1 Cowley County, Kansas CCEC CONSOLE SPECIFICATIONS RFP Beth Leach 1/22/2014

2 Cowley County Emergency Communications Specifications 1/23/2014 Page 2

3 Cowley County Emergency Communications Request for Proposal Emergency Communications Dispatch Console Furniture RFP Response Deadline February 7, 2014 Cowley County Emergency Communications Specifications 1/23/2014 Page 3

4 Cowley County Emergency Communications Specifications 1/23/2014 Page 4

5 PURPOSE The purpose of this Request for Proposal ( RFP ) is to obtain competitive proposals from qualified vendors who can design, furnish, deliver, install and provide service response for Emergency Communication Center console furniture. Parties responding to this RFP shall hereinafter be referred to as Proposer or Proposers. The information submitted by a Proposer in response to this RFP shall be referred to as the Proposal or Proposer s Response. Only those Proposers who are actively engaged in the business of providing Emergency Communication Center Furniture shall be considered as responsible Proposers. For the purpose of this RFP, actively engaged shall mean a recognized leader in the field of Emergency Communication center console design and installation. Documentation, including references showing installations shall be included in Proposer s response. Each Proposer shall be required to respond to the requirements set forth in the, Instructions to Proposer. These responses will be evaluated by the evaluation team. The Console RFP Evaluation Team will select the highest ranked Proposer K l BACKGROUND INFORMATION Cowley County Emergency Communications referred to as CCEC desires to obtain Ergonomic Modular Dispatch Furniture to be installed in the communication center. Arkansas City PD and Winfield PD Communication Officers plan to relocate to this new facility when it becomes operational. The new County center is expected to receive calls from across Cowley County and will dispatch the following agencies: Arkansas City Police Arkansas City Fire-EMS Cowley County Emergency Management Cowley County Sheriff Winfield Police Winfield Fire Winfield EMS Rural Fire Departments: Atlanta, Burden, Cambridge, Dexter, Udall Rural Law Enforcement: Burden PD & Udall PD CCEC is a new consolidated PSAP in Cowley County formed in July CCEC covers an area in excess of 11,000 square miles. The current population is estimated at 36, operations are currently located in Arkansas City PD and Winfield PD, however, they will be moving to the basement of a newly renovated facility in August This Request for Proposal (RFP) is primarily to design, furnish, deliver, install, and provide furniture repair/maintenance for the proposed equipment. Public Safety Answering Points (PSAP s) Emergency Communication Centers pose unique challenges and demands. Unlike an office environment, Cowley County Emergency Communications Specifications 1/23/2014 Page 5

6 Emergency Communications Personnel are required to manage multiple LCD/CRT monitors, plus additional ancillary electronics and other resources. Additionally, emergency communications consoles are utilized 24 hours per day/ 7 days per week by many different employees, with many different physical sizes and needs. Because of this, emergency communications consoles can be expected to receive at least five times the use of typical office furniture each year. With this in mind, only console future specifically designed and engineered for Emergency Communication Centers will be accepted. The console design and room layout must positively address employee comfort, efficiency, ergonomics, aesthetics, flexibility, durability, maintainability as well as future expansion. Consoles should meet American National Standards Institute (ANSI) BSR/HFES 100, Human Factors Engineering of Computer Workstations, as well as any applicable Americans with Disabilities Act (ADA) guidelines and requirements. The center is configured with five full dispatch consoles, and one training position. We will be installing only Supervisor console at this time, the four console areas along the north wall in the diagram, and the Training Console. The proposer is expected to propose one or more console designs for the new Communications Center Operations Area to accommodate 6 full dispatch positions initially while taking into consideration room for growth. Additional design consideration and pricing is being requested for up to 3 more full dispatch positions. Designs should show future expansion within space allotted for dispatch. Room dimensions are attached. INSTRUCTIONS TO PROPOSERS The proposal must be based on the enclosed emergency dispatch console furniture specifications. Sealed bids must be submitted to the Cowley County Clerk s Office located at the Cowley County Courthouse, 311 East 9 th Ave., Winfield, Kansas Bids must be received before 1:00 PM, February 14th, The Proposer has the sole responsibility to have the proposal received by the Cowley County Clerk at the above address and by the above stated time and date. The sealed envelope must be clearly marked on the outside Console Bid Enclosed. The bid opening will be at 3PM February 14 th, 2014 in the Assembly Room located at the Cowley County Courthouse. Proposals not so marked or sealed shall be returned to the Proposer and will not be considered. Proposals shall clearly indicate the legal name, address and telephone number of the Proposer (company, firm, partnership, or individual). Proposals shall be signed above the typed or printed name and title of the individual signing on behalf of the Proposer. All expenses for making Proposals to Cowley County shall be borne by the Proposer. The Cowley County Commission has the right to refuse any and all bids. Cowley County Emergency Communications Specifications 1/23/2014 Page 6

7 Questions regarding these bid specifications should be in writing no later than 12PM, Jan. 31 st, and directed to: Beth Leach, Director Cowley County Emergency Communications (620) or The Proposer must submit a proposal that demonstrates and provides evidence that the Proposer is able to provide suitable services and has the capabilities, professional expertise, and experience to provide the proposed consulting services. The Proposer must also submit references which indicate other organizations to which Proposer is providing and has provided similar services. Proposers are responsible for familiarizing themselves with the conditions and objectives of the property acquisition consulting services described herein. Two copies of your proposal and an electronic copy shall be submitted to: Cowley County Clerk 311 E. 9 th Ave. Winfield, KS Phone: kdefore@cowleycounty.org Proposers are responsible for familiarizing themselves with the conditions and objectives of the property acquisition consulting services described herein PROPOSAL REQUIREMENTS Use the following organization for the proposal o Introduction/Cover Letter o Organizational capabilities, Staff qualifications o References o Proposed installation timetable o Response to Technical Requirements o Proposed Room Layouts o Detailed cost summaries o Any additional material or brochures Introduction/Cover Letter Provide us an overview of your organization and years serving the emergency services furniture marketplace. Organizational capabilities and staff qualifications Describe the firm s experience and capabilities in providing similar layouts and equipment for emergency communications centers. Be specific and identify project, dates and results. Also provide references from these projects for contact. Cowley County Emergency Communications Specifications 1/23/2014 Page 7

8 Staff Qualifications Provide resumes describing the educational and work experiences for each of the key staff who will be assigned to the project. Designate the Proposers primary contact or Project Manager. References Proposals must include a list of organizations, including points of contact (name, address and telephone number), which can be used as references for work performed in similar projects. Selected organizations maybe contacted to determine the quality of work performed and personnel assigned to the project. Proposed Installation Timetable Provide a timetable of events from the contract, through completion of installation. Please discuss how you intend to manage the project through the various stages and how the equipment will be received and staged for installation. Who will install the consoles? Response to Technical Requirements Provide a point by point response to what you intend to supply and how you intend to meet the requirements. If you can provide other options to meeting these requirements, please provide details and optional pricing where appropriate. Proposed Room Layouts Provide a Computer Aided Drawing for the layout of 6 consoles on the Operations Floor and additional expansion consoles. Detailed Cost Summaries Provide detailed pricing for 6 consoles, with separate pricing for 3 more additional consoles on the dispatch floor. Consoles fully delivered and installed. Proposal Offer It is understood and agreed that this proposal and the response of the selected proposal, if accepted, will become part of a legal and binding contract between the undersigned Proposer and the CCEC. The contract shall be in force upon execution of the Notification of Contract Award by CCEC. Such notice will be mailed to the Proposer at the address shown on the Proposer s proposal. The Proposer here by declares and agrees with all the terms, conditions and requirements of this request for proposal. Also the undersigned Proposer, having full authority submitting this proposal, hereby declares and agrees to address all aspects of necessary equipment and components as listed here in accordance with all terms, conditions and requirements of the within and proposal. Additional Material Provide brochures or supplemental material you feel will help the evaluation team make an informed decision on your products and any options that you may want to suggest. Cowley County Emergency Communications Specifications 1/23/2014 Page 8

