Verification Result :.

Size: px
Start display at page:

Download "Verification Result :."

Transcription

1 Verification Report. No. Date: 08 May Page WUHU DELUX MOBILE INTERNET DEVICE CO.,LTD. WUHU MACHINERY INDUSTRIAL PARK, ANHUI, CHINA.. Name :. Designer Keyboard. SGS Job No. : RP SZ. Tested Basic Model No. (P.O. No.) :. Client Ref. Info. :. T11. Date Received :.. Verification Period : Mar Verification Requested :. With reference to RoHS Directive (EU) 2015/863 amending 2011/65/EU.. Verification Method :. Please refer to next page(s).. Verification Result :. Please refer to next page(s).. Verification :. Based on the verification results the submitted samples, the results Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs) do not exceed the limits as set by RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU.. The test results are related only to the tested items. The report shall not be reproduced except in full without the written approval the testing laboratory.. According to the declaration from applicant, the materials in Model Designer are the same as those in Model T11, and the results Model T11 for support the results in Model Designer.. Note :. Signed for and on behalf SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch. Bellen Fu. Approved Signatory...

2 Verification Report. No. Date: 08 May Page Verification Method :. 1.With reference to IEC :2013, review was performed for the samples disjointed from the submitted articles. 2. With reference to IEC :2013, tests were performed for the samples indicated by the photos in this report (1) With reference to IEC :2013, screening by spectroscopy (2) Wet chemical test method a.with reference to IEC :2013, determination Cadmium by ICP-OES b.with reference to IEC :2013, determination Lead by ICP-OES c.with reference to IEC :2013+A1:2017, determination Mercury by ICP-OES d.with reference to IEC :2015, IEC :2017 & ISO :2017, determination Hexavalent chromium by Colorimetric method using UV-Vis. e.with reference to IEC :2015, determination PBBs and PBDEs by GC-MS.

3 Verification Report. No. Date: 08 May Page In accordance with the result material risk assessment, the following disjointed parts in the submitted sample have been verified.. Result Wet 1. Gray woven band. -. Pb. BL Comply Gray fabric. -. Pb. BL Comply Silvery metal shell. -. Pb. BL Comply Silvery metal shell. -. Pb. BL Comply...

4 Verification Report. No. Date: 08 May Page Result Wet 5. White woven band. -. Pb. BL Comply Silvery & copper metal pin. -. Pb. BL Comply White plastic part. -. Pb. BL Comply White plastic part. -. Pb. BL Comply...

5 Verification Report. No. Date: 08 May Page White plastic (cable jacket). Result Wet -. Pb. BL Comply White plastic (wire insulation). 11. Green plastic (wire insulation). 12. Red plastic (wire insulation). -. Pb. BL Comply Pb. BL Comply Pb. BL Comply...

6 Verification Report. No. Date: 08 May Page Black plastic (wire insulation). Result Wet -. Pb. BL Comply Silvery metal core wire. -. Pb. BL Comply... Cr(VI). IN.. ND.. Comply Silvery metal shell. -. Pb. BL Comply... Cr(VI). IN.. ND.. Comply Silvery metal shell. -. Pb. BL Comply...

7 Verification Report. No. Date: 08 May Page Result Wet 17. White plastic part. -. Pb. BL Comply Black plastic part. -. Pb. BL Comply Silvery metal part. -. Pb. BL Comply... Cr(VI). IN.. ND.. Comply Silvery metal pin. -. Pb. OL Comply...

8 Verification Report. No. Date: 08 May Page Result Wet 21. Green "PCB". -. Pb. BL Comply... PBBs. IN.. ND.. Comply... PBDEs. IN.. ND.. Comply C. Silvery metal wire (solder). -. Pb. BL Comply Feb Silvery metal shell. -. Pb. BL Comply White plastic key w/ black surface. -. Pb. BL Comply...

9 Verification Report. No. Date: 08 May Page Result Wet 25. White rubber part. -. Pb. BL Comply Silvery metal shell. -. Pb. BL Comply Silvery metal screw. -. Pb. BL Comply Beige dry glue. -. Pb. BL Comply...

10 Verification Report. No. Date: 08 May Page Beige plastic shell w/ white surface. Result Wet -. Pb. BL Comply Silvery metal screw. -. Pb. BL Comply White plastic part. -. Pb. BL Comply Black plastic frame. -. Pb. BL Comply...

11 Verification Report. No. Date: 08 May Page Result Wet 33. Coppery metal part. -. Pb. BL Comply Silvery metal part. -. Pb. BL Comply Silvery metal spring clip. -. Pb. BL Comply... Cr(VI). IN.. ND.. Comply Silvery metal spring. -. Pb. BL Comply... Cr(VI). IN.. ND.. Comply...

12 Verification Report. No. Date: 08 May Page Result Wet 37. White plastic part. -. Pb. BL Comply White plastic part. -. Pb. BL Comply Silvery metal part. -. Pb. BL Comply... Cr(VI). IN.. ND.. Comply Black plastic shell. -. Pb. BL Comply...

