The consists of aesthetically pleasing, pre-finished connectors and innovative concealed joist ties designed for exposed wood applications. These connectors provide structural performance and, at the same time, add a unique appearance feature to a project. Refer to Simpson Strong-Tie C-APG catalog. ARCHITECTURAL FINISHES Eliminate time consuming prep work and costly field painting. Available finishes include textured flat black powder-coat, gray paint and hot-dip galvanized coating. AVAILABILITY Select products are in stock and readily available. Contact Simpson Strong-Tie for product availability and lead times for non-stocked items. PRE-ENGINEERED AND TESTED Load-rated products are verified to perform to design loads, unlike custom designed and fabricated connectors. QUALITY ASSURANCE No-Equal quality-controlled manufacturing ensures product consistency and high quality. Products shown in this section come with textured flat black powder-coat unless otherwise noted. Most are also available with a galvanized coating or gray primer. Contact Simpson Strong-Tie for availability. www.strongtie.com/apg BP BEARING PLATES Bearing Plates give greater bearing surface than standard cut washers, and help distribute the load at these critical connections. MATERIAL: See table FINISH: Textured flat black powder-coat INSTALLATION: See General Notes. CODES: See page 13 for Reference Key Chart. Thickness Dimensions W L Bolt Dia. BP 1 2PC 3 16 2 2 1 2 BP 5-2PC 3 16 2 2 5 BP 5 PC 1 2 1 2 2 1 2 5 BP 3 PC 5 16 2 3 3 BP 7 PC 5 16 3 3 7 BP1PC 3 3 1 2 3 1 2 1 210 SPECIAL ORDER PLATES 190 Simpson Strong-Tie can make a variety of flat and bent steel shapes, which include gusset plates for heavy timber trusses, custom ornamental shapes and retaining plates. MATERIAL: 3 gauge maximum FINISH: lvanized, textured powder-coated flat black, Simpson Strong-Tie gray paint, stainless steel. Contact Simpson Strong-Tie for availability. TO OBTAIN A QUOTE: with plate dimensions, hole diameter and locations, steel thickness, desired finish (Simpson Strong-Tie Gray Paint, Black Powder-Coat, HDG or raw steel). of 48"x48" (approx. 1 16" tolerance). engineering or load values for Special Order Plates. additional information. BP W and H indicate the envelope size of the steel shape. BP (Plate shown has black powder-coat)

CONCEALED JOIST TIES The CJT is a concealed connector. It can be installed three ways: with no routing of header/post or beam; a routed header/post, or a routed beam. MATERIAL: 12 gauge FINISH: lvanized INSTALLATION: See General Notes. required. Screws require a hex head driver. full table loads. short pins, center in beam. (e.g. CJT3L) (see footnote #1 below). OPTIONS: See technical bulletin T-CJT (see page 230 for details). CODES: See page 13 for Reference Key Chart. CJT5 (Others similar) 2³ ₄" Short pin 4³ ₄" Long pin Chamfered Steel Pin (lvanized) ¹ ₂" Dia. WARNING: This connector requires special attention to ensure correct installation. The beam must be installed perpendicular to the support member. The connection s components may be damaged if the beam is rotated from its opposite end during or after installation. Damaged components may not be noticeable and may reduce the connector s load carrying capacity. Joist Size Dimensions Fasteners Allowable Loads H 1 H 2 SDS Pins (2 3 " or 4 3 ") 2 Uplift (160) Floor (100) Snow (115) Roof (125) DOUGLAS FIR CJT3 4x6 5 9 16 4 7 16 6 3 985 1050 1050 1050 4x8 5 9 16 4 7 16 6 3 1655 1050 1050 1050 CJT4 4x10 7 5 15 16 8 4 2460 2440 2805 2815 CJT5 4x12 8 9 16 7 7 16 10 5 3255 3005 3455 3755 CJT6 4x12 