SEISMIC BEHAVIOR OF FOUR-CIDH PILE SUPPORTED FOUNDATIONS

Similar documents
SEISMIC PERFORMANCE AND RETROFIT OF BRIDGE FOOTINGS. David I. McLean 1

EXPERIMENTAL STUDY OF THE EFFECT OF REINFORCEMENT STABILITY ON THE CAPACITY OF REINFORCED CONCRETE COLUMNS

Modelling of RC moment resisting frames with precast-prestressed flooring system

CYCLIC BEHAVIOR OF SLENDER R/C COLUMNS WITH INSUFFICIENT LAP SPLICE LENGTH

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

Seismic Detailing of RC Structures (IS: )

Bijan Khaleghi, Ph, D. P.E., S.E.

TESTS ON AN INTERIOR REINFORCED CONCRETE BEAM-COLUMN JOINT. R. Park*, L. Gaerty**, and E.C. Stevenson***

Effect of Axial load on deformation capacity of RC column

Seismic Analysis and Design of Flared Bridge Columns

DUCTILITY REQUIREMENTS FOR BUILDINGS

Special Reinforced Concrete Structural Walls

Seismic Performance of Hollow-core Flooring: the Significance of Negative Bending Moments

Pile to Slab Bridge Connections

ABC-UTC. Research Progress Report (Feasibility Study) Title: Alternative ABC Connections Utilizing UHPC. March, 2017

Inelastic Behavior of Hollow Reinforced Concrete Bridge Columns

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

SEISMIC REHABILITATION OF REINFORCED CONCRETE BRIDGE COLUMNS IN MODERATE EARTHQUAKE REGIONS USING FRP COMPOSITES

Effect of beam dimensions on structural performance of wide beam-column joints

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

Fragility Curves for Seismically Retrofitted Concrete Bridges

MODELLING OF SHEAR WALLS FOR NON-LINEAR AND PUSH OVER ANALYSIS OF TALL BUILDINGS

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

CALTRANS SDC PROCEDURE

TORSIONAL CAPACITIES OF CAP BEAMS IN ELEVATED TRANSPORTATION STRUCTURES

CAUSES OF ELONGATION IN REINFORCED CONCRETE BEAMS SUBJECTED TO CYCLIC LOADING

Cyclic Tests on Prefabricated Bridge Piers

SEISMIC FORCE RESISTING MECHANISM OF THE MULTI-STORY PRECAST CONCRETE SHEAR WALL SUPPORTED ON PILES

EXPERIMENTAL INVESTIGATION OF PRECAST CONCRETE BEAM TO COLUMN CONNECTIONS SUBJECTED TO REVERSED CYCLIC LOADS

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

INHERENT DUCTILITY OF REINFORCED CONCRETE SHEAR WALLS WITH NON-SEISMIC DETAILING

Experimental study on the seismic performance of RC moment resisting frames with precast-prestressed floor units.

SEISMIC PERFORMANCE OF BRIDGE COLUMNS WITH DOUBLE INTERLOCKING SPIRALS

Performance Objectives and the AASHTO Guide Specifications for LRFD Seismic Bridge Design

Modeling of Shear Walls for Nonlinear and Pushover Analysis of Tall Buildings

CHAPTER 1: INTRODUCTION

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

SEISMIC-FORCE-RESISTING MECHANISMS OF MULTI-STORY STRUCTURAL WALLS SUPPORTED ON PILES ABSTRACT

Fragility Curves for Seismically Retrofitted Concrete Bridges

ANNEX 10. Special requirements recommended for structures subject to seismic actions. 1 Scope. 2 Basis of design. 2.1 Fundamental requirements

EVALUATION OF SEISMIC PERFORMANCE OF SLENDER L- SHAPED AND T-SHAPED RC STRUCTURAL WALLS

3-D FINITE ELEMENT ANALYSIS OF PILE-TO-PILE CAP CONNECTIONS SUBJECTED TO SEISMIC ACTION

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

Deformation Capacity of RC Structural Walls without Special Boundary Element Detailing

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Development of a FRP-Wrapped Spiral Corrugated Tube for Seismic Performance of Reinforced Concrete Columns

