Construction Heater. Pilot Light and Electronic Ignition. Parts Identification Guide

Size: px
Start display at page:

Download "Construction Heater. Pilot Light and Electronic Ignition. Parts Identification Guide"

Transcription

1 Construction Heater Pilot Light and Electronic Ignition Parts Identification Guide

2 Table of Contents PARTS IDENTIFICATION GUIDE Tradesman Portable Forced Section/Page CP100C E E E CP100A CP100B CP155A CP155B CP155C Non-Diagnostic CP155C Diagnostic CP380A CP380B CP304D CP400A CP400B Non-Diagnostic CP400B Diagnostic Workman & Norseman Convection Heaters 30B A CV CV100 (Low Pressure Natural Gas) CV Jet, Twin Jet & Big Bertha Circulating Construction Heaters Foreman Portable Unit Heaters CS080C CS080D CS080E CS170C CS170D

3 Table of Contents (Cont.) Premier Series and other Tent Heaters 86A B A B CT080A CT080B CT170A CT170B TS080C TS080D TS080E TS170C TS170D TS350A Tradesman Kerosene Heaters K K K K K Service Parts, Kits & Accessories Warranty Guidelines

4 Parts Identification Guide The parts identification guides on the following pages have been designed to give a quick reference to component parts used on all types of L.B. White construction heaters, such as convection, circulating, direct spark ignition, and kerosene heaters. The guides identify components not only used on current production, but also on equipment that is of earlier design. To use the guides properly, you should know the model number of the heater and its design sequence. For some heaters, there are no differences in components regardless of design or age. Therefore, you will find components are common, and identifying a specific design sequence is not necessary. Other heater models will refer to specific designs for parts selection. You will need to obtain the design sequence level to accurately determine the proper placement component. This information is identified on the dataplate. Some models may have the design sequence shown as the 4th digit of the model number. For other models, the dataplate will identify a configuration number. The design sequence is the first digit of the configuration number. Parts lists and schematics are shown on the following pages for the respective heaters. The parts guides also identify part numbers for the most commonly requested components, wires, and hardware items used on the heaters. If a wire, nut, or screw, etc. is not identified, please contact the L. B. White Co. for parts ordering information. Without Configuration Number MODEL 96E AW075EHP3 Dataplate Comparison A DESI GN G SERIAL NO.: AS G CONFIGURATION NO. AHPD10000 AS DSPD10104 ON I AT Design SERIAL NO.: ATI I I FI ED I FI ED MAXIMUM INPUT: 75,000 Sequence Design 60,000 BTUH MAXIMUM INPUT: 60, ,000 BTUH Sequence TYPE FUEL: PROPANE VAPOR WITHDRAWAL TYPE FUEL: PROPANE VAPOR WITHDRAWAL BURNER MANIFOLD PRESSURE IN W.C. AT MAXIMUM INPUT BURNER MANIFOLD PRESSURE 10.0 IN W.C. AT MAXIMUM INPUT ELECTRICAL: 115 VOLTS A.C. 60 HZ SINGLE PHASE 1.4 AMPS ELECTRICAL: 115 VOLTS A.C. 60 HZ SINGLE PHASE 1.5 AMPS MIN. CLEARANCES FROM HEATER TO ADJACENT COMBUSTIBLE MATERIALS: REAR 16 FT IN. SIDES 16 FT IN. MIN. CLEARANCES FROM HEATER TO ADJACENT COMBUSTIBLE MATERIALS: REAR 1 FT SIDES 1 FT TOP TO CEILING 16 FT IN. BLOWER OUTLET 610 FT AND FUEL CONTAINER 6 FT TOP TO CEILING 1 FT BLOWER OUTLET 6 FT AND FUEL CONTAINER 6 FT VENTILATION: CFM OF AIR REQUIRED TO SUPPORT COMBUSTION. VENTILATION: CFM OF AIR REQUIRED TO SUPPORT COMBUSTION. MAXIMUM INCHES W.C. AND MINIMUM 11.5 INCHES W.C. GAS SUPPLY PRESSURE MAXIMUM 13.5 INCHES W.C. AND MINIMUM 11.5 INCHES W.C. GAS SUPPLY PRESSURE ACCEPTABLE AT INLET 0F HEATER FOR PURPOSE OF INPUT ADJUSTMENT. ACCEPTABLE AT INLET 0F HEATER FOR PURPOSE OF INPUT ADJUSTMENT. POSITION HEATER AWAY FROM LIVESTOCK POSITION HEATER AWAY FROM LIVESTOCK AGRICULTURAL BUILDING HEATER AGRICULTURAL BUILDING HEATER A MERI SSOC CERT C A N I ON With Configuration Number MODEL AW060 CS170 A DESI GN A MERI C SSOC CERT A N L. B. WHITE CO., INC. W6636 L.B. WHITE ROAD ONALASKA, WI / L. B. WHITE CO., INC. W6636 L.B. WHITE ROAD ONALASKA, WI /

