CERTIFICATE OF ACCREDITATION

Size: px
Start display at page:

Download "CERTIFICATE OF ACCREDITATION"

Transcription

1 CERTIFICATE OF ACCREDITATION ANSI National Accreditation Board Coldwater Road, Fort Wayne, IN USA This is to certify that ATRONA Test Labs, Inc Zenith Parkway Loves Park, IL has been assessed by ANAB and meets the requirements of international standard ISO/IEC 17025:2005 and national standard ANSI/NCSL Z (R2002) while demonstrating technical competence in the field of CALIBRATION & TESTING Refer to the accompanying Scope of Accreditation for information regarding the types of activities to which this accreditation applies ACT-1512 Certificate Number Certificate Valid Through: 03/29/2021 Version No. 014 Issued: 03/08/2019 This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017).

2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AND ANSI/NCSL Z (R2002) ATRONA Test Labs, Inc Zenith Parkway Loves Park, IL Atif Ott Odeh TESTING Valid to: March 29, 2021 Certificate Number: ACT-1512 Chemical Specific Tests and/or Properties Measured Metals Carbon, low and high alloy steels, cast irons, tool steel, stainless steel, aluminum, copper, and nonferrous Metal and Metallic Organic and Inorganic Solids, Liquids and Gases Organic and Inorganic Solids, Liquids and Polymers Organic and Inorganic Solids, and Polymers Specification, Standard, Method, or Test Technique Chemical Composition by Spark Atomic Emission Spectrometry Items, Materials or Product Tested ASTM E415, E1086, E1251, E1999 Key or Technology Optical Emission Spectrometry (OES)/Atomic Emission Spectrometry (AES) Analyzer EDS Quantitative Analysis ASTM E1508 EDAX Material Identification Enthalpies of Fusion, Crystallization, Melting Temperature, Glass Transition Temperature, Oxygen Index Material Composition, Volatile Materials, Combustion, Ash, Filler Content Carbon Black ASTM E1252 ASTM D3677 ASTM E204 ASTM E334 ASTM D3418 ASTM E793 ASTM E794 ASTM E1356 ASTM D3895 ASTM E1131 ASTM D1603 Infrared Spectrometer Bio-Rad Excalibur w/ UMA500 Microscope Internal ATR Differential Scanning Calorimeter TA DSC Q2000 Thermogravimetric Analyzer TA TGA Q500 Page 1 of 12

3 Mechanical Specific Tests and/or Properties Measured Metals and Metallic Metals and Metallic Ductile Iron and Ductile Iron Metals and Metallic Steels Metals, Metallic, Systems and Assemblies Internal and External Threaded Fasteners, Washers and Rivets All types of Metals,, and Assemblies All types of Metals and Non Metal, and Assemblies Metal and Metallic Specification, Standard, Method, or Test Technique Metallographic Evaluation: Sample Preparation Macroetch / Microetch, Inclusion Rating, Intergranular Corrosion, Photomicrography / Light Microscopy Case Depth Average Grain Size Determining Nodularity and Nodule Count Using Image Analysis Hardness: Rockwell (HRA, HRBW, HRC, HREW, HRRW, HRMW, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T); Brinell (500 kgf to kgf) Micro-hardness (Vickers, Knoop); Leeb Determining Hardenability of Steel (end-quench or Jominy) Failure Analysis Mechanical Properties Items, Materials or Product Tested ASTM E3, ASTM E340, E381, E407, ASTM E45 (Method A), ASTM A262 (Practice A and E), ASTM E883, SAE J423 ASTM E1382, ASTM E112, ASTM E2567 ASTM E18 ASTM E10 ASTM E384 ASTM A956 ASTM A255 Atrona MET-08 utilizing Test Methods in this Scope of Accreditation ASTM F606 ASTM F606M ISO 898 Key or Technology Microscopes with Automatic Stages, Image Characterization and Automatic Microhardness Testers with Mapping Image Analysis Microscopes and Software Image Analysis Microscopes and Software Automatic Testers Furnace Quench Device Hardness Tester /technologies per this Scope of Accreditation Testers with Various Load Cells Salt Fog ASTM B117 Salt Fog Chamber Cleanliness Evaluation Magnetic Particle Inspection JDS-G169, IE2500 and Customer Supplied Test Methods or Methods Developed by the Lab Approved by the Client directly related to tests listed ASTM E1444 Scale, Stereoscope, filters Magnetic Particle Page 2 of 12

