Methods for Increased Sample Throughput with Dirty Samples

Similar documents
Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

Evaluating Inert Flow Path Components and Entire Flow Path for GC/MS/MS Pesticide Analysis

Application Note. Abstract. Authors. Environmental

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

Analysis of Semivolatiles by GC/FID using the Ultra Inert Inlet Liners with Wool

Multiresidue Pesticide Analysis with the Agilent Intuvo 9000 GC and Agilent 7000 Series Mass Spectrometer

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

Improving GC-MS Method Robustness and Cycle Times Using Capillary Flow Technology and Backflushing

Pesticide Analysis in Drinking Water with Disk Extraction and Large Volume Injection

A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water

Sample Matrix Influence on GC/MS/MS Multiresidue Pesticide Analysis

Introducing a Rugged Core Method for GC/MS/MS Pesticide Residue Analysis

Application Note: Multi-Residue Pesticides in Fruit and Vegetables (9/16/08)

MARKET FOCUSED - environmental ORGANOCHLORINE PESTICIDES

Large Volume Injection of Organochlorine Pesticide Extracts Using a Programmable Temperature Vaporizer in the Solvent Split Mode

Contract Laboratory Program (CLP) Pesticide Analysis with 0.18 mm ID High-Efficiency GC Columns Utilizing Helium Carrier Gas. Application.

Organohalide Pesticides in Water by GC/µECD with Agilent J&W DB-CLP1 and DB-CLP2

Eliminate Invisible High Boiling Matrix in GC and GC/MS by Using PTV Backflush Injection Technique for Increased Productivity and Reliability

Olga Shimelis, Katherine Stenerson, Michael Ye, Carmen T. Santasania, and Ed Mauney. Supelco, Div. of Sigma-Aldrich, Bellefonte, PA USA

A Direct Column-Performance Comparison for Rapid Contract Laboratory Program (CLP) Pesticide Analysis. Application. Authors. Abstract.

Summary results using G7000A GC-QQQ for OCPs, Pesticides and PCBs in Marine Sediment and Biota

Improving Your Analysis by Treating Your Flow Path with Agilent s NEW Ultra Inert Technology. Abby Folk GC Technical Support

New 7693 Autosampler and Multimode Inlet for Drinking Water Analysis

Technical Article. Innovative Chromatography Solutions. The Rtx -CLPesticides Column Set Lets You Make the Choice

Pesticide & Environmental Pollutant (P&EP) GC/MS/MS Analyzer 2.0

Nitrosamines Analysis in Drinking Water Using GC/MS/MS Meeting Equivalence to EPA Method 521

The Fast Track to Success. Pesticides Workflow Solutions for Intuvo GC/TQ

Improving Productivity in Your Environmental and Food Testing Labs with Agilent 7890A/5975C GC/MS System

Direct Injection of Fish Oil for the GC-ECD Analysis of PCBs: Results Using a Deans Switch With Backflushing. Application. Author.

Semivolatile Analysis with Specially Designed Agilent J&W DB-UI 8270D Columns

Prefractionator for Reliable Analysis of the Light Ends of Crude Oil and other Petroleum Fractions

Agilent Consumables Improve Performance with Shimadzu GC/MS

A Fast, Robust Approach to Measuring Pesticides and Mycotoxins in Dry Cannabis Flower and Concentrates

Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D7504 on the Agilent 8890 GC System

Analysis of Pesticide Residues in Lettuce Using a Modified QuEChERS Extraction Technique and Single Quadrupole GC/MS

7890A An Essential Partner for the Trace

Analyze more samples. faster. while maintaining resolution. NEW Agilent J&W High Efficiency Capillary GC Columns

ENVIRONMENTAL analysis

Validation Data for the Analysis of Chlorotalonil in Leek Using Mini-Luke Method Followed by GC-QqQ-MS/MS

AppNote 4/2006. Elimination of Non-Volatile Sample Matrix Components After GC Injection using a Thermal Desorber and Microvial Inserts KEYWORDS

AppNote 1/2009 KEYWORDS ABSTRACT. Disposable Pipette Extraction (DPX), QuEChERS, Automation, Pesticides

Ghost Peaks in Gas Chromatography Part 2: The Injection Port

Drinking Water Semivolatiles Analysis using the 6890N/5975B inert GC/MSD. Application. Author. Abstract. Instrument Operating Parameters.

