas chromatography, alternative carrier gas

More information

Analyze more samples. faster. while maintaining resolution. NEW Agilent J&W High Efficiency Capillary GC Columns

Analyze more samples. faster. while maintaining resolution. NEW Agilent J&W High Efficiency Capillary GC Columns faster Analyze more samples while maintaining resolution. NEW Agilent J&W High Efficiency Capillary GC Columns We need to run twice as many samples in the same amount of time with the same resources. I

More information

Drinking Water Semivolatiles Analysis using the 6890N/5975B inert GC/MSD. Application. Author. Abstract. Instrument Operating Parameters.

Drinking Water Semivolatiles Analysis using the 6890N/5975B inert GC/MSD. Application. Author. Abstract. Instrument Operating Parameters. Drinking Water Semivolatiles Analysis using the 6890N/5975B inert GC/MSD Application Author Mike Szelewski Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808 USA Abstract The analysis

More information

Volatile Organic Compounds in Solids PBM

Volatile Organic Compounds in Solids PBM Organics Revision Date: Aug 15, 2014 Volatile Organic Compounds in Solids PBM Parameter Analytical Method Introduction Method Summary Parameter Applicability, MDLs Volatile Organic Compounds (VOCs) in

More information

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations SCION GC Series The Gas Chromatographers Choice for Separations Innovation in Gas Chromatography Scion Instrument s tradition of innovation and product reliability have combined to create the next generation

More information

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations SCION GC Series The Gas Chromatographers Choice for Separations Innovation in Gas Chromatography Scion Instrument s tradition of innovation and product reliability have combined to create the next generation

More information

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run Application Note Author Jessica Westland Agilent Technologies, Inc. Abstract A selected target compound list of 195 various pesticides

More information

US EPA Method 8260 With the Tekmar Lumin and the Agilent 7890B GC/5977A MS

US EPA Method 8260 With the Tekmar Lumin and the Agilent 7890B GC/5977A MS Application Note US EPA Method 8260 With the Tekmar Lumin and the Agilent 7890B GC/5977A MS Author Roger Bardsley Applications Chemist, Teledyne Tekmar Abstract US EPA Method 8260 is used primarily by

More information

Two Headspace Solutions for the Analysis of Dissolved Gases in Water by Method RSKSOP-175

Two Headspace Solutions for the Analysis of Dissolved Gases in Water by Method RSKSOP-175 Two Headspace Solutions for the Analysis of Dissolved Gases in Water by Method RSKSOP-175 Application Note Abstract Dissolved gas analysis has been performed using a simplified headspace method following

More information

Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D*

Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D* Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D* UCT Products: ECUNIPAH (ENVIRO-CLEAN Universal PAH/DRO 2000 mg/83 ml cartridge) Method Summary Method 8015D may be used

More information

Chromatography Applications and Technology

Chromatography Applications and Technology Using Flow Switching Devices to Improve GC-MS Productivity in Environmental Analyses Andrew Tipler, Jonas Bjorklund, William Goodman and Lee Marotta, Chromatography Applications and Technology Group, PerkinElmer

More information

Determination of Volatile Organic Compounds (VOCs) present in the interiors of car by using GCMS/MS with static and dynamic headspace

Determination of Volatile Organic Compounds (VOCs) present in the interiors of car by using GCMS/MS with static and dynamic headspace PO-CON44E Determination of Volatile Organic Compounds (VOCs) present in the interiors of car by using GCMS/MS ASMS 20 ThP 138 Sanket Chiplunkar, Ankush Bhone, Durvesh Sawant, Dheeraj Handique, Prashant

More information

Capillary GC Troubleshooting: a Practical Approach

Capillary GC Troubleshooting: a Practical Approach Capillary GC Troubleshooting: a Practical Approach Katherine Stenerson Gas Separations R&D Supelco, Supelco Park, Bellefonte, PA 16823 1999 Sigma-Aldrich Co. Outline Basic Troubleshooting Strategy Preventing

More information

Performance Characteristics of the Agilent 1220 Infinity Gradient LC system

Performance Characteristics of the Agilent 1220 Infinity Gradient LC system Performance Characteristics of the Agilent 122 Infinity Gradient LC system An integrated LC system for conventional LC and UHPLC Technical Overview 7 5 4 3 2 1.5 1 1.5 2 2.5 3 Introduction The Agilent

