VISUM3. One tile creates the visual effect of three

Similar documents
Transcription:

VISUM

VISUM3 One tile creates the visual effect of three The innovative design allows lower installation costs and achieves with one tile a triple tile look EN 539-2 Test of frost resistance EN 539-1 Impermeability test EN 538 Flexural strength test EN 1024 Geometric characteristics BROWN IDELLA GREY Application VISUM3 Standard Requirements roof tile Flexural Strength test Water Impermeability Frost Resistance EN 538 Resistance > 1200N Above EN 539-1 Complies with level 1 Above EN 539-2 Complies 150 cycles Above Geometric EN 1024 Flatness 1,5% Complies Characteristics Straightness 1,5% Complies Visum3 roof tile complies with the European standard for clay roof tiles EN-1304.

Cost reduction Its large format (11.5 pcs/m 2 ) and packaging on pallets of 210 and 280 units, reduces installation cost Double interlocking The double interlocking -horizontal and vertical- allows the roof to be more watertight, ensuring its impermeability Wide range of colors Its triple exclusive decoration system offers a broader range in tones and hues, so no two tiles are alike 3 in 1 tile Visum3 is a patented interlocking tile with an innovative triple cambered design that gives the appearance of three plain tiles OLD ENGLAND RUSSET VERMONT GREY SLATE The names of the colours shown in the photos, only represent the finishes of the models identified as Visum3 roof tile

LAID METHOD Visum3 roof tile is laid on a discontinuous frame or battens, which will be fixed by building a batten counter batten deck or by fixing them directly to the frame. The laying of Visum3 roof tile is carried out by broken bond (also referred as cross bond) as follows: 1. The Starter course will begin with a Half Visum3 Tile (Q95). 2. Then continue with full tiles Visum3 all the course. 3. The second course will start with a full tile and it will be laid to provide the proper vertical exposure. This exposure is continued through each successive course. Finally we will use the Pyramid Ridge Tile (Q91) to lay all the Side-courses. See Figure for sequence of installation. 7 5 3 4 2 1 8 6 INSTALLATION DETAILS RIDGE -Ridge tiles must be installed lap facing away from the prevailing winds, in order to assure water tightness. -Field tiles at top course should be secured directly either into the deck or top batten with stain-less ring screw nails or similar. -All ridges and hips shall be covered with self adhesive Alu-Roll, La Escandella Aluminum roll for hip and ridges (AM01), or similar approved breathable waterproof underlayment. Underlayment should be secured over the ridge nailer with non-corrosive roofing nails. -Apply ridge tiles with a minimum overlapping of 5 cm (2 ) through-out the ridgeline facing away from the prevailing wind-driven rain. HIP -Hip tiles must be installed in the same way as in the ridge. -Field tiles must be mitter cut parallel to the hip line and secured. -All ridges and hips shall be covered with self adhesive Alu-Roll, La Escandella Aluminum roll for hip and ridges (AM01), or similar approved breathable waterproof underlayment. -Air should be able to flow through the ridge and hip area. Be sure not to close these off with mortar or similar. Closing them off could result in cracks, peeling off,.. in freezing and thawing cycles. VALLEY -Both Valley and eave line channel are particularly vulnerable to water migration and leakage. Valleys should have a clear and unobstructed pathway for quick water drainage. -Install valley battens on each side of the valley crease. Allu Valley Tape (AM18), or similar approved adhered waterproof valley underlayment, shall be laid vertically up all valleys in addition to other required underlayment that should be fixed by using glue, resin or similar. -Where valley intersects with ridge line, apply Allu Valley Tape (AM18), or similar approved underlay-ment, which should be covered by the ridge tile. Valley should be extended along the eaves to overhang the fascia board by 5cm (2 ) or over the gutter. -Tiles should be laid parallel to the valley line, at same relative angle and should overhang the valley battens by at least 10 cm (4 ). -Tiles at each side of the valley crease should be laid to provide a minimum 15 cm (6 ) width gap (tiles should held back minimum 7.5 cm (3 ) from the center of the valley each way). -Valley tiles must be secured. -Proper Valley flashing instal-lation is required to ensure water tightness in order to avoid cracks, peeling off,