Analysis of Polychlorinated Biphenyls and Chlorinated Pesticides by Gas Chromatography with Electron Capture Detection

Gas Chromatography Assignment Chem 543/443

Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph

GC Method Development

Extraction of a Full Suite of Semivolatile Compounds from Drinking Water using Automated Solid Phase Extraction

Liners and consumables for OPTIC Inlet. Liner Selection Guide

GC Method Developement

Determination of Pesticide Residue in Apple Juice Using the AutoMate-Q40

Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D*

A New Horizon of Performance Agilent G1888 Network Headspace Sampler

Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application

Interlaboratory Validation Study for the Analysis of Nitrosamines in Drinking Water using GC-MS/MS

Resolve Your Search for More Ions: The 5977B, 7000D, and 7010B GC/MS Instruments. Stephan Baumann ASTS Talk November, 2016

Multi-Residue Pesticide Analysis in Ginseng Powder: Optimized Cleanup After QuEChERS Extraction for UPLC-MS/MS And GC-MS/MS Analysis

DETERMINATION OF ORGANIC PRIORITY POLLUTANTS AND EMERGING COMPOUNDS IN WASTEWATER BY MICRO SOLID PHASE EXTRACTION COUPLED TO GCMS

AppNote 7/2010. GERSTEL Automated Liner Exchange (ALEX) and its Benefi ts in GC Pesticide Analysis KEYWORDS ABSTRACT INTRODUCTION

Automated Solid-Phase Extraction of Organochlorine Pesticides from Drinking Water. Pranathi R Perati Thermo Fisher Scientific, Sunnyvale, CA, USA

Tyler Trent, Applications Sales Specialist; Teledyne Tekmar Page 1

Determination of Monocrotophos, Diazinon, Malathion, EPN, and Methamidaphos from Aqueous Samples Using Atlantic HLB SPE Disks

The Use Of Automated Backflush on the 7890A/5975A GC-MS System. Application. Setup Example Using Biomarkers. Authors. Abstract.

Capillary Flow Technology: Backflush REDUCE RUN TIME AND INCREASE LABORATORY THROUGHPUT

Target and Non-target Pesticide Residue Analysis Using GC/QQQ and GC/Q-TOF with a Discussion on Ways to Use Sandwich Injections

Agilent Ultimate Plus Fused Silica Tubing

Pesticide Analysis in a Complex Matrix using a 2D GC/MS System

GC Method Developement. Simon Jones GC Application Engineer GC Columns and Consumables

Current and future trends in Pesticide Residue analysis. Jim Garvey

Robustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety

Validated Multi-Residue Method for Extraction and Analysis of Trace-Level Pesticides in Surface Water Application

GC-MS (Multi-Residue) Screening for Pesticides; Emerging Organic Pollutants (EOP's) and Persistent Organic Pollutants (POP's).

An Examination of the Presence, Formation, and Transformation of Volatile Halogenated Organic Species in Wastewater Extracts Using GC-ICP-MS

Improving GC Resolution and Dealing with Peak Tailing

Automated Solid-Phase Extraction of Organochlorine Pesticides from Drinking Water

Olefin Analyzer Solutions for Polymer Grade Ethylene and Propylene

CORESTA Recommended Method No. 57

Capillary GC Troubleshooting: a Practical Approach

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations

Analysis of EPA Method 8270D Semivolatiles Using the Agilent J&W DB-UI 8270D Ultra Inert GC Column

Multi-Residue Pesticide Methodologies. Frans Schoutsen

Analytical Method for aldrin, endrin and dieldrin (Targeted to Agricultural, Animal and Fishery Products)

Analysis of Drinking Waters for a Suite of Pesticides using GC with dual ECD (US EPA Method 508.1) after SPE Concentration

Content Page OPTIC Liners OPTIC 2 OPTIC 3 OPTIC-4 LINEX PHASER

Improved Gas Chromatograph Method for the Analysis of Trace Hydrocarbon Impurities in 1, 3-Butadiene

Standard Operation Procedure (SOP) for the Extraction and Instrument Analysis of Siloxanes from Cartridges

EVALUATION OF D DIFFERENT EXTRACTION METHODS OF PESTICIDE RESIDUES IN SPICES BY

Chromatography Applications and Technology

Determination of chemical contaminants in marine fish by GCMS/MS using QuEChERS as an extraction method

Liner Style* Function Advantages Disadvantages Recommended For Straight Low surface area for less activity Least expensive Low activity

Clarus SQ 8 GC/MS. The NEW

Confirmation of THC in Oral Fluids Using High-Resolution 2-D GC/MS Application Note

Application Note. Abstract. Authors. Food Safety

A Method for the Trace Analysis of 175 Pesticides Using the Agilent Triple Quadrupole GC/MS/MS