5 TRADESMAN Portable Forced

6 MODEL CP100C

7 PARTS IDENTIFICATION Model Item Description CP100C 1 Regulator, Single Stage Hose, 3/8 in. ID x 10 ft Adapter, Hose Cord, Power Panel, Left with Marking Case, Back Panel, Right Case, Front Control, Ignition Relay with Clips and Screws Tube, Manifold with Nuts and Sleeves Union Valve, Heat Adjustment Ell, 1/4 in Valve, Safety Control with Screen Screen Elbow Case, Barrel Bottom Switch, Backflash Bolt Nut Mount, Motor Motor Fan Thermocouple with Retaining Sleeve A Sleeve, Thermocouple Retaining (Not Illustrated) Igniter Ring, Bowed Ring, Flat Orifice with Rings Chamber, Heat with Igniter, Orifice and Burner Plate Guard, Inlet Case, Top Handle with Screws WIRE SELECTION TABLE DESCRIPTION COLOR LENGTH (IN.) PART NO. Ignition Control terminal N to L1 wire nut White 5 1/ Ignition Control terminal L to L wire nut Black 5 1/ Relay terminal #7 to L1 wire nut White 4 3/ Relay terminal #8 to L wire nut Black 4 3/ Ignition Control terminal # to ground screw Green Backflash Switch to Thermocouple energy cut-off block terminal Yellow Relay terminal #5 to Thermocouple energy cut-off block terminal Yellow Relay terminal #3 to Backflash Switch Yellow Ignition Control terminal #1 to Igniter terminal Red FASTENER SELECTION TABLE DESCRIPTION APPLICATION PART NO. Screw Case

8 MODELS 9E, 96E & 98E INSTALLATION FOR NATURAL GAS ONLY VALVE INLET

9 PARTS IDENTIFICATION Model Item Description 9E 96E 98E 1 Regulator L.P. Gas N/A Natural Gas N/A Hose, 1/In. x 10 Ft Adapter, 3/8 NPT x 1/ NPS Cord, Power Switch, On/Off Valve, Gas Control Bolt Nut Bracket Union Tube, Manifold w/ Nuts & Sleeves Harness, Wire Nut, Nylon Control, Direct Spark Ignition Screw, Nylon Case, Front Case, Base & Back Case, Right Panel Case, Left Panel Guard, Fan Mount, Motor Bolt Nut, Self Locking Bushing Bushing Switch, Air Proving Switch Backflash Motor Fan Case, Bottom Wire, Igniter Igniter w/ Nuts, Gapped Ring, Retaining (Bowed) Ring, Retaining (Flat) Burner Plate Orifice, Burner w/ Retaining Rings Heat Chamber Assembly (Includes Heat Chamber, Orifice & Igniter) 38 Nut Acorn Case Top Handle (w/ Screws) Bushing Nipple Nut Jam * Not available as an assembly. 1.4

10 MODELS CP100A, CP100B, CP155A & CP155B INSTALLATION FOR NATURAL GAS ONLY 41 VALVE INLET

11 PARTS IDENTIFICATION Model Item Description CP100A & CP100B CP155A & CP155B 1 Regulator L.P. Gas Natural Gas N/A Hose 1/ In. x 10 Ft Adapter, Hose to Regulator L.P. Gas Natural Gas Adapter, 1/ NPS x 1/ NPT, L.P. Gas Cord, Power Switch, On/Off L.E.D. w/ Leads Valve, Gas Control L.P. Gas Natural Gas Nipple Elbow Tube, Tinned Manifold, w/ Nuts & Sleeves Terminal Strip Bracket, Gas Control Bracket, Control Mounting Control, Ignition Transformer Case, Front Case, Base w/ Back Case, Panel, Left Case, Panel, Right Guard, Fan Bolt Nut, Self Locking Mount, Motor Bushing Switch, Air Proving Switch, Backflash Motor Fan Case Bottom Wire, Igniter Igniter, w/ Nuts Gapped Ring, Retaining, Bowed Ring, Retaining, Flat Burner Plate Orifice, Burner w/ Retaining Rings L.P. Gas Natural Gas Heat Chamber Assembly L.P. Gas Natural Gas (Includes Heat Chamber, Orifice, and Igniter) 38 Nut, Acorn Case, Top Handle, w/ Screws Nipple, Natural Gas 4 Nut, Jam

