Effect of lintel on horizontal load-carrying capacity in post-beam structure

Similar documents
Joint Design of Precast Concrete Moment Frame using Hollow Precast Concrete Column Soo-Yeon Seo, Tae-Wan Kim, Jong-Wook Lim, Jae-Yup Kim

Compression Test for Precast Encased Composite Columns with Corrugated Steel Tube

CTBUH Technical Paper

Cyclic Loading Tests Of Steel Dampers Utilizing Flexure-Analogy of Deformation

An Experimental Study on the Effect of Opening on Confined Masonry Wall under Cyclic Lateral Loading

Finite Element Analysis of Thin Steel Plate Shear Walls

D. Y. Abebe 1, J. W. Kim 2, and J. H. Choi 3

Hybrid-steel concrete connections under reversed cyclic loadings

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

SEISMIC ENERGY DISSIPATION SYSTEM OF 12-STOREY COUPLED SHEAR WALLS

Progressive Collapse Resisting Capacity of Moment Frames with Infill Steel Panels

In-plane testing of precast concrete wall panels with grouted sleeve

EXPERIMENTAL INVESTIGATION OF PRECAST CONCRETE BEAM TO COLUMN CONNECTIONS SUBJECTED TO REVERSED CYCLIC LOADS

SHEAR STRENGTH CAPACITY OF PRESTRESSED CONCRETE BEAM- COLUMN JOINT FOCUSING ON TENDON ANCHORAGE LOCATION

Effect of beam dimensions on structural performance of wide beam-column joints

Field Load Testing of the First Vehicular Timber Bridge in Korea

Seismic Collapsing Response Analysis of Wooden House Retrofitted by ACM Braces

INHERENT DUCTILITY OF REINFORCED CONCRETE SHEAR WALLS WITH NON-SEISMIC DETAILING

Masonry infills with window openings and influence on reinforced concrete frame constructions

Seismic Assessment of Traditional Masonry-Wooden Building in Taiwan

WIRE-ROPE BRACING SYSTEM WITH ELASTO-PLASTIC DAMPERS FOR SEISMIC RESPONSE REDUCTION OF STEEL FRAMES

CYCLIC BEHAVIOR OF AN INNOVATIVE STEEL SHEAR WALL SYSTEM

Seismic Collapsing Process Analysis of One-story Thatched Roof Wooden Structure under Strong Earthquake Ground Motion

Axial Load Behaviors of PSRC Composite Columns with Anchor-Type Transverse Reinforcements

Cyclic Loading Test for Reinforced Concrete Frame with Thin Steel Infill Plate

Development of a New Type of Earthquake Energy-absorption Device

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET

A Comparative Study on Non-Linear Analysis of Frame with and without Structural Wall System

PRECAST PRESTRESSED PORTAL FRAMES WITH CORRUGATED STEEL PANEL DAMPERS

Experimental Study on the Behaviour of Plastered Confined Masonry Wall under Lateral Cyclic Load

THE DESIGN AND INSTALLATION OF A FIVE-STORY NEW TIMBER BUILDING IN JAPAN

Structural characteristics of column with precast wing walls as energy absorption elements

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE COLUMNS UNDER CONSTANT AND VARIABLE AXIAL LOADINGS

SEISMIC COLLAPSING BEHAVIOUR OF ONE-STORY WOODEN STRUCTURE WITH THATCHED ROOF UNDER STRONG EARTHQUAKE GROUND MOTION

Beam-column joint tests with grade 500E reinforcing

Experimental Evaluation of The Seismic Behavior of Steel- Braced RC Frames

Improving Seismic Performance of Steel Knee Braced Frame Structures

Basic quantities of earthquake engineering. Strength Stiffness - Ductility

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

SEISMIC BEHAVIOR OF HYBRID SYSTEM WITH CORRUGATED STEEL SHEAR PANEL AND RC FRAME

Literature Review of Wood-frame Structure Tests

Investigation of the behavior of stiffened steel plate shear walls with Finite element method

GRAVITY LOAD COLLAPSE OF REINFORCED CONCRETE COLUMNS WITH DECREASED AXIAL LOAD

Seismic behaviour of HSC beam-column joints with high-yield strength steel reinforcement

Seismic Performance Evaluation based on Static Loading Tests of Timber Frame Structures with Large Hanging Walls and Full Walls

