July Minimum Fastening Requirements (Fully Adhered)... 5

Similar documents
Transcription:

EPDM POCKET GUIDE

Mule Hide Products EPDM Field Installation Guide Mechanically Fastened and Fully Adhered Systems July 2017 Insulation Attachment Page Minimum Fastening Requirements (Fully Adhered)... 5 Mechanically Attached Sheet Layout Sheet Fastening Guidelines... 6 Perimeter Enhancement Requirements... 8 Perimeter Sheet Layout (MHE-191)... 10 Perimeter Sheet Layout W/RMS (MHE-192)... 11 Buildings with Large Wall Openings (MHT-MA-103A)... 12 Buildings with Overhangs (MHT-MA-103B)... 13 Roof Perimeter Calculation (MHT-UN-108A)... 14 Roof Perimeter Calculation (MHT-UN-108B)... 15 Mechanically Fastened Lap Details 8 Seam-2 Barbed Plates Adhesive (MHE-112)... 16 6 Seam-2 Barbed Plates-6 Tape * (MHE-112A)... 17 6 Seam-A-P 40 Bar-6 Tape * (MHE-112B)... 18 7 Seam-A-P Bar-Adhesive (MHE-113)... 19 7 Seam-A-P Bar-Tape * (MHE-114)... 20 7 Seam-A-P-40 Bar-Tape * (MHE-114A)... 21 Roof Edge Treatment Drip Apron * (MHE-101)... 22 Drip Apron/Gutter (MHE-102)... 23 All Purpose Bar * (MHE-103)... 24 Ballasted Retainer * (MHE-104)... 25 Gravel Stop Snap Lock * (MHE-105)... 26 Gravel Stop * (MHE-106)... 27 Gravel Stop Scupper (MHE-107)... 28 Drip Edge at Mansard (MHE-108)... 29 1-3/4 Metal Fascia System (MHSM-3500)... 30 4 Metal Fascia System (MHSM-3510)... 31 Pre-Manufactured Gravel Stop - EPDM (MHE-3130)... 32 2-Piece Compression Edge - EPDM (MHE-3110A)... 33 2-Piece Compression Edge - EPDM (MHE-3110B)... 34 2-Piece Compression Edge - EPDM (MHE-3110C)... 35 2-Piece Compression Edge Large - EPDM (MHE-3115A)...36 2-Piece Compression Edge Large - EPDM (MHE-3115B)...37 2-Piece Compression Edge Large - EPDM (MHE-3115C)... 38 Flat Coping with Continuous Cleat (MHSM-6050)... 39 Canted Coping with Continuous Cleat (MHSM-6052)... 40 Snap Coping (MHSM -6054A)... 41 Snap Coping (MHSM -6054B)... 42 Arched Coping with Splice Plate (MHSM-6056)... 43 Reglet Counterlashing (MHSM-6130)... 44 1

2-Piece Reglet Counterlashing (MHSM-6145)... 45 Surface Mounted Counterlashing (MHSM-6146)... 46 Gutter Attachment X-Series (MHSM-2091)... 47 Splices/RMS 3 Seam-Adhesive (MHE-110)... 48 3 Seam-3 Tape (MHE-111)... 49 3 Seam-Cover Tape * (MHE-111A)... 50 6 Seam-6 Tape (MHE-111B)... 51 6 Seam-Adhesive (MHE-115)... 52 End Laps and T Joints (MHE-118)... 53 RMS Strip Fastener Layout (MHE-119)... 54 RMS Strip-Tape-Fastener Layout * (MHE-119A)... 55 Parapet/Curb Flashing A-P Bar-Vertical-Adhesive (MHE-120)... 56 A-P Bar-Vertical-3 Tape (MHE-120A)... 57 A-P Bar-Vertical-Cover Tape * (MHE-120B)... 58 A-P Bar-Vertical-6 Tape * (MHE-120C)... 59 2 Barbed Plates-Vertical-Adhesive (MHE-121)... 60 2" Barbed Plates-Vertical-3" Tape (MHE-121A)... 61 2" Barbed Plates-Vertical- cover Tape * (MHE-121B)... 62 2" Barbed Plates-Vertical-6" Tape * (MHE-121C)... 63 A-P Bar-Horizontal-Adhesive (MHE-122)... 64 A-P Bar-Horizontal-3" Tape (MHE-122A)... 65 A-P Bar-Horizontal-Cover Tape * (MHE-122B)... 66 A-P Bar-Horizontal-6" Tape * (MHE-122C)... 67 2 Barbed Plate-Horizontal-Adhesive (MHE-123)... 68 2 Barbed Plate-Horizontal-3" Tape (MHE-123A)... 69 2 Barbed Plate-Horizontal-Cover Tape* (MHE-123B)... 70 2 Barbed Plate-Horizontal-6" Tape* (MHE-123C)... 71 RMS Strip-Vertical - Tape * (MHE-124A)... 72 RMS Strip-Horizontal-Tape * (MHE-125A)... 73 Drains Roof Drain * (MHE-130)... 74 Roof Drain Tapered * (MHE-131)... 75 Roof Drain W/Sump (MHE-132)... 76 Drain Insert (MHE-133)... 77 Through Wall Scupper (MHE-134B)... 78 Through Wall Overlow (MHE-135)... 79 Pipe Flashings Premolded Pipe Boot-MA Tape * (MHE-140A)... 80 Premolded Pipe Boot Tape * (MHE-140C)... 81 Field Fabricated Pipe-Adhesive (MHE-141)... 82 Field Fabricated Hot Pipe-Adhesive (MHE-142)... 83 Field Fabricated Pitch Pan-Adhesive (MHE-143)... 84 Pourable Sealer Pocket * (MHE-144)... 85 2