More information

Certified Reference Material - Certificate of Analysis

Certified Reference Material - Certificate of Analysis Certified Reference Material - Certificate of Analysis T-32 Page 1 of 7 (-)- 8 -THC, Primary Standard Catalog Number: T-32 Lot: Expiration: Description: October 22 (-)- 8 -THC in Methanol. Packaging: Solution

More information

Determination of Volatile Organic Compounds (VOCs) in Various Drinking Water Sources by GC/MS

Determination of Volatile Organic Compounds (VOCs) in Various Drinking Water Sources by GC/MS Determination of Volatile Organic Compounds (VOCs) in Various Drinking Water Sources by GC/MS Application Note Abstract Consumers have become increasingly concerned with the quality of their drinking water.

More information

Determination of Asarinin in Xixin (Asari Radix Et Rhizoma)

Determination of Asarinin in Xixin (Asari Radix Et Rhizoma) Deteration of Asarinin in Xixin (Asari Radix Et Rhizoma) Using Agilent InfinityLab Poroshell 2 EC-C8,.9 µm Columns Application Note Pharmaceutical Author Rongjie Fu Agilent Technologies Shanghai Abstract

More information

Fast On-Site Mine Safety Analysis by the Agilent 490 Micro GC

Fast On-Site Mine Safety Analysis by the Agilent 490 Micro GC Fast On-Site Mine Safety Analysis by the Agilent 490 Micro GC Application Note Micro Gas Chromatography, Mine gas analysis, Mine safety Authors Darren Brady Safety in Mines Testing and Research Station

More information

Headspace Samplers. HS-20 Series C146-E209D

Headspace Samplers. HS-20 Series C146-E209D Headspace Samplers HS-20 Series C146-E209D HS-20 Series of Headspace Samplers A Revolutionary System Aimed at Performance and Ease of Use The HS-20 Series is the optimal solution for volatile component

More information

High-Throughput LC/MS Purification of Pharmaceutical Impurities

High-Throughput LC/MS Purification of Pharmaceutical Impurities High-Throughput LC/MS Purification of Pharmaceutical Impurities Application Note Small Molecule Pharmaceuticals Author Florian Rieck Agilent Technologies, Inc. Waldbronn, Germany Abstract Legal regulations

More information

Fast Analysis of Environmental Phenols with Agilent Poroshell 120 EC-C18 Columns

Fast Analysis of Environmental Phenols with Agilent Poroshell 120 EC-C18 Columns Fast Analysis of Environmental Phenols with Agilent Poroshell 120 EC-C18 Columns Application Note Environmental Authors William J. Long and Anne E. Mack Agilent Technologies, Inc. 2850 Centerville Road

More information

MARKET FOCUSED - environmental ORGANOCHLORINE PESTICIDES

MARKET FOCUSED - environmental ORGANOCHLORINE PESTICIDES www.sge.com TECHNICAL ARTICLE MARKET FOCUSED - environmental ORGANOCHLORINE PESTICIDES With the widespread use of pesticides, especially over the last 40 years, pesticide analysis is one of the most universal

More information

AppNote 8/2014. Automated Ultrasonic Extraction of a Plant Material Using the Gerstel MPS Dual Head WorkStation KEYWORDS ABSTRACT

AppNote 8/2014. Automated Ultrasonic Extraction of a Plant Material Using the Gerstel MPS Dual Head WorkStation KEYWORDS ABSTRACT AppNote 8/2014 Automated Ultrasonic Extraction of a Plant Material Using the Gerstel MPS Dual Head WorkStation Melissa Dunkle, Christophe Devos, Bart Tienpont, Frank David, Pat Sandra, Koen Sandra Research

More information

The Use of High Resolution Accurate Mass GC/Q-TOF and Chemometrics in the Identification of Environmental Pollutants in Wastewater Effluents

The Use of High Resolution Accurate Mass GC/Q-TOF and Chemometrics in the Identification of Environmental Pollutants in Wastewater Effluents The Use of High Resolution Accurate Mass GC/Q-TOF and Chemometrics in the Identification of Environmental Pollutants in Wastewater s Application Note Environmental Authors Anthony Gravell and Praveen Kutty

