Multi-door Networking Controller

Size: px
Start display at page:

Download "Multi-door Networking Controller"

Transcription

1 AR-76EV AR-76Ei (RS-485) (0 Base-T) Multi-door Networking Controller User s Guide Version: 7. May 6, 004

2 Table of Contents. Introduction Installation Software Setting Server software setting of external weigand reader Door number setting of 70E Parameter DI Input V.S. Relay Output Connection Setting of 70E Parameter Weigand reader LED and Buzzer indicators AR-76E-IO Software Setting Set relay time AR-76E-IO hardware installation Push Button & Lock installation AR-77i Configuration Reset to Factory Default of the AR-77i DIP Switch Settings AR-77i s contains three LED indicators, as described in the following table How to set IP address on the AR-76Ei Get IP address by using Net77i software Get IP address by DHCP Server Get IP address by AR-80CM ( Port) connects to PC Installation diagram AR-76Ei and AR-7H networking installation AR-76EV and AR-7H networking installation Points for attation

3 3. Software Setting Server software setting of external weigand reader How to enter? Step: Click the 70 Server Icon twice to access the Server on the down right corner of the windows. Step: Click Tool Bar Icon (70E parameter) for the windows. Step3: Enter networking controller node ID, then click Read. Step4: Click the page of Door Number. Power Must higher than 3.8VDC Ethernet CN Power Battery Node: 009 To Node: 06 Node: 00 To Node: 008 To PC DCV CN4 AR-7H4 K K AR-80CM AR-7H4 DC5V Next Controller JP5 3-3 On:Clear Reset to default value (Must Power OFF) JP5 Vin CN Vin BV+ BV- CH CN3 CH HOST K CN4 K DI.4 DI.3 DI. JP4 D JP3 DI. D V D0 CN5 D9 3 JP K AR-77i - On:RUN Normal mode JP K JP5 Battery PORT AR-76Ei Red / Red V Black / Black GND Green / Green D0 Blue / Blue D Brown / Brown LED Purple / Gray BZ Red / Red V Black / Black GND Green / Green D0 or AR-7U PORT Blue / Blue D Brown / Brown LED Pink / Gray BZ AR-7K Busy Reset Node: Channel RX Channel TX Channel RX Channel TX Host RX Host TX Node ~ ~ Door number setting of 70E Parameter. Reader -8 is the door number of the CH RS-485 readers. (The CH can connect to on-line reader ID node -8).. Reader 9-6 is the door number of the CH RS-485 readers. (The CH can connect to on-line reader ID node 9-6). 3. ID Node of WG reader port is fixed to no.7 on the 76EV/Ei PCB. If enable anti-pass-back, ID Node 7 is fixed to be in door. 4. ID Node of WG reader port is fixed to no.8 on the 76EV/Ei PCB. If enable anti-pass-back, ID Node 8 is fixed to be out door. Note: The above Door number can be both changeable. Step5: Click the page of DI Input V.S. Relay Output Connection.

4 CN4 K K CN4 K K K K DI.4 DI.3 DI. JP4 D DI. D V D0 D9 CN5 3.3 DI Input V.S. Relay Output Connection setting of 70E Parameter. The DI. is exit button input of reader port and the K is open door relay. () Choose DI under the menu item. () Click K.. The DI.3 is exit button input of reader port and the K is open door relay. () Choose DI 3 under the menu item. () Click K. Note: Active second can be set only when the window is DI. 3.4 Weigand reader LED and Buzzer indicators. LED light green and one beep sound mean acknowledge, LED light green twice and two beep sounds mean not acknowledge.. In anti-pass-back access mode, LED light green five times and five beep sounds mean violates access function. 3. When access modes have entering user code, after flash card, LED light green four times and four beep sounds mean that reader wait for being entered the 4-digit user code. 3

5 4. AR-76E-IO Software Setting (Optional) 4. Set relay time Step: Click the page of Reader Relay V.S. 70E Relays Step: Enter relay time in the blank column. Range from 0 to 60,000. (Default 7 sec.) Step3: Press [ Write ]. 4. AR-76E-IO hardware installation Step: Take away each screw on the top left and on the down left of AR-76EV \ 76Ei PCB board. Step: Screw copper column to fix AR-76E-IO PCB board. Step3: Then, screw tightly copper column by using screw before take away. Step4: Connect plug DB of AR-76E-IO to socket DB of AR-76EV \ 76Ei PCB board. Connect plug DB of AR-76E-IO to socket DB of AR-76EV \ 76Ei PCB board. 4