4 Mechanical Specific Tests and/or Properties Measured Metal and Metallic Metal and Metallic Powder Metals Powder Metals Metals, Wires, Rods, Fasteners, Plates, Plastics,, and Assemblies Aluminum Magnesium Products Fasteners,, and Assemblies Fasteners,, and Assemblies Fasteners,, and Assemblies Metal and Metallic Plating properties of component parts Polymers, Plastics and Composites Specification, Standard, Method, or Test Technique Liquid Dye Penetrant Examination Items, Materials or Product Tested ASTM E165 Key or Technology Liquid Dye Penetrant Notched Bar Impact (Charpy) ASTM E23 Full Size and Sub-Size Apparent Hardness of Powdered Metals Determination of Density of Compacted and Sintered Powder Metallurgy (PM) Products Tensile Mechanical Properties Tension Mechanical Properties Torque Measurement Surface Discontinuity Carburization and Decarburization Shear Strength MPIF Standard 43/ASTM B962 MPIF Standard 42 ASTM A370, E8/E8M ASTM B557 Customer-supplied or clientapproved Lab-developed Test Methods ASTM F788/F788M, F812/F812M ASTM F2328, F2328M ASME B18.8.2, MIL-STD Test 13, MIL-STD-1312 Test 20, and Customer Supplied Test Methods or Methods Developed by the Lab and Approved by the Client directly related to tests listed Direct Rockwell Hardness Mettler Balance and Density Kit Tensile tester (Up to lbf) Tensile tester (Up to lbf) Torque wrench Visual & Stereoscopic Microhardness Torque wrench, Tensile Tester (Up to lbf) Plating Thickness GMW4205, GMW4700 Microscope Ash Content ASTM D482 ASTM D5630 Polymers Melt Flow Rate ASTM D1238 Organic and Inorganic Solids Density Specific Gravity ASTM D792 Temperature Furnace Tinius Olsen Flow Indexer Precision Balance Polymers Durometer Hardness ASTM D2240 Durometer A and D Polymers Hardness Rockwell R, L and M ASTM D785 HR500 Mitutoyo Hardness Tester Page 3 of 12

5 Mechanical Specific Tests and/or Properties Measured Specification, Standard, Method, or Test Technique Items, Materials or Product Tested Polymers Flexural Modulus ASTM D790 Key or Technology Testers with Various Load Cells Polymers Water Absorption of Plastics ASTM D570 Mettler Balance and Oven Dimensional 1 Parameter / Dimensional Measurement Length: Up to 10 in Height: Up to 5 in Radius: Up to 1 in Angle: (0 to 360) Height: Up to 38 in ( L) in ( L) in 340 in ( L) µin Optical Comparator height gage CALIBRATION Length Dimensional Metrology 1 Parameter / Amplifier - Electronic Up to 1 in (21 + 4L) in Anvil Parallelism 2 Up to 1 in 16 in Optical Parallel (1 to 24) in 110 in Bench Centers 150 in Master Arbors, Electronic Amplifier Bench Center in Master Arbors, 50 in Test Bench Micrometer Linear Accuracy Up to 1 in 22 in Bench Micrometer 2 Linear Accuracy Up to 1 in 41 in Bore Micrometer, 3 point (0.2 to 6) in ( L) in Plain Ring Gages Brinell Scope 2 Resolution 0.01 mm Up to 6 mm mm Stage Micrometer Brinell Scope 2 Resolution 0.1 mm Up to 6 mm 0.12 mm Stage Micrometer Page 4 of 12

6 Length Dimensional Metrology 1 Parameter / Caliper Dial / Vernier Caliper 2 Dial / Vernier Caliper Caliper 2 Dial / Vernier Caliper Caliper 2 Caliper Checker Kalmaster Up to 72 in Up to 72 in Up to 72 in Up to 72 in Up to 72 in Up to 72 in Up to 24 in ( L) in ( L) µin ( L) µin ( L) in ( L) in ( L) in ( L) in Chamfer Gage, Dial Up to 2 in 600 in Chamfer Gage, Dial 2 Up to 2 in 610 in Depth Micrometer Analog Resolution in Depth Micrometer 2 Analog Resolution in Depth Micrometer Analog Resolution in Depth Micrometer 2 Analog Resolution in Depth Micrometer Depth Micrometer 2 ( L) in ( L) in ( L) in ( L) in ( L) in ( L) in Dial Bore Gage Up to 0.02 in 120 in Flatness Up to 2 in Surface Face, Plain Ring Gage, Plain Ring Gage, Plain Ring Gage, Plain Ring Gage, Plain Ring Gage, Plain Ring Gage,, Electronic Amp Chamfer Ring Gage, Chamfer Ring Gage,,,,,,, P&W Supermicrometer 14 in Optical Flat Page 5 of 12