EXPERIMENTAL STUDY ON HYSTERETIC DAMPER WITH LOW YIELD STRENGTH STEEL UNDER DYNAMIC LOADING

SEISMIC EXPERIMENTAL RESEARCH OF CONCRETE FILLED STEEL TUBE COLUMNS-CONCRETE COMPOSITE SHEAR WALL

STRUCTURAL PERFORMANCE OF MIXED MEMBER COMPOSED OF STEEL REINFORCED CONCRETE AND REINFORCED CONCRETE

Pushover Analysis of RC Bare Frame: Performance Comparison between Ductile and Non-ductile detailing

EFFECTS OF AXIAL FORCE ON DEFORMATION CAPACITY OF STEEL ENCASED REINFORCED CONCRETE BEAM-COLUMNS

Collapsing Simulation of Wooden House Retrofitted by ACM Braces During Seismic Ground Motion

SHEAR BEHAVIOR OF MULTI-STORY RC STRUCTURAL WALLS WITH ECCENTRIC OPENINGS

Truss Analysis for Evaluating the Behavior of Reinforced Concrete Moment-Resisting Frames with Poorly Reinforcing Details

EVALUATION OF RESPONSE REDUCTION FACTOR OF RC FRAMED BUILDINGS BY PUSHOVER ANALYSIS

By Alejandro Amaris, Stefano Pampanin, Des Bull, Athol Carr.

Experimental study on the seismic performance of RC moment resisting frames with precast-prestressed floor units.

Effective Length of RC Column with Spandrel Wall

A Performance Based Evaluation of a Wall- Frame Structure Employing the Pushover Analysis Tool

STUDY ON SEISMIC BEHAVIOR OF RECYCLED CONCRETE FRAME JOINTS UNDER LOW CYCLIC LOAD

Seismic Behavior of Composite Shear Wall Systems and Application of Smart Structures Technology

CHAPTER 5 BEHAVIOUR OF BEAM-COLUMN JOINT UNDER CYCLIC LOADING

Behavior of Segmental Precast Post-Tensioned Bridge Pier

Analysis and Design of Hollow Reinforced Concrete Columns

Effective Beam Width for Flat Plate Systems with Edge Beams

Bi-axial Bending Behavior of RHS-columns Including Post-buckling and Deterioration Range

Structural performance of a full-scale reinforced concrete frame strengthened by a steel grid shear wall

Experimental research on reduced beam section to concrete-filled steel tubular column joints with RC slab

OPTIMAL SEISMIC DESIGN METHOD TO INDUCE THE BEAM-HINGING MECHANISM IN REINFORCED CONCRETE FRAMES

Comparative Study of X-Concentrically Braced Frame, Zipper Frame and Strong Back System

Damage Assessment of Reinforced Concrete Columns Under High Axial Loading

ctbuh.org/papers Evaluation of Progressive Collapse Resisting Capacity of Tall Buildings Title:

EXPERIMENTAL STUDY ON THE EVALUATION OF THE EARTHQUAKE RESISTANT PERFORMANCE OF MUD-PLASTERED WALLS

OPTIMUM LOCATION OF RC SHEAR WALL FOR A FIVE STOREY SYMMETRICAL FRAMED STRUCTURE FOR EFFICIENT SEISMIC DESIGN USING PUSHOVER ANALYSIS

Experimental study on seismic behavior of composite concrete and

Southeast University, Nanjing, Jiangsu , China. *Corresponding author

Experimental Study on Wall-Frame Connection of Confined Masonry Wall

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE CORE WALL

Seismic Performance of Multistorey Building with Soft Storey at Different Level with RC Shear Wall

Cold-Formed Steel Special Bolted Moment Frames: Capacity Design Requirements

Experimental Study of a New Steel Shear Wall with an Embedded Special Damping Mechanism (SSWAF)

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

SHAKING TABLE TEST USING MULTIPURPOSE TEST BED

Hybrid System Using Precast Prestressed Frame with Corrugated Steel Panel Damper

CYCLIC TESTING OF BOLTED CONTINUOUS I-BEAM-TO-HOLLOW SECTION COLUMN CONNECTIONS

ELASTIC-PLASTIC BEHAVIOR OF REINFORCED CONCRETE COLUMN-STEEL BEAM JOINTS UNDER BI-DIRECTIONAL LOADING

Mechanical behavior and design method of weld-free steel structure with knee brace damper using square tube column

1337. Seismic response of beam-column joints rehabilitated with FRP sheets and buckling restrained braces

Evaluation of Seismic Behavior for Low-Rise RC Moment Resisting Frame with Masonry Infill Walls

Experimental Study to Strengthen Two-story Brick Buildings with Precast Floor Slabs

Cold-formed Steel Special Bolted Moment Frames Capacity Design Requirements

SEISMIC PERFORMANCE OF FLAT-SLAB SHEAR REINFORCEMENT

PERFORMANCE OF EXTERIOR PRECAST UNDER CYCLIC LOADING. R. Vidjeapriya & K.P. Jaya Anna University, Chennai , India 1.