SLOPES / PITCHES The minimum pitch standard recommendations should always be followed (see values in the referral table). On all pitches below the standard recommended minimums, or in regions where ice dams may occur, a waterproof underlayment on the entire deck MUST be applied. Most problems with water-shedding roof installations occur from water that migrates through the joints of the tiles through capillary action, wind-driven rain, and runoff or ice damming. Because of this possibility, the underlayment is critical to the success of the roof. PROTECTED LOCATIONS: hollow area which is surrounded by hills that protect the hollow from the winds in all directions. NORMAL LOCATIONS: Flat area, plateau with minimal elevation changes. EXPOSED LOCATIONS: Places open to strong winds, coastal areas (up to 5 km / 3 miles from the shoreline ), islands or narrow peninsulas, estuaries or closed bays, narrow valleys, isolated mountains, mountain passes and earthquake zones. Hip Hip Hip < 6,5m 6,5m - 9,5m 9,5m - 12m < 21.32 21.32-31.16 31.16-39.37 50% / 26,5º 50% / 26,5º 55% / 29º 50% / 26,5º 55% / 29º 65% / 33º 65% / 33º 75% / 37º 85% / 40,5º Note: For hips greater than 12m (39.4 ) long, a waterproof underlayment on the entire roof deck MUST be applied. FASTENING METHODS The manner in which roof tiles are installed makes them a highly effective water shedding assembly that affords years of service and protection. The effectiveness of a tile roof system as a weather resistant assembly however depends on the proper installation of all the tile roof components, and installing them properly is critical to the performance of the installed system. A 60º - 173% B C 45º - 100% D 38º - 80% 14º - 25% E 0º - 0% A: Every tile should be securely fastened (Nailed, screwed, clipped...) (60º / 203/4:12). B: As a minimum, each tile in every five proportion, should be secured with (10 gauge) non-corrosive ring shank nails or screws (45º / 12:12). C: Each tile hangs on the batten (held by the nib) (38º / 10:12). D: Each tile hangs on the batten, held by the nib. When mortar is used, back bed and face point with color matched mortar. Clean off all excess mortar from the face of the tiles. For Foam Adhesive, refer to local building codes. E: La Escandella recommended minimum slope requirements is 30% (4:12). VENTILATION Ventilation is one of key elements to assure a good hygrothermal behavior of the roof and preservation of the roof structure. The key to a good and well preserved roof is a good ventilated roof. Proper installation of Ventilation tiles combined with ventilated roof can result in energy savings, in a more energy efficient home. Air should be able to flow through the eave and ridge; be sure not to close these off with cement, mortar or similar. Eave and ridge areas should be protected to help minimize the access of birds and vermin infiltration. A free flowing ventilation area must be provided through the roof deck. This ventilation should be evenly distributed throughout the roof space to eliminate any dead air space. La Escandella recommends a minimum of 1 Visum3 ventilation tile (Q96) for every 7 m 2 (1.32 vent tiles per 100 sq ft.) and with a minimum of 2 ventilation tiles per roof surface, installed on the upper part of the roof. Using a proper ventilation system is the best way to avoid moisture in a roof, that could cause peeling, cracking and other defects on the tile. 30 mm 1.8 (minimum) Underlayment Battens Airflow Openings at the eaves and the ridge must allow for even distribution of ventilating air below the entire roof deck. Eaves ventilation comb Rafter 7 8 1 6 4 1 2 2 3 3 9 5 NON-VENTILATED ROOF 6 7 8 VENTILATED ROOF 9 1. Roof tile 2. Micro-ventilation void 3. Ventilation roof tile 4. Rafter 5. Attic 6. Heat insulation underlayment 7. Waterproof underlayment material 8. Frame 9. Eaves ventilation comb / bird stop Note 1: Recommended underlayment installed over the sheathing are dependant on the roof pitch and local weather conditions. Note 2: Underlayment materials must be covered with tile as soon as possible to prevent degradation from exposure. La Escandella warranty will be honored when installation is in strict accordance with local building codes, particularly to those referring to the ventilation of the deck and minimum slope requirements. Clay roof tiles should always be installed in full compliance with the local building codes and good tiling practice. For each country, please refer to local building codes.