Expansion Joints Field Joint * (MHE-150)... 86 Existing Field Joint A (MHE-151)... 87 Existing Field Joint B (MHE-152)... 88 Field Joint RMS Strip Tape * (MHE-153B)... 89 Deck to Wall Joint A -RMS -Tape * (MHE-154B)... 90 Deck to Wall Joint B -RMS -Tape * (MHE-155A)... 91 Deck to Wall Joint C -Adhesive * (MHE-156A)... 92 Deck to Wall Joint C -Tape * (MHE-156B)... 93 Curb/Firewall-Adhesive (MHE-157A)... 94 Curb/Firewall-Tape * (MHE-157B)... 95 EPDM Tie-ins EPDM/BUR-Envelope (MHE-160A)... 96 EPDM/BUR-Envelope W/Tape (MHE-160B)... 97 EPDM/BUR (Smooth) (MHE-161A)... 98 EPDM/BUR (Smooth) W/Tape (MHE-161B)... 99 Hot Stripping (MHE-162)... 100 EPDM/Shingles - W/RMS & Tape (MHE-163A)... 101 EPDM/Shingles - A-P Bar (MHE-164)... 102 Vertical Terminations All Purpose Bar (A-P Bar) (MHE-170)... 103 Reglet (MHE-171)... 104 Metal Coping (MHE-172)... 105 Counter Flashing (MHE-173)... 106 Counter Flashing W/A-P Bar * (MHE-174)... 107 Stone Coping * (MHE-175)... 108 Miscellaneous Roof Hatch with Foam Rod (MHE-UN-176)... 109 Roof Hatch with Counterlashing (MHE-UN-177)... 110 Lightning Rod, Vertical (MHE-180)... 111 Lightning Rod, Horizontal MHE-181)... 112 Sleeper (MHE-182)... 113 Outside Corner * (MHE-183)... 114 Inside Corner * (MHE-184)...115 Outside Corner 1 Piece (MHE-186)... 116 Ridge Attachment - RMS (MHE-190)... 117 90-Mil EPDM Details Metal-Era Perma-Tite Edge (MHE-500)... 118 Metal-Era Anchor-Tite Edge (MHE-501)... 119 Drip Edge (MHE-502)... 120 All Purpose Bar at Roof Edge (MHE-503)... 121 Membrane Splice ( T Joint) (MHE-508)... 122 Field Fabricated Pipe Seal (MHE-509)... 123 Flexible Penetration (MHE-510)... 124 Field Fabricated Hot Stack (MHE-511)... 125 3

Premolded Pipe Boot (MHE-512)... 126 Curb Flashing and Outside Corner (MHE-513)... 127 Inside Corner w/ Separate Flashing (MHE-514)... 128 Inside Corner w/ Continuous Flashing (MHE-515)... 129 Outside Corner w/ Uncured Tape (MHE-516)... 130 Pourable Sealer Pocket w/ Hood (MHE-517)... 131 Pourable Sealer Pocket (Double) (MHE-518)... 132 Penetration Curb Detail (MHE-519)... 133 End Lap & T Joint Patches (MHE-520)... 134 Wall Flashing w/ End Lap (MHE-521)... 135 Vertical Flashing Terminations (MHE-522)... 136 Insulation Attachment Patterns/Guidelines Extruded Polystyrene Insulations (MHT-MA-700)... 137 Insulation Attachment Patterns (MHT-MA-701)... 138 Mule-Hide 8 Field Fasteners (MHT-FA-720)... 139 Mule-Hide 12 Field Fasteners (MHT-FA-721)... 140 Mule-Hide 16 Field Fasteners (MHT-FA-722)... 141 Mule-Hide 17 Field Fasteners (MHT-FA-723)... 142 Factory Mutual 8 Field Fasteners (MHT-FM-724)... 143 Factory Mutual 12 Field Fasteners (MHT-FM-725)... 144 Factory Mutual 16 Field Fasteners (MHT-FM-726)... 145 Factory Mutual 17 Field Fasteners (MHT-FM-727)... 146 Helix Foam 4 Bead Spacing (MHHA-UN-4)... 147 Helix Foam 6 Bead Spacing (MHHA-UN-6)... 148 Helix Foam 12 Bead Spacing (MHHA-UN-12)... 149 4