EXPRIMENTAL AND ANALYTICAL STUDY ON SEISMIC BEHAVIOR OF TRADITIONAL WOODEN FRAMES CONSIDERING HORIZONTAL DIAPHRAGM DEFORMATION AND COLUMN SLIPPAGE

Design Method of Steel Plate Shear Wall with Slits Considering Energy Dissipation

Pile to Slab Bridge Connections

COMPARATIVE ANALYSIS OF SEISMIC ISOLATED SYSTEMS IN BRIDGES

composite elements, lateral loads, strain analysis, behavior Composite steel concrete elements made by steel and concrete are used in world wide almos

VERIFICATION OF A REINFORCED CONCRETE COLUMN COMPUTER MODEL UNDER UNIAXIAL AND BIAXIAL BENDING LOADING CONDITIONS

The cracking behaviour of reinforced concrete beams under static and dynamic loading

Transcription:

J Wood Sci (2014) 60:30 38 DOI 10.1007/s10086-013-1371-1 ORIGINAL ARTICLE Effect of lintel on horizontal load-carrying capacity in post-beam structure Chun-Young Park HyungKun Kim Chang-Deuk Eom Gwang-Chul Kim Jun-Jae Lee Received: 20 December 2012 / Accepted: 29 July 2013 / Published online: 5 November 2013 Ó The Japan Wood Research Society 2013 Abstract This study is aimed to evaluate whether lintel has structural effect because it has not been categorized as a structural member. This study experimentally evaluated the horizontal load-carrying capacity of post-beam timber frame structures with bi-linear model and energy dissipation mechanism. To evaluate the effect on horizontal performance of lintel which has been widely used as wall frame in Korean traditional post-beam structure, two frames were tested in different types. One had no lintel and the other one had lintel at the height of 800 mm, respectively. Cyclic loading tests were conducted for each frame according to the standard loading protocol. Frame which had lintel showed slightly higher stiffness. And it showed noticeably significant energy dissipation performance after yield point of the joint. And that leads to the conclusion that lintel has structural effect and it should be considered Part of this paper has been presented at the world conference on timber engineering (WCTE 2012), Auckland, New Zealand, July, 2012. C.-Y. Park G.-C. Kim Department of Forest Sciences, Chon-Buk National University, Seoul 151-921, Korea H. Kim Department of Forest Sciences, Seoul National University, Seoul 151-921, Korea C.-D. Eom Korea Forest Research Institute, Seoul 130-712, Korea J.-J. Lee (&) Department of Forest Sciences, Research Institute for Agriculture and Life Sciences, College of Agriculture and Life Sciences, Seoul National University, Seoul 151-921, Korea e-mail: junjae@snu.ac.kr as an important factor when evaluating horizontal performance of the structure after yield point of the joint. Keywords Post-beam structure Horizontal load-carrying capacity Energy dissipation Dovetail joint Introduction Timber structures have been shown significant horizontal shear performance in historical earthquake. Extensive studies have been conducted on horizontal load-carrying capacity of light framed houses throughout North America and Europe and post-beam structures in East Asian region. Han-ok which means Korean traditional building is categorized into post-beam structures. As well as its beautiful appearance, its structural performance has been an issue. However, it was not easy to calculate structural stability because Han-ok has been built by own hands of craftsman and not by machine. In this reason, most Han-oks have been over designed and caused wasting of expensive wood members. There have been various approaches to evaluate structural performance of Han-ok. Many researchers have thought that most of the structural performance came from the joint. Therefore, most of the study about Han-ok is concentrated on the joint performance. Some of the studies were conducted on the traditional frame but there were no consideration about lintel. Recently, lintel has been drawing attention in reinforced concrete construction. And it is also a very important member for infilling wall in traditional and modern Han-ok. Yu [1] conducted the research about the traditional wooden joint in Han-ok. All kinds of traditional joints