VISUM3 Dimensions a: 480 mm; b: 280 mm; c: 35 mm a: 18.9 ; b: 11 ; c: 1.38 Pieces per m 2 - sq. 11.5-106.7 Weight piece 3,850 gr / 8.49 lbs Longitudinal fit 187 mm (± 7 mm) / 7.36 (±0.27 ) b c a Transversal fit 438 mm (± 1 mm) / 17.24 (± 0.04 ) Units per pallet 210 / 280 Laying method Broken bond The Tile dimensions indicated in this chart, allow a tolerance of approximately 2%. Theoretic value: this should be re-calculated on site with the tiles that are to be used. ACCESSORIES La Escandella offers a complete line of Visum3 roof tile accessories, available in any standard color, to customize your roof. Visum3 half roof tile Q95 2300 gr 5.07 lbs 280mm 11.02 247mm 9.72 Round ridge / Hip Round ridge end / Hip starter Q02 3400 gr 7.5 lbs 2.5 uds/ml 75mm 2.95 220mm 8.66 465mm 18.30 Q04 3600 gr 7.94 lbs 470mm 18.5 Round 3 way ridge Round 4 way ridge Q44 Q45 4600 gr 10.14 lbs 4100 gr 9.04 lbs Ø 440mm 17.32 Ø 445mm 17.52 Round 3 way ridge female Q55 End cap round ridge Q83 305mm 12 4100 gr 9.04 lbs 56mm 2.2 223mm 8.78 442mm 17.40 400mm /15.75 2600 gr 5.73 lbs 335mm 13.19 80mm 3.15 Pyramid ridge-side course / Rake Pyramid end ridge Q91 Q93 464mm 18.27 4500 gr 9.92 lbs 2.5 uds/ml 240mm 9.45 465mm 18.30 120mm / 4.72 3500 gr 7.71 lbs With Q91 325mm 12.79 On their products, La Escandella has right to make changes in dimensions, fittings, weight & units per pallet, without previous notice. For more information, please contact your Sales Representative or our Customer Care Service.

d c + 20 mm + 3 /4 a b c a = 60 mm / 2.36 b = 195 mm / 7.67 c = 187 mm (± 7 mm) 7.36 (±0.27 ) d = 0-20 mm / 0-3 /4 (Depending on the slope) First course batten should be 20 mm ( 3 / 4 ) higher than all succeding course battens to provide a vertical alignment and to assure a symmetrical installation 10 mm 218 mm 437-439 mm 437-439 mm 8.58 17.20-17.28 17.20-17.28 10 mm 0.4 168 mm 168 mm 0.4 6.6 6.6 Visum3 tile Q95 Visum3 Half roof tile Q91 Pyramid ridge-side course / rake Pyramid triple ridge Pyramid end cap Q94 443mm 17.44 1. 474mm 18.66 Q92 340mm 13.38 5400 gr 202mm 11.9 lbs 2. 1. 7.95 2900 gr 6.39 lbs 324mm 12.75 With Q91 465mm 18.30 2. 253mm 9.96 With Q91 101mm 3.98 Visum3 bonnet hip Visum3 end bonnet hip Q105 145mm 5.7 Q106 146mm 5.75 2300 gr 5.07 lbs 5 uds/ml 350mm 13.78 211mm 78.3 2400 gr 5.3 lbs 415mm 16.34 202mm 7.95 Ática Ridge 120º Atica collar ridge Q90 3600 gr 7.93 lbs 2.5 uds/ml 201mm 9.91 463mm 18.22 273mm 10.75 Q110 3500 gr 7.71 lbs 90mm 13.54 460mm 18.11 268mm 10.55 Atica end ridge 120º Atica 3 ways Ridge 120º Q109 2900 gr 6.4 lbs 440mm 17.32 200mm 7.87 Q111 5100 gr 11.24 lbs 470mm 18.5 480mm 18.9 With Q90 261mm 10.27 290mm / 11.42 With Q90 280mm 11 Visum3 ventilation roof tile Visum3 chimney roof tile / Pipe tile Q96 4200 gr 9.26 lbs 280mm 11.02 470mm 18.5 Q97 4700 gr 10.36 lbs 280mm 11.02 121mm / 4.76 262mm 10.31 470mm 18.5

EN Ctra. Novelda, km. 2,5 03698 AGOST (Alicante) SPAIN Tel. +34 965 691 788 Fax +34 965 691 692 e-mail: laescandella@laescandella.com Colour Shall be Harmonized but clay tiles are a natural product and some shade variations between individual pieces enhance their beauty and should be expected. All Tiles should be blended regardless of the number of colours supplied. Colours of the tiles shown in this catalogue can not faithfully reflect the colours of the ceramic tiles. On their products, La Escandella has right to make changes in dimensions, fittings, weight & units per pallet, without previous notice. For more information, please contact your Sales Representative or our Customer Care Service. This catalogue, printed in July 2015, replaces the existing ones.