Covering

Covering Design Regions

Roof Covering

Roof Covering (SSR) 24 coverage w/ 3 seam height Machine seamed, in-place Attached to roof secondary (purlins, widebay truss purlin or bar joist) w/ a concealed sliding clip which allows 1 5/8 thermal movement each direction, 3 1/4 total

SSR PANEL CLIPS Fixed Sliding

Center Seaming Tab in Slot (2) Fasteners Per Clip At Endlaps and Ridge End. Clip Must Be Installed Under Panel Stiffener

Note: Taller SSR clips are used with thermal block/super block. Adjustments may be desired in eave height input which is measured from top of purlins.

SSR Profile

Roof Covering (SSR) Weather-tight roof system 24 gage w/ 22 gage available upon special request 25 year Finish Warranty Galvalume KXL (Kynar 500 or Hylar 5000 ) Variety of colors to choose from Use with Blanket Insulation up to 6 thick (over purlins) or Rigid Board up to 3 1/2 thick ¼ : 12 minimum roof pitch

Roof Covering (SSR)

SSR Staggered Lap Panel lap is 9 above the Purlin Staggered Lap is typically 5-0 (purlin spacing) Sheet either direction, except with Tuflites Notch is factory applied

SSR Staggered Lap

SSR Ridge

SSR Ridge Detail

SSR Ridge Detail

SSR and HWR Profile

SSR High Wind Roof The HWR roof system is primarily intended for the higher coastal wind regions, Caribbean, etc.. It is not intended to replace the SSR roof system with 90 to 110 mph +/- winds. The SSR system, with lower wind speeds, would be cheaper than the HWR. The HWR with higher winds will price out in most all cases. For wind speeds greater than 110 mph, and up to 200 mph, the HWR roof system will design w/o unpriced items. (assumes that one would select deeper depth purlins as required) Purlin spaces for the 110 to 200 mph case above ranged from 4 6 to 5 0 in the roof field and rakes, eaves lower.

SSR HWR

HWR Clips

HWR Factory Mutual (FM) ratings with 5-0 purlin spacing and 24 gage panel Florida, Miami-Dade approved UL approved expansion and contraction is the same as standard SSR as limited by the bull-nose style ridge trim Same eave and rake trims as SSR

HWR 8 is the standard clip length used at all purlins 12 clip used at corner and edge zone conditions where 8 clips not sufficient Used with ZEE purlins in depths of 8 ½, 10, and 11 ½ Purlin Channel bracing required May not be used with 7 deep purlins(due to purlin channel bracing being required) Superblock not available at this time

SSR High Wind Roof No rake subpurlins needed. (possibly with FM rated assemblies requiring reduced spaces) VPCommand will automatically populate the rake and corner zones with 12 clips as required for design. Great FM ratings with 5 purlin spaces and 24 ga. panels Florida, Miami-Dade approved. UL approved. Expansion/contraction same as SSR as limited be the bull-nose style ridge trim. Same eave and rake trims as SSR.

SSR

SSR

SSR Fixed Eave

SSR Fixed Centerline (Floating Eave)

SSR Fixed Eave

SSR Fixed CL / Floating Eave

SSR 6 Roof Step Expansion

Expansion & Contraction

Expansion & Contraction

Floating Roof System

SSR Insulation over purlins

SSR Thermal Block

SSR Module Strip

SSR SuperBlock

Thermal Performance - PR

Thermal Performance - SSR

Thermal Performance-SSR (Thermal Block)

Thermal Performance-SSR (Superblock)

Seamer Tool

Seamer Tool

Contact your VP Service Center for assistance. SSR Seam Clamp

Roof Covering Standing Seam (SSR) Panel Rib (PR)

Panel Rib

Roof Covering (PR) 36 coverage Available in 26, 24, & 22 gages Available in Galvalume & KXL finishes

Roof Covering (PR) Attached to purlins with selfdrilling fasteners Use with Blanket Insulation up to 4 thick 1 / 2 :12 minimum roof pitch Cannot be used on TP/bar joist

Panel Rib

Roof Covering Standing Seam (SSR) Panel Rib (PR) SLR II

Roof Covering (SLR II) 2 SLR II Architectural Standing Seam Roof System (2 Seam Height) Available in a variety of KXL colors

Roof Covering (SLR II) 16 Coverage with 2 Seam Heights Machine seamed in-place Attached to roof secondary (purlins or bar joist) w/ a concealed clip which allows 1 thermal movement. Weather tight Roof System

SLR II

Roof Covering (SLR II) 24 Gage only with 2 High Rib 25 - Year Warranted KXL Finishes Variety of colors to choose from Use with Blanket Insulation up to 6 thick Thermal Blocks are Required

SLR II Ridge Detail

SLR II

SLR II

SLR II

SLR II

SLR II

Thermo-Deck System

Components

TLS Processing Guidelines The roof panel lengths will need adjustment at the splices. Panel lengths will need to be adjusted by the rise of the depth of the TLS System

VP Roof Factory Mutual SSR and SLR II Roof Systems are approved in various type applications and listed in the FM Approval Guide. 24 Ga SSR is available in Class 1-60, 1-75, 1-90 22 Ga SSR is available in Class 1-75, 1-90, 1-120 24 Ga SLR is available in Class 1-90, 1-120.