J Wood Sci (2014) 60:30 38 31 were organized based on their shape and location. But, it was limited to the categorization of the joints and there was no consideration about their performance. Han [2] investigated mechanical performance of mortise-tenon joint. Series of experiments were conducted and optimum size of the mortise-tenon joint was determined. Similar test was conducted by Han [3] about the size effect of the mortise-tenon joint. Joint performance was evaluated under consideration of wood properties. Pang et al. [4] evaluated the moment-carrying capacity of dovetail joints in traditional Korean wooden buildings. Yet, it was limited to the joint. In 1999, Seo et al. [5] started to conduct traditional frame test under lateral loading. Lateral yield strength of timber post-beam structure with different joints was analysed. As a result, joint performance was emphasized. Another test was conducted by Hwang et al. [6]. Horizontal shear test was conducted to evaluate the horizontal shear performance of the post and beam wood wall. They are similar tests, but did not consider the effect of the lintel and the vertical load. Research about the lintel is scarce because lintel has not been considered as a structural member in construction field. Recently, Lee and Oh [7] conducted a static experiment to evaluate the seismic performance of a two-story reinforced concrete (RC) shear wall system. As a result, it was shown that the specimen with a lintel beam underwent the seismic performance with an ultimate strength and ductility capacity better than the specimen without a lintel beam. Among all of the members, lintel has been overlooked for its structural performance. Figure 1 shows middle and bottom lintels which are installed in Han-ok. Lintel is a horizontal member which is used as wall frame and it has been categorized as non-structural member without any experimental background. Therefore, this study is aimed to investigate the effect of lintel on structural performance in post-beam structure and, furthermore, to investigate seismic performance using cyclic loading test. Materials and methods Specimens Glulam using Japanese Larch (Larix leptolepis) was prepared for full-scale test. Moisture content of each lamination was below 13.16 ± 1.32 % and the grade of Glulam was 10S30B by Korean Standard (KS). Size of specimens was 180 9 180 9 2400 (mm) for the post, 180 9 240 9 3420 (mm) for the beam and 180 9 180 9 3420 (mm) for the lintel. The beam was assembled on the top of posts with dovetail joint. After all, the frame had total width of 3780 (mm) which was 3600 (mm) from the middle to the middle of two posts and height of 2400 (mm). Dovetail joint was chosen to imitate Korean traditional joint and cut by Pre-Cut machine (K2, Hundegger). A detailed view of the joint is presented in Fig. 2. Cyclic loading test Structure 1 was constructed with two posts and a beam, Structure 2 had same composition as Structure 1 with lintel Fig. 1 Middle and bottom lintel in Han-ok Fig. 2 Detail of dovetail joint

32 J Wood Sci (2014) 60:30 38 Fig. 3 Test setup of frames

J Wood Sci (2014) 60:30 38 33 Fig. 4 Loading procedure Table 1 Detail of loading procedure Drift angle (rad) Frequency (Hz) Cycle number 0.0025 0.043668 3 0.005 0.021834 3 0.010 0.010917 3 0.015 0.007278 3 0.020 0.005459 3 0.025 0.004367 3 0.030 0.003639 3 0.040 0.002729 3 Failure 1 in the height of 800 mm from the bottom. Details of the test specimen are presented in Fig. 3. Cyclic loading test had been conducted for those two frames. Cyclic load was applied on the left upper corner of the frame according to the loading procedure shown in Fig. 4. Loading speed and maximum displacement were 1 mm/s and ±100 mm, respectively. Using 6 LVDTs and computer data acquisition system, displacements of each part were obtained. Supporting condition was assumed to be hinge support. A pin which has a diameter of 18 mm was inserted to the post at the height of 210 mm from the bottom steel plate. Details of loading procedure for each cycle are shown in Table 1. Fig. 5 Method details for calculating strength properties

