1 Product Manual A Sterile Processing User s Guide Safety, Assurance, Innovation, & Quality enabling perioperative professionals to achieve higher standards of performance and enhanced patient safety Phone:866-ONE-TRAY Copyright All rights reserved. Not to be duplicated without express permission of the author 1
2 ContentsII and proprietary Welcome to ONE TRAY...3 ONE TRAY System Configurations...4 Sterilization Guidelines...5 Care & Use of Your ONE TRAY System Preparation...6 Opening.. 7 Filter Installation....8 Loading..10 Closing & Seal Installation Sterilization & Handling..14 Opening...15 Removing Contents Inspection Checklist Disassembly. 17 Cleaning Warranty Proudly Made in the U S A 2
3 Welcome to ONE TRAY Just-In-Time Terminal Sterilization System We very much appreciate your decision to purchase the ONE TRAY Sealed Container System. ONE TRAY Sealed Containers are 510(k) cleared by the FDA for the rapid sterilization of temperature tolerant surgical devices; includes a 48 hour shelf. ONE TRAY Sterilization Containers are intended for the terminal sterilization of surgical devices and supplies; including instrumentation with lumens 3mm in diameter or larger, with lengths up to 400mm.,In addition, ONE TRAY complies with AAMI and AORN guidelines for the safe transport and assured delivery of the contents with tamper evident security in a sealed container. ONE TRAY containers are a reusable device with base, cover, and deck plate constructed of hard anodized aluminum to prevent corrosion. With proper care and handling, ONE TRAY will provide many years of effective and reliable service. The performance and intended use of ONE TRAY Sealed Sterilization Containers should comply at all times with the methods of use and sterilization guidelines as recommended by AAMI (Association for the Advance of Medical Instrumentation), AORN (Association of perioperative Nurses), ASHCSP (American Society of Healthcare Central Service Professionals), NIHSPO (National Institute for the Certification of Healthcare Sterile Processing and Distribution Personnel), IAHCSMM (International Association of Healthcare Central Service Material Management) and the manufacturer of those devices being sterilized. Proudly Made in the U S A by 3
4 is available in the following components and configurations: Product # ONE TRAY 21 Model Description M long x 12 wide 4 working height M-2106 M-2108 Product # M-2404 M long x 12 wide 6 working height 21 long x 12 wide 8 working height ONE TRAY 24 Model Description 24 long x 12 wide 4 working height 24 long x 12 wide 6 working height M long x 12 wide 8 working height Product # ONE TRAY Accessories Description OTK-210 RPS-004 RPS-005 RPS-015 RPS-030 RPS-055 RPS-100 ONE TRAY Processing Kit 100 kits per box, 2 boxes per case Each kit contains - 3 Hydrophobic Filters, Class 5 Integrator, 2 Load I. D. cards w Indicator Dot & 2 Tamper Evident Seals. RAPID Processing Solution RAPID Processing Solution Case of Four 1 Gallon Bottles RAPID Processing Solution Five Gallon Pail RAPID Processing Solution Fifteen Gallon Drum RAPID Processing Solution Thirty Gallon Drum RAPID Processing Solution Fifty five Gallon Drum RAPID Accurate Measure Hand Pump Proudly Made in the U S A 4
5 Just-In-Time Terminal Sterilization ONE TRAY is validated and 510(k) cleared for the rapid processing of temperature tolerant surgical instrumentation by gravity or pre-vacuum sterilization cycles with a total gross weight (container plus contents) not to exceed 25 lbs. This includes sterilization of lumens of 3 mm in diameter, or larger; with lengths of up to 400 mm according to the times and temperatures listed. ONE TRAY is 510(k) cleared by the FDA only for use in the following cycles as established during validation testing performed in an AAMI ST-08 compliant steam sterilizer: Steam Sterilization Cycles Pre-Vacuum Temperature 270 F Exposure Time 4 Minutes Cycle Dry Time Not Required Cycle Cool Time Not Required Gravity Temperature 270 F Exposure Time Minutes Cycle Dry Time Not Required Cycle Cool Time Not Required (do not process ONE TRAY using pulsed flash cycles) Items rapidly processed in ONE TRAY have a 30 Day Shelf Life! 5
6 Preparation 1. Thoroughly inspect container for dents or damage that may affect performance. 2. Place container on stable and level surface at height that facilitates safely opening the cover 3. Open the container by removing the cover according to the instructions illustrated in the table on the next page. 4. Confirm the rim of container base is free of burrs and dents. 5. Inspect to insure lid gasket is free of cracks, tears, imperfections or defects and is completely seated in channel. 6. Confirm that the cover properly mounts on container base and seals in place. 6
7 Opening Method 1 2 Cover on base with latch handles in locked position Grasp cover latch handles at each end of container 3 4 Simultaneously pull out and upward on cover latch handles at each end Latch is disengaged from base as the cover latch handles are raised 5 6 Clasp releases from the base as both cover latch handles are raised Latch handles are fully open and cover removed from base 7