Walls: PR, VR, RPR Roofs: PR, SSR

PR, VR, SSR

SLR II

Cool Roofing (reduces heat island effect)

Covering Wall Covering

Wall Covering Panel Rib (PR) Vee Rib (VR) Reverse Panel Rib (RPR)

Wall Covering Panel Rib (PR)

Panel Rib (PR) 36 Coverage Available up to 41-0 long Variety of end conditions available Available with KXL & Galvalume finishes Fasteners match wall color 26, 24 & 22 available Use with insulation up to 4 thick

Crimped Base Panel Rib

Crimped Base Panel Rib

Crimped Base Panel Rib

Crimped Base Panel Rib

Panel Rib Wall

Panel Rib Wall

Vee Rib Wall

Vee Rib (VR) 36 Coverage Available up to 41-0 long Stucco Embossed Panels available KXL finishes Fasteners match wall color 26, 24, & 22 gage Use with insulation up to 4 thick

Vee Rib Base

Vee Rib

Vee Rib

Wall Covering Reverse Panel Rib (RPR)

Reverse Panel Rib (RPR) 36 Coverage Available up to 41-0 long Available with KXL & Galvalume finishes Fasteners match wall color 26, 24 & 22 available Use with insulation up to 4 thick

Reverse Panel Rib (RPR)

Reverse Panel Rib (RPR)

Wall Covering Panel Rib (PR) Vee Rib (VR) Reverse Panel Rib (RPR)

Wall Covering Crating Options: Max. Cnt. per Crate Request a maximum quantity of panels per crate / bundle to Manufacturing. Max. Wt. per Crate Request a maximum weight of panels per crate / bundle to Manufacturing. Max. Dist. Combine Sets The maximum distance between like panel set to be combined.

Wall / Roof Material NBVP The builder is must supply the actual weight of these materials.the weights on this page are only for reference. WALLS ROOFS Brick Copper or tin 1 psf 4" 40 psf Corrugated steel See Manufacture 8" 80 psf 3-ply ready roofing 1 psf 12" 120 psf 3-ply felt and gravel 5 1/2 psf 5-ply felt and gravel 6 psf Hollow Concrete Block (Heavy Aggregate) 4" 30 psf Shingles 6" 43 psf Wood 2 psf 8" 55 psf Asphalt 3 psf 12 1/2" 80 psf Clay tile 9-14 psf Slate 1/4" 10 psf Hollow Concrete Block (Light Aggregate) 4" 21 psf Sheathing 6" 30 psf Wood 3/4" 3 psf 8" 38 psf Gypsum 1" 4 psf 12" 55 psf Insulation (per 1" thick) Miscellaneous Loose 1/2 psf Window, glass, frame, & 8 psf Poured-in-place 2 psf sash Rigid 1 1/2 psf

Thermal Performance PR, VR

FP-12 Soffit FP 12 Soffit panel only Flush Panel Design 12 Module 7/8 Panel Height 24 and 22 Gage No Clips Required Available vented (perforated) & Stiffening Beads ( 1 or 2)

Girt Strapping for Panel NBVP

FP-12 Soffit

Texture Clad

TextureClad 16 Wide Coverage Lengths 2 to 22 Stackable Panels 20 gage G-90 Galvanized Steel Concealed Fastener Installation Attaches Directly to Wall Girts (max. span of 5-6 )

TextureClad

Aspen Ice Arena

OMETEK

TextureClad Close-up of window and door trim

TextureClad

TextureClad

ThermalClad Wall Panels Architectural (36 Width) Planked (42 Width) Reveal (42 Width) Tuff-Wall (42 Width) Roof Panel TCR 42 (42 Width) Thickness: 2, 2.5, 3 & 4

ThermalClad Wall Panel Length 8-32 26 Gauge Interior Exterior Gauge Varies Stucco Embossed Concealed Fastener Max R Value 29.42 PVDF Finish Reveal

ThermalClad Roof Panel 42 Wide Length 8-50 24 Gauge Exterior Stucco Embossed Concealed Fastener Max R Value 32.3 PVDF Finish 2 High SLR Rib TCR - 42 TCR - 42

Oil Canning (NOT VP Buildings)

Oil Canning (NOT VP Buildings)

Oil Canning

Oil Canning-Ways to Reduce

Oil Canning-Ways to Reduce

Oil Canning-Ways to Reduce

Oil Canning