PRODUCT DATA SHEET Sikafloor -264

Size: px
Start display at page:

Download "PRODUCT DATA SHEET Sikafloor -264"

Transcription

1 PRODUCT DATA SHEET 2-PART EPOXY ROLLER AND SEAL COAT DESCRIPTION is two part, economic, coloured epoxy resins. "Total solid epoxy composition acc. to the test method of Deutsche Bauchemie" USES may only be used by experienced professionals. Roller coat for concrete and cement screeds with normal up to medium heavy wear e.g. storage and assembly halls, maintenance workshops, garages and loading ramps. Seal coat for broadcast systems, such as multi-storey and underground car parks, maintenance hangars and for wet process areas, e.g. beverage and food industry. CHARACTERISTICS / ADVANTAGES Good chemical resistance. Easy application. Economical. Liquid proof. Gloss finish. Slip resistant surface possible. APPROVALS / STANDARDS Chemical resistance test report from National Research Center. conforms to the requirements of LEED EQ Credit 4.2: Low-Emitting Materials: Paints & Coatings SCAQMD Method VOC Content < 100 g/l 1 / 5

2 PRODUCT INFORMATION Chemical Base Packaging Epoxy Ready for use pre-proportioned units at 15 kg (A+B). Appearance / Colour Resin - part A: coloured, liquid Hardener - part B transparent, liquid Light grey Shelf Life Storage Conditions Other colours on request. 12 months from date of production The product must be stored in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +5 C and +30 C. Density Part A ~ 1.64 kg/l Part B ~ 1.00 kg/l Mixed resin ~ 1.40 kg/l Solid content by weight ~100% Solid content by volume ~100% TECHNICAL INFORMATION All Density values at +23 C. (DIN EN ISO ) Shore D Hardness ~76 (7 days / +23 C) (DIN ) Abrasion Resistance 76 mg (CS 10/1000/1000) (7 days / +23 C) (DIN ) Compressive Strength ~ 60 N/mm 2 (28 days / 23 o C) (EN196-1) Tensile Strength in Flexure ~ 30 N/mm 2 (28 days / 23 o C) (EN 196-1) Tensile Adhesion Strength >1.5 N/mm² (failure in concrete) (ISO 4624) Chemical Resistance Resistant to many chemicals. Contact Sika technical service for specific information. Thermal Resistance Exposure* Dry heat Permanent +50 C Short-term max. 7 d +80 C Short-term max. 12 h +100 C Short-term moist/wet heat* up to +80 C where exposure is only occasional (steam cleaning etc.). *No simultaneous chemical and mechanical exposure 2 / 5

3 SYSTEM INFORMATION Systems Roller coating: Coating: 2 X Sikafloor -264 APPLICATION INFORMATION Mixing Ratio Texture roller coating: Coating: 1-2 X Sikafloor Extender T Broadcast system apporox. 4mm: Base coat: 1 X Sikafloor -263 SL + quartz sand ( mm) Broadcasting: quartz sand ( mm) broadcast to excess Seal coat: 1 X Sikafloor -264 Part A : part B = 79 : 21 (by weight) Consumption Coating System Product Consumption Primer Sikafloor kg./m 2 Levelling (optional) Sikafloor -161 levelling Refer to PDS of Sikafloor mortar -161 Roller coating 2 X Sikafloor kg./m 2 for each layer Textured roller coating 1 2 X Sikafloor kg./m2 per Extender T layer 10 pbw Sikafloor Textured roller coating with improved slip kg./m 2 + Extender T + 1 pbw quartz sand ( kg./m resistance Ambient Air Temperature Relative Air Humidity Dew Point Substrate Temperature Substrate Moisture Content Broadcast system (Film thickness ~ 4.0 mm) mm) 1 pbw Sikafloor -263 SL 2.00 kg./m 2 1 pbw quartz sand ( kg./m mm) + broadcasting quartz sand ~ 6.0 kg./m 2 mm +Seal coat Sikafloor ~ 0.7 kg./m These figures are theoretical and do not allow for any additional material due to surface porosity, surface profile, variations in level and wastage etc. +10 C min. / +30 C max. 80% r.h. max. Beware of condensation! The substrate and uncured floor must be at least 3 C above dew point to reduce the risk of condensation or blooming on the floor finish. Note: Low temperatures and high humidity conditions increase the probability of blooming. +10 C min. / +30 C max. < 4% pbw moisture content. Test method: Sika -Tramex meter, CM-measurement or Oven-dry-method. No rising moisture according to ASTM (Polyethylene-sheet). Pot Life Temperature Time +10 C ~ 50 minutes +20 C ~ 25 minutes +30 C ~ 15 minutes 3 / 5