Fully Adhered EPDM Minimum Insulation Fastening Requirements Standard Wind Speed (55 MPH coverage) Insulation Type or Overlay Approved Polyisocyanurate - Min 2" thick (top layer) Approved Polyisocyanurate - Min 1.5" up to 2" thick Approved Polyisocyanurate - Min 1.0" up to 1.5" thick ½ HD Poly-Iso - Installed over Approved Insulation HD Fiberboard - Min 1/2" thick- Installed over Approved Insulation Dens Deck Prime or Securock - Min 1/4" thick - Installed over Approved Insulation OSB - Min 7/16" thick - Installed over Approved Insulation Approved OSB/Polyisocyanurate Composite - Min 2" thick Fasteners per 4' x 8' board Field Perimeter Corner 8 12 16 12 18 24 16 24 32 16 24 32 16 24 32 12 18 24 17 25 32 17 25 32 5

Mechanically Attached EPDM Minimum Membrane Fastening Requirements Standard Wind Speed (55 MPH coverage) Membrane / Adhesive Type / Other (10 or 15 year warranty) 1. 0.045" or 0.060" thick Mule-Hide EPDM Reinforced Black Membranes. 2. Field seams: In-Seam Tape & Primer (6" or two strips of 3") 3. Field seams: Max 10-Year Warranty - Splice Adhesive with Membrane Cleaner/Tape Primer 4. All 'T' joints overlaid with EPDM uncured flashing tape. Membrane / Adhesive Type / Other (20 year warranty) 1. 0.060" thick Mule-Hide EPDM Reinforced Membrane 2. Field seams: 6" In-Seam Tape & Primer 3. RMS and Tape Primer must be used at base of all parapet walls. 4. All 'T' joints overlaid with T-joint covers or EPDM uncured flashing tape. 5. Inside and outside corners: Mule-Hide Pre-Cut Inside/Outside corners Mule-Hide EPDM uncured flashing tape minimum 9 x 9 6

Roof Deck Steel Min 22 gauge Steel Less than 22 gauge 2X Plank ¾ Plywood Roof Height Steel Roof Decks Width of Field Sheet Fastener Spacing Up to 50 10 6 oc Up to 50 Up to 50 5/8 Plywood Up to 50 ½ Plywood 1X Plank Up to 50 OSB Up to 50 2500 psi 2 Min Pour or Precast Wood Roof Decks Structural Concrete Roof Decks 8 12 oc Pull test required Contact Mule-Hide for additional Information 10 6 oc 8 12 oc 10 6 oc 8 12 oc 10 6 oc 8 6 oc Contact Mule-Hide Technical Department prior to starting work Up to 50 10 6 oc 7

Perimeter Enhancement Requirements Mechanically Attached System With 55-MPH Wind Speed Coverage Limitations Contact Mule-Hide for all projects requiring specific Factory Mutual or Building Code compliance such as Florida Product Approval, Texas Department of Insurance, etc. Building Height For buildings 100 ft. or less in height, located in urban, rural or suburban exposure areas. Not applicable for coastal or high wind areas. Maximum design wind speed of 100-MPH. Minimum Perimeter 0-34 ft 1 Perimeter sheet (1)(2) 1 Perimeter enhancement width (3) 35 100 ft 2 Perimeter sheets (1)(2) (wind zones up to 100 mph) Higher than 100 ft. or higher wind zones. Projects in exposure D category (coastal areas) Roof edges along interior walls or roof edges with 8 ft. or higher walls. (Walls extend above the roof level) 2 Perimeter Enhancement Widths (2) (wind zones up to 100 mph) Contact Mule-Hide Tech. Dept. Contact Mule-Hide Tech. Dept. No perimeter enhancement required 8

FM Approval For buildings where FM approved securement is required and for buildings that do not meet the Limitations stated above. Install perimeter enhancements throughout the corner/perimeter areas of the roof. The width of these areas is determined by the lesser of the following two calculations: a. 0.1 x the building width = or b. 0.4 x the building height = In no event shall the perimeter/corners be less than 4ft. Notes: 1. When using Mule-Hide standard sheet widths: 8 wide field sheets use 9 RMS no less than 4 no larger than 4 9 10 wide field sheets use 9 RMS no less than 5 no more than 6 2. If the contractor elects to cut perimeter sheets from scrap membrane, the perimeter sheet dimension MUST be as follows: 8 wide field sheet no less than 4 wide to no larger than 4-9 wide perimeter sheet 10 wide field sheet no less than 5 wide to no more than 6 wide perimeter sheet c. 3. Perimeter enhancement widths are used when the 10 RUSS and/or plates/ fasteners through the membrane methods are utilized for perimeters. 9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

121

122

123

124

125

126

127

128

129

130

131

132

133

134

135

136

137

138

139

140

141

142

143

144

145

146

147

148

149

NOTES: 150

NOTES: 151

NOTES: 152

National Support Center 1195 Prince Hall Drive Beloit, WI 53511 2017 Printed in USA MH LIT# SP.PGEPDM Rev. 0 8/17