9 As a guideline, CCEC anticipates the following tentative timetable for selection of a Contractor. Date Jan. 22, 2014 Jan. 31, 2014 Feb. 7, 2014 Feb Feb Activity/Event Request For Proposal Issued Deadline for Questions is 12:00 noon Proposals Due Prior to 1:00 p.m. Deadline Evaluation of Proposals Completed by County Source Selection Committee (SSC) Interviews with Top Ranked Proposers by SSC completed. (Specific date to be determined) The vendor awarded a contact shall be licensed to conduct business in the State of Kansas. PROPOSAL EVALUATION The proposals will first be reviewed to determine if proposal requirements indicated above have been met. The accepted proposals will be reviewed by an evaluation committee and scored against stated criteria as well as references. The committee will evaluate all proposals in accordance with criteria set forth in this RFP and applicable law. During the evaluation process the committee may see information for a Proposer to clarify the Proposer s proposal. A Proposer must submit written clarifications and such clarifications shall become part of the Proposer s proposal. FINAL SELECTION RESULTS The final selection results will be posted on the CCEC website after the Proposer selection has been made. STATEMENT OF NEEDS Vendors shall provide unit pricing for all furniture components and/or options to permit the County the flexibility to add or subtract additional positions as needed. The County seeks to equip six (6) dispatch console positions within the new communications center. All new furniture shall be designed to achieve the highest performance possible for Cowley County today and in the future. Additional furniture may be necessary to expand or remodel the center and may be purchased through this contract. Cowley County Emergency Communications Specifications 1/23/2014 Page 9

10 GENERAL SPECIFICATIONS 1. Description of Project Console Furniture 2. Materials Specifications 3. Design Considerations 4. Pre-Construction Conference 5. Vendor Experience and References 6. Warranty / 24 Hour Service Response 7. Lead Time and Installation 8. Terms and Conditions 9. Communications room layout 10. Communications room electrical/data plan 11. Floor Plan Cowley County Emergency Communications Specifications 1/23/2014 Page 10

11 Cowley County Emergency Communications Console Furniture Specifications 1. DESCRIPTION OF PROJECT CONSOLE FURNITURE Public Safety/911 Emergency Communication Centers pose unique challenges and demands. Unlike an office environment, Emergency Communications Personnel are required to manage up to 6 CRT s and/or Flat Screens, plus additional ancillary rack mount electronics. Additionally, emergency communications consoles are utilized 24 hours per day/ 7 days per week by many different employees, with many different physical sizes and needs. It must be recognized that this user environment will receive at least five times the use of typical office furniture each year. With this in mind, only console furniture that is specifically designed and engineered for Emergency Communication Centers will be acceptable. Office furniture systems will not be considered. Floor plan and elevation drawings included in this document shall prevail as the specifications for all measurements, angles and dimensions. The textual specifications included shall prevail as the specifications for all other aspects of this project. The following specifications detail the minimum requirements of the Console Furniture System. Bidders must provide a point-by-point technical response stating compliance or taking exception. A. Console Modularity The Emergency Communication Center Console Furniture must be provided from standard, previously manufactured items that have the capability of adding on to or re-configuring at a later date. Add-on sections, such as bridges, peninsulas, and returns must be included. B. Ergonomics A minimum of 7-19 flat panel displays at each console must be mounted to integrated monitor arms that are secured to the sit to stand section for optimal flexibility. Two of those monitors will be touch screens for 911 Phone System and Radio Console. Adjustments must be able to be accomplished from the seated position in order to meet ADA requirements. Arm mounts must feature multiple points of rotation allowing multiple monitors to maintain a single focal length for viewer s eyes with a range of motion addressing: Vertical adjustment Side-to-side 360 rotation. Monitor tilt/pivot tilt; 180 side-to-side tilt; 360 portrait/landscape adjustment. Telescoping extension 0 to 20 Allow for use of touch screen monitors To reduce the incidence of repetitive stress injuries, the Console Furniture must provide height adjustable input platforms with tilting capability. The engineering of the console furniture must offer comfort, safety and adjustability for the operator. Console should meet ANSI/BIFMA, BSR/HFES 100, and ADA guidelines and requirements. Cowley County Emergency Communications Specifications 1/23/2014 Page 11

12 C. Structural Integrity The Console Furniture shall be designed specifically for 24/7 operations in an Emergency Communication Center environment. The core serves as the primary structural foundation for the console system and must carry a minimum load rating of 1000-lbs. The console walls must be sturdy enough to mount all electronic accessories, including monitors, without compromising the integrity of the system. The structure should be free standing and not rely on walls for support. D. Technology At a minimum each console must be designed to accommodate 4 CPUs, the Supervisor s console must be designed to accommodate a minimum of 8 CPUs. Electronics cavity storage provided for CPU equipment and cable routing must keep the knee space below the consoles unobstructed to allow dispatchers a full range of movement to reach necessary equipment. Access to all sides of each CPU must be provided from the front of the console without crawling under the console. CPUs must be accessible from the back as well. Cavities must have the option of passive or fan air circulation. Cabling chases must be designed for ease of access and incorporation of additional runs to meet future needs. E. Environmental Controls The Console Furniture must have available adjustable task lighting, indirect lighting, radiant heat, filtered airflow, sound masking system, and primary and input surface height adjustments. Environmental controls must all be readily accessible from a seated position and meet ADA requirements. User replaceable air filters should be provided for the entire standard warranty period. The console must provide individually controlled heating and cooling. Heating may be provided through radiant panels or forced air for leg and foot warming. The proposal shall describe the manufacturer of the system and its performance specifications. We desire individual controls from a single location on the workstation. Cooling is to be provided by personally controlled, fans that are movable by the user. We desire the cooling units not be mounted to a specific location on the console, so they can be moved by the operator. Systems should be automated to shut off during periods of inactivity. 2. CONSOLE REQUIREMENTS All equipment, material and articles requested under this specification are to be new or fabricated from new materials. The use of used, remanufactured, or rebuilt products is not allowed under this specification. A. Acoustical Console Walls The operations room in which these consoles will be installed has an open ceiling with some sound deadening properties. In addition to sound masking environmental controls the acoustical properties of the consoles then becomes very important to the function of the room. Acoustical walls shall be constructed with a high density, fire resistant, sound absorbing subsurface. Edges of these partitions shall be durable and replaceable. All fasteners must be completely concealed. The console walls must be sturdy enough to mount all electronic accessories, including monitors, without compromising the integrity of the system. Leveling glides shall be an integral part of the system to accommodate uneven floors. Cowley County Emergency Communications Specifications 1/23/2014 Page 12

13 B. Surfaces All primary work surfaces, input platforms, and extension surfaces shall be constructed of durable materials that will withstand the 24-hour use environment of an Emergency Communication Center. Primary work surfaces and extensions shall include cable drop areas for access into the fixed electronics cavities. All edges must be treated in a replaceable high impact edging material. Extension and Bridge surfaces must match the primary work surface depth with widths dictated by enclosed floor plan. 1. Monitor and Keyboard surfaces Surfaces should be separate and be adjustable separately with smooth, quiet motorized control. The operator must be able to make all monitor and keyboard adjustments from either a standing or sitting position. Surface movement requires the operator to click and hold the controls. At least one inch safety clearance between all moveable and fixed surface is required. A safety system should be in place to prevent accidental lowering of the unit when it is taken off line for service. Proposers are encouraged to propose the ability for users to quickly adjust monitor and keyboard surfaces to personally present heights. These surfaces must be non porous, non glare and of high pressure laminate or solid surface materials of standard color (meaning items readily available or no special order materials). Surfaces should be mark, stain and scuff resistance and easy to maintain and clean. All corners and edges will be rounded and properly finished in similar solid surface materials. 2. Monitor Surface The surface must be able to pull forward/push back for operator comfort. The unit must be able to accommodate up to seven (7) 19 inch monitors without obstructing the view. The monitor surface must rise to 50 inches and lower to approximately 23 inches to accommodate operation while sitting or standing. The monitor surface must be able to hold a minimum of 500 static pounds and lift 50 pounds minus the weights of the surface and components. Additionally we encourage the proposer to address considerations of bracket rack mounted monitors, possible dual stacked, fixed mounted and/or articulating arms. 3. Keyboard Surface The keyboard surface must rise to 46 inches and lower to approximately 23 inches to accommodate operation while sitting or standing. The monitor surface must be able to hold a minimum of 500 static pounds and lift 50 pounds minus the weight of the surface and components. The keyboard surface must accommodate two standard size keyboards and one keypad for telephone functions. We desire the ability to tilt the keyboard up to 45 degrees, if used how this would this be accomplished. Cowley County Emergency Communications Specifications 1/23/2014 Page 13