6 4.3 Push Button & Lock installation CN C O M K K K 3 K 4 CN C O M K 5 K 6 K 7 K K NO NC NO NC NO NC NO NC I O - E X P E N D R E L A Y K R E L A Y K 3 K5 R E L A Y R E L A Y K 7 K7 K NO NC NO NC R E L A Y K R E L A Y K 4 NO K6 R E L A Y K 5 K 6 NC NO NC R E L A Y K 8 K8 CN 3V+ Node Node Node 0 Node 9 Node 4 Node 3 Node Node Push Button Door Exit GND CN 4 D B D B ECL-ACC00 CN -GND Lock (-GND) K K Power Supply +VDC A +VDC Lock (+VDC) Magnetic Lock CN K5 Power Supply +VDC A +VDC -GND Lock (-GND) Lock (+VDC) Magnetic Lock K6 K7 K8 5

7 5. AR-77i Configuration 5. Reset to Factory Default of the AR-77i Press RESET button more than 5 seconds, then AR-77i will restore to Factory Default value. IP Address : Gateway IP : Subnet Mask : Serail Port : 9600,N,8, TCP Port : 6 Password : none 5. DIP Switch Settings Switch Switch Description DHCP Function AR-77i support Auto Configuration of the IP and gateway addresses and subnet mask function, but must make sure the DHCP Server is active. Serial Setup Mode 5.3 AR-77i s contains three LED indicators, as described in the following table ACT BUSY LINK AR-77i LED Name LED Color LED Function Link Yellow Media is connected. Off Media is not connected. ACT Green 0 Mbps Ethernet connection. Off Ethernet cable is disconnected, or has a short. BUSY Red Configuration Setup. Off No. 6

8 5.4 How to set IP address on the AR-76Ei 5.4. Get IP address by using Net77i software Usually, the network of some company don t built-in the DHCP Server. Therefore, we can use the following method to get default IP address and modify it. The steps as follows: Step : Press RESET button more than 5 seconds, The BUSY LED will flash 5 times, then AR-77i will restore to Factory Default value. Step : Open explorer, click My Network Places and press right key to open Properties. Step 3: Click Local Area Connection and press right key to open Properties. Then double click Internet Protocol (TCP/IP) to open Properties. 7

9 Step 4: Click Use the following IP address and enter IP address , Subnet mask Step 5: Click ok to exit. Step 6: Install Net77i.exe into your PC and run Net77i.exe (Start Programs soyal software Net77i ) 8

10 Step 7: Click Get to get default Local IP Address, Gateway, Netmask and TCP Port. Step 8: Change new address and parameters then click write. Step 9: switch DIP SW- and SW- to OFF position. Remark: () How to know PC s IP Address? (Win98) Start execute enter winipcfg. () How to know PC s IP Address? (Win000) Start Programs Accessories Command Prompt C:\> ipconfig (3) Please see detailed parameter in next page: 9

11 Setting Value Notes Necessity Local IP Address Defines own IP Address of the Required AR-77CM Local Gateway IP Defines the IP Address of the default Required Address gateway Local Subnet Mask Defines the IP Address range for the local network segment Required TCP Port 6 The TCP port that other devices must Required use to contact this device. To avoid conflicts with standard TCP ports. MAC Address 00.E0.4C The MAC (Media Access Control) - address is a unique identifier set at the factory. Force Transmit time 5 Forces AR-77CM device s TCP/IP protocol software to try to pack serial Optional data received during the specified time into the same data frame. Force Transmit Bytes 3 Defines the amount of data in the serial, Ethernet buffer at which the break condition will be generated and the contents of buffer will be sent out via the Ethernet port. Optional Lock Remote IP - Allows contact with only the specified Optional Address remote IP address. Lock Serial Port - To avoid the hacker use this IP to Optional (Free Run or Freeze Over) intercept data when Remote IP Address doesn t receive data. Setup Password none Console password Optional Serial Port Speed 9600 Changes current baud rate of the Required AR-77CM s serial port (from 400bps to 57600bps). TCP Auto Disconnect Time (Second) Serial Port Hardware Handshaking (RTS/CTS) 60 This device automatically closes TCP Optional connection if there is no TCP activity for the given time. - An exchange of signal over specific Optional wires which each device indicates its readiness to send or receive data. DHCP - Selecting the enable option allows Optional DHCP to automatically assign the AR-77CM s IP address. 0

