DESCRIPTION Customized hot wire cut insulation board Several densities : type 1, type 2 and type 3 Other densities available upon request Square cut boards Many dimensions for insulation, lightweight fill enbankment, lettering, etc. SQUARE CUT Any thickness GROOVED CUT Thickness of 1 in (25mm) and more SHIPLAPPED CUT Thickness of 1 in (25mm) and more INSULOK CUT Thickness of 1 in (25mm) and more HYDRONIC CUT Thickness of 1 in (25mm) and more
PRODUCT FEATURES APPLICATIONS UNIFOAM, any cut Residential, commercial, industrial and institutional construction Insulation for interior and exterior walls Insulation for interior and exterior foundation walls Insulation for ceilings and roofs Insulation under and on concrete slabs UNIFOAM, hydronic cut Residential, commercial, industrial and institutional construction Insulation under concrete slabs ADVANTAGES Superior Performance Lightweight and easy to handle Tests results superior to ULC standards Increased comfort: Allows for a stable and uniform indoor temperature year round Hydronic cut: Efficient installation: Hot wire cut notches for uniform insertion of heating pipes Quick installation: Notches allows for setting the pipes without fasteners Economical Permanent insulation value Best quality for the money Energy savings through elimination of thermal bridges Less labour required during installation Ecological 100% recyclable Contains no CFCs or HCFCs Resistant to water and moisture that may be the primary cause of mildew formation Non-toxic, contains 98% air and 2% material Can be handled without health hazards and is non-irritating to skin Can contribute to earning points as part of a LEED project
TECHNICAL DATA SHEET EPS Physical Properties ASTM Test Method Type 1 Requirements UNIFOAM 10 UNIFOAM 20 UNIFOAM 30 Results Type 2 Results Type 3 Results Requirements Requirements Thermal resistance 1 in (25mm) hr F ft²/btu (m 2 C/W) C-518 Min : 3,7 Min : (0,65) 3,87 (0,68) Min : 4,0 Min : (0,70) 4,0 (0,70) Min : 4,2 Min : (0,74) 4,26 (0,75) Water vapour permeability Perm. (ng/pa s m 2 ) E-96 Max : 5,3 Max : (300) 3,67 (208) Max : 3,5 Max : (200) 2,35 (133) Max : 2,25 Max : (130) 1,07 (62) Dimensional stability (%) D-2126 Max : 1,5 0,17 Max : 1,5 0,28 Max : 1,5 0,7 Flexural strength Ib/in² (kpa) C-203 Min : 25 Min : (170) 61 (414) Min : 35 Min : (240) 72 (497) Min : 43,6 Min : (300) 69 (475) Water absorption (%) D-2842 Max : 6,0 4,1 Max : 4,0 1,7 Max : 2,0 0,9 Compressive properties lb/in 2 (kpa) D-1621 Min : 10 Min : (70) 13 (95) Min : 16 Min : (110) 18 (124) Min : 20 Min : (140) 33 (229) Limiting oxygen index (%) D-2863 Min : 24 44 Min : 24 42 Min : 24 32 The maximum continous service temperature F ( C) is 167 (75). The maximum intermittent service temperature F ( C) is 180 (82,2). The coefficient of thermal expansion in/in/ F (mm/mm/ C) is 3,5 x 10-5 (6 x 10-5c-1) as per ASTM D-696 method. AVAILABLE SIZES Standard dimensions of: 2 ft x 4 ft (610mm x 1219mm) 4 ft x 4 ft (1219mm x 1219mm) 2 ft x 8 ft (610mm x 2438mm) 4 ft x 8 ft (1219mm x 2438mm) Other dimensions and densities available upon request. ISO 9001:2015 Certified quality management system ISO 9001:2015 Warning Flammable: interior applications require a protective barrier. The expanded polystyrene used for UNIFOAM boards is Warnock Hersey (WH) certified according to the standard. All installations must comply with the National Building Code. The information and suggestions contained in this brochure are provided solely for informational purposes and are offered in a spirit of collaboration. To our knowledge, we believe the information presented can be considered reliable. This brochure shall not constitute, in any case, a REPRESENTATION or a WARRANTY either EXPRESS or IMPLIED, either in terms of the information, data and suggestions included, or with respect to the absence or violation of any patent or other rights of third parties. Any proposed applications must be evaluated beforehand according to the application context and must, as a result, be adapted or modified to suit local conditions and materials if necessary.