14 C. Pedestals and Accessories Drawer hardware must be full extension, precision ball bearing construction with a minimum 100 lb. load rating per drawer. All file drawers must have built-in hanging file capability. All doors must include full articulation door hardware to accommodate uneven floors. The pedestals shall be finished on all sides for use outside the console, and be equipped with dual-wheel front-locking casters. Cushion seating should be available as options and should be rated for 300 lbs. At a minimum, the following options should be made available: Bookcases File Drawers Box Drawers Lateral File Drawers Overhead shelves with adjustable height legs for console mounting D. Edge Material Replaceable vinyl edging material shall be a minimum 2mm thick thermoplastic vinyl extrusion with self-healing properties against abrasion for all undercarriage, pedestals, and primary surfaces, and a minimum 13mm thick for all input platforms. E. Equipment Enclosures Equipment enclosures must include EIA mounting rails front and rear. Each console should include at a minimum 2 racks each 19 deep X 22 wide X 8 high. The Supervisor s console must include 4 racks of the previous dimension and 2 racks 22 deep X 19 width X 8 high. Rack dimensions may be refined in pre-construction conference. Blank faceplates accenting or matching surrounding finish must be included with each rack. At a minimum, the following options should be made available: Interior task lighting to equipment cabinetry Access to CPUs/cabling from front and back Quiet blowing ventilation for equipment cabinetry F. Laminates High pressure must meet ANSI/ASME A 17.1; 1986 requirements for Class "B" laminate, providing a non-glare matte finish. Thermally Fused Laminate must meet NEMA LI Low Pressure Laminate is not acceptable. G. Fabric Abrasion resistance at a minimum shall meet ASTM D-3597 MVPTS-198 standards. The flammability requirements shall adhere to ASTM E-84 (Tunnel Test) or Class A or 1 and the State of California Technical Bulletin 117 Sec. E (SC ). H. Sit to Stand Base and Articulating Input Platform Primary Surface: Components shall be UL listed. The motor/gear drive system must have a 700 lb. gross weight lifting capacity, including the surface, input platform, and input platform mechanism. Design must accept uneven load distribution. Range of travel will need to accommodate a low of 27 to a high of 44, infinitely adjustable within the 17 range. Input Platform: Infinite travel range from 5 above to 5 below the primary surface, must have the capability of being tilted forward and backward. The Input Platform shall be designed to provide un-obstructed knee clearance in the seated operating Cowley County Emergency Communications Specifications 1/23/2014 Page 14

15 position in accordance with ANSI standards. Platform must be tested to 250 lbs. Input Platform must be secured to the primary surface by metal-to-metal connection utilizing steel plates and 1 bolts, no wood screws will be acceptable. Unified Frame: Adjustments: Sit-to-stand base must be designed with a footprint to allow maximum stability based on the overall size of the CRT/Flat Screen primary surface. The entire console must be tied together so that there will be no movement of the primary surface away from the remainder of the console. It must meet ANSI/HFS standards and ADA requirements for foot and leg clearance. There must not be any obstructions for side-to-side movement within the footprint of the console. Leveling glides shall be an integral part of the system to accommodate uneven floors. All adjustments for the sit-to-stand base and input platform shall be attained from the front of the input platform or the front of the primary surface, and shall be able to be adjusted from either the seated or standing position with the use of one hand to meet ADA requirements. I. Electrical and Cable/Wire Management Every console must include two separate 120 V single phase electrical systems, one a typical 3 wire system for dirty power and the other a 4 wire isolated ground system with orange devices. The 3 wire system must provide a minimum of 8 3-prong outlets with room for 3 transformer plugs on a U.L. listed and CSA rated 20 amps, 120-volt power center. Outlet color to match or accent fabric and laminate and shall not be orange, blue, yellow, or green. The isolated ground system must provide a minimum of 10 3-prong orange outlets with room for 3 transformer plugs on a U.L. listed and CSA rated 15 amps, 120-volt power center. These power centers shall include a circuit breaker with 1900 joules AC surge suppression to shield equipment from the strongest surges and line noise. Specific electrical ratings will be refined in the pre-construction conference. All wiring shall be #12 copper wire minimum. Each system must terminate in a fashion to facilitate the user s installation of two power cords. The isolated ground system will be connected to a facility-wide UPS system. The second cord powering the dirty side must drive all needs inherent to the console operations. Refer to the Electrical Plan E2.1 for additional electrical requirements. Dimensioned Electrical drawings detailing line voltage and low voltage with precise vertical and horizontal placements will be used by the general contractor in determining final placement of outlets on walls. Each console must include options for user-accessible voice and data connections. Each data/voice outlet shall be a 4 sq X deep box with a single gang plaster ring. Face plate to accept six Leviton data jacks. Provide owner with four blank inserts of matching color. Minimum capacity feeding each box will be two 1.25 conduits with bushings at the exposed ends. Provide and install pull wires for owners use. All data and voice paths must be completely segregated from the power management systems. Each console shall have a minimum of two data/voice outlet boxes. Alternatively each fixed cavity may accommodate front access to data/voice jacks located 6 above the finished floor on the wall. Please note this alternative method will not be acceptable for the supervisor s island, which will be fed from the ceiling and should be considered as two consoles for data cabling requirements. Cowley County Emergency Communications Specifications 1/23/2014 Page 15

16 Each console must include two (2) cable drops with a minimum of inside diameter for vertical interconnectivity from primary surface to cavity. Grommet style cable drops on extensions and bridges must be included to each fixed cavity section. An additional access port to allow a data plug must allow entry from the wall, or ceiling mount for Supervisor s console, into the fixed cavity. The complete data plug dimensions will be available at the pre-construction conference for review and needed inside diameter adjustments will be considered at that time. A cable management system must be provided that allows for independent movement among the monitor and keyboard surfaces. The system must minimize the wear and tear on the traveling cables by keeping them separated as well as enclosed. No operator intervention is to be required. The proposer is to provide all cable management within, under and on the console. Describe your system for data docking that allows fast connection of keyboards and additional equipment. J. Task Lighting Cavity illumination should be offered as an option Cavity fans should be offered as an option Ambient light levels will be very dim and task lighting incorporated in the consoles will be the primary source of lighting for dispatchers and call takers. Lighting solutions must provide 100% of the required light at each workstation and provide user controlled, infinite dimming variability. Please specify the lighting you will supply. Provide its expected life and rated lumen output. Also list and price any other lighting options you have available under a Lighting Options section. K. Headsets/Speakers Each console must support dual headset jacks for both radio and telephone. Describe how your console will accommodate that. Also, small cube speakers for selected and unselected radio traffic needs to be accommodated on the console. Describe how this would be accomplished. L. Storage Cabinets Each console will be equipped with additional drawer units for storage of personal items and work items at the various positions. The cabinet would be able to be housed under the keyboard and monitor surfaces while they are in the fullest downward position, or to the side. The drawers should match the color and design of the console. Describe your offering. M. Resource Storage Describe the option to provide an easily accessible cabinet to store resource materials. These could be books of procedures or maps of campus areas. Multiple consoles would share these resources, depending upon room layout. Cowley County Emergency Communications Specifications 1/23/2014 Page 16

