Energy Compliance Information

Similar documents
Energy Compliance Information

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

Feature Zone IECC 2009 IECC

Energy Efficiency Requirements 9.36

Boulder City NV Prepared by (Print Name) Signature Date

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Standards for Jackson EMC s Right Choice Program Revised: June 2011

IECC Residential Significant Changes Summary. Tier I

FIELD COPY ATTACHMENT

Homes. Plan Review Input Form. Office Use: P l an Rev iew Contro l Nu mb er

Table Air Barrier and Insulation Inspection Component Criteria

Hardin County Planning and Development Commission

Charter Township of Washington

IRC 2012 Key Changes

Project Type: New Home Addition Alteration (Describe)

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

2014 British Columbia Building Code Changes

New Hampshire Residential Energy Code

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

RESIDENTIAL ENERGY CODE. The 2015 International Energy Conservation Code (IECC) as modified below.

Residential Requirements of the Texas Energy Code 2009 IRC Chap 11

General Contractor: Company Name: Location of Proposed Structure: Tax Map #: Lot #:

Questar ThermWise Duct Technical Specifications

Building with Ducts in Conditioned Spaces Conditioned Attics

Effective Date: April 25, 2016 Revised: November 7, 2017

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Town of Farragut RESIDENTIAL CONSTRUCTION ENERGY EFFICIENCY. LAST UPDATE: July 03, 2014

Please Submit Plans and Forms Electronically.

Rebates for Improvements Home Efficiency Program Fort Collins Utilities

REScheck Software Version Compliance Certificate

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

Plan Check & Field Inspection Guide

2015 Michigan Residential Code Energy Worksheet for Single-family Additions, Alterations, Renovations and Repairs

Performance Requirements and Options in the International Energy Conservation Code. Mike Turns, Senior Program Manager

Compliance Certificate

Prescriptive Checklist for the 2015 Washington State Energy Code

1. When using the REScheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

ASHRAE 62.2: What s New in 2016

ERI vs. Performance Path: Which is better for the builder?

THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012

By James Tente, MCP, CBO,CFM

Presented by: Stephen Carr Regional Building Science Manager (386)

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

Compliance Certificate

1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7

2012 Washington Energy Code - Residential.

2012 IECC Residential with State Adopted Changes

Michigan Energy Code Training and Implementation Program

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

Home Performance with ENERGY STAR Guidelines

2010 National Building Code Adoption and Associated Process Changes

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

Healthier Home Environments Benefit Everyone

Compliance Certificate

Residential Codes FAQs: 2015 International Energy Conservation Code (IECC) with MA Amendments & MA Stretch Energy Code

About Southface. Southface promotes sustainable homes, workplaces and communities through education, research, advocacy and technical assistance.

Residential Data Collection Checklist 2009 International Energy Conservation Code Climate Zone 2

Healthy, Durable, Low Energy Buildings: Thermal: High R. Thermal bridges. Fundamentals, techniques, and pitfalls

Appendix RA Air Sealing and Insulation Key Points COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA

INSULATION BATT (1) (2) Code Reference: 2016 Title 24, Reference Appendices RA3.5. Pressure or Friction Fit

City of High Point Airport Overlay District Noise Level Reduction Design Standards

1 Exam Prep Florida Building Code-Energy Conservation Edition Tabs and Highlights

ASHRAE 62.2: What s New in 2016

2018 IECC Residential Provisions with Corresponding IRC Sections

Copyright 2010 International Code Council

Montana Homebuilder Brief: Residential Energy Code 1

Measure 1 Seal Ducts Components Inspected

RESIDENTIAL ENERGY EFFICIENCY

Condi1oned A3cs and Crawlspaces. Making the Decision. Find This Presenta1on. Helpful Informa1on. page/

1998 and 2000 International Energy Conservation Code Version 3.0 April 2000

Construction Report NYSERDA Residential Performance Challenge

Chapter 1: Compliance

Crawl Space Moisture Control

REScheck Compliance Certificate Massachusetts Energy Code REScheck Software Version 3.6 Release 1 Data filename: O:\REScheck 38\38258.

Air Sealing, Infiltration & Ventilation

REScheck Software Version Compliance Certificate

Supplementary Standard SB-12. Energy Efficiency For Housing

Single Family Residence Building Permits

Air Sealing for 5 ACH 50

SpacePak Manual J Load Analysis Project Sheet

Section 22A. Lead Paint Risk Factor NONE-HIGH FLOOR INSULATION FOR CONVENTIONAL HOMES TABLE OF CONTENTS

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

Residential Plan Review for New One and Two Family Dwellings

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

Crawl Spaces and Basements: Defining the Building Envelope

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

2009 IECC Chapter 1 Additions, alterations, renovations or repairs.

BASIC VENTILATION REQUIREMENTS

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

COMMERCIAL ENERGY EFFICIENCY

SUSTAINABLE ENERGY ANALYTICS

Residential New Construction Simulated Performance Alternative (SPA) Guide Updated 1/12/2019

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

QCI HEP Pre Exam Quiz

Interpretation Variables and Common Areas of Confusion. Of the 2009 IECC

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace

Upcoming Courses.