10 8 15 16 12 6 4005 3535 3990 3990 GLULAM BEAM CJT3 3 1 x7 1 2 5 9 16 4 7 16 6 3 1655 1240 1240 1240 CJT4 3 1 x9 7 5 15 16 8 4 2460 2440 2805 2900 CJT5 3 1 x10 1 2 8 9 16 7 7 16 10 5 3255 3005 3455 3755 CJT6 3 1 x12 10 8 15 16 12 6 4005 3535 4065 4420 PSL CJT3 3 1 2x9 1 2 5 9 16 4 7 16 6 3 1655 1840 2115 2160 CJT4 3 1 2x9 1 2 7 5 15 16 8 4 2460 2145 2145 2145 CJT5 3 1 2x9 1 2 8 9 16 7 7 16 10 5 3255 3005 3455 3755 CJT6 3 1 2x11 7 10 8 15 16 12 6 4005 3535 4065 4420 1. Center pin in beam. Short pin (2 3 ") for use with 3 1 GLB, 4x sawn lumber or 3 1 2" wide PSL. Long pin (4 3 ") for use with 5 1 GLB, 6x sawn lumber or greater widths. 2. See technical bulletin T-CJT for additional load information with long pins (see page 230 for details). ORNAMENTAL JOIST HANGER The OHU Ornamental Joist Hangers are heavy duty, load-rated joist hangers that are attached with Simpson Strong-Tie Strong-Drive 1 "x3" double-barrier coating SDS wood screws (supplied with product). MATERIAL: 12 gauge FINISH: Textured powder-coated flat black paint. OPTIONS: No modifications. CODES: See page 13 for Reference Key Chart. CJT (Note that pins should be centered within beam) 1. Allowable uplift loads have been increased 60% for wind or earthquake loading OHU SDS 1 "x3" U.S. Patent 6,109,850 5,897,280 OHU Dimensions of SDS 1 "x3" DF/SP SPF/HF Joist Wood Screws Size Uplift Floor Snow Roof Uplift Floor Snow Roof W H B Face Joist (160) (100) (115) (125) (160) (100) (115) (125) OHU46-SDS3 4x6 12 3 9 16 5 4 6 4 1930 2520 2900 3150 1390 1800 2070 2250 OHU48-SDS3 4x8 12 3 9 16 6 3 4 8 6 2765 3360 3865 4200 1990 2400 2760 3000 OHU410-SDS3 4x10 12 3 9 16 8 3 4 12 6 2765 5040 5795 6300 1990 3600 4140 4500 OHU412-SDS3 4x12 12 3 9 16 10 3 4 12 8 3565 5040 5795 6300 2570 3600 4140 4500 OHU414-SDS3 4x14 12 3 9 16 12 3 4 14 10 3565 5880 6760 7350 2570 4200 4830 5250 OHU66-SDS3 6x6 12 5 1 2 5 4 6 4 1930 2520 2900 3150 1390 1800 2070 2250 OHU68-SDS3 6x8 12 5 1 2 7 4 12 6 2765 5040 5795 5955 1990 3600 4140 4290 OHU610-SDS3 6x10 12 5 1 2 9 4 14 6 2765 5880 6760 6885 1990 4200 4830 4960 OHU612-SDS3 6x12 12 5 1 2 11 4 16 8 3565 6720 7730 7815 2570 4800 5520 5630 OHU614-SDS3 6x14 12 5 1 2 13 4 18 10 3565 7560 8695 8745 2570 5400 6210 6300 211

CLASSIC COLLECTION MATERIAL: As noted in tables FINISH: Textured powder-coated flat black paint INSTALLATION See General Notes. CODES: See page 13 for Reference Key Chart. STRAP TIES Dimensions Allowable Tension Loads 1,2 W L Qty Dia (160) HST2PC 7 2 1 2 21 1 6 5 5220 HST5PC 7 5 21 1 12 5 10650 HST3PC 3 3 25 1 2 6 3 7625 HST6PC 3 6 25 1 2 12 3 15360 PS218PC 7 2 18 4 3 4990 PS418PC 7 4 18 4 3 5030 PS720PC 7 6 3 20 8 1 2 4685 I4, L3, F2 2. Allowable loads are based on parallel-to-grain loading and a minimum member thickness of 3 1 2" with machine bolts in single shear. Straps must be centered about splice joint and bolt edge distances must meet NDS minimum requirements. 3. Designer must determine allowable loads when combining bolts parallel and perpendicular to grain. BEAM TO COLUMN TIES 180 HSTPC PSPC L CBPC CCPC 1212HLPC (1616HLPC similar) 1212HTPC (1616HTPC similar) 212 COLUMN BASES 2. See page 60 for glulam beam sizes. Add PC to the model, i.e. CB5-6PC. 3. Minimum side cover for full loads is 3" for CB s. 4. Install with bottom of base flush with concrete. 