17 N. Miscellaneous Modular furniture units shall not bolt together. Console furniture shall not be secured to the wall Vendors may offer alternative layouts and equipment options which will be evaluated by CCEC. User Control Unit (Personal Comfort Control Package) must provide a control for fan speed of desktop airflow, leg and foot warming via radiant heat panel, background noise masking, and task light dimming adjustment. O. Accessories Vendor shall offer a full complement of accessories to be available including: environmental controls personal storage shared resources task lighting foot supports wrist rests call status bars 3. DESIGN CONSIDERATIONS Each bidder must submit a floor plan to scale, showing each item being proposed. In addition, perspective drawings will be required in the submittal with dimensions of height, width, and depth in order to determine compliance with the specifications. All accessories being proposed must be shown in these drawings. Customer provided electronics such as CRT s, Flat Screens, telephones, CPUs, and rack mount panels must be shown, to scale, in the 3-dimensional/perspective drawings. Labeled cut away or exploded illustrations of acoustical walls, primary surface, and sit to stand base should be included. Colors are to be selected from manufacturer s standards. At a minimum one full set of laminate, edge, and fabric samples must be submitted with the proposal. It will be necessary to provide color boards and/or color renderings at the pre-construction conference to make a final decision. 4. PRE-CONSTRUCTION CONFERENCE Upon award of contract to a successful bidder and prior to construction, a pre-construction conference will be held at purchasers place of business. The conference will take place within 14 calendar days of the award of bid. The conference shall be attended by the manufacturer s representative(s). The purchaser s representation will include the Department Director, Contractor representative(s), Architect representative(s), Electrical Engineer, Radio Equipment Vendor, Voice and Data Vendor(s), and staff members assigned to the console selection team. The conference goals include - consider standard options for cost savings; insure the manufacturer has direct access to technical resources such as radio vendor representatives familiar with CCEC equipment for radio cabling needs; make specific selections on options such as color; determine specifically how delivery will be incorporated in the remodeling schedule; and answer questions and/or provide resources for all interested parties. Cowley County Emergency Communications Specifications 1/23/2014 Page 17

18 The conference agenda will include the following items: I. Bid Overview and Options II. Manufacturer Exception List III. Specification Items To be Determined list IV. Manufacturer Bid Line Item List V. Final Inspection procedures VI. Roles & Responsibilities VII. Other 5. VENDOR EXPERIENCE / REFERENCES The Emergency Communication Center Console Furniture to be supplied shall have a proven record of use within the harsh 24-hour operating environment of public safety dispatch centers, specifically of similar size to this request. Only companies with a minimum of 10 years experience in designing and manufacturing ergonomic console furniture will be allowed to bid. A list of no less than ten (10) Centers installed of like size must be included with the proposal, complete with contact name, address, phone, , date of installation, size of installation, and days to deliver from order date. If bidder is not the manufacturer of all major components, such as surfaces, console walls, environmental controls, and lift systems, then the bidder must specify which manufacturer is being used and include their reference information and past experience to determine qualified status. 6. WARRANTY /24-HOUR SERVICE RESPONSE The Emergency Communication Center Console Furniture must be warranted to be free from defects in material and workmanship for five (5) years based on 24/7 usages with a lifetime warranty on the frame. This must be an all-inclusive warranty and will need to cover 100% of the console furniture for the entire 5-year period. Warranty must include all product, freight, and installation. Under no circumstances will less than a 5-year all-inclusive warranty be considered. Under no circumstances will the buyer be responsible for any costs derived from poor product performance over the entire 5- year period. Bidders must supply a copy of their minimum all-inclusive 5-year warranty with the name, contact, and phone number of the service organization providing the 24-hour service response, signed by an authorized representative of the Company. All service and warranty work must be initiated within a minimum of 48 hours after notification. Describe who would be performing the service work, their location and their connection to your company. 7. LEAD TIME AND INSTALLATION Lead-time could be a critical factor. Bidders must present their best lead-time to design, manufacture, ship, and install the console workstation system. Shipping must be direct to the facility, inside delivery, unless otherwise noted. Cowley County Emergency Communications Specifications 1/23/2014 Page 18

19 Trained professionals experienced with the working environment of a public safety Communication Center must perform installation. Only the manufacturer s factory installers or their trained and authorized designees shall assemble and install the workstations. A list of no less than fifteen (15) projects for the installation team must be submitted in order to be considered. Accommodations will be made for recycling or removing of packing material. Once the installation is complete, a walk-through will be required with the installation Foreman in order to ascertain full compliance to the floor plan, console design, and materials specified. Any inconsistencies will be noted and must be scheduled for completion prior to sign off of the project. 8. TERMS AND CONDITIONS All drawings, specifications, data, photos and other work products prepared by the Contractor in the performance of its obligations under this Contract shall be exclusive property and shall be remitted to upon the cancellation or expiration of the Contract unless otherwise extended. The Contractor may retain one copy for the Contractor s files. The Contractor shall not use, willingly allow or cause to have such materials used for any purpose other than for meeting performance obligations under this Contract without the prior written consent of CCEC reserves the right to investigate Proposers background, references, and any other claims made as a result of the Proposers participation of this process. CCEC is not responsible for costs of proposing if decides to cancel or re-solicit, any costs incurred are at the proposer s own risk. CCEC reserves the right to accept or reject any or all proposals and to waive any informality in proposals. Exceptions and/or conditions may result in the proposals rejection as non responsive. CCEC reserves the right to cancel the procurement. Protests and requests for clarification must be in writing. Any changes by the agency will only be reliable if made by formal written addenda and posted to the agency website prior to submission deadline. Proposal Withdrawal Any Proposal may be withdrawn up until the time set above for the opening of the Proposal. Any Proposals not so withdrawn shall constitute an irrevocable offer for a period of 120 days. 9. TRAINING Each proposer is to include training on the new consoles during installation if applicable. This will be a train the trainers class during the installation period at the new Center. Cowley County Emergency Communications Specifications 1/23/2014 Page 19

20 10. COMMUNICATIONS ROOM LAYOUT 34 0 Cowley County Emergency Communications Specifications 1/23/2014 Page 20

21 11. COMMUNICATIONS ROOM ELECTRICAL-DATA PLAN Cowley County Emergency Communications Specifications 1/23/2014 Page 21

22 Cowley County Emergency Communications Specifications 1/23/2014 Page 22

23 Cowley County Emergency Communications Specifications 1/23/2014 Page 23

24 Cowley County Emergency Communications Specifications 1/23/2014 Page 24

25 12. Floor Plan and Elevations Cowley County Emergency Communications Specifications 1/23/2014 Page 25

26 Cowley County Emergency Communications Specifications 1/23/2014 Page 26

27 Cowley County Emergency Communications Specifications 1/23/2014 Page 27

Klamath Communications District Request for Proposal Emergency Communications Dispatch Consoles

Klamath Communications District Request for Proposal Emergency Communications Dispatch Consoles Klamath 9 1 1 Communications District Request for Proposal Emergency Communications Dispatch Consoles RFP Response Deadline October 1, 2010 INDEX 1. Purpose of RFP. 3 2. Project Description. 4 3. Project

More information

10. FURNITURE, DISPATCH CONSOLE

10. FURNITURE, DISPATCH CONSOLE 10. FURNITURE, DISPATCH CONSOLE Category Definition: Specialized dispatch center workstations, CPU enclosures, and auxiliary furniture such as storage units, printer cabinets, files, and tables. Example