TECHNICAL DATA SHEET UNIFOAM 25 UNIFOAM 40 EPS Physical Properties ASTM Test Method Exigences Type 2 Résultats Type 2 HD Exigences Type 3 Résultats Type 3 HD Thermal resistance 1 in (25mm) hr F ft²/btu (m 2 C/W) C-518 Min : 4,0 Min : (0,70) 4,15 (0,73) Min : 4,2 Min : (0,74) 4,25 (0,75) Water vapour permeability Perm. (ng/pa s m 2 ) E-96 Max : 3,5 Max : (200) 2,01 (115) Max : 2,25 Max : (130) 1,05 (60) Dimensional stability (%) D-2126 Max : 1,5 0,10 Max : 1,5 0,11 Flexural strength Ib/in² (kpa) C-203 Min : 35 Min : (240) 48 (326) Min : 43,6 Min : (300) 99,3 (685) Water absorption (%) D-2842 Max : 4,0 1,7 Max : 2,0 1,3 Compressive properties lb/in 2 (kpa) D-1621 Min : 16 Min : (110) 27 (191) Min : 20 Min : (140) 47 (323) Limiting oxygen index (%) D-2863 Min : 24 42 Min : 24 32 The maximum continous service temperature F ( C) is 167 (75). The maximum intermittent service temperature F ( C) is 180 (82,2). The coefficient of thermal expansion in/in/ F (mm/mm/ C) is 3,5 x 10-5 (6 x 10-5c-1) as per ASTM D-696 method. AVAILABLE SIZES Standard dimensions of: 2 ft x 4 ft (610mm x 1219mm) 4 ft x 4 ft (1219mm x 1219mm) 2 ft x 8 ft (610mm x 2438mm) 4 ft x 8 ft (1219mm x 2438mm) Other dimensions and densities available upon request. UNIFOAM 40 meets the #14301 MTQ requirements. ISO 9001:2015 Certified quality management system ISO 9001:2015 Warning Flammable: interior applications require a protective barrier. The expanded polystyrene used for UNIFOAM boards is Warnock Hersey (WH) certified according to the standard. All installations must comply with the National Building Code. The information and suggestions contained in this brochure are provided solely for informational purposes and are offered in a spirit of collaboration. To our knowledge, we believe the information presented can be considered reliable. This brochure shall not constitute, in any case, a REPRESENTATION or a WARRANTY either EXPRESS or IMPLIED, either in terms of the information, data and suggestions included, or with respect to the absence or violation of any patent or other rights of third parties. Any proposed applications must be evaluated beforehand according to the application context and must, as a result, be adapted or modified to suit local conditions and materials if necessary.
graphite TECHNICAL DATA SHEET EPS Physical Properties ASTM Test Method Type 1 Requirements Results GR5300 Type 1 Thermal resistance 1 in (25mm) hr F ft²/btu (m 2 C/W) C-518 Min : 3,7 Min : (0,65) 5,00* (0,88) Water vapour permeability Perm. (ng/pa s m 2 ) E-96 Max : 5,3 Max : (300) 4,00 (226) Dimensional stability (%) D-2126 Max : 1,5 1,5 Flexural strength Ib/in² (kpa) C-203 Min : 25 Min : (170) 25 (170) Water absorption (%) D-2842 Max : 6,0 1,1 Compressive properties lb/in 2 (kpa) D-1621 Min : 10 Min : (70) 10 (70) The maximum continous service temperature F ( C) is 167 (75). The maximum intermittent service temperature F ( C) is 180 (82,2). The coefficient of thermal expansion in/in/ F (mm/mm/ C) is 3,5 x 10-5 (6 x 10-5c-1) as per ASTM D-696 method. *Thermal resistance based on 1 1/16 thickness, as per results published by BASF. AVAILABLE SIZES Standard dimensions of: 2 ft x 4 ft (610mm x 1219mm) 4 ft x 4 ft (1219mm x 1219mm) 2 ft x 8 ft (610mm x 2438mm) 4 ft x 8 ft (1219mm x 2438mm) Other dimensions and densities available upon request. ISO 9001:2015 Certified quality management system ISO 9001:2015 Warning Flammable: interior applications require a protective barrier. The expanded polystyrene used for UNIFOAM boards is Warnock Hersey (WH) certified according to the standard. All installations must comply with the National Building Code. The information and suggestions contained in this brochure are provided solely for informational purposes and are offered in a spirit of collaboration. To our knowledge, we believe the information presented can be considered reliable. This brochure shall not constitute, in any case, a REPRESENTATION or a WARRANTY either EXPRESS or IMPLIED, either in terms of the information, data and suggestions included, or with respect to the absence or violation of any patent or other rights of third parties. Any proposed applications must be evaluated beforehand according to the application context and must, as a result, be adapted or modified to suit local conditions and materials if necessary.
INSTALLATION TIPS Hydronic Cut 1. Lay under the concrete slab only. The ground must be flat and levelled (ideally compacted). 2. If needed, apply a vapour-barrier membrane on the ground before covering your surface with UNIFOAM boards. 3. Insert hydronic floor heating pipes in the required direction between notches. Use 1/2 in (13mm), 5/8 in (16mm) or 3/4 in (19mm) pipes. 4. Once pipes are installed, you can pour concrete directly onto UNIFOAM boards Refer to your local Building Code.