1 WLB Industrial LED Light Bar (DC) Datasheet Banner s WLB is an ultra-bright LED fixture that features an even light output for a no glare glow. Suitable for a variety of environments and applications, including work stations, machine lighting, control cabinets, and manufacturing lines, the WLB uses advanced LED lighting technology to provide a high-quality and maintenance free industrial lighting solution for years. Highly energy efficient for overall cost savings High/Low/Off switch Daisy chain power to multiple lights Metal housing, shatterproof window Easy installation with snap clips, or a choice of magnetic or angle brackets WLB Industrial LED Light Bars are available as cascadable models that can be "daisychained" together for a continuous length of lighting, with a minimum of wiring. Each light bar can be turned to high, low, or off independently of the other lights, upstream or downstream, in the chain. A double-ended accessory cordset must be used between each pair of cascading lights. to 0 V dc Models Models Lighted Length (mm) Connector Lumens WLBC85PBQ WLBC570PBQ pin Euro-style WLBC850PBQ WLBC0PBQ 0 00 WLBC85PB WLBC570PB m (6.5 ft) cable WLBC850PB WLBC0PB 0 00 Specifications Operating Voltage to 0 V dc Use only with a suitable Class power supply. Supply Current Light Length (mm) Max Current Draw (A) Typical Current Draw (A) V dc V dc 0 V dc Original Document 76 Rev. D November 0 76

2 WLB Industrial LED Light Bar (DC) Supply Protection Circuitry Protected against reverse polarity and transient voltages Light Characteristics Color: Daylight white Color temperature (CCT): 5000K (±00K) Lumen output: 600 (±5%) per foot, typical at 5 C (77 F) Luminous efficacy: 80 lumens/watt typical at V dc at 5 C (77 F) CRI: 85, typical LED Lifetime Lumen Maintenance - L 70 When operating within specifications, output will decrease less than 0% after 50,000 hours. Push Button II = 00% light intensity I = 50% light intensity O = Off Construction Anodized aluminum housing; polycarbonate window and end caps; stainless steel mounting brackets Spacing Criterion Vertical:. Horizontal:. Mounting Snap clips; optional magnetic mount or swivel bracket accessories available Connections Integral -pin Euro-style QD (-pin connecting cordset required for QD models); or m (6.5 ft) integral cable Environmental Rating IEC IP50 Vibration and Mechanical Shock Vibration 0-55 Hz.m p-p amplitude per IEC Shock 5G ms duration, half sine wave per IEC Operating Temperature 0 C to +70 C ( 0 F to +58 F) Light output begins to decrease above 50 C ( F) and will be approximately 65% of max intensity at 60 C (0 F) and 0% of max intensity at 70 C (58 F) Storage Temperature 0 C to +70 C ( 0 F to +58 F) Test Data LM-79, LM-80, TM- Certifications Application Note When connecting cascadable lights in series it is important not to exceed the maximum current limitation of Amps Maximum length of light at V dc:. m (.6 ft) Maximum length of light at V dc:. (9.8 ft) Maximum length of light at 0 V dc:. m (0. ft) Spacing Criteria (SC) The spacing criteria is the fixture-spacing-to-mounting-height ratio and aids in laying out a pattern of fixtures. Multiply the spacing criteria by the mounting height to get the maximum fixture spacing that still provides even illumination (no shadowing between fixtures). Luminaire Spacing = SC Height to Illuminated Plane The mounting height is the distance from the fixture to the surface you are lighting. - Tel: P/N 76 Rev. D

3 WLB Industrial LED Light Bar (DC) Light Characteristics CD (candela) Polar Candela Distribution Vertical Angle: Vertical 90 Horizontal Isolux Pattern Mount height of meter ( m) 0. m 0. m 0.5 m 0.7 m 0.8 m. Illuminance at a Distance Center Beam (lux) Beam Width (m),8 lux 0. m 0.7 m,58 lux 0.8 m. m 67 lux. m. m 9 lux.6 m.8 m 66 lux..5 m 7 lux. m. m Vert. Horiz. 50 lux 5 lux 00 lux 75 lux 50 lux 5 lux 0 lux 5 lux 50% max. candela Vertical Spread: 0.5 Horizontal Spread: 8.8 Figure. 85 mm Models P/N 76 Rev. D - Tel:

4 WLB Industrial LED Light Bar (DC) CD (candela) Polar Candela Distribution Vertical Angle: Vertical 90 Horizontal Isolux Pattern Mount height of meter ( m) 0. m 0. m 0.5 m 0.7 m 0.8 m. Illuminance at a Distance Center Beam (lux) Beam Width (m),66 lux 0. m 0.7 m,68 lux 0.8 m. m,050 lux. m. m 607 lux.6 m.7 m 80 lux.. m 8 lux. m. m Vert. Horiz. 00 lux 50 lux 00 lux 50 lux 00 lux 50 lux 5 lux 0 lux 50% max. candela Vertical Spread: 0.5 Horizontal Spread: 8. Figure. 57m Models CD (candela) Polar Candela Distribution Vertical Angle: Vertical 90 Horizontal Isolux Pattern Mount height of meter ( m) 0. m 0. m 0.5 m 0.7 m 0.8 m. Illuminance at a Distance Center Beam (lux) Beam Width (m),55 lux 0. m 0.7 m,68 lux 0.8 m. m,6 lux. m. m 85 lux.7 m.9 m 696 lux. m.6 m 50 lux.5 m. m Vert. Horiz. 50 lux 75 lux 00 lux 5 lux 50 lux 75 lux 5 lux 0 lux 50% max. candela Vertical Spread: 0.7 Horizontal Spread: 0. Figure. 85m Models - Tel: P/N 76 Rev. D