More information

ALARIS CONSOLE ABOUT ALARIS CONSOLE ALARIS CONSOLE FEATURES. Product Specification Document Date Published: September 17, 2004

ALARIS CONSOLE ABOUT ALARIS CONSOLE ALARIS CONSOLE FEATURES. Product Specification Document Date Published: September 17, 2004 Product Specification Document Date Published: September 17, 2004 ALARIS CONSOLE ABOUT ALARIS CONSOLE Alaris is designed specifically for mission critical operations such as in Air Traffic Control (ATC)

More information

Architect and Engineer Specifications

Architect and Engineer Specifications Architect and Engineer Specifications Control Room Consoles 2008 Winsted Corporation Model: E-SOC CONTROL STATIONS 10901 Hampshire Ave. So., Minneapolis, Minnesota 55438-2385 U.S.A. Telephone: (800) 447-2257

More information

WINDOW TREATMENTS Window Blinds Window Shades Roller Window Shades

WINDOW TREATMENTS Window Blinds Window Shades Roller Window Shades 12 20 00 WINDOW TREATMENTS 12 21 00 Window Blinds 12 24 00 Window Shades 12 24 13 Roller Window Shades 12 50 00 FURNITURE 12 51 00 Office Furniture 12 51 16 Case Goods 12 51 19 Filing Cabinets 12 51 16.16

More information

MODEL: ASCEND SIT/STAND COMMAND CENTER CONSOLES

MODEL: ASCEND SIT/STAND COMMAND CENTER CONSOLES 2015 WINSTED CORPORATION 1) GENERAL DESCRIPTION 1.1 Ascend Command Center Consoles. See Appendix A - D for typical styles and measurements. 1.2 The contractor shall supply a system capable of supporting

More information

SECTION Manufactured Metal Casework FLEXIBLE LABORATORY FURNITURE SYSTEM (OPTIMA) USA VERSION

SECTION Manufactured Metal Casework FLEXIBLE LABORATORY FURNITURE SYSTEM (OPTIMA) USA VERSION SECTION 12 31 00.4 Manufactured Metal Casework FLEXIBLE LABORATORY FURNITURE SYSTEM (OPTIMA) USA VERSION PART 1 GENERAL Summary: This Specification identifies the minimum material and construction standards

More information

Architect and Engineer Specifications

Architect and Engineer Specifications Architect and Engineer Specifications 10901 Hampshire Ave. So., Minneapolis, Minnesota 55438-2385 U.S.A. Telephone: (800) 447-2257 or (952) 944-9050 FAX: (800) 421-3839 or (952) 944-1546 2008 Winsted Corporation

More information

TENDER # SUPPLY OF DINING AND BEDROOM FURNITURE FOR WESTERN HEALTH

TENDER # SUPPLY OF DINING AND BEDROOM FURNITURE FOR WESTERN HEALTH SPECIFICATIONS FOR TENDER #0171-0957 SUPPLY OF DINING AND BEDROOM FURNITURE FOR WESTERN HEALTH CLOSING DATE: 30 November 2009 CLOSING TIME: 11:00 AM (Newfoundland Time) WESTERN REGIONAL HEALTH AUTHORITY

More information

Telecommunication Spaces

Telecommunication Spaces Telecommunication Spaces October 19, 2016 Page 1 Revision History Telecommunication Spaces Standard Effective Date Email Version Contact Phone OIT-TS strevena@csustan.edu 1.0 Stan Trevena 209.667.3137

More information

MODEL: ASCEND SIT/STAND COMMAND CENTER CONSOLES

MODEL: ASCEND SIT/STAND COMMAND CENTER CONSOLES 2015 WINSTED CORPORATION EMAIL: info@winsted.com WEB: winsted.com TEL: 800.447.2257 or 952.944.9050 FAX: 800.421.3839 or 952.944.1546 10901 Hampshire Ave. So. Minneapolis, Minnesota 55438-2385 U.S.A 1)

More information

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual FORM HEADWALL (floor mount) Installation Manual FORM HEADWALL (floor mount) OVERVIEW The Form is a UL-listed configurable headwall system. This system includes multiple horizontal equipment channels integrated

More information

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

SCI-FAB Product Specifications. Casework Section 1. Part 1 General SCI-FAB Product Specifications Casework Section 1 Part 1 General 1.1 SCOPE OF WORK Includes all factory fabricated stainless steel casework as required by the project drawings. 1.2 TYPICAL INCLUSIONS A.

More information

Series A GSA APPROVED

Series A GSA APPROVED Series A GSA APPROVED Series A Open leg table design provides flexible solutions. Slate Series A Versatile C-Leg table design permits easy configurations, ideal for Open Space Offices, Cubicles, Multi-Person

More information

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual FORM HEADWALL (floating) Installation Manual FORM HEADWALL (floating) OVERVIEW The Form is a UL-listed configurable headwall system. This system includes multiple horizontal equipment channels integrated

More information

SPECIFICATIONS SYSTEMS NEW INSTALLATION

SPECIFICATIONS SYSTEMS NEW INSTALLATION MINIMUM PERCENTAGES: SPECIFICATIONS SYSTEMS NEW INSTALLATION Bidders must offer a minimum percent discount from published catalog price list of 65% on Systems and Metal Case Goods and must submit a discount

More information

Series A GSA APPROVED

Series A GSA APPROVED Series A GSA APPROVED Series A What you need. Our total turnkey solution has everything you need for hassle-free furniture buying. With the right products and services, we ensure you get great furniture

More information

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 10560 MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

SYSTEM 600 BILL CHANGER INSTALLATION INSTRUCTIONS Congratulations...

SYSTEM 600 BILL CHANGER INSTALLATION INSTRUCTIONS Congratulations... www.standardchange.com 1-800-968-6955 Technical Phone Support is from 8:00AM to 7:30PM E.S.T., Monday-Friday Walk-in Service is from 8:00AM to 4:30PM E.S.T., Monday-Friday Parts Department is from 8:00AM

More information

MODEL: SLAT-WALL COMMAND CENTER CONSOLES

MODEL: SLAT-WALL COMMAND CENTER CONSOLES 2015 WINSTED CORPORATION EMAIL: info@winsted.com WEB: winsted.com TEL: 800.447.2257 or 952.944.9050 FAX: 800.421.3839 or 952.944.1546 10901 Hampshire Ave. So. Minneapolis, Minnesota 55438-2385 U.S.A MODEL:

More information

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount) INSTALLATION MANUAL FOOTWALL/SINKWALL (floor mount) OVERVIEW The Form is a UL-listed configurable footwall/sinkwall system. This system can include any combination of base cabinets, upper cabinets, wardrobes,

More information

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

1. Section , Gas and Vacuum systems for Laboratory and Healthcare Facilities

1. Section , Gas and Vacuum systems for Laboratory and Healthcare Facilities PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Pre-Fabricated Modular Futrus Headwall System a. Futrus Headwall as detailed on the drawings, including related components and accessories required

More information

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project. SECTION 14651 FREE STANDING JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station and industrial

More information

CLINICS. LABS. PHARMACIES. PREP AND PACK.