8 The validated performance and 510(k) Clearance of ONE TRAY is in effect ONLY with the exclusive use of ONE TRAY Processing Kits and deck plate. Filter Installation 1. A single disposable ONE TRAY filter element is required for each of the vented areas (one in container lid and two in container base). 3. Each disposable filter element should be inspected to confirm the absence of imperfections or defects such as puncture holes or tears, etc. 4. Each disposable filter element must completely cover the grooved channel surrounding the vented area. 5. Confirm the notched end of filter cover is properly oriented with either set of stand-off posts. 6. Insert notched end of filter cover under stand-off posts. 7. Position keyholes in filter cover slide-bar over an opposing set of stand-off posts. 8. Apply downward pressure on filter cover and push the slide bar completely forward into a fully locked position under the standoff posts. Use all of the items contained in the ONE TRAY Processing Kit For each processing cycle. 8
9 Filter Installation 1 2 Use ONE TRAY Processing Kit Confirm vent gasket is clean and undamaged 3 4 Position filter to completely cover the vent gasket Insert notched end of filter cover under stand-off posts 5 6 Position keyholes in slide-bar over the stand-off posts 9 Apply downward pressure and move the side-bar into the locked position
10 Loading the Container 1. ALWAYS prevent contents from contacting the cover. 2. Avoid obstructing the vent and filter cover with pliable items. 4. Per AAMI guidelines, a chemical indicator or integrator should be used within each assembled set according to organizational policy. ONE TRAY recommends the use of a Class 5 Multi-Parameter Steam Sterilization Integrator with all rapid sterilization cycles. 5. When loading the container, only the ONE TRAY deck plate has been specifically designed for the direct placement of items or insertion of modular instrument organizing trays. Complex instruments should be prepared and sterilized according to the manufacturers written instructions 10
11 Container Assembly & Security 1. Inspect rim of container to confirm there are no dents or burrs. 2. Inspect cover gasket to confirm there are no cracks, tears, imperfections, or defects. 3. Confirm that all filter covers are securely in place. 4. Place cover on container base evenly and confirm proper fit between cover and base. 5. Secure cover by simultaneously pressing down to engage the latch at each end. 6. Properly complete both content I. D. cards and insert into slot on latch plate at each end of container. 7. Insert a ONE TRAY tamper evident seal through the latch at both ends of container. The validated performance and 510(k) Clearance of ONE TRAY is in effect ONLY with the exclusive use of ONE TRAY Processing Kits and deck plate. 11
12 Seal Method 1 2 Insert narrow end of seal through the bracket Position tagged end of seal in bracket 3 4 Gasp narrow end of seal Insert narrow end of seal into flat side of seal 5 6 Push narrow end through opening on tag Seal placed on bracket at both ends of container 12
13 Sterilization & Handling 1. Place a single ONE TRAY container in a level horizontal position on each shelf within the sterilizer. 2. Confirm that all vented areas are not obstructed. DO NOT STACK DURING STERILIZATION 3. ONE TRAY is validated for rapid processing by gravity or prevacuum sterilization of total gross weight (container plus contents) not to exceed 25 lbs. This includes sterilization of lumens of 3 mm in diameter or larger with lengths of up to 400 mm. ONE TRAY is validated for use in the following cycles: Pre-vacuum F Gravity F CAUTION! 4. Following sterilization avoid unprotected contact with the hot container by using insulated handles to lift and transport. 5. After each Sterilization Cycle retain any Steam Integrators used. 6. Retained condensed moisture is normal and expected and may vary by by load composition does not compromise the sterility of contents. Items rapidly processed in ONE TRAY have a 30 Day Shelf Life! 13
14 Closing Method 1 2 Align the cover with base Mount the cover properly onto the base 3 4 Position lid onto base with latch handles in upright position Simultaneously lower both latch handles into horizontal position 5 6 Push down on both handles to fully engaged clasp Container is sealed when both latch handles are in locked position 14
15 Sterile Delivery & Presentation 1. Place container on level and stable surface at height that facilitates aseptic opening. 2. Check that external dot indicators on the load content card(s) have turned the appropriate color. 3. Inspect load content card(s) to verify identification of the correct Instrument set. 4. Check to insure tamper proof seals are intact by gently tugging on each seal. 6. Before opening, inspect container and confirm presence of filters in all three vents. 7. Place thumbs on upper surface of cover above latch handles. 8. Place fingers under lid latch handles at both ends of container. 9. Break the tamper evident seals by firmly and simultaneously pulling up on both lid latch handles. 10. Aseptically lift cover off the base of the container and inspect for proper placement of filter and installation of filter cover on lid. 11. Remove lid filter cover and confirm filter is undamaged. All clinical research and validation testing of ONE TRAY Containers was performed with ONE TRAY components, filter elements and tamper evident seals. 15