More information

Methods for Increased Sample Throughput with Dirty Samples

Methods for Increased Sample Throughput with Dirty Samples Methods for Increased Sample Throughput with Dirty Samples Alan D Broske, Limian Zhao, and William H. Wilson Agilent Technologies, Inc. 1 Introduction GC inlet liner impacts sample transfer to the GC column

More information

GC Troubleshooting. Frank Michel, Katherine K. Stenerson T HCE

GC Troubleshooting. Frank Michel, Katherine K. Stenerson T HCE GC Troubleshooting Frank Michel, Katherine K. Stenerson T404077 HCE GC Troubleshooting: Topics Basic Troubleshooting Strategy Preventing Problems Identifying Common Problems Recommended Reading Discussion

More information

Appendix A. Soil Analytical Data (appears on CD only) A-1: Soil Analytical Results Arsenic. A-2: Soil Analytical Results Volatile Organic Compounds

Appendix A. Soil Analytical Data (appears on CD only) A-1: Soil Analytical Results Arsenic. A-2: Soil Analytical Results Volatile Organic Compounds Appendix A Soil Analytical Data (appears on CD only) A-1: Soil Analytical Results Arsenic A-2: Soil Analytical Results Volatile Organic Compounds A-3: Soil Analytical Results Herbicides CORPORATION - MIDDLEPORT,

More information

Standard Test Methods for Aromatics in Mineral Spirits by Gas Chromatography 1

Standard Test Methods for Aromatics in Mineral Spirits by Gas Chromatography 1 Designation: D 3257 01 Standard Test Methods for Aromatics in Mineral Spirits by Gas Chromatography 1 This standard is issued under the fixed designation D 3257; the number immediately following the designation

More information

PAL SPME Fibers Optimized for Automation

PAL SPME Fibers Optimized for Automation PAL SPME Fibers Optimized for Automation PAL SPME Fiber Since its introduction by Pawliszyn et al. (ref. 1) Solid Phase Micro Extraction (SPME) has seen a tremendous development. SPME is a very effective

More information

PAL SPME Fibers Optimized for Automation

PAL SPME Fibers Optimized for Automation PAL SPME Fibers Optimized for Automation PAL SPME Fiber Since its introduction by Pawliszyn et al. (ref. 1) Solid Phase Micro Extraction (SPME) has seen a tremendous development. SPME is a very effective

More information

Application Note. Authors. Abstract. Introduction. Pharmaceutical

Application Note. Authors. Abstract. Introduction. Pharmaceutical Scalability of Agilent s Across HPLC and UHPLC Instruments Application Note Pharmaceutical Authors Anne E. Mack, William J. Long Agilent Technologies, Inc. 2850 Centerville Road, Wilmington, DE 19808 USA

More information

Characterize mab Charge Variants by Cation-Exchange Chromatography

Characterize mab Charge Variants by Cation-Exchange Chromatography Characterize mab Charge Variants by Cation-Exchange Chromatography Application Note Biologics and Biosimilars Authors Isabel Vandenheede, Emmie Dumont, Pat Sandra, and Koen Sandra Research Institute for

More information

GC Method Development

GC Method Development GC Method Development Simon Jones Application Engineer April 13, 2010 What to Consider The Sample Method of injection Inlet Detector Carrier Gas Column COMPOUND REQUIREMENTS FOR GC Only 10-20% of all compounds

More information

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER ENVIRONMENTAL ANALYSIS ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER Solutions for Your Analytical Business

More information

Gas Chromatography Assignment Chem 543/443

Gas Chromatography Assignment Chem 543/443 Gas Chromatography Assignment Chem 543/443 1. Introduction Capillary gas chromatography (GC) is one of the most popular analytical techniques used in today s research. Its popularity is mainly due to efficient

More information

Analysis of Atrazine in Drinking Water at the ppb Level Using New Agilent Reversed Phase LC Columns. Application. Author. Abstract.