CLINICS. LABS. PHARMACIES. PREP AND PACK. CLINICS. LABS. PHARMACIES. PREP AND PACK. Everything you need to build, renovate or supplement a lab WHERE THE MOST INNOVATIVE WORK IN THE WORLD IS BEING DONE OUR PRODUCTS ARE MADE FOR PLACES WHERE THE

More information

RESPONSE CONSOLE ABOUT RESPONSE CONSOLE RESPONSE CONSOLE FEATURES. Product Specification Document Date Published: September 17, 2004

RESPONSE CONSOLE ABOUT RESPONSE CONSOLE RESPONSE CONSOLE FEATURES. Product Specification Document Date Published: September 17, 2004 RESPONSE CONSOLE Product Specification Document Date Published: September 17, 2004 ABOUT RESPONSE CONSOLE The ultimate solution for the 24/7 command and control room operation, the Response console provides

More information

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND SECTION 08352 FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND THREE PART SHORT FORM SPECIFICATIONS (CSI) PART 1 GENERAL 1.1 SUMMARY A. Section Includes: manually operated, side folding accordion- type products

More information

MODEL: SPECTRUM-2 - CONSOLES

MODEL: SPECTRUM-2 - CONSOLES 2015 WINSTED CORPORATION EMAIL: info@winsted.com WEB: winsted.com TEL: 800.447.2257 or 952.944.9050 FAX: 800.421.3839 or 952.944.1546 10901 Hampshire Ave. So. Minneapolis, Minnesota 55438-2385 U.S.A MODEL:

More information

Illinois Valley Regional Dispatch RFP Disclaimer Logging Recorder

Illinois Valley Regional Dispatch RFP Disclaimer Logging Recorder Illinois Valley Regional Dispatch RFP Disclaimer Logging Recorder To the extent any of the following requirements are propriety or vendor specific or in any way limits open and competitive proposals IVRD

More information

Classic styling with clean lines and extended modesty panels.

Classic styling with clean lines and extended modesty panels. Series C Series C Classic styling with clean lines and extended modesty panels. Series C Classic Shell desk design at a great value. Ideal for closed offices and wherever professionals work: reception

More information

MODEL: SIGHT-LINE- COMMAND CENTER CONSOLES

MODEL: SIGHT-LINE- COMMAND CENTER CONSOLES 2015 WINSTED CORPORATION 1) GENERAL DESCRIPTION 1.1 Sight-Line Command Center Consoles. SeeAppendix A - C for typical styles and measurements. 1.2 The contractor shall supply a system capable of supporting

More information

C. Preparation and submission of complete engineered shop drawings for approval. E. Coordination with other affected work, trades and inspections.

C. Preparation and submission of complete engineered shop drawings for approval. E. Coordination with other affected work, trades and inspections. SECTION 11 61 13 ARIA ACOUSTICAL SHELL PART 1-GENERAL 1.1 SUMMARY A. This specification section includes the engineering, fabrication, furnishing, delivery and installation of new acoustical shell system

More information

ViewPoint. c u s t o m i z a b l e specificat i o n clips a v a i l a b l e at middleat l a n t i c.com

ViewPoint. c u s t o m i z a b l e specificat i o n clips a v a i l a b l e at middleat l a n t i c.com 96-01132 / rev. 1b / 07-02-10 EXCEPTIONAL SUPPORT & PROTECTION ViewPoint Monitoring Console System EIA/TIA Compliant Flexible, scalable system has been designed for optimum operator effectiveness Features

More information

FORM FOOTWALL. FORM FOOTWALL (floating) (floating) Installation Manual

FORM FOOTWALL. FORM FOOTWALL (floating) (floating) Installation Manual FORM FOOTWALL (floating) Installation Manual FORM FOOTWALL (floating) OVERVIEW The Form is a UL-listed configurable footwall system. This system can include any combination of base cabinets, upper cabinets,

More information

SECTION PATIENT BED SERVICE WALLS

SECTION PATIENT BED SERVICE WALLS PART 1 GENERAL 1.1 DESCRIPTION: SECTION 10 25 13 PATIENT BED SERVICE WALLS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Due to the very specialized nature of Patient Wall

More information

SECTION MOTOR CONTROL CENTER

SECTION MOTOR CONTROL CENTER SECTION 16445 MOTOR CONTROL CENTER PART 1 GENERAL 1.01 DESCRIPTION A. This section covers the contract item Motor Control Center (MCC). The contract item includes demolition and removal of existing MCC;

More information

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 SECTION 08 32 20 EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

SECTION The specification section is organized by placing information in three standard parts:

SECTION The specification section is organized by placing information in three standard parts: SECTION 14244 LIMITED USE HYDRAULIC ELEVATOR ***** Since 1982 Liftavator, Inc. has provided limited use/limited application (LU/LA) elevators, residential elevators, hydraulic vertical platform wheelchair

More information

INVITATION TO BID (Request for Proposal)

INVITATION TO BID (Request for Proposal) INVITATION TO BID (Request for Proposal) July 5, 2017 PROJECT Collaborative Spaces Furniture PROJECT DESCRIPTION The Topeka and Shawnee County Public Library is a 21st-century, landmark library; most recently

More information

1 data PIC location (with 2 ports) typically asf for multiple staff members

1 data PIC location (with 2 ports) typically asf for multiple staff members 1 Introduction 1.1 In the design of Telecommunications systems in Purdue facilities, the overall consideration should be to understand and treat telecom as a utility. It should be assumed that all new

More information

1. Telecommunications mounting elements. 2. Backboards. 3. Telecommunications equipment racks and cabinets. 4. Grounding.

1. Telecommunications mounting elements. 2. Backboards. 3. Telecommunications equipment racks and cabinets. 4. Grounding. ALLIANT ENERGY CENTER PAVILIONS Project No. 2013 027 SECTION 27 11 00 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Appendix C: Space Allocation & Calculation Guidelines

Appendix C: Space Allocation & Calculation Guidelines Appendix C: Space Allocation & Calculation Guidelines Introduction Work Space Design The suggested space guidelines represented in this section establish the basis for the square footage projections and

More information

SECTION LIGHTING. A. Section Basic Electrical Materials and Methods

SECTION LIGHTING. A. Section Basic Electrical Materials and Methods SECTION 16500 LIGHTING PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide lighting fixtures of sizes, types and ratings as indicated; complete with, but not necessarily limited to, housings, lamps, lamp holders,

More information

SECTION to 5000 AMPERE PLUG-IN AND FEEDER BUSWAYS - SPECTRA. A. Low-Voltage Plug-in Busway to 5000 ampere, 600 VAC

SECTION to 5000 AMPERE PLUG-IN AND FEEDER BUSWAYS - SPECTRA. A. Low-Voltage Plug-in Busway to 5000 ampere, 600 VAC PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Low-Voltage Plug-in Busway - 225 to 5000 ampere, 600 VAC 1.02 RELATED

More information

C. Preparation and submission of complete engineered shop drawings for approval. E. Coordination with other affected work, trades and inspections.

C. Preparation and submission of complete engineered shop drawings for approval. E. Coordination with other affected work, trades and inspections. SECTION 11 61 13 BRAVADO ACOUSTICAL SHELL PART 1-GENERAL 1.1 SUMMARY A. This specification section includes the engineering, fabrication, furnishing, delivery and installation of new acoustical shell system

More information

SPECIFICATIONS SYSTEMS MATCHING EXISTING. This Matching Existing Furniture Contract will be for the following Manufacturer s only:

SPECIFICATIONS SYSTEMS MATCHING EXISTING. This Matching Existing Furniture Contract will be for the following Manufacturer s only: SPECIFICATIONS SYSTEMS MATCHING EXISTING This Matching Existing Furniture Contract will be for the following Manufacturer s only: Haworth Herman Miller Steelcase Global Hon Kimball Allsteel Knoll Maxon

More information

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 SECTION 08 32 20 CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS [OR WOOD] PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

SECTION TRESPA ATHLON SOLID COMPOSITE CASEWORK

SECTION TRESPA ATHLON SOLID COMPOSITE CASEWORK SECTION 064115 TRESPA ATHLON SOLID COMPOSITE CASEWORK PART 1 GENERAL 1.01 SECTION INCLUDES A. Solid composite casework. 1.02 RELATED SECTIONS A. Documents affecting work in this section includes but is

More information

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL Model # Series 7200-S Top Mounting Plate Electrical Junction Box Located Behind Removable Upper Panel Medical Gas Connections Lower Mounting Plate OVERVIEW