Lateral Force-Resisting Capacities of Reduced Web-Section Beams: FEM Simulations

by Dr. Mark A. Ketchum, OPAC Consulting Engineers for the EERI 100 th Anniversary Earthquake Conference, April 17, 2006

EXPERIMENTAL EVALUATION OF BRIDGE MONOLITHIC JOINTS UNDER SIMULATED SEISMIC LOADING

Earthquake Design of Flexible Soil Retaining Structures

SEISMIC RESPONSE OF LINEAR, FLANGED, AND CONFINED MASONRY SHEAR WALLS

EVALUATION OF REINFORCED CONCRETE BRIDGE JOINTS

Failure Mechanism of Reinforced Concrete Structural Walls with and without confinement

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

Ductile Detailing for Earthquake Resistant R C Structures. Dr. S. K. PRASAD Professor of Civil Engineering S.J. College of Engineering Mysore

AN EXPERIMENTAL STUDY ON SCALE EFFECTS IN SHEAR FAILURE OF REINFORCED CONCRETE COLUMNS

Inelastic Web Crushing Performance Limits of High- Strength-Concrete Structural Walls

Damage Assessment of Reinforced Concrete Columns Under High Axial Loading

Reinforced Concrete Structures

Beam-column joint tests with grade 500E reinforcing

Earthquake-Resistant Coupling Beams without Diagonal Reinforcement

Reinforced concrete beam-column joints with lap splices under cyclic loading

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

Experimental tests on RC hollow columns strengthened with FRPs

An Overview of Research at HKU on HSRC Columns and Beam- Column Joints for Low-Medium Seismic-Risked Regions

Seismic Evaluation and Retrofit of Bridge Joints

Quasi-static cyclic tests of Emulative Precast Segmental Bridge Piers (E-PSBP)

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

Interaction between ductile RC perimeter frames and floor slabs containing precast units

Modeling of Coupled Nonlinear Shear and Flexural Responses in Medium-Rise RC Walls

SHAKE TABLE TESTING OF BRIDGE REINFORCED CONCRETE COLUMNS UNDER COMBINED ACTIONS

BEHAVIOR OF RC BRIDGE COLUMNS UNDER CYCLIC FLEXURAL-TORSIONAL LOADINGS WITH MODERATE SHEAR

CYCLIC RESPONSE OF RC HOLLOW BOX BRIDGE COLUMNS STRENGTHENED USING CFRP AND RC JACKETING

SHEAR STRENGTHENING OF RC BRIDGE PIERS BY STEEL JACKETING WITH EXPANSIVE CEMENT MORTAR AS ADHESIVE

XTRACT: A Tool for Axial Force - Ultimate Curvature Interactions. C.B. Chadwell 1 and R.A. Imbsen 2

In-plane testing of precast concrete wall panels with grouted sleeve

SHEAR STRENGTH CAPACITY OF PRESTRESSED CONCRETE BEAM- COLUMN JOINT FOCUSING ON TENDON ANCHORAGE LOCATION

PERFORMANCE OF RC BRIDGE COLUMNS SUBJECTED TO LATERAL LOADING

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE COLUMNS UNDER CONSTANT AND VARIABLE AXIAL LOADINGS

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

International Journal of Advance Engineering and Research Development REVISION OF IS: A REVIEW (PART 2)

Cyclic Loading Tests Of Steel Dampers Utilizing Flexure-Analogy of Deformation

EXPERIMENTAL RESULTS

SEISMIC PERFORMANCE OF HIGH-STRENGTH-CONCRETE HOLLOW BRIDGE PIERS UNDER MULTI-DIRECTIONAL LOADING ABSTRACT

Seismic Design of Ductile Shear Walls

DS Attachments. Design Specifications

INELASTIC SEISMIC RESPONSE ANALYSES OF REINFORCED CONCRETE BRIDGE PIERS WITH THREE-DIMENSIONAL FE ANALYSIS METHOD. Guangfeng Zhang 1, Shigeki Unjoh 2

NONLINEAR FINITE ELEMENT ANALYSIS OF NON- SEISMICALLY DETAILED INTERIOR RC BEAM-COLUMN CONNECTION UNDER REVERSED CYCLIC LOAD

SECTION H COLUMNS SUBJECTED TO FLEXURE AND AXIAL

> 0. 1 f, they are treated as beam-columns.