7 Length Dimensional Metrology 1 Parameter / Flatness/ Parallelism (2 to 24) in 130 in, Electronic Amp Granite s 2 Local Area Flatness (Repeat Reading) Overall Flatness Height Gage Resolution in Height Gage 2 Resolution in Height Gage Resolution in Height Gage 2 Resolution in Height Gage 2 Dial/ Resolution in Height Gage 2 Dial/ Resolution 0.001in Local Area Flatness Up to 96 in Overall Flatness Up to 24 in Up to 96 in 30 µin 44 µin 62 µin (5 + (24 x L/12)) µin ( L) in ( L) in ( L) in ( L) in ( L) in ( L) in Height Master Up to 24 in ( L) in Dial//Electronic Resolution in 2 Dial//Electronic, Resolution in Dial//Electronic Resolution 50 in 2 Dial//Electronic Resolution 50 in Repeat meter Planekator/indicator Planekator/indicator Autocollimator,,,,,,, Up to 1 in ( L) in Up to 1 in (8 + 36L) in (36 + 8L) in ( L) in,, Page 6 of 12

8 Length Dimensional Metrology 1 Parameter / Dial//Electronic in Resolution 2 Dial//Electronic Resolution in Dial//Electronic Resolution in 2 Dial//Electronic Resolution in Dial//Electronic Resolution in 2 Dial//Electronic, Resolution in Dial//Electronic Resolution mm 2 Dial//Electronic Resolution mm Dial//Electronic Resolution 0.01 mm 2 Dial//Electronic Resolution 0.01 mm Calibrator Resolution in Calibrator Resolution in Up to 1 in Up to 1 in (61 + 8L) in ( L) in ( L) in ( L) in ( L) in ( L) in (48 + 9L) in ( L) in ( L) in ( L) in 60 in 21 in Length Standards (1 to 60) in ( L) in Levels Up to in/ ft 190 in/ft,,,,,,,,,,, Electronic Amplifier, Electronic Amplifier,, Electronic Amp,, Plug Gages Page 7 of 12

9 Length Dimensional Metrology 1 Parameter / Levels 2 Up to in/ ft 200 in/ft Micrometer, Inside (1 to 10) in ( L) in Micrometer, Inside (10 to 40) in ( L) in OD Micrometer Linear Accuracy OD Micrometer 2 Linear Accuracy OD Micrometer Analog Linear Accuracy OD Micrometer 2 Analog Linear Accuracy Plain Plug Gage (Mahr) Plain Plug Gage (P&W Supermicrometer),, Plug Gages P&W Supermicrometer,,, Electronic Amp ( L) in ( L) in ( L) in ( L) in Up to 20 in Up to 10 in ( L) in ( L) in Plain Ring Gage (0.125 to 14) in (11 + 9L) in Mahr CiM P&W Supermicrometer Mahr CiM Protractor 0 o to 360 o o Sine Bar, Sine Bar Up to 20 in ( L) in Squares, Steel Up to 24 in (59 + 9L) in Taper Thread Plug Pitch Diameter Taper Thread Plug Major Diameter Taper Thread/Plain Plug Step Height Taper NPTF 6 Step Plain Plug Diameter ( to 4) in ( L) in ( to 4) in ( L) in Up to 1 in 230 in ( to 4) in ( L) in, Electronic Amplifier, Granite Square, Surface Plate P&W Supermicrometer Taper Block, Wires P&W Supermicrometer Taper Block Electronic Amp P&W Supermicrometer Taper Block Page 8 of 12

10 Length Dimensional Metrology 1 Parameter / Taper Thread Rings Thread Ring Gage Pitch Diameter ( to 3) in Pitch Diameter at End Step Height (0.072 to 1) in (1 to 7.5) in ( PD) in 230 in ( L) in ( PD) in Thread Measuring Wires Up to 0.25 in 16 in Thread Plug Gage Pitch Diameter Thread Roll Gage Elements Up to 10 in ( L) in Taper Thread Plugs, Gage Blocks, Electronic Amp Thread Set Plugs Mahr CiM Mahr CiM Thread Measuring Rolls P&W Supermicrometer Thread Measuring Wires Lead Flank Angle (0.01 to 0.5) in (0 to 45) ( L) in Optical Comparator Universal Length Measuring Machine Up to 2 lbf ( L) in lbf Force Gage V Block (6 x 6 x 6) in 130 in Granite Square, Surface Plate, Electronic Amp Extensometers 2 Up to 1 in ( L) in Extensometer Calibrator Optical Comparator 2 X, Y Linear Accuracy Angle Accuracy X, Y: Up to 6 in X, Y: Angle: (90, 180, 270, 360) ( L) in ( L) in Glass Scale, Magnification Scale, Sphere Kit; Angle Square Page 9 of 12

