CHL Laboratory refrigerators

Size: px
Start display at page:

Download "CHL Laboratory refrigerators"

Transcription

1 Application storing water and sewage samples, piezometer leachate storing ASA, GC or HPLC calibration standards storing reagents chemical storage general storage door lock (option) fan LCD display adjustable shelf with slide set 4+

2 Advantages single or double chamber versions aluminium (NEW + RANGE!) or stainless steel interior (depending on model) housing, depending on model: powder coated sheet, stainless steel linen finish (INOX/G) or polished (INOX/S) thermal insulation - polyurethane foam solid or glass (*/A option) door type forced air convection heating and cooling systems to hold set temperature regardless of ambient conditions wheels with 200 model defrosting function two temperature ranges available: 0 +0 C C (*/T option) LCD time and temperature display microprocessor temperature and time control temperature sensor fail alarm power failure control system real time clock sound alarm self-check function (auto control) Program possibilities single segment temperature-time profile time program priority adjustable start delay feature (from min to 99,59 h) adjustable time of holding set temperature (from min to 99,59 h), or continuous operating over temperature sound alarm overview of set parameters during operating time recording min, average and max temperature value for temperature-time segment Temp. [ C] 20 C D Programming the range T 9 C TIME 9 C - parameter set by User: D - adjustable start delay ( min...99,59 h) T - set temperature TIME - set time 0,5h 5h Time [h] All POL-EKO-APARATURA products can be provided with IQ, OQ, PQ qualifications All POL-EKO-APARATURA products can be supplied with a calibration certificate issued by an accredited Measurement Laboratory. Further information is available on our website: 2

3 NEW + RANGE!!! Models were previously available with plastic interior. These models are available now as new + range with aluminum interior and adjustable shelves! Housing remains powder painted. New range of gives additionally possibilities of any chambers combination due to the same base structure. Stainless steel interior and housing on request! Standard equipment solid door temperature range 0 +0 C RS 22 interface; RS 22 cable must be purchased additionally (RSK) wire shelves (with slides set) in case of aluminum interior and stainless steel wire shelves in case stainless stainless steel interior manfacturer s test certificate at +4 C operation manual in English and English menu (other languages on request) over temperature protection.0 class according to DIN 2880 Options and accesories INOX DIN.2 RS 422 RS 485 RS 22 RS 422 RS 485 KAFKA 9 5 IQ OQ PQ SMS PWP

4 Single chamber TB 5 INOX Available options */T - extended temperature range to -0 C */A - external glass door PLUS - automatic defrosting function during operating A mini refrigerator TB 5 INOX with an additional battery power supply guarantees continuous operating in case of power failure. Model Parameter air convection chamber capacity door type temperature range controller [I] [cu ft] [ C] [ F] 68 2,4 50 5,2 forced ,8 0,5 7, ,2 solid / glass (option) / (option) / (option) microprocessor with external display 65 48,2 interior aluminum / stainless steel housing width overall dims [mm] height depth width internal dims [mm] height depth nominal power [W] weight [kg] temperature accuracy [ C] every 0, 2 temperature fluctuation at +4 C [ C] ±0,5 ±0,5 ±0,5 ±0,5 ±0,5 ±0,5 ±0,5 ±0,8 over temperature protection class.0 according to DIN 2880 voltage 50 /60 Hz [V] 0-20/ shelves fitted / max 2/2 /4 /4 4/6 4/7 / / 2 x / warranty manufacturer - working capacity of chamber can be smaller 2 - fluctuation measured in centre of the chamber - two columns with shelves each powder coated sheet / stainless steel (INOX/G or INOX/S) 24 months POL-EKO-APARATURA powder coated sheet / stainless steel (INOX/S) powder coated sheet / stainless steel (INOX/S) ±0,8 2 x / 4

5 Double chamber Available options for each chamber */T - extended temperature range to -0 C */A - external glass door PLUS - automatic defrosting during operating There is a possibility to combine different sizes of ST+ and + chambers between models ST/ (e.g ST 2+/ +) Example of configuration To configure a double chamber laboratory refrigerator, e.g.: - upper chamber with solid door and temperature range 0 +0 C - lower chamber with solid door and temperature range C, you select: for 50/50 model: 50/50 and 50/T option for lower chamber Model /+ //+ 2/2+ 2/+ 2/4+ /+ 50/50 Parameter air convection upper/lower chamber capacity door type temperature range controller [l] [cu ft] [ C] [ F] forced 68/68 68/68/68 50/50 50/200 50/ / /294 2,4/2,4 2,4/2,4/2,4 5,2/5,2 5,2/7,0 5,2/8,5 7,0/7,0 0,/0, solid / glass (option) / (only for 50/50) / (only for 50/50) microprocessor with external display separate for each chamber interior aluminum (stainless steel on request) aluminum / stainless steel housing overall dims [mm] internal dims [mm] (each chamber) nominal power [W] weight [kg] temperature resolution [ C] 2 temperature fluctuation at +7 C [ C] over temperature protection voltage 50/60Hz [V] shelves fitted / max warranty manufacturer width height depth width height depth - working capacity of chamber can be smaller 2 - fluctuation measured in centre of the chamber powder coated sheet (stainless steel on request) / / every 0, ±0,2 ±0,2 ±0, ±0, ±0, ±0, class.0 according to DIN / /2 2/2 /4 /4 /4 /4 24 months POL-EKO-APARATURA powder coated sheet / stainless steel (INOX/S) ±0,5 2/6 5

