j u n c k e r s i d e a l w i t h u n d e r f l o o r h e a t i n g

Similar documents
Solid Hardwood Flooring. Underfloor heating Sport

Most products will act differently when installed over an UFH system than when installed on a standard unheated subfloor.

SOLID HARDWOOD FLOORS INSTALLING WITH CLIPS

Underfloor Heating. BS8425 Code of Practice for Installation of Laminate Floorcoverings and the Code of Practice issued by the

Wooden suspended floors

A guide to the installation of Junckers 20.5mm, 22mm and 14mm clip system floors

Installation Engineered Flooring

Product Manual. Underfloor Heating (UK) Floor Construction. Industrial - Commercial - Domestic

Floating Floor Constructions

Heating. Product Selection Guide

Subfloor heating and cooling instructions for Hakwood flooring products Duoplank 20mm (¾ ) and Duoplank 15mm (⅝ )

Heating cables in concrete Concrete > 3 cm

UNDERFLOOR HEATING THE LEVELDEK SYSTEM LIVING AND SPORTS

DURABASE CI 1/5. Underlay mats for decoupling and waterproofing tiled flooring APPLICATIONS AND FUNCTION.

FEEL THE WARMTH INSIDE YOUR HOME. 8 Thermonet POS 2005.indd 1 8/12/06 13:05:38

INSTALLATION INSTRUCTIONS SINGLE ROOM

Bluethermal Underfloor Heating Mat

AmberMat. Installation Manual

On load-bearing floors with LK Slotted Board EPS 16

INSTALLATION MANUAL. Cable and mains connection junction boxes are not provided by us and should be obtained from your installing electrician.

DEVImat and DEVIflex Indoor Heating Applications DSVF DTIF DTIR DTCE

Premium Electric Underfloor Heating Mat

Ultra slim mats, only 3.5mm in height, ensure the ECmat is suitable for virtually any new build or renovation project.

Specification for Solid Timber Flooring Installation, Sanding and Coating

Accent Floor Heating. Tmat System Installation Manual. Floor heating system

FERMACELL DRY FLOORING ELEMENTS: IMPROVED LIVING CONDITIONS THROUGH BETTER ACOUSTIC AND THERMAL INSULATION. Dry Lining

Refurbishment site guidance for solid-walled houses ground floors

Electric underfloor heating solution for all stone and tile floors. Installation manual & guarantee

INSTALLATION INSTRUCTIONS FOR WICANDERS 5G-C FLOORS

18mm T&G Engineered Oak Fitting Guide & Warranty Information

INSTALLATION INSTRUCTIONS FOR WICANDERS 2G FLOORS

TECHNICAL BULLETIN TB029

Installation Manual. ThermMAT ThermCABLE FME. Technical Helpline:

The flooring comes complete with a 20 year structural warranty providing peace of mind, which most of our competitors cannot offer.

DURABASE CI. Underlay mats for decoupling and sealing tiled flooring 1/5 A P P L I C A T I ONS AND FUNCTION.

Installation Guide Mesh Floor Heating System

TECHNICAL BULLETIN TB029

INSTALLATION METHOD STATEMENT

MILLIMATTM - Underfloor heating mat

Nu-Heat UNDERFLOOR & RENEWABLES

Roth Compact system. German quality since Installation 1/6

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

R&M Floor Systems Compact:

Bavaria. PowerFloor. PhoneStar. SYSTEM SOLUT ions FOR TIMBER FRAME HOUSES AND REFURBISHMENTS DRY SCREED UNDERFLOOR HEATING SOUND INSULATION

September Saddle Flooring Systems

Specification for Engineered, Laminate and Bamboo Installation

APPLICATIONS AND FUNCTION:

Specification for Engineered, Laminate and Bamboo Installation

Preparation Products

Concrete 1,8 2,0 Anidrite 0,3 0,5

Timber subfloors. Concrete / screed subfloors. 1 SECTION 1 heatmat installation guide

SELF-ADHESIVE MEMBRANES

Rigid Core Installation & Maintenance Instructions

Installation Procedure of Floating floors

a new liquid screed solution

Indoor Heating Applications Mats and cables

CI/SfB (57.7) 2nd Edition. the warmth beneath your feet FREE NEXT DAY DELIVERY /0811

glue E Installation instructions General Acclimatization and storing conditions Subfloor