13 Verification Report. No. Date: 08 May Page Result Wet 41. Black plastic frame. -. Pb. BL Comply Silvery metal part. -. Pb. BL Comply Silvery metal part. -. Pb. BL Comply... Cr(VI). IN.. ND.. Comply Silvery metal part. -. Pb. BL Comply...

14 Verification Report. No. Date: 08 May Page Result Wet 45. Silvery metal part. -. Pb. BL Comply Silvery metal part. -. Pb. BL Comply Silvery metal shell. -. Pb. BL Comply Silvery metal spring. -. Pb. BL Comply...

15 Verification Report. No. Date: 08 May Page Result Wet 49. Black plastic terminal. -. Pb. BL Comply Silvery plastic quadrate plate w/ black surface. -. Pb. BL Comply Gray plastic frame. -. Pb. BL Comply C. Silvery metal pin. -. Pb. BL Comply Feb 2018

16 Verification Report. No. Date: 08 May Page Result Wet 53. Black "IC" body. -. Pb. BL Comply Black "IC" body. -. Pb. BL Comply Black "IC" body. -. Pb. BL Comply Black "IC" body. -. Pb. BL Comply...

17 Verification Report. No. Date: 08 May Page Result Wet 57. Silvery metal plate. -. Pb. BL Comply... Cr(VI). IN.. ND.. Comply Black plastic part. -. Pb. BL Comply Silvery & coppery metal pin. -. Pb. BL Comply Silvery metal spring. -. Pb. BL Comply...

18 Verification Report. No. Date: 08 May Page Result Wet 61. Black plastic part. -. Pb. BL Comply... PBBs. IN.. ND.. Comply... PBDEs. IN.. ND.. Comply Silvery metal frame. -. Pb. BL Comply... Cr(VI). IN.. ND.. Comply Black plastic part. -. Pb. BL Comply Blue "PCB". -. Pb. BL Comply...

19 Verification Report. No. Date: 08 May Page Result Wet 65. Blue "PCB". -. Pb. BL Comply Silvery metal solder. -. Pb. BL Comply...

20 Verification Report. No. Date: 08 May Page Remark : (1) (a) There are the results on total Br while test items on restricted substances are PBBs and PBDEs. There is the result on total Cr while test item on restricted substances is Cr(VI). (b) are obtained by for primary screening, and further chemical testing by ICP-OES (for Cd, Pb, Hg), UV-Vis (for Cr(VI)) and GC-MS (for PBBs, PBDEs) is recommended to be performed, if the concentration exceeds the below warning value according to IEC :2013 (unit: mg/kg). Element Polymer Metal Cd BL (70-3σ)< X <(130+3σ) OL BL (70-3σ)< X <(130+3σ) OL Pb BL (700-3σ)< X<(1300+3σ) OL BL (700-3σ)< X <(1300+3σ) OL Composite Materials LOD < X <(150+3σ) OL BL (500-3σ)< X<(1500+3σ) OL Hg BL (700-3σ)< X <(1300+3σ) OL BL (700-3σ)< X <(1300+3σ) OL BL (500-3σ)< X <(1500+3σ) OL Br BL (300-3σ)< X -- BL (250-3σ)< X Cr BL (700-3σ)< X BL (700-3σ)< X BL (500-3σ)< X (c) BL = Below Limit, OL = Over Limit, IN = Inconclusive, LOD = Limit Detection, -- = Not regulated. (d) The XRF screening test for RoHS elements - The reading may be different to the actual content in the sample be non-uniformity composition. (2) (a) mg/kg = %, MDL = Method detection Limit, ND = Not Detected (<MDL), --- = Not conducted, - = Without BOM. (b) Unit and MDL in wet chemical test Test Item Pb Cd Hg Unit mg/kg mg/kg mg/kg MDL The MDL for single compound PBBs and PBDEs is 100 mg/kg, MDL Cr(VI) for polymer, composite and leather sample is 10 mg/kg, MDL Cr(VI) for metal sample is 0.10 μg/cm².

21 Verification Report. No. Date: 08 May Page (c) =Metal sample a. The sample is positive for CrVI if the CrVI concentration is greater than 0.13 μg/cm². The sample coating is considered to contain CrVI b. The sample is negative for CrVI if CrVI is ND (concentration less than 0.10 μg/cm²). The coating is considered a non-crvi based coating c. The result between 0.10 μg/cm² and 0.13 μg/cm² is considered to be inconclusive - unavoidable coating variations may influence the determination Information on storage conditions and production date the tested sample is unavailable and thus Cr(VI) results represent status the sample at the time testing. IEC series is equivalent to EN series < 25> (3) =According to the declaration from the client, Lead (Pb) in No.20 is exempted by EU RoHS directive 2011/65/EU based on ANNEX III 6(c) : Copper alloy containing up to 4 % lead by weight..

22 Verification Report. No. Date: 08 May Page photo:.

23 Verification Report. No. Date: 08 May Page

24 Verification Report. No. Date: 08 May Page

25 Verification Report. No. Date: 08 May Page

26 Verification Report. No. Date: 08 May Page

27 Verification Report. No. Date: 08 May Page

28 Verification Report. No. Date: 08 May Page

29 Verification Report. No. Date: 08 May Page

30 Verification Report. No. Date: 08 May SGS authenticate the photo on original report only. *** End Report ***. Page