16 Removing Sterile Contents 1. Before touching the insert tray or contents of the container, properly trained personnel must check internal sterilization indicators following facility guidelines to verify acceptable results. 2. Securely grasp the contents, or modular organizing tray handles and remove in an aseptic manner without touching the outside of the container. 3. Before placing contents on the sterile field, properly trained personnel must inspect the placement of both filter retention plates and integrity of each filter element on both vents in the floor of the container base. 4. After container is empty, replace the container lid and secure the clasps to the container base using the latch handles. Inspection Check List Contents should be considered non-sterile if any of the following conditions are present: A tamper evident seal is not intact or is missing from either latch. A filter retention plate is dislodged. A filter does not completely cover the vented area. Integrity of a filter element has been compromised (i.e. punctured, torn, etc.). Lid gasket is damaged or not properly seated in channel. Lid and or base are damaged and do not seat properly. 16
17 Disassembly 1. Remove and discard all disposables (filters, load content cards, etc.). 2. Inspect container cover and base for dents or damage that may affect performance. 3. Confirm the rim of the container base is free of burrs and dents. 4. Inspect that cover gasket is free of cracks, tears and is properly seated in channel on the cover. 5. Confirm that cover properly fits on container base. Cleaning 1. ONE TRAY containers and components may be safely processed in a mechanical washer/decontaminator, cart washer or processed manually. 2. Mechanical or automatic processing should follow the directions of the equipment manufacturer with ONE TRAY cover and base positioned to prevent water collection. 3. For optimal cleaning results use a neutral ph detergent. 4. NEVER clean the container with abrasives or wire brushes. 5. All components should be secured or enclosed inside a rack or basket with no protrusions to prevent damage during processing. 6. Confirm that all components are cool before handling. 7. If necessary, dry container and components by wiping with a soft dry cloth. 17
18 Appendix Manufacturer s Warranty ONE TRAY Sealed Sterilization Containers are guaranteed for the life of the product to be free of functional defects in workmanship and materials when used normally as recommended for their intended purpose in conjunction with ONE TRAY filters, tamper evident seals, and deck plate. The cover gasket is warranted for a period three years from the date of purchase. Any product determined to be defective upon delivery will be repaired or replaced with no charge to the customer at the sole discretion of ONE TRAY. Used product may not be returned for credit. Any and all returns must receive prior authorization from ONE TRAY and include documentation that the returned product was properly cleaned and decontaminated. This warranty is valid only to the original purchaser. The following exclusions apply to this warranty that include, but are not limited to: Conditions resulting from; negligence, misuse and improper cleaning, handling, closing or opening. Use of accessories (tamper evident seals, filters, etc.) not supplied by ONE TRAY. Damage from excessive force or pressure. Use of abrasive cleaning agents or harsh detergents that are not neutral ph. Modification(s) to the container. Effects from fire, flood or other unpredictable event not under the control of ONE TRAY. LIMITS OF USE ONE TRAY containers have been validated to perform for five hundred steam sterilization cycles. The actual limits of reuse for the ONE TRAY are based upon the proper handling, use, care and cleaning of the ONE TRAY. Users may experience limits that are greater or less based upon their use of the ONE TRAY. 18
REUSABLE STERILIZATION CONTAINER SYSTEM.
REUSABLE STERILIZATION CONTAINER SYSTEM. Validated container system for the DePuy Synthes Companies (Trauma, CMF, and Spine) instrument and implant sets. USER'S MANUAL TABLE OF CONTENTS INTRODUCTION Product
More informationAmalgatome SD Sterilization Tray User Guide
Amalgatome SD Sterilization Tray User Guide EXSURCO MEDICAL 10804 GREEN ROAD WAKEMAN, OH 44889 PN: X101489 REV. B This page intentionally left blank. AMALGATOME SD STERILIZATION TRAY USER GUIDE Instructions
More informationAesculap SterilContainer System Instructions for Use Steam, Ethylene Oxide and Vapor Hydrogen Peroxide Sterilization Modalities
Aesculap SterilContainer System Instructions for Use Steam, Ethylene Oxide and Vapor Hydrogen Peroxide Sterilization Modalities Instructions for Use As of June 2016 Blank Page Table of Contents CHAPTER
More information3034 Owen Drive Antioch, TN USA Fax: Maybachstraße 10. Revised 01/17
CLN VersaPak Modular Instrument Tray Symmetry Surgical Inc. 3034 Owen Drive Antioch, TN 37013 USA 1-800-251-3000 Fax: 1-615-964-5566 www.symmetrysurgical.com EC REP Symmetry Surgical GmbH 78532 Tuttlingen,
More informationIMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY
IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY SHELF MAXIMUM WEIGHT CAPACITY: 908 kg / 2000 lb EVENLY DISTRIBUTED. ENTIRE UNIT MAXIMUM WEIGHT CAPACITY: 3629 kg / 8000 lb EVENLY DISTRIBUTED. CONCENTRATED
More informationAre My Rigid Containers. Maintaining Sterility?