CI/SfB (57.7) 2nd Edition. the warmth beneath your feet FREE NEXT DAY DELIVERY /0811

SUBSTRATES FOR WOOD FLOOR SETTING

Installation instruction Danfoss Reflect - EFCI Dry

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

Electric Underfloor Heating EVERYTHING TO KNOW YOU NEED. Pocket Guide

SUPPORT - INSTALLATION ADVICE STEP1 - BEFORE YOUR FLOORING ARRIVES

The Unique Click System in Electric Floor Heating. Devidry - The Click System in Floor Heating

PROFILE SOLUTIONS FOR LED

INSTALLATION INSTRUCTIONS

Contents P/ 3. Ensuring Optimal Results P/ 4. Roof Insulation SF40 P/ 5. Roof Insulation Over Rafter Application P/ 6

a new liquid screed solution from

CADMAN SCREEDING & UNDERFLOOR HEATING SERVICES & FLOORING SYSTEMS GUIDE

LivingHeat THE UNDERFLOOR HEATING EXPERTS

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

ThermMAT. Please read these instructions in conjunction with the Guarantee Card enclosed with your ThermFloor heating system.

Installation Instructions. deviflex heating cables deviflex DTIP-8 and DTIP-10 for thin floors, wooden floors and frost protection of pipes

General and Installation Instructions Laminate - 2G + 2G

HEATING FLOOR TILE STONE HEATING FLOOR TILE STONE. Excellence in heating solutions. 1

Jabfloor 70, 100, 150, 200, 250

Existing Floors & Low Profile Systems

Please complete and display at your distribution board. Warning

Installation on underfloor heating

Flooré Produktion AB

15 days 75% Compressive Strength 1 day 23N/mm² 28 days 44N/mm²

Veria Quickmat 1C 100/150W/m²

Installation of Ecodure Bamboo or Ecodure Oak over particle board, plywood and existing timber floors

INSTALLATION INSTRUCTIONS

Solid Floor Systems. Underfloor heating for solid or screeded floors. Clip rail and staple system. Red Floor Panel

a new liquid screed solution from

Mapei systems for radiating floor heating with high thermal efficiency

R979SY011 SPIDER R979SY001 SPIDER R979SY021 SPIDER

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250

Jabfloor High Performance (HP) 70 and 100

acoustic insulation made from recycled rubber resilient, reliable and durable

EXP FOR TILE AND NATURAL TILE PROFILES. DURALIS-Stone FLORENTOSTEP-LED. DURALIS-LED Wall. DURALIS-LED Floor SQUARELIGHT-LED LED ACCESSORIES

Installation Guidelines: Magnolia

Tepidus Wire Installation instructions for Electric Radiant Floor Heating INDEX

INSTALLATION. The no mess, fast and easy, Peel & Stick flooring underlay and installation system... Quick Glance - Features and Benefits

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100

Transcription:

Since 1961, Junckers has installed more than 10 million square metres of hardwood flooring in the UK and Ireland alone. Often imitated but never bettered, Junckers expertise stems from a unique heritage of producing high quality solid flooring solutions. The combination of excellent craftsmanship and cutting edge design gives our extensive product portfolio a pedigree unmatched elsewhere. If you would like more information concerning our products, advice on installation and maintenance, please call us on UK: 01376 534700, Ireland: 1 800 523 138. Alternatively, visit www.junckers.co.uk j u n c k e r s i d e a l w i t h u n d e r f l o o r h e a t i n g MBR00420202/03.10/3.000

j u n c k e r s s o l i d w o o d e n f l o o r s t h e k e y t o a c o m f o r t a b l e i n d o o r c l i m a t e Today, underfloor heating is more popular than ever before. This is because it is not only a comfortable solution to home heating, but also because it is increasingly cost-effective. Modern buildings are very well insulated, and this means that underfloor heating systems can maintain a comfortable indoor climate while operating at lower temperatures. Wood has a natural innate warmth, and unlike most tiles and ceramics it is warm and comfortable whether the heating system is switched on or off. This makes Junckers solid hardwood flooring the ideal surface for underfloor heating. c o n t r o l l i n g & p l a n n i n g Oak Stripboard Jatoba Stripboard Merbau Stripboard Ash