4 Curing Time Before applying on allow: Substrate temperature Minimum Maximum +10 C 30 hours 3 days +20 C 24 hours 2 days +30 C 16 hours 1 days Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity. Applied Product Ready for Use Temperature Foot traffic Light traffic Full cure +10 C ~ 72 hours ~ 6 days ~ 10 days +20 C ~ 24 hours ~ 4 days ~ 7 days +30 C ~ 18 hours ~ 2 days ~ 5 days Note: Times are approximate and will be affected by changing ambient conditions. APPLICATION INSTRUCTIONS SUBSTRATE QUALITY / PRE-TREATMENT The concrete substrate must be sound and of sufficient compressive strength (minimum 25 N/mm 2 ) with a minimum pull off strength of a.5 N/mm 2. The substrate must be clean, dry and free from all contaminants such as dirt, oil, grease, coating and surface treatments, etc. If in doubt, apply a test area first. MIXING Mixing Part A : part B = 79 : 21 (by weight) Mixing Time Stir component (A) thoroughly with an electric stirrer prior to batching. Add component (B) in the correct mix ratio and mix for 2-3 minutes at a low speed until a homogeneous mix is achieved. APPLICATION Coating: Sikafloor -264 can be applied by short-piled roller In order to achieve an even and uniform coverage of the surface Seal Coat:Sealer coats can be applied by squeegee and then back-roller (crosswise) with a short-piled roller. CLEANING OF TOOLS Clean all tools and equipment immediately after use with Colma-Cleaner. Once hardened, the material can only be removed mechanically. Wash soiled hands and skin thoroughly with hot soapy water. MAINTENANCE To maintain the appearance of the floor after application, must have all spillages removed immediately and must be regularly cleaned using rotary brush, mechanical scrubbers, scrubber dryer, high pressure washer, wash and vacuum techniques etc. using suitable detergents and waxes LIMITATIONS Do not blind the primer. Do not apply on substrates with rising moisture. Freshly applied must be protected from damp, condensation and water for at least 24 hours. Avoid puddles on the surface with the primer. For roller / textured coating: Uneven substrates as well as inclusions of dirt cannot and should not be covered by thin sealer coats. Therefore both substrate and adjacent areas must always be preprated and cleaned thoroughly prior to application. BASIS OF PRODUCT DATA All technical data stated in this are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. LOCAL RESTRICTIONS Please note that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local Product Data Sheet for the exact description of the application fields. ECOLOGY, HEALTH AND SAFETY Ecology In a liquid state comp. (A+B) can contaminate water. Do not dispose of into water or soil but according to local regulations Transport Comp. (A): Non-hazardous. Comp. (B): Non-hazardous. Safety precautions This product can cause skin irritation to persons with sensitive skin. Always rub barrier cream into hands and exposed skin before starting work. Wear protective clothing (gloves and goggles). If is accidentally splashed into the eyes, nose, mouth or throat, flush immediately with plenty of clean, warm water and seek medical attention without delay. Toxicity Comp. (A): Class 4, under the relevant health and 4 / 5

5 safety codes. Comp. (B): Class 4. LEGAL NOTES The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika s current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. It may be necessary to adapt the above disclaimer to specific local laws and regulations. Any changes to this disclaimer may only be implemented with permission of Sika Corporate Legal in Baar. Sika Egypt 1st Industrial Zone (A) Section #10, Block El Obour City, Egypt TEL: FAX: Alexandria Office 4, Mihamed Masoud st Bab Sharki Alexandria Tel: /2/3 Mob: Fax: Cairo Sales office 222,El-Hegaz St, Heliopolis, Cairo Egypt Tel: /4 Mob: Fax: Borg El-Arab Factory 2nd industrial zone block 28 Borg El Arab City, Alexandria Egypt Tel: /1417 Mob: Fax: Sikafloor-264_en_EG_( )_3_1.pdf 5 / 5