34 J Wood Sci (2014) 60:30 38 Han-ok has beautiful, yet significantly heavy roof. This weight of the roof is delivered to rafter and then distributed to beams and upper parts of the posts uniformly. To calculate the roof load delivered to unit frame, standard Hanok was selected. Unit roof load was calculated according to KBC (Korean Building Code 2009) and the value was 36 kn. And simulated vertical load was applied on the frame using 18 hydraulic cylinders. As a result, the test setup was shown in Fig. 3. Evaluation methods Fig. 6 Concept of energy dissipation Vertical load Strength properties were calculated using bi-linear method regulated by Architectural Institute of Japan (AIJ). Structural characteristic factor (D s -Eq. 1) which decides seismic performance of the frame can be calculated by using ductility factor (l) which means that the ratio between the beginning point (h v ) and the finishing point (h u ) of the ultimate load (P u ) is based on the Plasto-Elasticity model. Other structural characteristic values in elastic range are shown in Fig. 5. This is the method which evaluates the behaviour of the structure distinguishing the plastic region from the elastic region. And it is suitable to calculate Fig. 7 Calculation procedure of energy dissipation (a experimental raw data, b selected one cycle, c calculation of the energy dissipation of the third cycle of one hysteresis curve)

J Wood Sci (2014) 60:30 38 35 Fig. 8 Hysteresis curves of structures Fig. 9 Strain softening allowable shear stress of the frame considering low initial stiffness and large deformation of wooden dovetail joint that exists in traditional timber structures [8 11] pffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi D s ¼ 1= ð2l 1Þ ð1þ Energy dissipation is defined as the energy dispersed in structural system against the external load and it determines the seismic performance of the structural frame which is used as very critical factor in seismic design along with the response modification factor. Energy dissipation can be evaluated by calculating the inner area of the hysteresis loop (Fig. 6). In general, energy dissipation should be calculated at the point that the story-drift ratio reaches 3.5 % [12, 13]. And this corresponds to the point between the 7th and 8th cycle in this study. However, experiment of Structure 2 which had lintel was not completed to reach this cycle for safety reason, so energy dissipation of the 6th cycle was compared. Third cycle of each hysteresis curve was selected and simplified to calculate the inner area. Then displacement was separated into differential length (dx) to apply a mensuration of division as shown in Fig. 7. Result and discussion Hysteresis curve Figure 8 shows hysteresis curves of two structures. The two structures show similar shape of hysteresis curves. They yielded after 3rd cycle and lost most of their stiffness. However, unlikely to the Structure 1, strength of the Structure 2 increased slightly after yield point. And also, Structure 2 does not show dramatic decrease in strength

36 J Wood Sci (2014) 60:30 38 Table 2 Strength properties F y (N) h y (rad) K (N/rad) F max (N) h max (rad) F u (N) Structure 1 1202 0.002 551638 1639 0.013 1390 Structure 2 1074 0.004 355808 1890 0.017 1262 h u (rad) h v (rad) S (N rad) l D s P 120 (N) Structure 1 0.034 0.003 49.704 13.680 0.190 1458 Structure 2 0.022 0.005 31.763 5.010 0.339 1390 F y yield force, h y yield drift angle, K initial stiffness, F max maximum force, h max drift angle in F max, F u ultimate force, h u Drift angle in F u, h v beginning drift angle of plastic behaviour, S energy of plasto-elastic behaviour, l ductility factor, D s structural characteristic factor, P 120 load in drift angle 1/120 after yielding. This result means that lintel has structural effect after yield point. Hysteresis curve shows similar behaviour with that of common post-beam frame, strain softening which means decreasing horizontal load as frame is subjected to repeated load (Fig. 9). It was shown that stress was consistently decreasing throughout 1st to 3rd cycle in Structure 1. On the other hand, there was significant decrease at second cycle in Structure 2, yet the total decrease was about the same with the Structure 1. Strength properties Lintel has been considered as a non-structural member so far. From the result of the experiment (Table 2), there was no significant structural difference according to a lintel in elastic region, yet even higher structural performance was observed when there was no lintel [yield force (F y ), yield drift angle (h y ), Initial stiffness (K)]. However, for the plastic region, ductility factor (l) and structural characteristics factor increased when the lintel was installed. That means there was large deformation in plastic region and it could be the effect on the safety of structure. Energy dissipation Energy dissipation performance of each frame was evaluated by calculating the inner area of the hysteresis curve. And the energy dissipation was calculated at stages in third cycle of the whole hysteresis curve (Fig. 10). Structure 1 which was composed of two posts and beam showed 1355 (N rad) of energy dissipation throughout 6 cycle of loading. On the other hand, Structure 2 which had Fig. 10 Energy dissipation performance