5. Post bases do not provide adequate resistance to prevent members from rotating about the base and therefore are not recommended for non top-supported installations (such as fences or unbraced carports). BEAM HANGERS MATERIAL: Top flange 7 ga, Stirrups 7 ga. Minimum Bolt Dimensions End & Edge Distances Dimensions Allowable Tension Loads W 1 W 2 Qty Dia (160) CB44PC 7 3 9 16 3 1 2 2 5 CB46PC 7 3 9 16 5 1 2 2 5 CB48PC 7 3 9 16 7 1 2 2 5 CB66PC 7 5 1 2 5 1 2 2 5 CB68PC 7 5 1 2 7 1 2 2 5 CB88PC 3 7 1 2 7 1 2 2 3 CB810PC 3 7 1 2 9 1 2 2 3 IL8 COLUMN CAPS Dimensions Allowable Loads H Header Allowable Loads 1,2 Tension/Uplift F 1 W H L d 1 d 2 Qty Dia (100/160) (100/160) 1212HLPC 7 2 1 2 12 12 2 1 2 4 3 5 5 1616HLPC 7 2 1 2 16 16 2 1 2 4 3 5 5 1212HTPC 7 2 1 2 12 12 2 1 2 4 3 6 5 1616HTPC 7 2 1 2 16 16 2 1 2 4 3 6 5 1. 1212HL, 1616HL, 1212HT and 1616HT are to be installed in pairs with machine bolts in double shear. A single part with machine bolts in single shear is not load-rated. 2. Allowable loads are based on a minimum member thickness of 3 1 2". 3. 1212HT, 1616HT loads assume a continuous beam. Joist MEGPC without Top Flange LEGPC/ MEGPC Allowable Loads Dimensions Beam Post Uplift Down W 1 W 2 L H Qty Dia Qty Dia (160) (100) CC44PC 7 3 5 3 5 7 4 2 5 1465 15310 CC46PC 7 3 5 5 1 2 11 6 1 2 4 5 2800 24060 CC66PC 7 5 1 2 5 1 2 11 6 1 2 4 5 4040 30250 CC68PC 7 5 1 2 7 1 2 11 6 1 2 4 5 4040 37810 CC88PC 3 7 1 2 7 1 2 13 8 4 3 7440 54600 with no further increase allowed; reduce where other loads govern. 2. Post sides are assumed to lie in the same vertical plane as the beam sides. 3. Downloads are determined using F'c perpendicular equal to 625 psi on seat area; reduce where end bearing value of post, L/R of post, or other criteria are limiting. 4. See pages 64 for glulam beam sizes and end conditions. Add PC to the model, i.e. CC3 1-4PC. 5. Column caps for end conditions available to order, add an E to the start of the model number. See page 64 for load values. Without Top Flange No Triangle Theory Triangle Theory W TF Qty Dia Qty Dia (100) (125) (100) (125) (100) (125) LEG3PC 3 1 9 2 1 2 4 3 3465 4330 12675 13215 11865 12730 LEG5PC 5 1 9 2 1 2 4 3 3465 4330 16290 16290 11865 12730 MEG5PC 5 1 9 2 1 2 6 3 5 6460 19710 19710 13570 14865 LEG7PC 6 7 9 2 1 2 4 3 3465 4330 16290 16290 11865 12730 MEG7PC 6 7 9 2 1 2 6 3 5 6460 19710 19710 13570 14865 I19, L14, F18 I12, L4, F11 1. Allowable loads assume a 5 1 2" carrying member. 2. Specify desired height, minimum height listed in the table. 3. Glulam widths listed in table. To specify other widths add an X to the name and specify. 4. See Glulam Connectors section of this catalog for additional information on these products. 5. Refer to page 94 footnote #4 For triangle theory explanation.

RUSTIC COLLECTION MATERIAL: As noted in tables FINISH: Textured powder-coated flat black paint INSTALLATION: CODES: See page 13 for Reference Key Chart. STRAP TIES Dimensions Allowable Loads 1,2 Tension/Uplift W L Qty Dia (160) OS 12 2 12 4 1 2 1565 OHS 7 2 1 2 12 4 5 2015 OHS135 7 6 13 1 2 4 3 5045 OHS195 7 6 19 1 2 8 3 10085 OT/OHT 2. Allowable loads are based on parallel-to-grain loading and a minimum member thickness of 3 1 2" with machine bolts in single shear. Straps must be centered about splice joint and bolt edge distances must meet NDS minimum requirements. 3. Designer must determine allowable loads when combining bolts parallel and perpendicular to grain. OHS135 OHS195 OL/OHL BEAM TO COLUMN TIES Minimum Bolt Dimensions End & Edge Distances Allowable Loads 1,2,3 Tension/Uplift F 1 W H L d 1 d 2 Qty Dia (100/160) (100/160) OL 12 2 12 12 2 3 1 2 5 1 2 1435 565 OHL 7 2 1 2 12 12 2 1 2 4 3 5 5 OT 12 2 12 12 2 3 1 2 6 1 2 2585 815 OHT 7 2 1 2 12 12 2 1 2 4 3 6 5 OS OHS OU (7 ga) 1. OL, OHL, OT and OHT must be installed in pairs with machine bolts in double shear. A single part with machine bolts in single shear is not load-rated. 