More information

INCLINATOR ELEVETTE. Planning Guide. CABLE DRUM 1000 lb. (454 Kg) AMERICA S MOST CUSTOMIZABLE ELEVATOR

INCLINATOR ELEVETTE. Planning Guide. CABLE DRUM 1000 lb. (454 Kg) AMERICA S MOST CUSTOMIZABLE ELEVATOR INCLINATOR ELEVETTE Planning Guide CABLE DRUM 1000 lb. (454 Kg) AMERICA S MOST CUSTOMIZABLE ELEVATOR Introduction It started over 90 years ago with a passion to help an ailing friend access his multi-level

More information

REQUEST FOR PROPOSAL FOR UTILITY TRUCK BOX. Instructions

REQUEST FOR PROPOSAL FOR UTILITY TRUCK BOX. Instructions REQUEST FOR PROPOSAL FOR UTILITY TRUCK BOX 1. Requesting Entity. Instructions This Request For Proposal (this RFP ) is made by the Village of Rantoul, Champaign County, Illinois, having its principal office

More information

PHYSICAL FACILITIES Consultant s Handbook Division 27 COMMUNICATIONS 0000 COMMUNICATIONS

PHYSICAL FACILITIES Consultant s Handbook Division 27 COMMUNICATIONS 0000 COMMUNICATIONS 1 Introduction 1.1 In the design of Telecommunications systems in Purdue facilities, the overall consideration should be to understand and treat telecom as a utility. It should be assumed that all new

More information

Technical Furniture Group

Technical Furniture Group Technical Furniture Group Technical Furniture Comdata Racks Electronic Enclosures FURNISHING INGENUITY Furnishing Ingenuity 2 At Kewaunee, we turn innovation and a century s worth of experience into adaptable

More information

CEILING MOUNTED ARTICULATING JIB CRANE

CEILING MOUNTED ARTICULATING JIB CRANE SECTION 14657 CEILING MOUNTED ARTICULATING JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station

More information

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466 BUSWAY LOW VOLTAGE (POW-R-WAY III) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein

More information

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2 MiT MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE OF MPL Digital Pedestal Manual Version 0.2 MOVING image TECHNOLOGIES, LLC. 17760 Newhope St. Fountain Valley, CA

More information

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System SECTION 13096 RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13096-1 RF MODULAR PAN SYSTEM PART 1 GENERAL 1.1

More information

A. Submit the following in addition to the standard requirements.

A. Submit the following in addition to the standard requirements. SECTION [13120] OMNIFLEX 300 MODULAR WALL SYSTEM SECTION 1 GENERAL 1.01 SECTION INCLUDES A. This Section specifies all requirements necessary to furnish and install a complete modular wall system including,

More information

SUGGESTED SPECIFICATION for Low Voltage (600V) Generator Paralleling Switchboard

SUGGESTED SPECIFICATION for Low Voltage (600V) Generator Paralleling Switchboard SUGGESTED SPECIFICATION for Low Voltage (600V) Generator Paralleling Switchboard PART 1 GENERAL 1.1 Scope A. The intent of this specification is to provide power control for the parallel operation of generator

More information

Communications Page 1 of 9

Communications Page 1 of 9 Page 1 of 9 Last Update: April 23 rd, 2014 Introduction Design In the design of Telecommunications systems in Purdue facilities, the overall consideration should be to understand and treat telecom as a

More information

CR-3000 Car Rotator Capacity 3,000 lbs Installation Manual 2016 Mar

CR-3000 Car Rotator Capacity 3,000 lbs Installation Manual 2016 Mar Car Rotator Capacity 3,000 lbs Installation Manual 2016 Mar INDEX 1. OWNER / USER RESPONSIBILITIES---------------------------------------- PAGE 3 2. SAFETY PROCEDURES---------------------------------------------------------

More information

AUTOMATIC VERTICALLY RETRACTABLE Skyfold Mirage ACOUSTIC INTERIOR GLASS WALL Section Page 1 October 2017

AUTOMATIC VERTICALLY RETRACTABLE Skyfold Mirage ACOUSTIC INTERIOR GLASS WALL Section Page 1 October 2017 Page 1 PART 1: GENERAL 1.01 Related Documents: A. All applicable provisions of the Bidding and Contract Requirements, and Division 1 - General Requirements shall govern the work under this section. 1.02

More information

Division 16 Sections for electrical service for elevators to and including disconnect and fused switches at machine room.

Division 16 Sections for electrical service for elevators to and including disconnect and fused switches at machine room. A+ ELEVATORS & LIFTS An A+ Connection Company Phone: 888-444-APLUS (2758) Fax: 888-444-9377 Email: info@aplusconnection.com Web: www.aplusconnection.com GEAR DRIVE An A+ Connection Company SECTION 14202

More information

REQUEST FOR PROPOSAL FOR DISPATCH CENTER CONSOLE FURNITURE Bossier Parish Communications District 1 Benton, LA.

REQUEST FOR PROPOSAL FOR DISPATCH CENTER CONSOLE FURNITURE Bossier Parish Communications District 1 Benton, LA. REQUEST FOR PROPOSAL FOR 9-1-1 DISPATCH CENTER CONSOLE FURNITURE Bossier Parish Communications District 1 Benton, LA. Anticipated furniture installation time, mid January. Notarize the pricing page, and

More information

WALL MOUNTED ARTICULATING JIB CRANE

WALL MOUNTED ARTICULATING JIB CRANE SECTION 14656 WALL MOUNTED ARTICULATING JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station and

More information

MODEL: IMPULSE - DUAL SIT/STAND CONSOLES

MODEL: IMPULSE - DUAL SIT/STAND CONSOLES 2015 WINSTED CORPORATION 1) GENERAL DESCRIPTION 1.1 Impulse Dual Sit/Stand Consoles. See Appendix A - D for typical styles and measurements. 1.2 The contractor shall supply a system capable of supporting

More information

CUSTOM PRODUCTS & SERVICES, INC. PH: FAX: WEBSITE:

CUSTOM PRODUCTS & SERVICES, INC. PH: FAX: WEBSITE: INTEGRATED CABLE MANAGEMENT SYSTEM FOR OFFICES, CLASSROOOMS, MEDIA CENTERS, MANUFACTURING FACILITIES, 911 CENTERS, DISPATCH ROOMS, CONTROL ROOMS DISTRIBUTED BY CUSTOM PRODUCTS & SERVICES, INC. PH: 888-444-1202

More information

SHERIDAN SEATING INC.

SHERIDAN SEATING INC. SHERIDAN SEATING INC. ARENA SEATING SPECIFICATIONS PART 1 GENERAL 1.1 Description A. Scope 1. Telescopic seating systems comprised of multi-tiered rows of seats, deck components and risers on interconnected,

More information

Product Guide Specification

Product Guide Specification February 2015 528 Pioneer Parkway Clare, Michigan 48617 Toll Free 800-631-0212 Website www.tranquilsystems.com E-mail sales@tranquilsystems.com Product Guide Specification Tranquil Adapt Walls glass partitions

More information

SECTION MODULAR GALVANIZED RF SHIELDING SYSTEM SPECIFICATIONS

SECTION MODULAR GALVANIZED RF SHIELDING SYSTEM SPECIFICATIONS SECTION 13096 MODULAR GALVANIZED RF SHIELDING SYSTEM SPECIFICATIONS Prepared by: NELCO 125 Chenoweth Lane, Ste. 206 Louisville, KY 40207 (502) 899-3726 13096-1 MODULAR GALVANIZED RF SHIELDING SYSTEM PART

More information

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 102239 - FOLDING PANEL PARTITIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment. RM140A-R3 RM140A-M-R3 RM145A-R3 RM145A-M-R3 Small Office/Home Office (SOHO) Cabinets Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment. Fit under most desktops in the

More information

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following: SECTION 10501 PERSONNEL DUTY LOCKERS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 specifications

More information

UBC Technical Guidelines Division Edition Furnishings Page 1 of 1 INDEX

UBC Technical Guidelines Division Edition Furnishings Page 1 of 1 INDEX UBC Technical Guidelines Division 12 2018 Edition Furnishings Page 1 of 1 INDEX Section 12 00 00 Section 12 20 00 Section 12 30 00 Section 12 35 53 Furnishings Window Coverings and Blinds Fabricated Casework

More information

City of Olivette Request for Qualifications Furniture Procurement and Installation April 26, 2016

City of Olivette Request for Qualifications Furniture Procurement and Installation April 26, 2016 General Information The City of Olivette (City) is seeking a qualified firm to provide procurement, installation, and warranty service related to furnishings and furniture at the City s new Municipal Center.