VERIFICATION OF A REINFORCED CONCRETE COLUMN COMPUTER MODEL UNDER UNIAXIAL AND BIAXIAL BENDING LOADING CONDITIONS

EXPERIMENTAL INVESTIGATION ON SEISMIC BEHAVIOUR OF KNEE JOINTS IN REINFORCED CONCRETE FRAMES

Masonry infills with window openings and influence on reinforced concrete frame constructions

Seismic Design and Retrofit. Reginald DesRoches Professor and Associate Chair Georgia Institute of Technology

Modelling of Reinforced Concrete Core Walls Under Bi-directional Loading

7. SPECIFIC RULES FOR STEEL CONCRETE COMPOSITE BUILDINGS

PERFORMANCE OF EXTERIOR PRECAST UNDER CYCLIC LOADING. R. Vidjeapriya & K.P. Jaya Anna University, Chennai , India 1.

Seismic response of a cast-in-place steel fibre concrete joint connecting precast beams and columns

DISPLACEMENT-BASED SEISMIC DESIGN OF CONCRETE BRIDGES

Transcription:

SEISMIC BEHAVIOR OF FOUR-CIDH PILE SUPPORTED FOUNDATIONS José I. Restrepo 1, Inho Ha 2 and M.J.Nigel Priestley 3 Abstract This paper discusses the results of two large-scale models of Four-Cast-In-Drilled- Hole (FCIDH) pile supported bridge piers tested under bi-directional reversed cyclic loading conditions. The test units were designed according to state-of-the-art bridge design requirements. The pile cap of the first test unit contained conventional reinforcing detailing while the second unit had headed bars. The test units performed well in terms of the ductility and energy absorption capacity. This paper reports the main findings of the test program and also discusses the implications in design of FCIDH pile supported foundations of bridge piers. Introduction The seismic behavior of the FCIDH pile supported footing systems is the focus of this paper. In California a Capacity Design is followed to ensure the development of plastic hinges in columns and to keep all other bridge elements, including the foundation, elastic. In general, the number of piles is obtained by distributing the column shear force, determined for the plastic hinge flexural overstrength, evenly among piles. The design for shear in the piles is consistent with this even distribution of forces. However, when reinforced concrete piles are elastic, the distribution of moment and shear force in the footing and in the piles can be significantly affected by the axial force in the piles, because of the dependency of the flexural stiffness on axial force. The moment and shear force in the piles are also affected by the rotation of the pilecap caused by the vertical stiffness of pile-soil interaction, and lateral passive soil pressure on the vertical face of the footing. Furthermore, the influence of the three dimensional geometry of the foundation on the shear direction of the elastic pile can also affect the magnitude of the bending moment acting on the piles. The experimental program involved two half-scale seismic tests on full columnfooting-pile assemblies. The test units were capacity designed using conventional and headed reinforcement. The column-pilecap and pile-pilecap joint regions were designed using the external joint strut approach proposed by Priestley et al. (1996). 1 Associate Professor, Dept. of Structural Engineering, University of California, San Diego 2 Structural Engineer, Daewoo Corporation Engineering and Construction, Korea 3 Emeritus Professor, Dept. of Structural Engineering, University of California, San Diego

Experimental Work To investigate the distribution of shear forces in FCIDH piles and the overall seismic response in FCIDH pile supported footings, two half-scale units were designed in accordance to current seismic design recommendations (ATC, 1996). The main difference between the test units was the amount of reinforcement and type. Unit-1 was designed with conventional deformed bars and details. Unit-2 differed from Unit-1 in that headed reinforcement was used throughout, except or the column and pile transverse reinforcement. The units were tested twice, each under a different boundary condition. In the first test, termed here Loading Phase 1, restraint devices were placed to simulate passive pressure conditions. Fifty percent of the lateral load applied to the column was resisted by the passive pressure mechanism and the piles resisted the remaining fifty percent. In the second test, or Loading Phase 2, the restraint devices were removed to represent gapping between the soil and the piles. Inelastic pile behavior was expected in this phase of testing. The test units were the prototype pier consisted of FCIDH piles, a pilecap, a single column and a superstructure. The reinforcement details of the prototype were not utilized in the design of the test units. In order to examine the seismic performance of a FCIDH pile supported footing under laboratory conditions, the test units were built at one-half scale and without the superstructure. The geometry and general reinforcement details of Unit-1 and Unit-2 are shown in Fig. 1. For desirable seismic response the units were designed so that a plastic hinge would develop at the base of the column. Using capacity design principles, the pilecap and joints were designed for the maximum possible forces that would develop in the column plastic hinge, considering potential strain hardening and uncertainties in material strengths. With assumed material strengths f c = 27.6 MPa and f ye = 455 MPa. Since there were orthogonal and diagonal loading directions with two conditions of pilecap restraints in each loading direction, four loading cases were considered for the design of the test units. Unit-2 was designed after the test on Unit-1 had been completed. Unit-2 incorporated minor modifications except pilecap reinforcement, based primarily on the experience gained from testing the Unit-1, and used headed reinforcement to improve anchorage of reinforcement. The column longitudinal reinforcement ratio of ρ l = 0.026 and was subjected to an arbitrary axial compression equal to 0.16 Agf ce. the volumetric confinement ratio of the column was ρ s = 0.0112 and exceeded the required value of ρ s,req = 0.0089. The piles of the two units were designed for the worst possible scenario, expecting pile plastic hinging caused by loading in the diagonal direction without restraint being provided by the pilecap passive pressure mechanism of lateral force resistance. A pile longitudinal reinforcement ratio of ρ l = 0.0089 was determined to ensure the piles would remain elastic in Loading Phase 1. This reinforcement ratio was determined through an iterative process, considering all possible loading scenarios assuming that lateral loading,

when applied in the diagonal direction, resulted in no additional axial force being developed in the mid-piles. The removal of the passive pressure mechanism in Loading Phase 2 meant that lateral forces applied at the top of the column had to be resisted entirely by the piles. In this situation the mechanism of plastic deformation was expected in the piles since the ratio of the yield strength of the pile group to the maximum applicable lateral load was 0.84 for both orthogonal and diagonal direction loadings. Consequently, the piles were detailed for ductility to enable the development of plastic hinges immediately below the pilecap face. Transverse reinforcement with ρ s = 0.0087 was provided to satisfy the seismic design requirements for California bridges (ATC, 1996). Assuming that the plastic hinge length and the curvature distribution in the piles are independent from axial force, the lateral force applied at the top of the column would can distributed in the piles in proportion to the secant flexural rigidity, providing that the length of the piles to the point of inflection is the same. The shear force for the design of the piles was derived using this concept and the compression pile was critical. The shear demand in tension pile was small enough to be neglected. With a shear strength reduction factor of φ = 0.85, the shear capacity of the compression pile greatly exceeded the demand. s Shear forces in the piles, at the ultimate curvature of the pile with highest compression, were apportioned in proportion to the secant flexural rigidities of piles. The secant flexural rigidity of each pile was obtained from moment-curvature analyses for the piles with different axial forces. A significant portion of the toal shear force was apportioned to the piles in compression. The pilecap joints of the test units were designed with reduced amounts of reinforcement by explicitly identifying an internal force flow (ATC, 1996; Priestley et al. 1996). The joint principal tensile stress, pt, was calculated to determine whether the joint reinforcement was needed to transfer joint forces. The average principal tensile stresses of the joints at the overstrength were estimated to be 0.52 f [MPa] and 0.09 f [MPa] for the column-pilecap and the pilecap-pile joints, c c respectively. When comparing these values to the joint design threshold values, it was concluded that only the column-pilecap joint should be detailed to ensure appropriate force transfer mechanism for satisfactory internal force flow through the joint (ATC, 1996; Priestley et al., 1996). Because t 0.29 f c p [MPa] for the pilecap-pile joint, joint shear cracking was not expected, and only nominal joint reinforcement satisfying 0.29 fc / fyh was provided in the form of spirals. The longitudinal column bars were extended into the joint as close to the bottom pilecap reinforcement as possible. The embedment length of the column bars was 711 mm, which was almost the minimum required anchorage length obtained for #8 bars.

Tests on column-pilecap connections (Priestley et al., 1996) have indicated that to ensure the pilecap reinforcement remains elastic, the flexural reinforcement must be placed within an effective width of b eff = D p + 2 d f (Ingham, et al., 1994), where D p is the diameter of the column and d f is the effective depth of the pilecap. For anchorage, this reinforcement had 90 o hooks at each end, extending down the vertical face to 254mm from the pilecap soffit. It was assumed, as is common design practice, that the critical moment in the pile cap would develop in the vertical plane at the column face. This is non-conservative, as demonstrated by the test performance of Unit-1, and that modification was made for Unit-2, as discussed subsequently. In the test units the piles were connected to the test base using a pin detail, see Fig. 2. The pin connection between the piles and the test base was achieved by terminating all the longitudinal column reinforcement just above the test base, reducing gross area of the pile circular section from 508 mm to 203 mm at the interface of pile and test base, and by providing a plain round steel rod at the centers of the piles. Test Set-up and Procedure The units were tested under bi-directional reversed cyclic loading conditions. Fig. 3 shows the test set-up of Unit-1. Two 2.5 MN capacity hydraulic actuators were placed at 90 o atop the column. Lateral force was applied to the column with these actuators. Axial load was applied to the columns using four center-hole jacks. The test units were subjected to two phases of loading. In the first phase, lateral actuators were placed at the level of the pile cap and force-controlled to resist 50% of the lateral force applied to the column. In the second phase of loading, the passive pressure restraint was removed to simulate gapping between the pile cap and the soil. Only the results of the first phase of loading are discussed in this paper. The test was performed quasi-statically with force- and displacement-controlled cycles. The first part of the test consisted of force-controlled cycles at 25%, 50%, 75% and 100% of the theoretical first yielding of the longitudinal reinforcement in the column. The following loading steps, beyond theoretical first yielding of the longitudinal column bar in the column, were displacement-controlled. Using the measured first yield displacements in all the loading directions, an average reference yield displacement corresponding to system s displacement ductility,, was derived from the following equation: where M µ 1 = y(ave) (1) M y(ave) the column, column. y y is the average system displacement for all loading directions at the first yield of M y is the first yield moment and M y is the reference yield moment of the

Displacement-controlled reversed cyclic loading was applied afterwards to µ = 1, 1.5, 2, 3, 4, 5, where µ = / µ 1 and is the lateral displacement at the top of the column. Lateral loading was applied to each normal direction with two cycles and each diagonal direction with one cycle at each system displacement ductility level in order that all the structural members experience the same level of loading. Test Results Unit-1 In Loading Phase 1, the column developed a plastic hinge as expected. However, unexpected, and difficult to repair, spalling of the concrete cover was observed at the pilecap soffit during this phase of loading. Spalling was caused by straightening of 90 o J- hooks that had been placed as shear reinforcement in the pilecap, see Fig. 4. Fig. 5 plots the measured lateral force-displacement hysteretic response in the E-W direction of Unit-1 during Loading Phase 1. Th e response of the unit was stable and the loss of the concrete cover in the soffit of the pilecap did not affect the response. Unit-2 The response of this unit was as expected. In Loading Phase 1, the column developed a plastic hinge and in Loading Phase 2, plastic hinges developed in the piles. The use of headed reinforcement effectively precluded the spalling of the concrete cover in the pilecap. Moreover, modifications to accommodate the flexural moment demands taken into account in the footing design of Unit-2 hampered any inelastic behavior in this region. No damage in the joint region was observed either. Fig. 6 shows the bottom surface of the pilecap of Unit-2 at the end of the test which exhibited only minor damage compared to the bottom surface of Unit-1 as shown in Fig. 5. As for Unit-1, the hysteretic response of Unit- 2 was stable and typical of a bridge component designed for full ductility response, see Fig. 7. Discussion Observations and data analysis of the response of the test units highlighted the following two main issues of concern that are not be currently been addressed in design: Critical Loading Direction for Pile Design A significant finding of the test program is that the principal direction of the pile resistance is skew with respect to the direction of the shear force in the column. This observation is made based on the inclination of the plane of bending the piles. The instrumentation deployed in the piles enabled the equation of the plane of bending to be determined.

The neutral axis locations of pile A when subjected to EW loading, that induced compression in this pile of Unit 2, are illustrated in Fig. 8. If assuming that the shear force carried by the pile is orthogonal to the direction of the neutral axis depth, then the direction of the pile shear force at peak loading was approximately 55 o with respect to the column loading direction. Skewness of the neutral axis with respect to the applied shear force implies that two dimensional frame analyses, which result in forces parallel to the loading direction, will underestimate the magnitude of the shear force demand in the piles. Shear Distribution Between Compression and Tension Piles Fig. 9 shows the distribution of the applied lateral force between the compression and tension piles in Unit 2 during Loading Phase 1. It is evident in this figure that the applied lateral force is very unevenly distributed between tension and compression piles. The piles in compression resist a large portion of the applied lateral force. Because of the assumption of equal stiffness in the tension and compression piles in current design, lateral forces are distributed somewhat equally between the piles. This issue, when taken together with the issue of the skewness of the shear force in the piles, will result in a significant underestimation of the pile design shear force in the piles and could lead to premature and undesirable shear failure in the foundation structure. Conclusions The following conclusions have been drawn from the experimental study which investigate the combined effect of axial force and moment direction of FCIDH pile supported bridge piers tested under bi-directional reversed cyclic loading conditions: 1) The pile/pilecap joints, which were designed using the external strut shear force transfer mechanism, exhibited satisfactory performance when subjected to simulated seismic loading. However, the column/pilecap joint of Unit-1 experienced spalling of the pilecap cover concrete at several J-stirrup locations, indicating straightening of the 90 o hooks. Unit-2, which used headed bars for the shear stirrups, showed no damage during the test. 2) The principal direction of elastic pile resistance was at an angle to the applied lateral force under orthogonal direction loading. This implies that the shear force in the piles is greater than that determined from a simple plane-frame analysis. 3) It was found that the piles in compression attracted greater shear force than tension piles. The compression pile shear force component in the loading direction was much greater than that of tension pile. It is noted that the current analysis procedures, in which the piles are modeled with a unique flexural stiffness value, can greatly underestimate the pile design shear force.

4) The combination of the findings described in 2) and 3) above, can result in a large underestimation of the design shear force of piles of FCIDH pile supported bridge piers and could result in premature and undesirable foundation structure failure. 5) The performance of Unit-2 using headed reinforcement was satisfactory. No damage occurred to the pilecap and joints of Unit-2. Normal minimum embedment length were satisfied in the test using headed reinforcement. Acknowledgments This research was possible by funding from California Department of Transportation. Headed reinforcement incorporated in the second test unit was donated by the Headed Reinforcement Corporation. Large-scale full column-pilecap-four piles assembly test units were constructed and tested at the Charles Lee Powell Laboratory of the University of California, San Diego. Their support is gratefully acknowledged. References Applied Technology Council, 1996, Improved Seismic Design Criteria for California Bridges : Provisional Recommendations. ATC-32. Ingham, J. M., Priestley M. J. N. and Seible, F., 1994, Seismic Performance of Bridge Knee Joints Volume I, Structural Systems Research Project, Report No. SSRP-94/12, University of California at San Diego, California. Priestley M. J. N., Seible, F., Calvi G. M., 1996, Seismic Design and Retrofit of Bridges. John Wiley & Sons, New York.

(a) Unit-1 (b) Unit-2 Figure 1- General geometry and reinforcing details of test units

Figure 2 Pin connection details between pile and base block Figure 3 - Test set-up of Unit-1

Figure 4 - Straightening of 90 o J-hook at the end of test of Unit-1 Figure 5- East-West hysteretic response of Unit - 1 during Loading Phase 1

Figure 6 - Pilecap soffit at the end of test of Unit 2 Figure7- East-West hysteretic response of Unit - 2 during Loading Phase 1

Figure 8 - Neutral axis locations for Pile A of Unit-2 during Loading Phase 1 Figure 9 - Shear force distribution between compression and tension piles of Unit 2 during Loading Phase 1