12 MODEL CP155C NON-DIAGNOSTIC CGA CERTIFIED MODELS LP-GAS HOSE AND REGULATOR ASSEMBLY NATURAL GAS HOSE AND REGULATOR ASSEMBLY 1.7

13 PARTS IDENTIFICATION Model CP155 C Item Description Non-Diagnostic 1 Regulator with POL (LP Gas) Regulator (Natural Gas) Hose, Fixed X Swivel, 3/8 in. x 10 ft., LP Hose, Fixed X Swivel, 3/8 in. x 15 ft. LP (Canada) Hose, Fixed X Swivel, 1/ in. x 10 ft. NG Hose, Fixed X Swivel, 1/ in. x 15 ft. NG (Canada) Adaptor, Hose, 3/8 in. (LP Gas) Adaptor, Hose, 1/ in. (Natural Gas) Nipple Bushing, Pipe Nipple, 1/ in. Close Valve, Manual Thermostat Knob Thermostat Power Cord Switch, ON/OFF Lens, L.E.D Case, Right Side Case, Left Side Case, Bottom and Back Solenoid Valve, 4V Solenoid Valve, 10V Bracket Valve, 4V Bracket Valve, 10V Union, Half Sleeve, Compression Nut, Compression Tube, Formed Copper, AGA (LP) Tube, Formed Copper, AGA (NG) Tube, Formed Copper, CGA (LP) Canada Tube, Formed Copper, CGA (NG) Canada Case, Front Direct Spark Ignition Control Direct Spark Ignition Control, AGA Direct Spark Ignition Control, CGA (Canada) Transformer Wire Harness, AGA Wire Harness, CGA (Canada) Air Inlet Guard Switch, Backflash, Assembly Switch, Air-proving/Sail, Assembly with Bracket Case, Barrel Bottom Bracket, Motor Mount Motor Fan Wire, Igniter, Black, AGA Wire, Igniter, Red, CGA (Canada) Igniter, Spark Plug, AGA Igniter, Spark Plug, CGA (Canada) Burner Plate, AGA Burner Plate, CGA (Canada) Orifice with Retaining Rings, AGA (LP) Orifice with Retaining Rings, AGA (NG) Orifice with Retaining Rings, CGA (Canada) LP Orifice with Retaining Rings, CGA (Canada) NG Panel, Heat Chamber ( Required) Case, Top Handle Terminal Block

14 MODEL CP155C DIAGNOSTIC CGA CERTIFIED MODELS LP-GAS HOSE AND REGULATOR ASSEMBLY NATURAL GAS HOSE AND REGULATOR ASSEMBLY 1.9

15 PARTS IDENTIFICATION Model CP155 C Item Description Diagnostic 1 Regulator with POL (LP Gas) Regulator (Natural Gas) Hose, Fixed X Swivel, 3/8 in. x 10 ft., LP Hose, Fixed X Swivel, 3/8 in. x 15 ft. LP (Canada) Hose, Fixed X Swivel, 1/ in. x 10 ft. NG Hose, Fixed X Swivel, 1/ in. x 15 ft. NG (Canada) Adaptor, Hose, 3/8 in. (LP Gas) Adaptor, Hose, 1/ in. (Natural Gas) Nipple Bushing, Pipe Nipple, 1/ in. Close Valve, Manual Thermostat Knob Thermostat Power Cord Switch, ON/OFF Lens, L.E.D Case, Right Side Case, Left Side Case, Bottom and Back Solenoid Valve, 4V Bracket Valve, 4V Union, Half Sleeve, Compression Nut, Compression Tube, Formed Copper, AGA (LP) Tube, Formed Copper, AGA (NG) Tube, Formed Copper, CGA (LP) Canada Tube, Formed Copper, CGA (NG) Canada Case, Front Direct Spark Ignition Control Transformer Air Inlet Guard Switch, Backflash, Assembly Switch, Air-proving/Sail, Assembly with Bracket Case, Barrel Bottom Bracket, Motor Mount Motor Fan Wire, Igniter, Red, CGA (Canada) Igniter, Spark Plug, AGA Igniter, Spark Plug, CGA (Canada) Burner Plate, AGA Burner Plate, CGA (Canada) Orifice with Retaining Rings, AGA (LP) Orifice with Retaining Rings, AGA (NG) Orifice with Retaining Rings, CGA (Canada) LP Orifice with Retaining Rings, CGA (Canada) NG Panel, Heat Chamber ( Required) Case, Top Handle Terminal Block