Are My Rigid Containers Maintaining Sterility? 1 Are My Rigid Containers Maintaining Sterility? Objectives 1. List the observations to be taken each time a rigid container is prepared for use 2. Describe
More informationGuide for Cleaning, Sterilization and Storage of Reusable Introducers
Guide for Cleaning, Sterilization and Storage of Reusable Introducers M Manufactured by: Caldera Medical, Inc. 5171 Clareton Drive Agoura Hills, CA 91301 U.S. Toll Free: 866-4-CALDERA Telephone: 818-879-6555
More information5-1/2 inch Vinyl Handrail Model(s): BHRVE55C-P
5-1/2 inch Vinyl Handrail INSTALLATION, OPERATION & MAINTENANCE MANUAL Table of Contents 5-1/2 inch Vinyl Handrail Table of Contents General Description...3 Installation...4-7 Parts List...8 Maintenance...9
More informationGuide for Cleaning, Sterilization and Storage of Introducers for Caldera Medical Implants
Guide for Cleaning, Sterilization and Storage of Introducers for Caldera Medical Implants M Manufactured by: Caldera Medical, Inc. 5171 Clareton Drive Agoura Hills, CA 91301 U.S. Toll Free: 866-4-CALDERA
More informationPLC-P-FM Manual Pail Lid Closing Press Instruction Manual
Vestil Manufacturing Co. 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-1339 Web: www.vestilmfg.com e-mail: info@vestil.com
More informationLoaner Instrumentation
Loaner Instrumentation Objectives Discuss issues and concerns relative to loaner instrument sets Discuss guidance from a professional organization paper and AAMI Examine the steps to take in managing the
More informationGF6580BH-1 PATRIOT LIBERTY QUARTER RAILS:
GF6580BH-1 PATRIOT LIBERTY QUARTER RAILS: INSTALLATION & OPERATION INSTRUCTIONS FOR PATRIOT BED PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE Info: The most current version of these instructions can be
More informationFIXED CEILING COLUMN. Installation Manual FIXED CEILING COLUMN
FIXED CEILING COLUMN Installation Manual FIXED CEILING COLUMN INTRODUCTION Location, sequence of services and orientation of Surgical Ceiling Columns are specified on the building plans. Be certain installation
More informationFacility: Sterile Processing Assessment Date: CRITERIA ANSI/AAMI COMPLIANT Number Y N N/A Point of Use Gross contaminant is removed with
Point of Use 6.2-6.3 Gross contaminant is removed with water Instruments are sorted Sharps removed Instruments placed back in original container Un-used instruments placed in bottom of basket Towel placed
More informationPLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE
GF6590BH-1 PATRIOT LIBERTY HALF NO-GAP HEAD RAILS: INSTALLATION & OPERATION INSTRUCTIONS FOR PATRIOT BED PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE Info: The most current version of these instructions
More information6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.
6 Closet light Model 95792 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo,
More informationWe ve built a STRONG CASE. for changing the way you sterilize. Reusable Sterilization Container System
We ve built a STRONG CASE for changing the way you sterilize. Reusable Sterilization Container System Reusable Sterilization Container System Introducing the DePuy Synthes REUSABLE STERILIZATION CONTAINER
More informationexecutive safe with Override Key Limited Warranty Operation & Installation Guide Read These Instructions Very Carefully! ENGLISH
Limited Warranty BRK Brands, Inc., ( BRK ) warrants that for a period of five (5) years from the date of purchase, this product will be free from defects in material and workmanship. BRK, at its sole option,
More informationQuality Assurance with Rigid Containers Katrina Simpson, M.A., CST, CSPDT
Page 2 I HEARD IT THROUGH THE STEAMLINE Quality Assurance with Rigid Containers Katrina Simpson, M.A., CST, CSPDT Objectives: Discuss various quality assurance issues regarding rigid containers. Discuss
More informationUnloading, Storage, Distribution, Transportation and Aseptic Presentation of Sterile Items
Unloading, Storage, Distribution, Transportation and Aseptic Presentation of Sterile Items Comprehensive guide to steam sterilization and sterility assurance in health care facilities (ANSI/AAMI ST79:2006)
More informationVHSR-SERIES RACKS FOR SHEET MATERIAL
VESTIL MANUFACTURING CORP. 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-1339 www.vestilmfg.com e-mail: sales@vestil.com
More informationGeneral Guidelines. Instructions for Part # WP Safety. It is the user s responsibility to read and follow all instructions.
General Guidelines It is the user s responsibility to read and follow all instructions. Instructions for Part # WP-48-1000 Keep these instructions with the product at all times and review before each use.
More informationNVD-40 NEAR VERTICAL DRUM LIFTER INSTRUCTION MANUAL
VESTIL MANUFACTURING CORP. 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-1339 www.vestilmfg.com e-mail: info@vestil.com
More informationBBL-4 FORK-MOUNTED BULK BAG LIFTER USE AND MAINTENANCE MANUAL
VESTIL MANUFACTURING CORP. 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-1339 www.vestilmfg.com e-mail: sales@vestil.com
More informationQUAD Rectangular Hinged Door Shower Enclosure Installation Instructions
QUAD Rectangular Hinged Door Shower Enclosure Installation Instructions IMPORTANT Please read carefully the following instructions before installing your shower enclosure. If you have any questions on
More informationDCL-Series Drum Carriers Instruction Manual
Vestil Manufacturing Corp. 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-1339 www.vestilmfg.com e-mail: sales@vestil.com
More informationSYSTEM 600 GENERAL MAINTENANCE AND ADJUSTMENT GUIDE
SYSTEM 600 GENERAL MAINTENANCE AND ADJUSTMENT GUIDE If you follow a routine maintenance schedule your system 600 will give you years of reliable service with a minimum of down time. This guide outlines
More informationPREMIER V Bucko Cast In Place
PREMIER V Bucko Cast In Place 28972 R. Ave Adel, Iowa 50003 800-343-9370 1850 West Adriatic Place Englewood, Colorado 80110 303-935-4679 Visit Monarch Materials Group, Inc. at www.monmatgrp.com Premier
More informationST 19 Aluminium Manually Controlled Electric Model
ST 19 Aluminium Manually Controlled Electric Model Operators Manual Issue 5 For correct operation of this autoclave it is essential that the chamber be filled with water up to the height of the studs before
More information3.0. For Home, Haven, Standard & Heavy Duty Series. Aluminum Prebuilt Fence ALUMFENCEA_BOM V3 2/14. Owner's Manual Installation Instructions.