More information

SUBSTITUTION REQUEST (After the Bidding/Negotiating Phase)

SUBSTITUTION REQUEST (After the Bidding/Negotiating Phase) SUBSTITUTION REQUEST (After the Bidding/Negotiating Phase) Project: Substitution Request Number: From: To: Date: A/E Project Number: Re: Contract For: Specification Title: Section: Page: Description: Article/Paragraph:

More information

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION

More information

This guide can be used to prepare a specification for incorporating wall bracket jib cranes into a competitively bid construction project.

This guide can be used to prepare a specification for incorporating wall bracket jib cranes into a competitively bid construction project. SECTION 14654 WALL BRACKET JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station and industrial

More information

ADDENDUM NO. 5. April 9, 2014

ADDENDUM NO. 5. April 9, 2014 CLASSROOM & ACADEMIC OFFICE BUILDING PROJECT NO.: 900290 Project Name: CLASSROOM & ACADEMIC OFFICE BUILDING Project No.: 900290 ADDENDUM NO. 5 to the CONTRACT DOCUMENTS April 9, 2014 I. Bidder acknowledges

More information

OPERATING PROCEDURE NO. 310

OPERATING PROCEDURE NO. 310 OPERATING PROCEDURE NO. 310 Related Operating Procedures: 310A; 310B; 310C; 310D SUBJECT: Conditions of Service Issued: February 10, 2014 Revised: March 28, 2016 OBJECTIVE: To establish the rules, regulations

More information

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project. GORBEL PRODUCT SPECIFICATIONS 2010 Gorbel, Inc., P.O., Box 593, Fisher, New York 14453-0593 PHONE: 800-821-0086, FAX: 585-924-6273; WEBSITE: www.gorbel.com November SECTION 41 22 31PRIVATE FREE STANDING

More information

A. Basket Cable Tray: A fabricated structure consisting of wire mesh bottom and side rails.

A. Basket Cable Tray: A fabricated structure consisting of wire mesh bottom and side rails. SECTION 16714 - COMMUNICATIONS EQUIPMENT ROOM FITTINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

A. Basket Cable Tray: A fabricated structure consisting of wire mesh bottom and side rails.

A. Basket Cable Tray: A fabricated structure consisting of wire mesh bottom and side rails. SECTION 27 11 00 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

FS300 (1,500 lb) Specifications For HPL Covered Panels On Bolted Stringer System

FS300 (1,500 lb) Specifications For HPL Covered Panels On Bolted Stringer System FS300 (1,500 lb) Specifications For HPL Covered Panels On Bolted Stringer System NOTE: These specifications conform to CSI MasterFormat 2004/2005 Edition, AIA MasterSpec Section 096900 and to CSI MasterFormat

More information

Laboratory Product Catalog

Laboratory Product Catalog Laboratory Product Catalog Table of contents Page Sovella Lab Benches 5 Heart and soul of the laboratory NEW! TL Advantage Lab Bench 9 Accessories 12 Sovella Wall Shelving 19 Storage Solutions Reagent

More information

Workstations & Tool Supports

Workstations & Tool Supports Let our modular construction and experience help you equip your workstation to meet your needs! Standard Workstation #44399 Shown Complete Pallet Transport Workstation #44499 Shown Popular options we can

More information

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

1. Vertical reciprocating conveyor, Hydraulic straddle VRC. PART 1: GENERAL 1.01 Section Includes: 1. Vertical reciprocating conveyor, Hydraulic straddle VRC. a. Machine, controller, platform, structural steel hoist frame. b. Wire mesh enclosure and gates. Related

More information

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers) SECTION 10 51 00 Summit Phenolic Lockers (Solid Phenolic Lockers) Part 1-General 1.01 Summary A. Section includes: solid phenolic lockers solid phenolic benches 1.02 Submittals A. Submittals: Comply with

More information

ViewPoint Series. features: specifications: monitoring console system. what great systems are built on.

ViewPoint Series. features: specifications: monitoring console system. what great systems are built on. Series monitoring console system flexible, scalable system has been designed for optimum operator effectiveness features: Fully welded bays provide a heavy-duty structure that can be assembled quickly

More information

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651 SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651 PART 1 GENERAL 1.1 DESCRIPTION A. Work Included: 1. Furnish all labor and materials to complete the fabrication of detention windows

More information

MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE

MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE ELECTRICAL SPECIFICATION 1453 DIVISION OF ENGINEERING DEPARTMENT OF TRANSPORTATION CITY OF CHICAGO REVISED MARCH 14, 2013 MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE SUBJECT 1. This specification covers

More information

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

1. Vertical reciprocating conveyor, Hydraulic straddle VRC. PART 1: GENERAL 1.01 Section Includes: 1. Vertical reciprocating conveyor, Hydraulic straddle VRC. a. Machine, controller, platform, structural steel hoist frame. b. Wire mesh enclosure and gates. Related

More information

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

B. Polyethylene samples shall be submitted for Owner approval of color and quality. Glass Rail ENGINEERED DASHERBOARD SPECIFICATIONS PART 1 - GENERAL 1.01 PROJECT SCOPE A. Contractor shall furnish and install one complete set of steel framed dasherboards as indicated on the drawings and

More information

International, Inc Evans Ave. Phone: Akron, OH Fax: SPECIFICATIONS

International, Inc Evans Ave. Phone: Akron, OH Fax: SPECIFICATIONS International, Inc. 1019 Evans Ave. Phone: 888-566-5400 Akron, OH 44305 Fax: 888-566-5415 Website: www.mwintl.net Email: sales@mwintl.net SPECIFICATIONS This section is based on the FC-300 Demountable

More information

SYSTEM XXI PANEL SYSTEM

SYSTEM XXI PANEL SYSTEM SYSTEM XXI PANEL SYSTEM WASHINGTON STATE CORRECTIONAL INDUSTRIES MAXIMIZE YOUR ENVIRONMENT The team workspace poses unique challenges for furniture designers: access with privacy; storage that doesn t

More information

Request for Bids. At The Greenville-Spartanburg International Airport

Request for Bids. At The Greenville-Spartanburg International Airport Request for Bids At The Greenville-Spartanburg International Airport Addendum No. 2 June 27, 2011 All Bidders shall include with their bid submittal a signed statement indicating they have reviewed and

More information

ELEVATORS & SERVICE LIFTS FREIGHT HOIST MAST LIFTS FREIGHT HOIST SCISSOR LIFTS ELEVATING DOCK SCISSOR LIFTS DOCK LEVELLERS

ELEVATORS & SERVICE LIFTS FREIGHT HOIST MAST LIFTS FREIGHT HOIST SCISSOR LIFTS ELEVATING DOCK SCISSOR LIFTS DOCK LEVELLERS ELEVATORS & SERVICE LIFTS FREIGHT HOIST MAST LIFTS FREIGHT HOIST SCISSOR LIFTS ELEVATING DOCK SCISSOR LIFTS DOCK LEVELLERS McGrath Industries Ltd. 2017. All rights reserved. Ed04, CJM. ELEVATORS SERVICE

More information

N-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System

N-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System Version 5.22.13 N-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System OPTIONS ARE LISTED IN BOLD, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER

More information