EJOT frame anchor. Direct fastening of windows in masonry and concrete, without any anchors.

Similar documents
Transcription:

EJOT frame anchor Direct fastening of windows in masonry and concrete, without any anchors www.ejot.com

Window instaation masonry / concrete EJOT frame anchor type RA-P 7.5 40 1,200 type RA-P 7.5x40 2 231 040 601 7.5 60 1,200 type RA-P 7.5x60 2 231 060 601 7.5 70 1,200 type RA-P 7.5x70 2 231 070 601 7.5 80 1,200 type RA-P 7.5x80 2 231 080 601 7.5 90 1,200 type RA-P 7.5x90 2 231 090 601 7.5 100 600 type RA-P 7.5x100 2 231 100 601 7.5 120 600 type RA-P 7.5x120 2 231 120 601 7.5 135 400 type RA-P 7.5x135 2 231 135 601 7.5 150 400 type RA-P 7.5x150 2 231 150 601 7.5 180 400 type RA-P 7.5x180 2 231 180 601 7.5 210 400 type RA-P 7.5x210 2 231 210 601 7.5 250 50 type RA-P 7.5x250 2 231 250 601 7.5 300 50 type RA-P 7.5x300 2 231 300 601 l l Direct fastening of plastic windows in masonry and concrete, without any anchors l l Instaation according to the RAL quality association guidelines for windows and l l Burglary resistant (), tested on steel-free plastic windows Tested as fastening element acc. to the ETB guidelines "Building components which protect against faing from heights" l l Fast instaation, reliable anchoring l l including white RAL 9010 push-on caps Instaation process l l Dri 6.2 mm frame holes, in-plant or on l l Dri holes into stone, dri hole depth = instaation depth + 10 mm Push-on cap if necessary Minimum instaation depth Verticay perforated brick, Hoow block, timber Verticay perforated brick Plan Pre-driing / driing method 11 mm Hammer driing Rotary driing, rotary driing With regards to edge distances, the manufacturer's instructions must be observed. ETB when instaing burglar-proof or anti-fa devices!

Window instaation masonry / concrete EJOT frame anchor type SA-H 7.5 60 1,200 type SA-U 7.5x60 2 249 060 601 7.5 80 1,200 SA-H 7.5x80 2 249 080 601 7.5 100 600 SA-H 7.5x100 2 249 100 601 7.5 120 600 SA-H 7.5x120 2 249 120 601 7.5 135 400 SA-H 7.5x135 2 249 135 601 7.5 150 400 SA-H 7.5x150 2 249 150 601 7.5 180 400 SA-H 7.5x180 2 249 180 601 l l Direct fastening of wooden or aluminumwood windows in masonry and concrete, without any anchors l l Instaation according to the RAL quality association guidelines for windows and lburglary-resistant l () l l Fast instaation, reliable anchoring l l Slim head pus into the wooden outer frame flush with the surface Instaation process l l Dri 6.2 mm frame holes, in-plant or on l l Dri holes into stone, dri hole depth = instaation depth + 10 mm when instaing burglar-proof or anti-fa devices! Minimum instaation depth Verticay perforated brick, Hoow block, timber Verticay perforated brick Plan Pre-driing / driing method 7. T25 Hammer driing Rotary driing Rotary driing With regards to edge distances, the manufacturer's instructions must be observed. T25

Window instaation masonry / concrete EJOT frame anchor type RA-U 7.5 40 1,200 type RA-U 7.5x40 2 261 040 601 7.5 60 1,200 type RA-U 7.5x60 2 261 060 601 7.5 70 1,200 type RA-U 7.5x70 2 261 070 601 7.5 80 1,200 type RA-U 7.5x80 2 261 080 601 7.5 100 600 type RA-U 7.5x100 2 261 100 601 7.5 120 600 type RA-U 7.5x120 2 261 120 601 7.5 135 400 RA-U 7.5x135 2 261 135 601 7.5 150 400 RA-U 7.5x150 2 261 150 601 7.5 180 400 RA-U 7.5x180 2 261 180 601 7.5 210 400 RA-U 7.5x210 2 261 210 601 l l Direct fastening of plastic and wooden windows in masonry and concrete, without any anchors l l Instaation according to the RAL quality association guidelines for windows and l l Burglary resistant (), tested on steel-free plastic windows. l l Fast instaation, reliable anchoring l l A-purpose for various window materials Instaation process l l Dri 6.2 mm frame holes, in-plant or on Dri holes into stone, dri hole depth = instaation depth + 10 mm common tools Push-on cap if necessary when instaing burglar-proof or anti-fa devices! Minimum instaation depth Verticay perforated brick, Hoow block, timber Verticay perforated brick Plan Pre-driing / driing method 8. Hammer driing Rotary driing Rotary driing With regards to edge distances, the manufacturer's instructions must be observed.

Window instaation masonry / concrete EJOT frame anchor type RA-Z 7.5 120 400 RA-Z 7,5x120 2 271 120 601 7.5 150 400 RA-Z 7.5x150 2 271 150 601 7.5 180 400 RA-Z 7.5x180 2 271 180 601 7.5 210 400 RA-Z 7.5x210 2 271 210 601 7.5 250 50 RA-Z 7.5x250 2 271 250 601 7.5 300 50 RA-Z 7.5x300 2 271 300 601 l l Direct fastening of plastic and wooden windows in masonry and concrete, without any anchors Especiay suited for PVC outer frame without reinforcing steel rods l l Instaation according to the RAL quality association guidelines for windows and Sleek and broad supported head (12 mm) Burglary resistant (), tested on steel-free plastic windows Tested as fastening element acc. to the ETB guidelines "Building components which protect against faing from heights" l l Fast instaation, reliable anchoring Instaation process l l Dri 6.2 mm frame holes, in-plant or on Dri holes into stone, dri hole depth = instaation depth + 10 mm Minimum instaation depth Verticay perforated brick, Hoow block, timber Verticay perforated brick Plan Pre-driing / driing method 12 mm Hammer driing Rotary driing Rotary driing With regards to edge distances, the manufacturer's instructions must be observed. ETB when instaing burglar-proof or anti-fa devices!

Window instaation masonry / concrete EJOT frame anchor type MA-D 7.5 40 100 MA-D 7.5x40 2 247 040 601 7.5 60 100 MA-D 7.5x60 2 247 060 601 7.5 70 100 MA-D 7.5x70 2 247 070 601 7.5 80 100 MA-D 7.5x80 2 247 080 601 7.5 100 100 MA-D 7.5x100 2 247 100 601 7.5 120 100 MA-D 7.5x120 2 247 120 601 7.5 150 100 MA-D 7.5x150 2 247 150 601 7.5 180 100 MA-D 7.5x180 2 247 180 601 l l Window instaation into thermal insulation l l Direct fastening in masonry and concrete, without any anchors l l Instaation according to the RAL quality association guidelines for windows and With additional adjustment function through fine thread lburglary-resistant l () l l Fast instaation, reliable anchoring Instaation process l l Dri 6.2 mm frame holes, in-plant or on l l Dri holes into stone, dri hole depth = instaation depth + 10 mm Push-on cap if necessary when instaing burglar-proof devices! Minimum instaation depth Verticay perforated brick, Hoow block, timber Verticay perforated brick Plan Pre-driing / driing method 8. Hammer driing Rotary driing Rotary driing With regards to edge distances, the manufacturer's instructions must be observed.