Aluminum Prebuilt Fence ALUMFENCEA_BOM V3 2/14 Owner's Manual Installation Instructions PLEASE READ OWNER'S MANUAL COMPLETELY BEFORE ASSEMBLING YOUR FENCE. ALL STATED SIZES ARE NOMINAL DIMENSIONS. For
More informationSTP Mount Series. Installation Manual. STP-LSCR-MAN 2017 Edition v1.0. For models: STP-SCR/045 STP-SCR/060 STP-SCR/070 STP-LCR/090 STP-LCR/120
Installation Manual STP-LSCR-MAN 2017 Edition v1.0 For models: STP-SCR/045 STP-SCR/060 STP-SCR/070 STP-LCR/090 STP-LCR/120 Table of Contents Introduction... 1 Customer Support... 1 Tools Required... 2
More informationPallet Jack 4,400 Lbs Capacity Model #31001
SKU # 217-0162 Pallet Jack 4,400 Lbs Capacity Model #31001 Owner s Manual and Assembly Instructions Questions? Problems? DO NOT RETURN TO STORE Please call our customer help line: (888) 315-3080 M-F 8-5
More informationSterile Packaging & The End User
Sterile Packaging & The End User HealthPack Conference March 8-10, 2011 Cincinnati, Ohio Presented by: Ray Taurasi MBA, CRCST, CHL, FCS, ACE director clinical sales and services Healthmark Industries Inc.
More informationVN Series Floor Scale Instruction Manual
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com VN Series Floor Scale Instruction Manual VN Series Floor Scale EN-1 INTRODUCTION
More informationLAHAINA. Lahaina Showerspa Model #1030 Installation Instructions
LAHAINA Lahaina Showerspa Model #1030 Installation Instructions Lahaina ShowerSpa Model #1030 Please Read The Following Instructions COMPLETELY Before Beginning! Our goal is to ensure your installation
More informationINSTALLATION MANUAL SURFACE-MOUNTED HEADWALL
INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL Model # Series 7200-S Top Mounting Plate Electrical Junction Box Located Behind Removable Upper Panel Medical Gas Connections Lower Mounting Plate OVERVIEW
More informationTABLE OF CONTENTS. Vacuum Cleaner. Model No. MC-CG Bagless Canister Red North America
Order No.: MAC1412002CE Vacuum Cleaner Model No. MC-CG902-02 Bagless Canister Red North America TABLE OF CONTENTS PAGE 1 Specifications ----------------------------------------------------- 2 2 Disassembly
More informationSby SR Instruments, Inc.
Part No.: MAN947IFS_170629 Page 1 of 12 Sby SR Instruments, Inc. SRV947IFS REMOTE DISPLAY PLATFORM SCALE Operating and Service Manual Part No.: MAN947IFS_170629 Page 2 of 12 TABLE OF CONTENTS TABLE OF
More informationSAVE THESE INSTRUCTIONS
and Fixed Trapeze Assembly, Installation and Operating Instructions Model Nos. 7714P and 7740P SAVE THESE INSTRUCTIONS NOTE: Check ALL parts for shipping damage. In case of shipping damage, DO NOT use.
More informationSERVICE PEDESTAL FLOOR-MOUNTED SERVICE PEDESTAL. Installation Manual
SERVICE PEDESTAL Installation Manual FLOOR-MOUNTED SERVICE PEDESTAL Figure 1. DEFINITION OF STATEMENTS Statements in this manual preceded by the following words are of special significance: WARNING: Means
More informationV 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2
V 2.0 ASSEMBLY GUIDE Series 2 TABLE OF CONTENTS OVERVIEW General Specifications...1 Cautions and Disclaimers...1 Contents of Kit...1 Tools Required For Assembly...2 Time Required to Assemble...2 ASSEMBLING
More informationVARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model
VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model Operators Manual Issue 5 For correct operation of this autoclave it is essential that the chamber be filled with water up to the
More informationVARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model
DIXONS SURGICAL INSTRUMENTS LTD, 1 ROMAN COURT HURRICANE WAY, WICKFORD BUSINESS PARK WICKFORD, ESSEX, SS11 8YB, UK TEL: +44 (0)1268 764614 - FAX: +44 (0)1268 764615 EMAIL: info@dixons-uk.com - WEB: http://www.dixons-uk.com
More informationWelcome! How do I get a CE Certificate?
