1 TUFF-SEAL Toll Free Fax COMPLETE ASSEMBLY PART NUMBERS RSR SERIES ALUMINUM CORD RIPS RSR Series Straight Aluminum Cord rips Tuff Seal RSR Series Aluminum Cord rips are UL Listed and CSA Certified for use in both indoor and outdoor applications to prevent cable pullout, control arc of bend, and to provide a tight seal against environmental elements such as dirt, moisture and coolants. The breadth of the line encompasses conduit sizes from /4" to " with fittings offered in machined aluminum, nickel-plated aluminum, steel, stainless steel, nylon and Valox. Other features of the family of RSR Cord rips include: A unique design with a combination tightening surface that includes both a hex area and a knurled surface Available with or without stainless steel wire mesh Optional embedded Viton O-Ring ensures a watertight and corrosion-resistant seal Available in NPT, Pg/ISO or Metric threads Anti-friction washer that fits between the nut and bushing for easier compression. NOTES Accessories Locknuts and O-Rings: Pages 8 Special Configurations Special configurations and materials are available. Consult factory. All wire mesh is stainless steel. Dimension & certification information on pages -4 & -6 in Tuff-Seal Technical Reference. For dimensions match the Form Size to the chart on page 6 Conduit Form Cord Cord rip Size (NPT) Size Cable Range rip With Mesh /4" RSR RSR-0004 RSR-0004-E RSR-0005 RSR-0005-E.2.75 RSR-0006 RSR-0006-E RSR-0007* RSR-0007-E /8" /2" RSR RSR-004 RSR-004-E RSR-005 RSR-005-E.2.75 RSR-006 RSR-006-E RSR-007* RSR-007-E RSR RSR-004 RSR-004-E RSR-005 RSR-005-E.2.75 RSR-006 RSR-006-E RSR-007 RSR-007-E /2" RSR RSR-04 RSR-04-E RSR-05 RSR-05-E RSR-06 RSR-06-E RSR-07 RSR-07-E RSR-08 RSR-08-E RSR-09 RSR-09-E RSR-0 RSR-0-E /2" RSR-208 RSR-208-E RSR-209 RSR-209-E RSR-20 RSR-20-E RSR-2* RSR-2-E RSR-22* RSR-22-E RSR-2* RSR-2-E /4" RSR RSR-204 RSR-204-E RSR-205 RSR-205-E RSR-206 RSR-206-E RSR-207 RSR-207-E RSR-208 RSR-208-E RSR-209 RSR-209-E RSR-20 RSR-20-E /4" RSR-208 RSR-208-E RSR-209 RSR-209-E RSR-20 RSR-20-E RSR-2 RSR-2-E RSR-22 RSR-22-E RSR-2 RSR-2-E /4" RSR-209 RSR-209-E RSR-20 RSR-20-E RSR-2 RSR-2-E RSR-22 RSR-22-E RSR-2 RSR-2-E RSR-24* RSR-24-E RSR-25* RSR-25-E RSR-26* RSR-26-E *Cable may have to be stripped to pass through the bore of the body NOTICE Suitable for use in corrosive environments Nickel-plated aluminum: Cord grips available in nickel-plated aluminum. Add "N" to end of prefix. (ex: RSR-000 becomes RSRN-000)

2 Toll Free Fax RSR STRAIHT CORD RIP DIMENSIONS ALUMINUM AND NICKEL-PLATED ALUMINUM Size Size Body Bore Body Dia. Nut Dia. 4" " " " " " " " " " " " " " " " " Dimension A is the minimum Body Bore. Other dimensions are nominal. Dimension D is with the Nut snug but Bushing uncompressed. Dimension E is across the Body Hex. corners. NYLON AND VALOX 8" " " STEEL 8" " " " STAINLESS STEEL 8" " " "