J Wood Sci (2014) 60:30 38 37 lintel showed 2483 (N rad) throughout same cycle. And the difference of value was significant after third cycle when the joint started to yield. Comparison of the energy dissipation performance is shown in Table 3. As similar to the l, ductility factor, energy dissipation performance is one of the critical factors when conducting seismic design. Lintel proved that it could absorb or transform dynamic energy into other form of energy when it was subjected to cyclic loading. Especially, it is clearly confirmed by accumulative dissipation. Effect of lintel was confirmed by the bearing line on the post member after the experiment. But the bearing surface and depth are not significant because lintel had effect in latter part of the behaviour and not on the initial part. In other words, there was no significant effect of lintel on energy dissipation before yielding point because there was slight gap between the post and the lintel joint. Even though this gap was small, there was no significant interior deformation in the lintel joint because the story drift of the lintel level was shown to be only 33.3 % of the top beam. Table 3 Energy dissipation for each cycle and accumulation Cycle Structure 1 Structure 2 Energy dissipation (N rad) Cumulative value (N rad) Energy dissipation (N rad) Cumulative value (N rad) 1 35 35 26 26 2 159 194 122 149 3 410 605 434 584 4 709 1314 895 1479 5 1030 2345 1579 3059 6 1355 3701 2483 5542 7 1738 5439 8 2351 7790 Total 7787 5539 Fig. 11 Bearing area in post-lintel joint However, bearing occurred on the top and the bottom of the lintel joint as the deformation increased more than the gap of the joint after yield point. And the bearing was developed to surface contact from point contact after yield point. It is shown in Fig. 11. It is considered that this changing form of contact caused by inner deformation in lintel joint had dedicated to the enhanced energy dissipation performance. Conclusions Structural effect of lintel which has been overlooked was evaluated from the experiment. Following conclusions can be drawn from the present study: It is verified that lintel had structural effect when it is subjected to cyclic loading. Lintel has no significant effect in initial elastic region but, shows structural effect in plastic region. Lintel shows significant energy dissipating performance after yield point. Applying lintel to structure can be an effective way to enhance seismic performance of structures. Bearing occurred between post and lintel throughout the whole behaviour is the reason for increasing of energy dissipation. Acknowledgments This paper was supported by research funds of Chon-buk National University in 2012. References 1. Yu SH (1988) Study about jointing of Korea wooden structure. Master s Thesis Paper, Korea University 2. Han JS (2005) An experimental study on mechanical performance of column and girder joint system for analysis on structural system and modernization on traditional of wooden architecture. J Korean Constr 21(11):195 206 3. Han SR (2006) Evaluation of the mechanical performance of various types of column and girder joint in Korean traditional wooden building. Master s Thesis Paper 4. Pang SJ, Oh JK, Park JS, Park CY, Lee JJ (2011) Momentcarrying capacity of dovetailed mortise and tenon joints with or without beam shoulder. J Struct Eng 137(7):785 789 5. Seo JM, Choi IK, Lee JR (1999) Static and cyclic behaviour of wooden frames with tenon joints under lateral load. J Struct Eng 125(3):344 349 6. Hwang KH, Park JS, Park MJ (2007) Horizontal shear performance of pre-cut post and beam wall applying traditional wood system. J Korean Constr 27(1):301 304 7. Lee SH, Oh SH (2010) Static experiment for the seismic performance of a 2 story RC shear wall system. J Korean Seism Eng 14:55 65 8. Richard N, Yasumura M, Davenne L (2003) Prediction of seismic behaviour of wood-framed shear walls with openings by pseudodynamic test and FE model. J Wood Sci 49:145 151

38 J Wood Sci (2014) 60:30 38 9. Oshiumi S (2000) Testing and evaluation method for the elements in post and beam structures (in Japanese). Kenchiku Gijutsu 608:174 179 10. Sawata K, Yasumura M (2003) Estimation of yield and ultimate strength of bolted timber joints by nonlinear analysis and yield theory. J Wood Sci 49(4):383 391 11. Gatto K, Uang C (2003) Effect of loading protocol on the cyclic response of woodframe shears. J Struct Eng 129(10):1384 1392 12. Choi HK, Yoo CH, Choi YC, Choi CS (2010) Structural capacity evaluation of hybrid precast concrete beam-column connection subjected to cyclic loading. J Korea Concr Inst 22(3):325 333 13. ACI T1.1R-01 (2002) Commentary of acceptance criteria for moment frames based on structural testing. ACI Manual of Concrete Practice. American Concrete Institute:1 7