2. Allowable loads are based on a minimum member thickness of 3 1 2". 3. OT, OHT loads assume a continuous beam. HEAVY ANGLES Dimensions W L Qty Dia OHA33 7 3 1 3 2 3 OHA36 7 3 1 6 4 3 180 OHA COLUMN BASES Dimensions Allowable Uplift Loads W 1 W 2 Qty Dia (160) OCB44 3 3 9 16 3 1 2 2 5 OCB46 3 3 9 16 5 1 2 2 5 OCB48 3 3 9 16 7 1 2 2 5 OCB66 3 5 1 2 5 1 2 2 5 OCB68 3 5 1 2 7 1 2 2 5 OCB88 3 7 1 2 7 1 2 2 3 OCB810 3 7 1 2 9 1 2 2 3 COLUMN CAPS Allowable Loads Dimensions Beam Post Uplift Down W 1 W 2 L H Qty Dia Qty Dia (160) (100) OCC44 3 3 5 3 5 9 4 1 2 2 5 1465 15310 OCC46 3 3 5 5 1 2 12 7 1 2 4 5 2800 24060 OCC66 3 5 1 2 5 1 2 12 7 1 2 4 5 4040 30250 OCC68 3 5 1 2 7 1 2 12 7 1 2 4 5 4040 37810 OCC88 3 7 1 2 7 1 2 15 7 1 2 4 3 7440 54600 1. Allowable loads have been increased 60% for wind or earthquake loading with no further increase allowed; reduce where other loads govern. 2. Minimum side cover for full loads is 3" for CB s. 3. Install with bottom of base flush with concrete. 4. Post bases do not provide adequate resistance to prevent members from rotating about the base and therefore are not recommended for non top-supported installations (such as fences or unbraced carports). 1. Allowable uplift loads have been increased 60% for wind or earthquake loading 2. Downloads are determined by nominal sawn beam allowable bearing at 625 psi on seat area; reduce where shear value of beam, end bearing value of post, L/R of post, or other criteria are limiting. 3. Post sides are assumed to lie in the same vertical plane as the beam sides. 4. For end conditions specify OECC. JOIST HANGERS OCC (3 ga) OCB (3 ga) Dimensions Allowable Loads 1,2 Uplift Floor Roof W H Header Joist 2 (160) (100) (125) OU46 7 3 9 16 5 2-3 1-3 685 1270 1590 OU48 7 3 9 16 7 4-3 2-3 1365 2545 3175 OU410 7 3 9 16 9 4-3 2-3 1365 2545 3175 OU412 7 3 9 16 11 6-3 3-3 2050 3815 4765 OU414 7 3 9 16 13 6-3 3-3 2050 3815 4765 OU68 7 5 1 2 7 4-3 2-3 1365 2545 3175 OU610 7 5 1 2 9 4-3 2-3 1365 2545 3175 OU612 7 5 1 2 11 6-3 3-3 2050 3815 4765 OU614 7 5 1 2 13 6-3 3-3 2050 3815 4765 OU810 7 7 1 2 9 4-3 2-3 1365 2545 3175 OU812 7 7 1 2 11 6-3 3-3 2050 3815 4765 OU814 7 7 1 2 13 6-3 3-3 2050 3815 4765 1. Load values allowed assume a carrying member of not less than 3 1 2". 2. Roof loads are 125% of floor loads unless a limited by other criteria. Floor loads may be adjusted for other load durations according to the code provided they do not exceed those in the roof column. 3. Additional glulam beam widths are available. Add an X to the name and specify width, i.e. OU68X, W = 5.25. 4. Skew and slope options not available. 213

STANDOFF BASES The PBV is a hidden standoff post base. Two different sizes fit a variety of posts shapes. MATERIAL: 14 gauge galvanized steel FINISH: Textured powder-coated flat black paint or galvanized ORDER: For powder-coated flat black, order PBV6PC or PBV10PC. For galvanized coating, order PBV6 or PBV10. For kit containing Simpson Strong-Tie Strong-Drive screws (SDS), RFB bolt, SET 1.7 adhesive, and powder-coated PBV, order PBV6KT or PBV10KT. The CPS is a Composite Plastic Standoff designed for increased concrete surface area. MATERIAL: Engineered composite plastic INSTALLATION: PBV and CPS Post: 3 " diameter hole, 10" into the center of the post. SET Epoxy-Tie adhesive. uses four Simpson Strong-Tie SDS screws. Concrete: 3 " diameter hole per anchor design (see footnote 2 below). Epoxy-Tie adhesive. Insert post subassembly into hole and allow epoxy to set and cure. Post bases do not provide adequate resistance to prevent members from rotating about the base and therefore are not recommended for non top-supported installations (such as fences or unbraced carports). CODES: See page 13 for Reference Key Chart. 