Analysis of Atrazine in Drinking Water at the ppb Level Using New Agilent Reversed Phase LC Columns. Application. Author. Abstract. Analysis of Atrazine in Drinking Water at the ppb Level Using ew Agilent Reversed Phase LC Columns Application Environmental Author Rongjie Fu Agilent Technologies, Inc. 412 Ying Lun Road Pu Dong, Shanghai

More information

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS Authors: Conor Smith, Doug Fryer United Science Corp. 15911 Furuby Rd. Center City, MN 55012 USA Abstract

More information

Evaluating Inert Flow Path Components and Entire Flow Path for GC/MS/MS Pesticide Analysis

Evaluating Inert Flow Path Components and Entire Flow Path for GC/MS/MS Pesticide Analysis Evaluating Inert Flow Path Components and Entire Flow Path for GC/MS/MS Pesticide Analysis Application Note Food Testing & Agriculture Author Limian Zhao Agilent Technologies, Inc. Abstract Flow path inertness

More information

Volatile Organic Compounds in Solids PBM

Volatile Organic Compounds in Solids PBM Lab Manual Section Revision Date: Mar 15, 2016 Volatile Organic Compounds in Solids PBM Parameter Analytical Method Introduction Method Summary MDL(s) and EMS Analyte Codes Volatile Organic Compounds (VOCs)

More information

Method Translation in Liquid Chromatography

Method Translation in Liquid Chromatography Method Translation in Liquid Chromatography Technical Overview Abstract Ronald E. Majors Agilent Technologies, Inc. 2850 Centerville Rd Wilmington, DE 19808 USA With the recent emphasis on high performance

More information

Reversed-phase Separation of Intact Monoclonal Antibodies Using Agilent ZORBAX Rapid Resolution High Definition 300SB-C8 1.

Reversed-phase Separation of Intact Monoclonal Antibodies Using Agilent ZORBAX Rapid Resolution High Definition 300SB-C8 1. Reversed-phase Separation of Intact Monoclonal Antibodies Using Agilent ZORBAX Rapid Resolution High Definition 3SB-C8 1.8 µm Column Application Note Biopharmaceuticals Authors James Martosella and Phu

More information

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations SCION GC Series The Gas Chromatographers Choice for Separations Innovation in Gas Chromatography Bruker s Scion Instrument s long tradition long of tradition innovation of innovation and product and reliability

More information

Installation, Care and Maintenance of Capillary Gas Chromatography Columns. Mark Sinnott Application Engineer January 2015 Happy New Year!

Installation, Care and Maintenance of Capillary Gas Chromatography Columns. Mark Sinnott Application Engineer January 2015 Happy New Year! Installation, Care and Maintenance of Capillary Gas Chromatography Columns Mark Sinnott Application Engineer January 2015 Happy New Year! Installation, Care and Maintenance of Capillary Gas Chromatography

More information

Improving Productivity in Your Environmental and Food Testing Labs with Agilent 7890A/5975C GC/MS System

Improving Productivity in Your Environmental and Food Testing Labs with Agilent 7890A/5975C GC/MS System Improving Productivity in Your Environmental and Food Testing Labs with Agilent 789A/5975C GC/MS System Mike Szelewski Senior Applications Chemist Page 1 Overview Capillary Flow Devices A family of tools

More information

3-IN-1 TECHNOLOGY Highest Inertness Lowest Bleed Exceptional Reproducibility

3-IN-1 TECHNOLOGY Highest Inertness Lowest Bleed Exceptional Reproducibility 3-IN-1 TECHNLGY Highest Inertness Lowest Bleed Exceptional Reproducibility Lower Detection Limits with Ground-Breaking Column Technology Rxi technology unifies outstanding inertness, low bleed, and high

More information

Application Note. Abstract. Authors. Environmental

Application Note. Abstract. Authors. Environmental Maintaining Compound Retention Times with the Backflush Enabled Pressure Controlled Tee Configuration for Agilent 7890A GCs with Agilent 5975 Series MSD and Agilent 7000 Series Triple Quadrupole MS Systems

More information

Certified Reference Material - Certificate of Analysis

Certified Reference Material - Certificate of Analysis Certified Reference Material - Certificate of Analysis Page 1 of 9 Fluconazole- 13 C 3, Primary Standard Catalog Number: Lot: Retest: July 2015 Description: Fluconazole- 13 C 3 in Methanol Packaging: Solution

More information

The Analysis of Oxygenates by EPA Method 8260

The Analysis of Oxygenates by EPA Method 8260 The Analysis of Oxygenates by EPA Method 8260 Chris M. English, Frank L. Dorman & Gary Stidsen. (Restek Corporation, 110 Benner Circle, Bellefonte, PA 16823) Abstract Gasoline and other fossil fuels are

More information

Analysis of styrene leached from polystyrene cups using GCMS coupled with Headspace (HS) sampler