Transcription:

Midway City Building Safety 435-654-7441 X 2 (Fax) 435-654-4120 Energy Compliance Information Meeting the energy code in today s structures requires the integration of all systems within the thermal envelope, including the HVAC system(s), insulation and sealing. There are three methods to show compliance with the energy code: prescriptive, REScheck (formerly MECcheck), and performance. The REScheck has been used for many years, and many of you are most familiar with this method. The software is available at the DOE website, either to download or use over the web; just Google Rescheck. The second method is to use the prescriptive R- and U-values for our zone 6; I consider this the easiest since a lot of take-off information is not required to input into the REScheck. The third method is a performance-based method. Frankly, I have never had anyone choose this method, as it requires an analysis of the performance of the proposed structure to be compared to another comparable existing home. It is still an option available should you choose. The thermal envelope is defined as where the insulation is placed in the structure which encloses the conditioned space. This is always the exterior walls (excluding garage), and can be either the roof or ceiling, and either the basement walls or ceiling. If an area is considered to be within the thermal envelope, it must be insulated and receive conditioned air.

Walk-outs and slab-on-grade need the slab insulated by one of the methods shown below: Regardless of the method you choose, the information submitted must correlate with the information provided on your plans as far as insulation values, U-values of windows, efficiency of the HVAC system, and input data shown on the gasline schematic. The heat loss/heat gain submittals must also correlate with the information on the plans concerning building component types, square footages, and U- and R- values. I check all to see that they match, and I require you to assure they match prior to submittal, as this is one of the most-often written comments at plan review. Consequently, as of I July 1, 2011 this Energy Compliance Worksheet must be submitted at application. Information which impacts energy-compliance worksheet: Fuel-fired appliances requiring outside combustion air must be in a space separated from the conditioned portion of the dwelling by insulated walls and ceiling, where applicable. All ducts, both supply and return, shall be insulated to a minimum of R-8, and water lines shall be protected from freezing in this room. All present-day construction is considered unusually tight, requiring all combustion air be supplied from the exterior. There shall be a gasketed, tight-fitting door to the room. New homes with 90+ HVAC systems must extend both pipes to the exterior.

All HVAC ducts must be sealed. This means both transverse and longitudinal joints. Air leaking from ducts keeps the vent at the end of the line from getting the air required. As tight as we are building homes these days, kitchen hoods over 400 cfm require make-up air, and there is to be an interlock between the fan switch and the make-up air system. If the home has an unfinished basement, and you wish to size the HVAC system for this space, this must be indicated in the hl/hg calculations, and then the insulation must be on the exterior walls of the basement, and the ducts do not have to be insulated. There will need to be one supply and one return duct opening into the basement, and the HVAC system must be multi-stage. Conversely, if the HVAC system is not sized for the future basement finish, the insulation shall be placed in the floor between the main floor and basement, all ducts in the basement must be insulated to a minimum of R-8, and there shall be no openings of the ducts into the unfinished space. Heat Loss/Heat Gain calculations are to be done for the home, and our climate data is 5-degrees for heating and 91-degrees for cooling. Our base altitude is about 5525, close to that of Cedar City if you are using a program that makes you name a city, but our heating and cooling days are to be those listed above. I have Manual J/S and Manual D summary sheets and one must be filled out for each HVAC unit in the house. Make sure the HL/HG calculations are done using the correct R- and U-values for the different components as shown on the plans and in your energy-compliance worksheet.

Home Energy Compliance Worksheet Required for all new home permits submitted beginning 7/1/11 Applicant Name: Address of structure: Basic structure information: Basement: Unfinished square feet finished square feet crawl space square feet One story home, total square feet: two story home, total square feet: Thermal Envelope: Insulation R-values and type: (fiberglass batts or blown-in, cellulose blown-in, spray foam (open or closed cell), rigid, etc. Attic/ceiling Cathedral ceiling Above-grade walls Basement/crawl walls Floors over outside air Floors over unconditioned space Walk-out slab-on-grade Window U-values: Glass door U-values: Solid door U-values: Method of obtaining energy compliance: REScheck Prescriptive Performance Number of each type of furnace and efficiency: 90+ (must run both pipes to exterior) Other: % Number and Type of water heaters: gas electric Standard Direct Vent Instantaneous Crawl Space options: vented or unvented (choose one) Vented crawl spaces have openings in the foundation and receive their ventilation from outdoors; the floor above this area is insulated as are the ducts in the space. The ventilation openings are sized depending upon whether a Class I vapor retarder material is covering the ground. Unvented crawl spaces have the walls insulated, but the ducts don t have to be insulated, and have no openings to the exterior, but receive air by one of two ways: 1. Continuously operated mechanical exhaust with a duct or transfer grille from the conditioned space per the code. 2. Conditioned air supply and return are provided in this area per the code with ducts and openings or transfer grilles.

All unvented crawl spaces shall have the ground covered with a Class I vapor retarder, with joints overlapped 6 and taped or sealed, and it must extend up the crawl space walls 6 and be attached and sealed to the walls. Attic Options: vented or unvented (choose one) vented attics shall have insulation on the attic floor and be ventilated at a rate of 1/150 or 1/300 per code depending upon the location of the ventilation openings; all ducts in this space need to be insulated, both supply and return. unvented attics are completely contained within the building thermal envelope, with the insulation on the underside of the roof; ducts located in this area do not need to be insulated.