M Sterile U Network M Sterile U Web Meeting November 0, 0 Today s meeting times: 9:00 a.m., :00 a.m., and :00 p.m. Central Standard Time To hear audio, call 800-97-00 and enter access code 7 Phone lines
More informationA-Series Aluminum Gantry Crane
SPANCO PRODUCT SPECIFICATIONS 1 A-Series Aluminum Gantry Crane This guide can be used to prepare a bid specification for the incorporation of an A-Series Gantry Crane into a competitive bid project or
More informationMobile Drum Carrier. Owner s Manual
Mobile Drum Carrier Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
More informationGun Safe 6720F / 6740F. Operation & Installation Guide. FIRE 30minutes /1100ºF RATED THEFT. Manual # M
Operation & Installation Guide 6720F / 6740F Manual # M08-0292-004 www.firstalert.com Gun Safe THEFT FIRE 30minutes /1100ºF RATED Manual # M08-0292-004 Operation & Installation Guide Index Overview of
More informationEverything in its place. OWNER S MANUAL. TRINITY ECOSTORAGE 6-TIER NSF 48 x 18 x 72 WIRE SHELVING RACK w/wheels CHROME Model # TBFC-0907
Everything in its place. OWNER S MANUAL TRINITY ECOSTORAGE 6-TIER NSF 48 x 18 x 72 WIRE SHELVING RACK w/wheels CHROME Model # TBFC-0907 PARTS LIST Your TRINITY EcoStorage 6-Tier NSF Wire Shelving Rack
More informationOwner s Manual.
Owner s Manual Introduction Features / Benefits Records Specifications Warnings Controls / Diagrams Setting Up the Unit Operating the Unit Maintaining the Unit Consumer Information Warranty Information
More informationWealtec Corp. E-Centrifuge Microcentrifuge Operation Manual. Version 3.0 Item # *This instrument is intended for laboratory use only
Wealtec Corp. E-Centrifuge Microcentrifuge Operation Manual Version 3.0 Item # 03010-1 *This instrument is intended for laboratory use only http://www.wealtec.com E-mail: support@wealtec.com Packing List
More informationPedestrian Flood Door
Pedestrian Flood Door Operations & Maintenance Manual Models PD-520 PD-522FFR Table of Contents Product Information...2 Inspection & Maintenance...6 Inspection & Maintenance Log...7 Warranty Information...8
More informationWall-Mount & Back to Wall Toilets
Wall-Mount & Back to Wall Toilets Installation Guide FLOOR LW600 back to wall LW600 wall-mount FLOOR 05-04 Attention Before Installation If you are installing this product in a new construction or remodel,
More informationLotus. Reprocessing instructions for reusable instrumentation
Lotus Reprocessing instructions for reusable instrumentation Reprocessing instructions These instructions relate to the Lotus Transducers & Waveguides only. Following use remove the Single Use Handpiece
More informationDON T OPERATE WITH A FALSE SENSE OF SECURITY.
INVISIBLE HAZARDS. ARE YOU AT RISK? CONSIDER THE FACTS. DON T OPERATE WITH A FALSE SENSE OF SECURITY. Every Central Service department and Operating Room wants the right mix of rigid containers and wrapped
More informationSECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:
Page 1 of 7 SECTION 083925 MECHANICAL ROOM FLOOD DOORS AND FRAMES **Note to Specifier** This specification contains component and configuration options. Where indicated, choose the appropriate choice for
More informationIntroduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information
Gobi Owner s Manual Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information 3 4 5 6 7 8 9 10 Introduction
More informationLotus. Reprocessing instructions for reusable instrumentation. French/Swiss protocol
Lotus Reprocessing instructions for reusable instrumentation French/Swiss protocol Reprocessing instructions These instructions relate to the Lotus Transducers & Waveguides only. Following use remove the
More informationCompetency Guide: Care and Handling of Rigid Endoscopes
Competency Guide: Care and Handling of Rigid Endoscopes This document details the basic steps to correctly process and maintain a rigid endoscope. This document can be used to perform a competency review
More informationBESTMOVE STANDING TRANSFER AID
BESTMOVE STANDING TRANSFER AID MODELS BestMove 400 BestMove 450 PRODUCT FEATURES *BestMove 450 shown Ensure the product has been assembled according to the instructions in this manual. OPERATING ASSEMBLY
More informationSECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:
Page 1 of 8 SECTION 083921 PEDESTRIAN FLOOD DOORS AND FRAMES **Note to Specifier** This specification contains component and configuration options. Where indicated, choose the appropriate choice for your
More informationMiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2
MiT MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE OF MPL Digital Pedestal Manual Version 0.2 MOVING image TECHNOLOGIES, LLC. 17760 Newhope St. Fountain Valley, CA
More informationFLAD SERIES FOLDING LADDERS WITH WHEELS
VESTIL MANUFACTURING CORP. 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-1339 www.vestilmfg.com e-mail: sales@vestil.com
More informationSECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:
Page 1 of 8 SECTION 083919 WATERTIGHT DOORS **Note to Specifier** This specification contains component and configuration options. Where indicated, choose the appropriate choice for your specific project
More informationREF DOC # STANDARD IMAGING, INC Murphy Drive Middleton, WI TEL TEL FAX
WWW..COM REF 90086 STANDARD IMAGING, INC. 7601 Murphy Drive Middleton, WI 53562-2532 TEL 800.261.4446 TEL 608.831.0025 FAX 608.831.2202 Jul / 2006 2006 Standard Imaging, Inc. DOC #80173-04 General Precautions
More informationSECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:
Page 1 of 7 SECTION 083925 MECHANICAL ROOM FLOOD DOORS AND FRAMES **Note to Specifier** This specification contains component and configuration options. Where indicated, choose the appropriate choice for
More informationBESTMOVE STANDING TRANSFER AID
BESTMOVE STANDING TRANSFER AID L.L.C. MODELS BestMove 400 BestMove 450 PRODUCT FEATURES *BestMove 450 shown Ensure the product has been assembled according to the instructions in this manual. OPERATING
More informationEvolutionary Efficiency. Revolutionary Capacity.