5 WLB Industrial LED Light Bar (DC) CD (candela) Polar Candela Distribution Vertical Angle: Vertical 90 Horizontal Isolux Pattern Mount height of meter ( m) 0. m 0. m 0.5 m 0.7 m 0.8 m. Illuminance at a Distance Center Beam (lux) Beam Width (m),55 lux 0. m 0.7 m,85 lux 0.8 m. m,55 lux. m. m 986 lux.7 m.8 m 8 lux. m.5 m 67 lux.5 m. m Vert. Horiz. 600 lux 500 lux 00 lux 00 lux 00 lux 00 lux 50 lux 5 lux 50% max. candela Vertical Spread: 0. Horizontal Spread: 9.7 Figure. m Models Wiring + Female Wiring Key: = Brown = Blue 0 V dc Male P/N 76 Rev. D - Tel:

6 WLB Industrial LED Light Bar (DC) Dimensions mm [.6 ] L L 0.5 mm [0. ] 6 mm [.8 ] 0.5 mm [0. ] M x M x Model L L WLBC85PBQ 98 mm (.7 in) m (.6 in) WLBC570PBQ 58m (.8 in) 6m (.7 in) WLBC850PBQ 86 mm (.9 in) 88 mm (.8 in) WLBC0PBQ mm (5.0 in) 66 mm (5.9 in) WLBC85PB 98 mm (.7 in) mm (. in) WLBC570PB 58m (.8 in) 595 mm (. in) WLBC850PB 86 mm (.9 in) 877 mm (.5 in) WLBC0PB mm (5.0 in) 59 mm (5.6 in) Accessories -Pin Threaded M/Euro-Style Cordsets Model Length Style Dimensions Pinout (Female) MQDC-06 MQDC-5.8 m (6 ft).57 m (5 ft) Typ. MQDC-0 MQDC-50 MQDC-06RA MQDC-5RA 9. m (0 ft) 5. m (50 ft).8 m (6 ft).57 m (5 ft) Straight Typ. [.6"] M x ø.5 MQDC-0RA 9. m (0 ft) Right-Angle 0 Typ. [.8"] = Brown = White = Blue = Black MQDC-50RA 5. m (50 ft) M x ø.5 [0.57"] Tel: P/N 76 Rev. D

7 WLB Industrial LED Light Bar (DC) -Pin Threaded M/Euro-Style Cordsets Double Ended Model Length Style Dimensions Pinout MQDEC-0SS MQDEC-0SS MQDEC-06SS 0. m ( ft) 0.9 m ( ft).8 m (6 ft) 0 Typ. [.58"] MQDEC-SS.66 m ( ft) MQDEC-0SS MQDEC-0SS MQDEC-50SS 6. (0 ft) 9. m (0 ft) 5. m (50 ft) Male Straight/ Female Straight M x ø.5 [0.57"] Typ. [.7"] Female M x ø.5 [0.57"] Male MQDEC-0RS MQDEC-06RS MQDEC-RS MQDEC-0RS MQDEC-0RS 0.9 m ( ft).8 m ( ft).66 m ( ft) 6. (0 ft) 9. m (0 ft) Male Right-Angle/ Female Straight M x ø.5 [0.57"] Typ. [.6"] 0 Typ. [.8"] = Brown = White = Blue = Black MQDEC-50RS 5. m (50 ft) ø.5 [0.57"] Typ. [.7"] M x -Pin Threaded M/Euro-Style Splitter Cordsets Flat Junction Model Branches (Female) Trunk (Male) Pinout CSB-M0M0 No branch No trunk CSB-M0M No trunk Female CSB-MM CSB-M8M CSB-M5M CSB-M5M x 0. ( ft) 0. ( ft).5 (8 ft).57 m (5 ft) 7.6 (5 ft) CSB-UNT5M 7.6 (5 ft) Unterminated Male Ø.5 [0.57"] M x 0 Typ. [.58"] 5 [.8"] Ø.5 [0.8"].0 [.69"] 8.0 [0.7"] Typ. [.7"] Ø.5 [0.57"] M x = Brown = White = Blue = Black P/N 76 Rev. D - Tel:

8 WLB Industrial LED Light Bar (DC) Mounting Brackets LMBWLB Replaces the bracket that ships with the WLB light Stainless steel Includes snap clips, screws, and insulator caps 6 0 X Ø6.5 LMBWLB-80S Swivel bracket kit allows 80 of movement Ø LMBWLBMAG Magnetic mounting bracket for easy attachment to steel and iron surfaces Ø6 Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. - Tel: