CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that B83 Testing & Engineering, Inc. 3040 West Hopkins Street Milwaukee, WI 53216 has been assessed by ANAB and meets the requirements of international standard ISO/IEC 17025:2005 while demonstrating technical competence in the field of TESTING Refer to the accompanying Scope of Accreditation for information regarding the types of tests to which this accreditation applies. L2062-1 Certificate Number Certificate Valid: 10/16/2018-02/24/2022 Version No. 002 Issued: 10/16/2018 This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017).

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 B83 Testing & Engineering, Inc. 3040 West Hopkins Street Milwaukee, WI 53216 Bryon Martin 414-449-9396 bmartin@b83test.com www.b83test.com TESTING Valid to: February 24, 2022 Certificate Number: L2062-1 Mechanical Tensile Compression Shear Torsion Axial Fatigue Torsional Fatigue Durability Simulation SAE J684; SAE J2638 VESC V-5; ISO/FDIS 15818 SAE J684; SAE J2638 VESC V-5; SAE J684; SAE J2638 VESC V-5; PF 90238, Customer Provided Road / Load Profiles PF 90238 Linear Actuators (Hydraulic, Pneumatic and Electric) Force: Up to 1,300 kn (300k lbf) Displacement: Up to 1.8 m (72 inch) Rotary Actuators (Hydraulic and Pneumatic) Torque: Up to 56,500 Nm (500k lbf inch) Test Control: Static, Ramp, Cyclic and Time History Replication Page 1 of 5

Mechanical Acceleration FAR 23.561; FAR 25.561; FAR 27.561; MIL-STD-810 (Method 513); 2001); MIL-STD-202 (Method 212); Customer specifications Centrifuge Up to 80 g with 0.6 m (24 inch) arm Mechanical / Environmental Simulation Temperature PF-90171 PF-9239 Bellcore GR63 CORE (sect. 5.1) MIL-STD-810 (Method 501) MIL-STD-810 (Method 502) 1008) 1010) ETSI EN300 019-2-1 v.2.1.2 ETSI EN300 019-2-2 v.2.1.2 ETSI EN300 019-2-3 v.2.2.2 RTCA DO 160 (sect. 5) SAE J1211 (sect. 4.1) SAE J1455 (sect. 4.1) Temperature Chambers -73 C to 260 C (-100 F to 500 F) Page 2 of 5

Mechanical / Environmental Simulation Humidity PF-90171 Bellcore GR63 CORE (sect. 5.1) MIL-STD-810 (Method 507) MIL-STD-202 (Method 103B) 1004) ETSI EN300 019-2-1 v.2.1.2 ETSI EN300 019-2-2 v.2.1.2 ETSI EN300 019-2-3 v.2.2.2 RTCA DO 160 (sect. 6) SAE J1211 (sect. 4.2) SAE J1455 (sect. 4.2) Temperature/Humidity Chambers 10% RH to 95% RH Thermal Shock 1010) MIL-STD-202 (Method 107) MIL-STD-810 (Method 503) Thermal Shock Chambers (2-Zone, Air-to-Air) -73 C to 260 C (-100 F to 500 F) Page 3 of 5

Vibration Vibration (Sine & Random) PF-90171 MIL-STD-810 (Method 514); MIL-STD-810 (Method 519); MIL-STD-167-1A; MIL-STD-202 (Methods 201A, 204D, 214A); 2005); 2007); ETSI EN300 019-2-1 v.2.1.2; ETSI EN300 019-2-2 v.2.1.2; ETSI EN300 019-2-3 v.2.2.2; ANSI C136.31-2001 IEC 60068-2-64; IEC 60068-2-6; RTCA DO 160 (sect. 8); SAE J1211 (sect. 4.7); SAE J1455 (sect. 4.9);, Customer Provided Road / Load Profiles Agriculture, Government Defense, Vibration Test System (Electro-Dynamic and Servo-Hydraulic) DC to 3,000 Hz Up to 80 kn (18k lbf) Page 4 of 5

Vibration Note: Mechanical Shock MIL-STD-810 (Method 516); MIL-STD-202 (Method 213B); 2002); ETSI EN300 019-2-1 v.2.1.2; ETSI EN300 019-2-2 v.2.1.2; ETSI EN300 019-2-3 v.2.2.2; IEC 60068-2-27; RTCA DO 160 (sect. 7); SAE J1211 (sect. 4.8); SAE J1455 (sect. 4.10); 1. This scope is formatted as part of a single document including Certificate of Accreditation No. L2062-1. Shock Test Systems (Electro-Dynamic and Pneumatic) Up to 500 g Page 5 of 5