FOOD PESTICIDE RESIDUES LABORATORY REFERENCE NO INSPECTOR DATE

ENVIRONMENTAL ANALYSIS. Solutions for Your Analytical Business Markets and Applications Programs. Solution Note

CALA Directory of Laboratories

Transcription:

Methods for Increased Sample Throughput with Dirty Samples Alan D Broske, Limian Zhao, and William H. Wilson Agilent Technologies, Inc. 1

Introduction GC inlet liner impacts sample transfer to the GC column Limit matrix deposition in selected areas of the liner Matrix impurities decompose chemical deactivation Matrix impurities reach the analytical column Solution with liner design and deactivation that are unique for the type of injection Efficient spreading of matrix impurities over liner surface A more stable deactivation layer Use well deactivated glass wool to trap impurities Agilent s Ultra Inert liner deactivation process significantly improves the efficiency and robustness of the glass liner and glass wool deactivation Quantitative analysis of pesticides Reduced matrix interference 2

Liners Used Inlet liners used in this evaluation include Dimpled liner (2 mm ID) Single taper (4 mm ID) Single taper with wool (4 mm ID) Dimple (Agilent p/n 5192-2296) Single Taper (Agilent p/n 5192-2292) Single Taper with Wool (Agilent p/n 5192-2293) 3

Experimental Analysis of pesticides by GC/ECD Instrument conditions Agilent GC/ECD system, equipped with Agilent 7683B Autosampler Inlet: S/SL inlet using splitless mode @ 250 C, purge time at 0.75 min,1 μl injection volume Inlet liner: Ultra Inert single taper splitless liner (Agilent p/n 5190-2292) Carrier: He, constant flow, 0.9 ml/min (31 cm/sec) Column: HP-5ms UI, 15 m x 0.25 mm, 0.25 μm (Agilent p/n 19091S-431 UI) Oven: 120 C (1 min), 30 C/min to 220 C, 8 C/min to 280 C (1 min) ECD: 280 C, N makeup, constant column + makeup Sample Endin/DDT sample in MtBE 4

Experimental Analysis of pesticides by GC/MS/MS Instrument conditions Source @ 300 C, Quad (Q1 & Q2) @ 150 C Data acquisition: Agilent 7890A/7000 GC/MS/MS system, equipped with Agilent 7693 Autosampler Cold Injection: MMI inlet, splitless @ 60 C (0.1), 700 C/min to C300 C (19). Hot Injection: MMI inlet, splitless in pulsed splitless mode @ 280 C, purge flow 50 ml/min at 1 min, pulsed pressure 36 psi for 1 min 1 μl injection volume Inlet liner: Cold: 2 mm Dimpled liner (Agilent p/n 5190-2296) Hot: Ultra Inert single taper splitless liner with wool (Agilent p/n 5190-2293) Carrier: Cold: He, 10.68 psi, constant flow Hot: He, constant pressure, RT locked with Chlopyrifosmethyl @ 8.298 min 5

Experimental Analysis of pesticides by GC/MS/MS (continued) Instrument conditions Analytical column: HP-5ms UI, 15 m x 0.25 mm, 0.25 μm (Agilent p/n 19091-431 UI) Purged Ultimate Union (Agilent p/n G3182-61580) for backflushing Restrictor: Inert Fused Silica tubing, 0.65 m x 0.15 mm (Agilent p/n 160-7625-5) Oven profile: Cold: 60 C (1), 50 C/min to 150 C, then 16 C/min to 200 C, then 7 C/min to 300 C Hot: 100 C (2 min), 50 C/min to 150 C, 6 C/min to 200 C at 16 C/min to 280 C (6 min) Postrun backflush: 2 min @ 280 C, backflush pressure @ 75 psi, inlet pressure @ 1 psi during backflush MSD: Transfer line @ 280 C MRM 6

Experimental Analysis of pesticides by GC/MS/MS (continued) Sample Representative and active pesticides, 5 ng/ml to 500 ng/ml six points calibration standards, 50 ng/ml QC Matrix Sample Five different fruits and vegetables matrix mixture: flower, banana, strawberry, pear, and lettuce Blank matrices sample were extracted following QuEChERS AOAC method (sample extraction and following dispersive-spe clean up) Agilent Bond Elut QuEChERS AOAC extraction (Agilent p/n 5982-5755) and dispersive SPE kit for general fruits and vegetables (Agilent p/n 5982-5022) 7

Results and Discussion Ultra Inert liners are highly deactivated as evidenced by low endrin/ddt breakdown (Hot splitless/ecd) Endrin breakdown results from active sites on liner. DDT breakdown comes from the metal inlet parts. Multiple injections can decompose the liner deactivation and increase breakdown. 8