12 5.5. Get IP address by DHCP Server: AR-77i support Auto Configuration of the IP and gateway addresses and subnet mask function, but must make sure the DHCP Server is active. The steps as follows: Step : Power off. Step : PCB diagram as follows by using DHCP Function. Switch DIP SW- to position. Switch DIP SW- to OFF position. Switch Jumper J3, J4 and J5 to Net position. No IC Chip in the U3 position. Step 3: Power on. In begging state the ACT LED will flashing, after IP has got ACT LED will off and auto save the new IP address to EEPROM. Step 4: Power off. Step 5: Change communication IC Chip from the U position to the U3 position. Step 6: Then, Switch DIP SW- to OFF position and Switch DIP SW- to position. ( return to Serial Setup Mode) Step 7: Connect AR-80CM to the HOST of the PCB. Step 8: Power on. Step 9:To modify parameter on the AR-77i through the Hyper-Terminal function of the Window. (Start Programs Accessories Communication Hyper Terminal)

13 Step 0: Click Hyper-Terminal. Shown as follows: Step : key-in any temporary name. It is not important matter. Step : Choose which port that Step 3: Set Port Settings to 9600, 8, None,, AR-80CM connect and click OK to exit. None and click OK to save.

14 Step 4: AR-77i already gets IP address now shown as follows: Note that save it after set all parameters. Step 5: Power off. Then switch DIP SW- to OFF position, take away communication IC Chip on the U3 position of the PCB and AR-80CM. 3

15 5.5.3 Get IP address by AR-80CM ( Port) connects to PC At first, PCB diagram as follows and Connect AR-80CM to the HOST of the PCB: Switch DIP SW- to OFF position. Switch DIP SW- to position. (Serial Setup Mode) Switch Jumper J3, J4 and J5 to RS-485 position. Make sure that have communication IC Chip in the U3 position. 4

16 Step : To modify parameter on the AR-77i through the Hyper-Terminal function of the Window. (Start Programs Accessories Communication Hyper Terminal) Step : Click Hyper-Terminal. Shown as follows: Step 3: key-in any temporary name. It is not important matter. Step 4: Choose which port that Step 5: Set Port Settings to 9600, 8, None,, AR-80CM connect and click OK to exit. None and click OK to save. 5

17 Step 6: AR-77i already gets IP address now shown as follows: Step 7: Please refer above item and enter item on the so that set all parameters. Step 8: Note that enter item 6 on the to save parameter after finishing to set parameter. Step 9: Then switch DIP SW- and SW- to OFF position. 6

18 6. Installation diagram 6. AR-76Ei and AR-7H networking installation 3 Node ~ ~ DCV AR-76Ei Power Reset Channel RX Channel TX Channel RX Channel TX Host RX Host TX Node: Blue / Blue D Brown / Brown LED Purple / Gray BZ Red / Red V Black / Black GND Green / Green D0 AR-7U or AR-7K Red / Red V Black / Black GND Green / Green D0 Blue / Blue D Brown / Brown LED Pink / Gray BZ Node: 009 To Node: 06 Node: 00 To Node: 008 AR-80CM Next Controller To PC Battery DC5V Vin Battery Vin PORT BV+ BV- CN3 CH AR-7H4 CH AR-7H4 JP JP HOST K K K K CN Ethernet CN JP5 PORT Busy 73 Power Must higher than 3.8VDC AR-77i DI.4 JP3 D JP4 D DI.3 DI. DI. D0 D9 V CN5 CN4 JP5-3 On:Clear Reset to default value (Must Power OFF) CN4 3 K K JP5 - On:RUN Normal mode 3 7

19 6. AR-76EV and AR-7H networking installation Node: 009 To Node: 06 Node: 00 To Node: 008 Battery Power Must higher than 3.8VDC DC5V Vin Battery Vin BV+ BV- CN3 CH AR-7H4 CH AR-7H4 JP JP HOST K K K K CN4 AR-80CM Next Controller To PC Node ~ ~ Node: AR-76EV Power D JP4 Reset DI.4 Channel RX Channel TX Channel RX Channel TX Host RX Host TX JP3 D DI.3 DI. DI. D0 PORT D9 V CN5 DCV CN4 JP5 Pink / Gray BZ Brown / Brown LED CN Ethernet CN JP5 77i 73 Busy PORT Blue / Blue D Green / Green D0 Black / Black GND Red / Red V Purple / Gray BZ Brown / Brown LED Blue / Blue D Green / Green D0 Black / Black GND Red / Red V -3 On:Clear Reset to default value (Must Power OFF) 3 K K JP5 - On:RUN Normal mode 3 AR-7K or AR-7U Note that the connecting distance between AR-80CM and the PC cannot be more than meter. 8

20 6.3 Points for attention. Please use the following installation method, it is correct. 80CM OR Controller Controller OR Reader. Don t use the following installation method, it will cause communication error. 80CM OR Controller Controller OR Reader 3. We suggest using the following cable in RS-485 communication Please screw snake net on the controller. 9