Analysis of styrene leached from polystyrene cups using GCMS coupled with Headspace (HS) sampler PO-CON464E Analysis of styrene leached from polystyrene cups using GCMS coupled with Headspace (HS) sampler ASMS 204 TP763 Ankush Bhone (), Dheeraj Handique (), Prashant Hase (), Sanket Chiplunkar (),

More information

Separation of Recombinant Human Erythropoietin (repo) Using Agilent Bio SEC-3

Separation of Recombinant Human Erythropoietin (repo) Using Agilent Bio SEC-3 Separation of Recombinant Human Erythropoietin (repo) Using Agilent Bio SEC-3 Application Note BioPharma Authors Phu T Duong and James Martosella Agilent Technologies, Inc. 285 Centerville Rd, Wilmington,

More information

EPA 8330A Analysis of Explosives Using Agilent Poroshell 120 EC-CN and EC-C18 Columns

EPA 8330A Analysis of Explosives Using Agilent Poroshell 120 EC-CN and EC-C18 Columns EPA A Analysis of Explosives Using Agilent Poroshell EC-CN and EC-C Columns Application Note Environmental Author Anne Mack Agilent Technologies, Inc. Abstract A group of nitroaromatics and nitraes was

More information

GC Method Developement. Simon Jones GC Application Engineer GC Columns and Consumables

GC Method Developement. Simon Jones GC Application Engineer GC Columns and Consumables GC Method Developement Simon Jones GC Application Engineer GC Columns and Consumables What to Consider The Sample Method of injection Inlet Detector Carrier Gas Column COMPOUND REQUIREMENTS FOR GC Only

More information

Simplifying Methods Transfer: Novel Tools for Replicating Your Established Methods on an ACQUITY Arc System

Simplifying Methods Transfer: Novel Tools for Replicating Your Established Methods on an ACQUITY Arc System Simplifying Methods Transfer: Novel Tools for Replicating Your Established Methods on an ACQUITY Arc System Paula Hong, Richard Andrews, Peyton C. Beals, and Patricia R. McConville Waters Corporation,

More information

Certified Reference Material - Certificate of Analysis

Certified Reference Material - Certificate of Analysis Certified Reference Material - Certificate of Analysis S(+)-Methamphetamine, Primary Standard M-020 Page 1 of 7 Catalog Number: M-020 Lot: Expiration: Description: Packaging: Storage: Shipping: Intended

More information

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications TECHNICAL BRIEF Gas Chromatography/ Mass Spectrometry The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications C 14 scans Introduction As gas chromatography

More information

Certified Reference Material - Certificate of Analysis

Certified Reference Material - Certificate of Analysis Certified Reference Material - Certificate of Analysis T-005 Page 1 of 7 Catalog Number: T-005 Lot: (-)- 9 -THC, Primary Standard CH 3 OH Expiration: Description: April 2019 (-)- 9 -THC in Methanol. H

More information

Improved Sensitivity with the Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD)

Improved Sensitivity with the Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD) Improved Sensitivity with the Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD) Technical Overview Author Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany Abstract This Technical

More information

HYDROGEN AS A CARRIER GAS. Gas Chromatography new frontiers: can Hydrogen substitute Helium?

HYDROGEN AS A CARRIER GAS. Gas Chromatography new frontiers: can Hydrogen substitute Helium? HYDROGEN AS A CARRIER GAS Gas Chromatography new frontiers: can Hydrogen substitute Helium? Manufacturing UHP gas generators for lab analysis since 1979, CLAIND is seating in Lenno, on Como Lake, where

More information

Electron Capture Detector for GC-2010 Plus

Electron Capture Detector for GC-2010 Plus Electron Capture Detector for GC-2010 Plus C180-E080 The World's Highest Level of Durability and Performance for a Capillary ECD Electron Capture Detector Novel Contact Free Technology was incorporated

More information

Agilent 490 Micro GC Biogas Analyzers

Agilent 490 Micro GC Biogas Analyzers Agilent 490 Micro GC Biogas Analyzers User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by any means (including electronic

More information

TurboMatrix Headspace and Headspace Trap Samplers

TurboMatrix Headspace and Headspace Trap Samplers S P E C I F I C A T I O N S Gas Chromatography TurboMatrix Headspace and Headspace Trap Samplers For added flexibility to meet your laboratory s changing requirements, five different PerkinElmer TurboMatrix

More information