16 MODELS CP380A & CP380B d 10e c 13 10f 10b a

17 PARTS IDENTIFICATION Model Item Description CP380A CP380B 1 Regulator Adapter, 1/4 NPT x 1/ NPS Hose, 1/ In. x 10 Ft Adapter, 3/8 NPT x 1/ NPS Knob, Thermostat Cord, Power Switch, On/Off Thermostat L.E.D. w/ Leads Solenoid Valve Assembly (Includes Items 10a - 10c) 10a Ell, Brass b Valve, Throttle c Ell, Black Pipe d Nipple e Nipple f Bracket Elbow Manifold, Tube w/ Nuts & Sleeves Terminal Board Control, Ignition Transformer Boot, Capacitor Capacitor Switch, Air Proving, w/ Bracket Guard, Fan Switch, Backflash Wire, Igniter Igniter Orifice, w/ Retaining Rings Burner Plate Heat Chamber, w/ Burner Plate & Igniter Mount, Motor Motor Fan Blade Handle Nut, Acorn Case, Top Case, Front Case, Panel, Right Case, Bottom & Back Case, Panel, Left Bracket Case, Barrel, Bottom

18 MODELS 304D & CP400A d e c 13f a 13b

19 PARTS IDENTIFICATION Model Item Description 304D CP400A 1 Regulator Adapter, Hose 1/4 NPT x 1/ NPS Hose Adapter, Hose 3/8 NPT x 1/ NPS Knob, Thermostat Power Cord Switch, On/Off Thermostat Control, Ignition Case Panel, Right Side Case Panel, Left Side Air Inlet Guard Solenoid Valve Assembly (Includes Solenoid Valve Throttle Valve & Piping) 13A Ell, Brass B Valve, Throttle C Ell, Black Pipe D Nipple E Union F Bracket G Solenoid Valve Capacitor Switch, Air Proving w/ Bracket Tube, Manifold w/ Compression Nuts Switch, Backflash w/ Bracket Wire Igniter Orifice, Burner w/ Retaining Rings Igniter Burner Plate Combustion Chamber Motor Fan Acorn Nut Handle Case, Top Case, Bottom & Back Case, Front Wire Harness Capacitor Boot Mount, Motor w/ Bolt

20 MODEL CP400B NON-DIAGNOSTIC OR OR

21 PARTS IDENTIFICATION Model CP400B Item Description Non-Diagnostic 1 Regulator, w/ POL Hose Adapter, regulator outlet Hose, Fixed X Swivel, 3/8in. x 10 ft Hose, Fixed x Swivel, 3/8in. x 15 ft. (Canada) Thermostat Knob Thermostat Power Cord Switch, On/Off Case, Right Side Case, Left Side Case, Bottom and Back Case, Front Wire Harness, AGA Wire Harness, CGA (Canada) Direct Spark Ignition Control, AGA Direct Spark Ignition Control, CGA (Canada) Bracket, Solenoid Mount Solenoid Valve with Screen, 10V Tube, Formed Copper Capacitor Capacitor Boot Air Inlet Guard Case, Barrel Bottom Switch, Air Proving with Bracket Switch, Backflash Assembly, Manual Reset Wire, Igniter Orifice with Retaining Rings Igniter with Fasteners Burner Plate Combustion Chamber ( required) Bracket, Motor Mount with Bolt Motor Fan Case, Top Handle Nut, Acorn N/A - Not Applicable 1.16

22 MODEL CP400B DIAGNOSTIC

23 PARTS IDENTIFICATION Model CP400B Item Description Diagnostic 1 Regulator, w/ POL Hose Adapter, regulator outlet Hose, Fixed X Swivel, 3/8in. x 10 ft Hose, Fixed x Swivel, 3/8in. x 15 ft. (Canada) Thermostat Knob Thermostat Power Cord Switch, On/Off L.E.D Case, Right Side Case, Left Side Case, Bottom and Back Case, Front Direct Spark Ignition Control Transformer Bracket, Solenoid Mount Solenoid Valve with Screen, 4V Tube, Formed Copper Capacitor Capacitor Boot Air Inlet Guard Case, Barrel Bottom Terminal Block Switch, Air Proving with Bracket Switch, Backflash Assembly, Manual Reset Wire, Igniter Orifice with Retaining Rings Igniter with Fasteners Burner Plate Combustion Chamber ( required) Bracket, Motor Mount with Bolt Motor Fan Case, Top Handle Nut, Acorn N/A - Not Applicable 1.18