2⁹ ₁₆" PBVPC CPS 4 X 6 SIMPSON STRONG-TIE STRONG-TIE COMPOSITES Engineered for No-Equal Performances CPS46 PBV6PC Diameter 10d Nail 10" CPS4 (other sizes similar except CPS46) CPS4 Post or Column Size Dimensions Fasteners Allowable Loads L W H Post Anchor Bolt Uplift Down 3 CPS4 4x4 3 1 3 1 1 4-10d 5 " 4490 5195 CPS46 4x6 5 5 16 3 5 16 1 4-10d 2-5 " 4490 5865 CPS5 5x5 4 1 4 1 1 4-10d 5 " 4490 5865 CPS6 6x6 5 5 16 5 5 16 1 4-10d 5 " 4490 7745 CPS7 8x8 7 1 7 1 1 1 4-10d 5 " 4490 8315 PBV6PC 6" Dia 5 1 1 4-SDS 1 x3 5 " 3800 9250 PBV10PC 10" Dia 9 3 16 1 4-SDS 1 x3 5 " 3800 19225 F1 1. Allowable uplift load capacities are for solid sawn posts with specific gravity of 0.36 minimum except the PBV, which is based on round Viga (Ponderosa Pine) wood posts. 2. All allowable uplift loads are based on a lowest ultimate load from testing divided by a reduction factor of 4. Concrete anchorage to be designed by others, refer to Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry catalog (form C-SAS, see page 228 for details). Allowable uplift capacities shall not exceed those shown in the table. 3. Download capacities are calculated based on the standoff bearing area and a concrete strength of 2500 psi except the PBV, which is based on the wood bearing strength (700 psi for Ponderosa Pine). 4. Allowable loads may not be increased for short term loading. 5. NAILS: 10d = 0.148" dia. x 3" long. See page 22-23 for other nail sizes and information. 214 HL HEAVY ANGLES & GUSSETS Versatile angle gussets and heavy angles promote standardization and construction economy, and are compatible with Simpson Strong-Tie structural hardware. FINISH: Textured powder-coated flat black paint, Simpson Strong-Tie gray paint and also available galvanized TO ORDER: All products with PC suffix are textured powdercoated flat black paint. 7 gauge products without the PC suffix are galvanized. 3 gauge products without the PC suffix are Simpson Strong-Tie gray paint. OPTIONS: Gussets may be added to HL models when L 5". Specify G after numbers in model number as in HL46GPC. CODES: See page 13 for Reference Key Chart. HL55PC Optional Gusset Uplift HL55PC Dimensions (Total) Allowable Loads W 1 & W 2 L D 1 D 2 D 3 D 4 Qty Dia Uplift F 1 HL33PC 7 3 1 2 1 2 1 1 2 2 1 HL35PC 7 3 1 5 1 1 2 1 2 2 4 1 HL37PC 7 3 1 7 1 2 1 1 2 1 2 2 6 1 HL53PC 7 5 3 2 1 2 1 1 2 2 1 2 4 1 HL55PC 7 5 3 5 1 1 2 1 2 2 2 1 2 8 1 HL57PC 7 5 3 7 1 2 1 1 2 1 2 2 2 1 2 12 1 HL43PC 3 4 1 3 1 1 2 2 3 2 3 1555 1580 HL46PC 3 4 1 6 1 1 2 3 2 3 4 3 1555 2025 HL49PC 3 4 1 9 1 1 2 3 2 3 6 3 1555 2025 HL73PC 3 7 1 3 1 1 2 2 3 3 4 3 1555 2025 HL76PC 3 7 1 6 1 1 2 3 2 3 3 8 3 2115 3800 HL79PC 3 7 1 9 1 1 2 3 2 3 3 12 3 2115 3800 HL53PC 1. Allowable loads have been increased 60% for wind or earthquake loading with no further increase allowed; reduce where other loads govern. 2. Use 0.85 times table load for Hem Fir. 3. Parts should be centered on the face of the member to which they are attached. 4. Wood members for the 3 and 5 series must have a minimum width and thickness of 3 1 2" for table loads to apply. 5. Wood members for the 4 and 7 series must have a minimum width and thickness of 5 1 " for table loads to apply. 6. Parts must be used in pairs. Lag bolts of equal diameter (minimum 5" long) may be substituted for machine bolts into beam with no reduction in load.