CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC Test Report Number : CGZ C

Size: px
Start display at page:

Download "CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC Test Report Number : CGZ C"

Transcription

1 CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC TEST REPORT Test Report Number : CGZ C PHONE FAX

2 PAGE : 1 of 5 Table of contents 1 General Information Application Details Manufacturer & Buyer Description of the Test Item 2 2 Test Results General Information Sample Receiving Date Testing Period Test Requested Test Method Results FDA CPG and Total Chromium Content 4 3 Sample Reference Photo 5

3 PAGE : 2 of 5 1 General Information 1.1 Application Details Name Address Contact Telephone : Fax : Mobile telephone : gavin@hwe.com.hk 1.2 Manufacturer & Buyer Manufacturer name Address Contact Telephone : Fax : Mobile telephone : Buyer name 1.3 Description of the Test Item : Highwin Stainless Steel Products LTD. : Qian Feng Industrial Zone, Siqian, Xinhui District, Jiangmen, Guangdong, China : Mr. Cao : Highwin Stainless Steel Products LTD. : Qian Feng Industrial Zone, Siqian, Xinhui District, Jiangmen, Guangdong, China : Mr. Cao : gavin@hwe.com.hk : Global Market Group Sample name : Coffee press Model No. : P P Brand name : / Condition of sample(s) : EFFECTIVE 2 Test Results 2.1 General Information Sample Receiving Date Mar. 2, Testing Period Mar. 2, 2011 to Mar. 10, 2011

4 PAGE : 3 of Test Requested 1) Determine the leachable Lead and Cadmium contents from internal surface in accordance with the American Food and Drug Administration (FDA) Compliance Policy Guides (May 2005) and (May 2005). 2) As specified for client, for compliance with the General Recognized As Safe (GRAS) Specification. According to United State Food and Drug Administration (US FDA) regulations on stainless steel-total chromium content Test Method 1) With reference to AOAC 16th Ed. (2000) Section , Lead and Cadmium in Ceramic ware and Glass. 2) Titration method. 2.2 Results FDA CPG and Internal Surface (Small Hollowware) Pass Ave. Released Lead (mg/l) <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 Released Cadmium (mg/l) <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Volume of 4% Acetic acid used (ml) Depth (mm) Diameter (mm) Test Part Description : Glass pot Note : 1. µg/ml = microgram per millilitre 2. Results were analysed directly by Atomic Absorption Spectrometry.

5 PAGE : 4 of Total Chromium Content When tested as specified, the submitted metal sample complies with the General Recognized As Safe(GRAS) Specifications for US FDA regulation on stainless steel. Test Item(s) Result Minimum permissible Limit Total chromium content (Cr) 16.2% 16% Test Part Description : Stainless steel Written by: Inspected by: Approved by: ***End of Report***

6 PAGE : 5 of 5 3 Sample Reference Photo Test Sample