6 Parameters list Parameters list Features interior housing air convection fan speed regulation automatic fan shut down after completing the program air-flap control (flap diameter 7 mm) system defrosting function automatic defrosting function external display microprocessor control of time and temperature (and humidity in KK; light with FIT option) temperature-time profile (and humidity in KK) program priority cycle run of the program user programs memory start delay adjustable heating up time adjustable hold at set point (temperature; humidity in KK) overview of parameters during operating time recording the min, average and max temperature (and humidity in KK) value for each segment over/under temperature and humidity sound alarm (humidity in KK) over temperature protection.0 class according to DIN 2880 over/under temperature protection according to DIN 2880 temperature sensor fail alarm (and humidity sensor fail alarm in KK) power failure control system real time clock sound alarm interface Ethernet connection and remote control via Internet measurement memory self-check function (auto control) Administrator function access control via login manufacturer s test certificate 24 months warranty CE mark manufacturer s certificates PN-EN ISO 900, PN-N 800 plastic (ZLN 75, 45, 80) aluminum stainless steel (ST/ 500, 700, 200 INOX ; ZLN 25, 200, 00) powder coated sheet stainless steel (ST/ 500, 700, 200 INOX ; ZLN 25, 200, 00 INOX) natural forced % % (CL/SL/SR 400/750/000) manual automatic heating cooling (ST//IL/KK) (CL/SL 5, 2) LED LCD 5.7 LCD touch screen segment 6 segment 9 segment temperature time (ST and IL in STD with FOT/FIT option) 20 min...99,59 h date/time min...99,59 h min...99,59 h min...999,59 h class: RS 22 at -0 C at +4 C at +25 C and 60% rh at +7 C at +05 C at +70 C

7 Parameters list Parameters list ST P* TOP+ ZL CL IL SL SR KK ECO STD TOP+ STD TOP+ ECO STD TOP+ STD STD TOP * - basic version of thermostatic cabinets

8 Options and accessories Options and accessories Options and accessories, 5 internal glass door P 6 ST TOP+ ZL ECO CL STD TOP+ STD IL TOP+ ECO SL STD TOP+ SR STD KK STD TOP+ Order no. */C external glass door */A 4 door with viewing window */A internal socket, 4, 5 interior lighting door lock wire shelf GNZ OWW ZKL */P stainless steel wire shelf */P INOX perforated shelf */PP glass shelf */PL reinforced shelf */PW extended temperature range to +50 C extended temperature range to +60 C extended temperature range to +70 C ST/50 ST/60 ST/70 reinforced version low temperature version photoperiodic system - FOT phytotron system - FIT automatic defrosting function over temperature protection system according to DIN 2880 stainless steel cuvettes stainless steel drawers */W */T FOT FIT PLUS.. */** KUW */SW access port for external sensor OCZ 5 humidity measurement PHR open door alarm SOD door openings counter additional Pt 00 temperature sensor LOD */Pt00 HEPA - fresh air filter */HEPA RS 422 interface (instead of RS 22) */RS422 RS 485 interface (instead of RS 22) */RS485 wheels QLK/* 2 table with wheels */S RS 22 cable RS 422 cable RS 485 cable EasyLab-T PLUS software RSK RSK/422 RSK/485 EasyLab-T dot printer TM-U20D Kafka thermal printer calibration in 9 points KAFKA BRT/9 chamber calibration in 5 points on shelf IQ, OQ, PQ qualification BRT/5 IQ/OQ/PQ SMS Info container for deionized water container for waste water test s results memory SMS INFO KK/Z KK/K PWP FIT shelves independent control FIT/R2 * - model (e.g. ST +, IL 5, ZL 75) ** - over temperature protection system (e.g..) - for double chamber units, the function available for both chambers separately 2 - unavailable for 400, 500, 700, 750, 200, 000 and 50/50 models, ST/ 4+ and 5+ - only for ZL 75, 45, in case of SL range, maximum temperature is reduced to +250ºC 5 - in case of CL/IL in TOP+ version, maximum temperature is reduced to +70ºC 6- basic version of thermostatic cabinets 8