1 roduct OVErViEw ELETRI YLINDERS Stroke[mm] eak Fore[N]: AL12 Stroke[mm]: 10 Force [N]: 1.5 BL35 Stroke[mm]: 10, 15, 25 Force [N]: BL50 Stroke[mm]: 10, 25 Force [N]: BL35 with Built-in ontroller Stroke[mm]: 10, 15, 25 Force [N]: BL50 with Built-in ontroller Stroke[mm]: 10, 25 Force [N]:

2 gart numbering V MOD AL BL LA LAL LR LAR LS SLA LAS GR LXY Model Electric ylinders Linear Actuators Linear Rotary Actuators Linear Slides Grippers XY Stages Series Built-In ontroller Option available for BL series Stroke art Number Examples BL F3 BL35 series electric cylinder with built-in controller, 10mm stroke, 48volt single phase, 5 micron encoder, single coil, female shaft end, and flying lead LA F3 LA25 series linear actuator, 200mm stroke, 48volt multi phase, 1 micron encoder, 6-coil, female shaft end, and flying lead Notes Series will not have leading zeros (e.g. BL35) Stroke must include zeros (e.g. 050) Spring must be specified as full return or counter balance, payload and orientation (vertical or horizontal). Voltage 1 24VD Multi hase 3 48VD Multi hase 5 24VD Single hase 7 48VD Single hase Encoder Resolution µm µm µm µm µm Number of oil 1 1 oil 2 2 oils 3 3 oils 6 6 oils B F M V MOD Shaft Blank (standard) Female Male ustom Vacuum Vacuum through the shaft or on the shaft Spring S Spring SA 0g payload, vertical, full return* SB 50g payload, vertical, full return* S 100g payload, vertical, full return* SD 0g payload, vertical, counter balance* SE 50g payload, vertical, counter balance* SF 100g payload, vertical, counter balance* *Applicable for LA Series able 3 Flying lead 5 igtail *Applicable for AL, BL and LA Series Mounting A Front Mount (Standard) B Base Mount *Available for AL, BL Series Modification Mod number for custom modification Mod number will be assigned for I protection option 10

3 roduct SEcificATiOnS SMA Actuators Unique Features Soft-Land A patented capability to apply controlled light force without damaging parts/materials being handled. Feedback Built-in sensing that can report if the desired work was accomplished or not. It can be used for Data Acquisition. Linear Rotary Motion The precision Z-theta motion within one small compact actuator, providing convenient pick, orient, and place movements. I rotection Optional I65 and I67, dustproof and waterproof features. 11

4 ELETRI YLINDERS cal/cbl SEriES Direct replacement of air cylinders. High speed, compact and price-competitive cylinder actuators are the ideal solution for new machine designs and upgrade. Direct replacement of air cylinders ost competitive Long life expectancy, typically over 100 million cycles I protection optional art Number Voltage [D] Size: Dia.x L [mm] Stroke [mm] eak Force [N] ontinuous Force [N] Force onstance [N/A] Maximum urrent [Amp] Moving Mass [kg] Weight [kg] AL Ø12x BL Ø35x BL Ø35x BL Ø35x BL Ø35x BL Ø35x BL Ø35x BL Ø50x BL Ø50x BL Ø50x BL Ø50x BL Ø50x BL Ø50x NOTE: SMA requires that all units must be operated at less than suggested duty cycle (%). lease see page 26. We manufacture actuators to suit our customers requirements. lease call us if you do not find the right actuator in this list. AL12 BL35 BL50 Options & Modifications (onsult factory for availability) Encoder resolutions µm standard. 1µm optional. Shaft ends Male, Female, Blank and ustom. Return spring revents the shaft from dropping during vertical operation when power is cut. Vacuum Vacuum through the shaft or on the shaft for pick and place applications. Mount Face Mount (standard), foot mount optional. Threaded mount is available for AL12 series only. Dust/Waterproof I65/67 protection is available with BL series. 12

5 ELETRI YLINDERS WITH BUILT-IN ONTROLLER A complete self-contained unit, suggested for replacement of pneumatic cylinders where increased lifetime, speed and control are desirable. Built-in controller Airless and quiet operation Graphical User Interface for simple set-up I protection optional art Number Voltage [D] Size: Dia.x L [mm] Stroke [mm] eak Force [N] ontinuous Force [N] Force onstance [N/A] Maximum urrent [Amp] Moving Mass [kg] Weight [kg] BL Ø35x BL Ø35x BL Ø35x BL Ø35x BL Ø35x BL Ø50x BL Ø50x BL Ø50x BL Ø50x BL Ø50x BL Ø50x NOTE: SMA requires that all units must be operated at less than suggested duty cycle (%). lease see page 26. We manufacture actuators to suit our customers requirements. lease call us if you do not find the right actuator in this list. BL35 BL50 Options & Modifications (onsult factory for availability) Built-in ontroller Simple installation and effective use of space. Encoder resolutions µm standard. 1µm optional. Shaft ends Male, Female, Blank and ustom. Return spring revents the shaft from dropping during vertical operation when power is cut. Vacuum Vacuum through the shaft or on the shaft for pick and place applications. Mount Face Mount (standard), foot mount optional. Dust/Waterproof I65/67 protection is available. 13