New Energy Research Institute at South China University of Technology

Size: px
Start display at page:

Download "New Energy Research Institute at South China University of Technology"

Transcription

1 New Energy Research Institute at South China University of Technology 5th Floor, B5 Building, South China University of Technology, Guangzhou Higher Education Mega Center, Guangzhou , China

2 Introduction Guangzhou Higher Education Mega Center (GHEMC): (Chinese: 广州大学城 ) is an area featured by higher education institutions, located in the Southeast of Guangzhou on Xiaoguwei Island (Chinese : 小谷围岛 ) in Panyu District, Guangzhou, China. With an area of approximately 17.9 km2 and 3.53 millions square meters of indoor space, the complex is capable of accommodating 350 to 400 thousand people. Ten local higher education institutions, including South China University of Technology (SCUT), set up new campuses on the island with a total of 120,000 students.

3 Aerial view of GHEMC and SCUT campus SCUT

4 SCUT University B5 Building

5 New Energy Research Institute Our New Energy Research Institute is located in B5 Building.

6 New Energy Research Institute We have Over 1000 m 2 lab area, 1000 m 2 office area. Cost over 24 millions RMB equipments, including in-situ Raman Spectroscopy, Grazing Incident X ray diffraction, Pulsed Laser Deposition, Solartron, IM6 & Zennium, Ivium and Arbin Electrochemical Workstations, Vacuum Glove Boxes, over twenty High Temperature and Intermediate Temperature Furnaces et al. 5 professors, 2 associate professors and 2 lecturers. Including two 1000plan specially-appointed professors, Prof. Meilin Liu and Prof. Shaowei Chen.

7 Labs Over 1000 m 2 lab area.

8 In situ LabRAM HR Evolution Raman system a) b) The LabRAM HR Evolution Raman System is equipped with deeply depleted thermoelectrically cooled CCD array detector, an Arion laser (514.5 nm) and long working distance 50 objective lens.

9 Grazing Incident X ray diffraction

10 Pulsed Laser Deposition (a) (b) (c) (d)

11 Vacuum Glove Boxes

12 Electrochemical Workstations Solartron 1260/1287 Ivium Stat. IM6 & Zennium Arbin 40 Channels Wuhan Landian CT2001A Wuhan Landian CT2001C

13 Gas Chromatograph (GC) Agilent (G3440B): TCD/FID, 4 C~450 C.

14 Dilatometer NETZSCH DIL 402 C Temperature: Room temperature to 1600 Atmosphere: Air, or H2, CH4, CO

15 Specific Surface Area and Pore Analyzer Micromeritics ASAP2020HD88

16 High and Intermediate Temperature Furnaces Two of them are 1700 o C, and two of them 1400 o C. Two of them are 1700 o C, and two of them 1400 o C. Several 1100 o C furnaces for solid oxide fuel cell testing. Two 1200 o C vcancum tubular furnace.

17 Structure and Morphology Characterization Nikon E200 fluorescence microscope, Benchtop LVEM5 SEM & TEM Resolution: TEM mode < 2nm, SEM mode < 3nm Phi X-Tool X-Ray Photoelectron Spectroscopy,XPS spot sizes from 7.5 μm to 400 μm LB film trough Bruker 400M NMR Contact Angle Metering System

18 Spectroscopies UV-vis absorption spectroscopy For thin film and solution 2300ⅡUV-vis Spectro Photo Meter For powder and solution Nicolet 6700 Infrared Spectroscopy Wavelength range: 7, cm-1 FT-NIR Analyzer Wavelength range: nm Quanta Master Fluorescence Spectrophotometer With picosecond resolution Wavelength tunable monochromatic light source. Wavelength range: 300nm-1200nm

19 Advanced systems Glovebox & thermal evaporator- Keithley 2636B source meter system for metal deposition and optoelectronic measurements TGA/DSC Temperature: RT~1300K Rate: 0.02~150/250 K/min System for Water split and photocatalysis research

20