11 Mass 1 Parameter / HRA HRBw HRC HREw HR15N Rockwell Hardness Testers 2 HR30N HR45N HR15TW HR30TW HR 45TW 0.83 HRA 0.58 HRA 0.51 HRA 1.4 HRBW 1.6 HRBW 0.92 HRBW 0.90 HRC 0.63 HRC 0.60 HRC 1.1 HREW 0.89 HREW 0.77 HREW 0.87 HR15N 0.87 HR15N 0.68 HR15N 1.1 HR30N 0.87 HR30N 0.78 HR30N 0.85 HR45N 0.84 HR45N 0.75 HR45N 1.7 HR15TW 1.3 HR15TW 1.4 HR15TW 1.6 HR30TW 1.2 HR30TW 1.4 HR30TW 1.6 HR45TW 1.3 HR45TW 1.5 HR45TW Certified Test Blocks Page 10 of 12

12 Mass 1 Parameter / Brinell Hardness Testers 2 Vickers/Knoop Microhardness Testers 2 HBW 10/500 HBW 10/500 HBW 10/500 HBW 10/3 000 HBW 10/3 000 HBW 10/3 000 HK 100 gf HK 500 gf HK 500 gf HV 100 gf HV 500 gf HV 500 gf HV gf HV gf HV gf 2.3 HBW 2.1 HBW 2.5 HBW 9.3 HBW 5.3 HBW 13 HBW 23 HK 16 HK 36 HK 26 HV 12 HV 37 HV 11 HV 13 HV 26 HV Certified Test Blocks Certified Test Blocks Leeb Hardness Testers 2 HLD 13 HLD Standardized Test Blocks Durometers Pressure (Hydraulic/ Pneumatic) Magnetic Particle Inspection Machine (Magnaflux) Type A (0 to 100) Duro Type M (0 to 100) Duro Up to 500 psig (500 to 3 000) psig (3 000 to ) psig ( to ) psig Ammeter: Up to 4 ka Timer: Up to 10 s White light: Up to 190 fc Black light: Up to 1900 µw/cm 2 Gauss meter: Up to 100 G 50 lb weight test 30 lb weight test 10 lb weight test 1.2 Duro A 1.6 Duro M 0.30 psig 2 psig 9.3 psig 44 psig 69 A + 2 A/kA s s/s 1.6 fc fc/fc 71 µw/cm G G/G 2.8 g 1.7 g 1.2 g Three Beam Balance Balance Master Pressure Gages Current shunt Timer White light meter Black light meter Gauss meter ASTM Class F weight ASTM Class F weight ASTM Class 7 weight Vacuum (0 to 24) in Hg 0.6 in Hg Master Pressure Gage Profilometer Profilometer Standard Tensile/Compression Testing Machines 2 Ra: (10 to 20) in Ra: (110 to 120) in Ra: (10 to 20) in Ra: (110 to 120) in (12 to 300) lbf (200 to 5 000) lbf (5 000 to ) lbf ( to ) lbf 2.6 in 3.4 in 2.6 in 3.4 in 0.16 lbf 3.1 lbf 15 lbf 110 lbf Master Three Patch Reference Standard MTI SJ-400 Profilometer Master Load Cells and Page 11 of 12

13 Mass 1 Parameter / Torque Wrenches 2 Up to 50 lbf in Up to 400 lbf in Up to 1000 lbf in Up to 250 lbf ft Up to 600 lbf ft 0.24 lbf in 1.6 lbf in 3.7 lbf in 1 lbf ft 2.4 lbf ft CDI Torque Calibrator Notes: 1. Calibration and Measurement Capability (CMC) is expressed in terms of the measurement parameter, measurement range, expanded uncertainty of measurement and reference standard, method, and/or equipment. The expanded uncertainty of measurement is expressed as the standard uncertainty of the measurement multiplied by a coverage factor of 2 (k=2), corresponding to a confidence level of approximately 95%. 2. On-site calibration service is available for this parameter, since on-site conditions are typically more variable than those in the laboratory, larger measurement uncertainties are expected on-site than what is reported on the accredited scope 3. This scope is formatted as part of a single document including Certificate of Accreditation No. ACT Page 12 of 12