Results and Discussion Summary of pesticide breakdown on Ultra Inert and competitive liners after multiple injections Endrin Breakdown (%) DDT Breakdown (%) Injection 1 Injection 50 Injection 100 Injection 1 Injection 50 Injection 100 UI Lot 31 3.7 9.6 11.4 7.4 7.6 5.6 UI Lot 40 1.3 3.7 15.6 1.5 2.1 3.2 UI Lot 42 1.2 8.3 12.2 2.5 3.9 3.0 Vendor 2 11.4 15.5 33.8 3.1 3.9 5.2 Vendor 3 2.7 7.2 34.6 5.8 5.5 11.5 Ultra Inert liners show low breakdown even after 100 injections demonstrating high deactivation stability. Some competitive liners show high breakdown and short lifetime. 9

Results and Discussion Ultra Inert liners are highly deactivated as evidenced by high recoveries of pesticides (Hot splitless/ms/ms) MRM of 10 ng/ml pesticide sample 1. Methamidophos 2. Dichlorvos 3. Mevinphos 4. Acephate 5.?-Phenylphenol 6. Omenthoate 7. Dimenthoate 8. Altrazine 9. Lindane 10. Diazinon 11. Chlorothalonil 12. Chloropyrifos methyl 13. Vinclozolin 14. Carbaryl 15. Tolclofos methyl 16. Dichlorfluanid 17. Aldrin 18. Malathion 19. Dichlorobenzophenone 20. Pirimiphos ethyl 21. Tolyfluanid 22. Procymidone 23. Endrin 24. Ethion 25. Endosulfan sulfate 26. DDT 27. Endrin ketone 28. Iprodione 29. Phosmet 30. Phosalone 31. Permethrin isomers 32. Coumaphos 33. Deltamethrin isomers The liner to liner performance reproducibility was tested with replicates of six Ultra Inert liners with wool from three different pesticides applications. Groups of 12 pesticides were selected as representative analytes. 10

Results and Discussion Repeatability: RSD (%) for analytes RF values of 50 ng/ml standard injections Pesticides (peak #) In reagent solvent Ultra Inert liners w/ wool by 100 injections (# liners = 5) Ultra Inert liners w/ wool by 50 injections (# liners = 7) In fruits and vegetables QuEChERS extract Ultra Inert liners w/ wool by 100 injections (# liners = 7) Helix liners by 50 injections (# liners = 3) Methamidophos (1) 7.7 5.1 11.7 25.4 Acephate (4) 5.4 16.6 30.1 55.6 Omenthoate (6) 10.5 27.1 44.8 49.9 Chlorothalonil (11) 4.8 7.3 13.4 14.9 Chlorothalonil (11) 8.6 9.3 15.2 11.7 Carbaryl (14) 8.7 11.7 19.9 13.4 Dichlorfluanid (16) 5.3 6.3 11.8 3.9 Tolylfluanid (21) 7.3 7.3 13.4 5.7 Endrin (23) 6.6 3.2 6.0 2.7 Endosulfan sulfate (25) 7.7 9.5 14.1 10.5 DDT (26) 6.3 23.1 36.4 16.8 Endrin ketone (27) 7.3 9.3 14.2 9.4 Iprodione (28) 5.1 5.0 8.1 20.3 Phosmet (29) 6.9 15.4 27.2 16.3 Excellent liner to liner reproducibility achieved by Agilent Ultra Inert liners with wool. 11

Results and Discussion Ultra Inert liners with wool generate higher responses for active compounds Pesticides Agilent Ultra Inert liner with wool Helix liner Methamidophos Acephate Omenthoate Dimenthoate Dimpled liners are highly deactivated as evidenced by high recoveries of pesticides with more uniform sample spreading (Cold splitless/ms/ms). 12

Results and Discussion (continued) 50 Matrix Runs 100 Matrix Runs The inner diameter was reduced and flow path obstructed preventing matrix from reaching column. Sample directed to liner wall for more uniform spreading and longer lifetime. 13

Results and Discussion (continued) Calculated RSD for response factors of selected pesticides at 50 ppb. Performance goal is < 20%. Multiple liner lots shown (red is Helix liner). 14

Conclusion The Ultra Inert deactivation shows high stability and provides long lifetime Superior linearity for active pesticides with matrix impurities Consistent liner to liner (lot to lot) reproducibility Unique liner designs for temperature sensitive compounds with extended lifetimes Equivalent or superior to other equivalent liners or popular liners used in the demonstrated applications 15