j u n c k e r s a n d u n d e r f l o o r h e a t i n g There is more than 75 years experience and expertise Junckers batten systems can also be used in conjunction with underfloor heating systems. in a Junckers floor. Here are some of the factors that make Junckers the preferred choice for the installation of underfloor heating systems. Junckers flooring is adaptable and can be installed in almost any setting, and adjusted to most underfloor Junckers floors are firm and stable due to the controlled low moisture content of our pre-finished floor- electric or hot water systems. heating systems. Junckers floors are suited to both boards. Junckers wood strip floors are available in 14 and 22 All our products are tested with the leading manufacturers of underfloor heating systems. 20.5 mm thicknesses while wide boards are available in mm. f l o o r h e a t i n g Junckers flooring is suitable for installation in both new buildings and renovation projects. Junckers unique clip system allows boards to be swiftly fitted directly onto screeded subfloors containing underfloor heating pipes. Nordic Beech Stripboard Oak Stripboard Black Oak Wide Board

Oak

i n s t a l l i n g o n e l e c t r i c h e a t i n g s y s t e m s Installing a floor on electric heating systems adds little to the overall height of the floor. This makes installation easy and ideal for renovation projects. Typically the electrical mat is encased within a 6 mm layer of a cementitious material onto which the Junckers floor is fitted. This gives a total height of only 10 mm for the heating system. i n s t a l l i n g Where the height of the floor is less of an issue, electric heating cables are covered with a 30 mm layer of screed onto which the floor can be fitted. Wood floor with electric heating on existing concrete floor In both cases the Junckers floors are fitted using the unique clip system as a floating floor. The heat cable mats should have a maximum output of 100 W/m ². Wiring of the electric systems to an electric thermostat or other installations should only be undertaken by an authorised electrician. Water based system with heating pipes encased in concrete i n s t a l l i n g o n h o t w a t e r s y s t e m s The most common form of underfloor heating uses hot water pipes either contained within a screed or polystyrene insulation, or installed within a batten construction. The Junckers floating clip system is used over screeded or polystyrene bases whereas with batten systems the Junckers boards are secretly nailed. Water based system with heating pipes and heat distribution plates within flooring grade polystyrene Floor heating systems using hot water are fitted with automatic room sensors. These detect temperature increases caused by direct sunlight or other heat sources, which are then balanced by the thermostat. The water-based system should always be tested for pressure before connection, and should be connected only by an authorised plumber. Water based system with heating pipes and heat distribution plates on batten construction

c o n t r o l l i n g h e a t d i s t r i b u t i o n As hardwood expands and contracts with changes in moisture content, it is important that both electrical and hot water systems create an even heat distribution across the entire floor, as well as a controlled surface temperature on the surface of the board of no more than 27 degrees C. With water based systems involving battens, heat distribution plates are used to ensure this even heat distribution. Cardboard insulation (500 g/m ² ) is fitted between the distribution plates and the floorboards to avoid noise caused by any movement between them. Systems contained within polystyrene also use heat distribution plates. The insulation material used must have a density of 30 kg/m 3 or more. compound. There are some heating systems where this is not a requirement, please consult Junckers Technical Department for further advice. In electric heating systems, a thermostat with floor sensors is fitted to ensure that the maximum surface temperature doesn t exceed 27 degrees C. The sensor is fitted in the screed inside a plastic pipe. The temperature should always be adjusted slowly in order to allow the wood to naturally expand or contract. It is quite normal to see slight gaps between the floorboards in the heating season. However these gaps will close in the summer months. In general, electrical under floor heating systems are embedded within a floor screed or if placed over a sub-floor, then covered with a suitable levelling p l a n n i n g i n s t a l l a t i o n Installation of Junckers floors should proceed when the temperature and relative humidity of the building resembles the expected future climatic conditions, for instance 35-65%RH. The heating system must have been in operation for an adequate period of time before the floor is laid. During this time the room should be ventilated regularly. Note: If glueing the Junckers boards down to a screed containing underfloor heating, the moisture content of the subfloor must not exceed 65%RH. For more detailed information consult the Junckers Technical Information sheets E4.0, E4.1, E4.2 and E4.3. On screeded subfloors containing hot water pipes or electrical cables, the Junckers floor is usually installed with Junckers unique clip system. A 1000g moisture membrane is needed in addition to the Junckers Polylay underlay. It is important to ensure that the moisture content of the screed is no more than 75%RH.