Central Sterile Services Evolutionary Efficiency. Revolutionary Capacity. The AMSCO Evolution Floorloader Steam Sterilizer One Integrated Approach to Healthcare The Amsco Evolution Floorloader Steam Sterilizer
More informationEZ CONNECT RACK SHELVING. 72" (1.83 m) HIGH ÉTAGÈRE EZ CONNECT DE 72 PO (1,83 M) DE HAUT ESTANTE EZ CONNECT DE 72 (1,83 M) DE ALTURA
MODELS: GARK485X*/YGRK485X* GARK485T*/YGRK485T* GARK365T*/YGRK365T* EZ CONNECT RACK SHELVING 72" (1.83 m) HIGH Assembly Instructions ÉTAGÈRE EZ CONNECT DE 72 PO (1,83 M) DE HAUT Instructions d assemblage
More informationCYL-LP Series Cylinder Storage Cabinets Assembly and Maintenance Manual
VESTIL MANUFACTURING CORP. 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-1339 www.vestilmfg.com e-mail: sales@vestil.com
More informationDRUM-GRAB INSTRUCTION MANUAL
VESTIL MANUFACTURING CORP. 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-1339 www.vestilmfg.com e-mail: sales@vestil.com
More informationST 19 T Aluminium Thermostatically Controlled Electric Model
ST 19 T Aluminium Thermostatically Controlled Electric Model Operators Manual Issue 5 For correct operation of this autoclave it is essential that the chamber be filled with water up to the height of the
More informationand Shield with Vertical Needle Holder REF 90072
WWW..COM and Shield with Vertical Needle Holder REF 90072 STANDARD IMAGING, INC. 7601 Murphy Drive Middleton, WI 53562-2532 TEL 800.261.4446 TEL 608.831.0025 FAX 608.831.2202 Nov / 2006 2006 Standard Imaging,
More informationDRYWALL DOLLY 900 LB. CAPACITY
DRYWALL DOLLY 900 LB. CAPACITY 94883 ASSEMBLY & OPERATING INSTRUCTIONS Due to continuing improvement, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo,
More informationPEDESTRIAN FLOOD DOOR
PEDESTRIAN FLOOD DOOR Installation Instructions/Operation and Maintenance Manual Models: PD-520 PD-520FM PD-522 PD-522FM PD-525 PD-525FM Contact Information Table of Contents: Safety Precautions... 2 Product
More informationToilet Seat Installation Guide
Toilet Seat Installation Guide LSeat-001 duroplast LSeat-004 duroplast LSeat-002 plastic LSeat-005 duroplast LSeat-003 duroplast LSeat-006 plastic Attention Before Installation If you are installing this
More information450 and 550 Series Pressure/Vacuum Relief Valve (ATEX Approved)
Instruction Manual 450 and 550 Series March 2015 450 and 550 Series Pressure/Vacuum Relief Valve (ATEX Approved) Table of Contents Introduction...1 Specifications...2 Principle of Operation...4 Installation...4
More informationPOOL STEP INSTRUCTIONS (NE1087WH)
POOL STEP INSTRUCTIONS (NE1087WH) 6492 The sequence of the instructions may vary at points depending on the type of step system that you have purchased. If there are different instructions for your system,
More informationAMC-25CF/USAF Mobile Dental System
AMC-25CF/USAF Mobile Dental System PACKING GUIDE TABLE OF CONTENTS Introduction................................................................1 System Equipment and Features...............................................1
More informationGROUND MOUNT INSTALLATION MANUAL
GROUND MOUNT INSTALLATION MANUAL Contents DISCLAIMER 1 CHECKLIST 2 1. ERECT BASe 3 2. CONNECT PIPES 3 3. PLACE RAILS 4 4. SECURE LUGS 4 5. CLAMP MODULES 5 DIAGONAL BRACES (OPTIONAL) 6 UNDER CLAMPS (OPTIONAL)
More informationSelf-Rimming Installations - European Collection
Self-ming Installations - European Collection Vincennes 1 / HG-480 Vincennes 2 / HG-490 Westbury 1 / HG-420 Westbury 2 / HG-430 Vitoria / HG-880 Chimay / OV-410 Vincennes 1 / HG-480 Vincennes 2 / HG-490
More informationIT HAS BEEN A GOOD MORNING IN CENTRAL SERVICE (CS), AND THEN
Lesson No. CRCST 155 (Technical Continuing Education - TCE) Sponsored by: by Susan Klacik, BS, CRCST, ACE, CIS, FCS, and Linda Breadmont, CRCST, ACE Preventing Wet Packs LEARNING OBJECTIVES 1. Learn how
More informationBravo Platform Unpacking Guide
This guide describes how to unpack the Bravo device from the shipping carton. Depending on the order, the shipment can include additional packages for the Bravo utilities, pipetting head, computer, and
More informationPS-4045 Adjustable-Height Pallet Stand Use and Maintenance Manual
Vestil Manufacturing Co. 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-339 http://www.vestilmfg.com/ e-mail: sales@vestil.com
More informationMira Beat Fixed Showerhead and Arm
Mira Beat Fixed Showerhead and Arm These instructions must be left with the user Installation Guide and User Guide 1 2 INTRODUCTION Thank you for purchasing a quality product. To enjoy the full potential
More informationINSTALLATION MANUAL RECTANGULAR COLUMN