3 Selection, Service & Quality Solutions TUFF-SEAL TUFF-SEAL TECHNICAL REFERENCE SECTION STATEMENT Remke Industries supports the European Union s efforts to remove harmful chemicals from electrical products. In compliance with Directive 2002/95/EC of the European Parliament and the Council of the European Union regarding the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS), Remke Industries certifies either:. The maximum concentration values of weight in homogenous materials for the substances referred to in Article 4() of directive 2002/95/EC that are contained in the products do not exceed the maximum concentration values of 0.% in respect of lead, mercury, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers, and 0.0% in respect of cadmium. OR 2. The product supplied is exempt from this directive. Remke Industries certifies that all products of our manufacture are fully compliant to the current RoHS Directive. ISO CERTIFICATION On July st, 200 Remke Industries received ISO 900 : 2000 certification which certifies that Remke is compliant with current ISO standards. Toll Free Fax OPERATIN TEMPERATURES Material Aluminum Nylon Steel Stainless Steel Neoprene (bushings) Silicone (bushings) Valox Dome-Cap Connectors: Non-Metallic Metallic FLAMMABILITY Temperature range -40 F to +00 F (-40 C to +49 C) -40 F to +225 F (-40 C to +07 C) -60 F to +000 F (-5 C to +57 C) -60 F to +000 F (-5 C to +57 C) -40 F to +250 F (-40 C to +2 C) -50 F to +450 F (-65 C to +22 C) -40 F to +250 F (-40 C to +2 C) -22 F to +76 F (-0 C to +80 C) -40 F to +22 F (-40 C to +00 C) Component Rating Mesh rip UL 94HB Fitting UL 94V-2 Note: Non-metallic cord connectors will not support combustion. APPROVALS, CERTIFICATION & COMPLIANCES Agency File Number Product or Component Underwriters E5599 RSR Series (Straight, 90, 45 ) Laboratories Inc. (UL) RSP Series (Straight, 90 ) RSM Cord rips RSRS Cord rips Canadian Standards RSR Series (Straight, 90, 45 ) Association (CSA) RSP Series (Straight, 90 ) RSRS Cord rips RSSS Series RSPV Series Teck Cable Connectors National Electrical Articles RSR Series (Straight, 90, 45 ) Code (NEC) Articles RSP Series (Straight, 90 ) RSM Cord rips RSRS Cord rips ROHS & WEE Articles 50-4(B) WH Series Watertight Conduit Hubs Articles 502-4(A) WH Series Watertight Conduit Hubs Articles 50-(A) WH Series Watertight Conduit Hubs All Tuff-Seal and Tuff-Link Products are Compliant HAZARDOUS LOCATIONS Definition Remke Products The Remke products listed are RSR Series (Straight, 90, 45 ) suitable for use in hazardous locations WH Series Watertight Conduit Hubs per Class I, Div. 2, Class II, Div & 2, RSP Series (Straight, 90 ) and Class III, Div. & 2 RSM Cord rips, RSRS Cord rips KNOCKOUT DIMENSIONS N.P.T. Knockout Hole Recommended Hub Size (Min to Max / Inches) /4".540 to.570 /8".67 to.70 /2".859 to.906 /4".094 to.4 ".59 to.406 /4".79 to.766 /2".969 to " 2.45 to /2" 2.95 to.000 ".578 to.625 4

4 Toll Free Fax RATINS/MATERIAL OF CONSTRUCTION IP 54 and IP 54 and IP 65 and IP 56 and IP 67 and IP 52 and Material NEMA NEMA R NEMA 4 NEMA 4X NEMA 6 NEMA 2 Aluminum X X X X X Nickel-Plated Aluminum X X X X X X Steel X X X X X Stainless Steel X X X X X X Nylon X X X X X Valox X X X X X X IP RATINS DEFINITION First Digit 50mm Protection From Solid Objects 0 Non-Protected Protected against solid objects over 50mm e.g hands, large tools Second Digit Protection From Moisture 0 Non-Protected Protection against vertically falling drops of water 2 Protected against solid objects over 2mm 2mm e.g hands, large tools 2 5 Protection against direct sprays of water up to a 5 angle Protection from entry by solid objects over 2.5mm 2.5mm e.g. wire or small tools 60 Protection against direct sprays of water up to a 60 angle 4 Protection from entry by solid objects over.0mm.0mm e.g. wires or tools 4 Protection against water sprayed from any direction. Limited ingress permitted. 5 Protection against deposits of dust e.g. against equipment damage due to deposits 5 Protection against low pressure water jets from any direction. Limited ingress permitted 6 Total protection against dust ingress e.g. Dust-Tight 6 Protection against high pressure water jets from any direction. Limited ingress permitted. IP CODE EXAMPLE IP54 = IP (IP LETTER CODE), 5 (st Digit), 4 (2nd Digit) 7 Protection against immersion between 5cm and M 8 Protection against complete and continuous immersion in water under pressure e.g Water-Tight 5

5 Toll Free Fax THREAD SPECIFICATIONS P THREAD SPECIFICATIONS Size Diameter (mm) Pitch (mm) Outside Diameter(mm) Pg Pg Pg Pg Pg Pg Pg Pg Pg Pg NPT THREAD SPECIFICATIONS Size Diameter (mm) Pitch (mm) NPT /4".7.4 NPT /8" 7..4 NPT /2" 2..8 NPT /4" NPT " NPT -/4" NPT -/2" NPT 2" METRIC THREAD SPECIFICATIONS Size Diameter (mm) Pitch (mm) Outside Diameter(mm) M2 x M6 x M20 x M25 x M2 x M40 x M50 x M6 x