INSTALLATION MANUAL RECTANGULAR COLUMN Model # 5502 OVERVIEW The Rectangular Column is a UL-listed, multi-sided, vertical hospital modular service assembly. This system uses vertical and/or horizontal
More informationST XX28 Stainless Steel Thermostatically Controlled Electric Model
DIXONS SURGICAL INSTRUMENTS LTD, 1 ROMAN COURT HURRICANE WAY, WICKFORD BUSINESS PARK WICKFORD, ESSEX, SS11 8YB, UK TEL: +44 (0)1268 764614 - FAX: +44 (0)1268 764615 EMAIL: info@dixons-uk.com - WEB: http://www.dixons-uk.com
More information6 Handling, collection, and transport of contaminated items General rationale Separation of waste and reusable items at point of
Contents Glossary of equivalent standards... ix Committee representation... xi Acknowledgments...xiii Foreword... xiv Introduction: Need for the recommended practice...1 1 Scope...5 1.1 General...5 1.2
More informationDistribution Box INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS UGC
www.conairgroup.com INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS UGC070-1217 Distribution Box Corporate Office: 724.584.5500 l Instant Access 24/7 (Parts and Service): 800.458.1960 l Parts and
More informationOwner s Operator and Maintenance Manual Invacare Ramps
Owner s Operator and Maintenance Manual Invacare Ramps Important information is contained in this booklet. Please read it carefully before using your Invacare Ramp. Consult your doctor, therapist or other
More informationMolokai ShowerSpa Model #1006
Molokai ShowerSpa Model #1006 Please Read The Following Instructions COMPLETELY Before Beginning! Our goal is to ensure your installation goes smoothly and safely. Please read these instructions carefully
More informationSite Preparation... 2
TRUFIREWALLS INSTALLATION MANUAL This Installation Manual is intended to assist in the preparation and installation of TruFireWalls products manufactured by Oldcastle Enclosure Solutions. The TruFireWalls
More informationASSEMBLY & USER INSTRUCTIONS - UBETRACK MOBILE STORAGE SYSTEM
/US ASSEMBLY & USER INSTRUCTIONS - UBETRACK MOBILE STORAGE SYSTEM version 1.0 3 TABLE OF CONTTS Definitions... 5 General safety regulations... 5 Introduction... 7 Product... 8 Optionally available... 11
More informationFORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual
FORM HEADWALL (floating) Installation Manual FORM HEADWALL (floating) OVERVIEW The Form is a UL-listed configurable headwall system. This system includes multiple horizontal equipment channels integrated
More informationUsers Manual. Model 65 and Model 65-Pin. Scoop Stretcher. December 1999 DOM. Pub. No
Users Manual Model 65 and Model 65-Pin Scoop Stretcher December 1999 DOM Pub. No. 234-0099-10 Users Manual Models 65 and 65-Pin Scoop Stretcher Disclaimer This manual contains general instructions for
More information4-PIECE SHOWER & TUB/SHOWER w/ E-Z Pin INSTALLATION
4-PIECE SHOWER & TUB/SHOWER w/ E-Z Pin INSTALLATION Suggested Tools Please consult all local and state building codes and read the entire installation instructions prior to beginning the installation of
More informationMAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE
ELECTRICAL SPECIFICATION 1453 DIVISION OF ENGINEERING DEPARTMENT OF TRANSPORTATION CITY OF CHICAGO REVISED MARCH 14, 2013 MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE SUBJECT 1. This specification covers
More informationTENSOR-18. Assembly & Instruction Manual TENSOR-18 MODELS: MR1824 MR1824D. For Screen Printing, Industrial and Educational Applications
TENSOR-8 For Screen Printing, Industrial and Educational Applications Tensor-8 MR824 Double Tensor-8 Assembly & Instruction Manual TENSOR-8 MODELS: MR824 saturnrack@awt-gpi.com www.saturnrack.com Assembly
More informationKEEP FOR FUTURE REFERENCE MRT FORKLIFT ADAPTER READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT
KEEP FOR FUTURE REFERENCE P.O. Box 368 908 West Main Laurel, MT USA 59044 phone 800-548-7341 phone 406-628-8231 fax 406-628-8354 INSTRUCTIONS International Version STOCK NUMBER: 95722 MRT FORKLIFT ADAPTER
More informationRack Power Distribution Unit AP7562, AP7563, AP7564 General Information
Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information Description This booklet provides information on installing and operating the Rack Power Distribution Units (PDUs) AP7562, AP7563,
More informationPRU-D INSTALLATION MANUAL MONO-LEG SYSTEM. PRU-D / Portrait - Revision B July 31 st, 2017 Polar Racking Inc.
PRU-D INSTLLTION MNUL MONO-LEG SYSTEM Table of Contents Table of Contents... 2 1. Safety... 3 Basic Safety Considerations... 3 Warnings and Symbols... 3 Responsibilities of the Installer... 3 Responsibilities
More information