EU type examination for ETN-lift buffers

Similar documents
Diaphragm seal with threaded connection Threaded design Model

European Technical Assessment. ETA-18/0083 of Member of. General part

1.0 INTRODUCTION GENERAL SUPPLIER S RESPONSIBILITY CODES AND STANDARDS... 4

Installation in ceilings

2-Finger-Parallel-Gripper RH

Presented By. NicolScales.com Contact Us

Technical Data Sheet. Cellular Buffers CONTENTS. Order number 018xxxx-xxxY

European Technical Assessment. ETA-11/0135 of Member of. General part

European Technical Assessment. ETA-15/0540 of Member of. General part

Glycerine filled Bourdon tube pressure gauges EN 837-1

HST -B Interlocking device (Translation of Original Manual)

Technical Data Sheet StoCrete BE Haftbrücke

National technical approval Coupler

Standard Bourdon tube pressure gauges EN 837-1

European Technical Assessment ETA-10/0067 of

Z5351 E8 Horizontal bracket Mounting instructions (1.1 EN)

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

Diaphragm seal with flange connection With internal diaphragm, threaded design Model , large working volume

Declaration of Performance (DOP)

Z5378 E6 Horizontal bracket Mounting instructions (1.0 EN)

DECLARATION OF PERFORMANCE

THE COMPLETE POLYETHYLENE INSULATION PACKAGE FOR EFFECTIVE ENERGY SAVING AND ACOUSTIC PROTECTION

Fire Protection Valves

Instructions for installation and use PFEIFER LSV Lifting Loop

Presented By. NicolScales.com Contact Us

Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

Diaphragm seal with flange connection Cell-type with extended diaphragm Model

T Z M r o d ( f u l l y w o r k e d ) PS- I H R 1 0 1

Declaration of Performance (DOP)

The Pressure Equipment Directive 2014/68/EU. Photo: nostal6ie/ Shutterstock

Diaphragm seal with flange connection With internal diaphragm Model

Z5010 (Version 2) TV spigot with fixing plate Mounting instructions

Load cell Pendeo Process and mounting kits

Process Inline Filter, Change-Over

COMBISAFE Multibox 9541 Multibox End Panel USER INSTRUCTIONS _001

THE PROFESSIONAL HIGH PERFORMANCE INSULATION FOR LONG TERM ENERGY SAVING TRUSTED SINCE 40 YEARS

iglidur A180 FDA-general purpose waterproof material

iglidur Low water absorption

Technical data Housing material &URTHERôVERSIONSôONôREQUEST

Technical features overview

DECLARATION OF PERFORMANCE

VN Series Floor Scale Instruction Manual

Technical Data Sheet StoCrete RM F

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

CHECK LINE. Operating Instructions BY ELECTROMATIC STM-50

Technical Data Sheet StoCrete TG 252

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSHY (HY R-4E) Resistance thermometer for the food and beverage industries

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Diaphragm pressure gauge per EN 837-3,

EEC-DECLARATION OF CONFORMITY

Field case for temperature transmitter Model TIF11


DECLARATION OF PERFORMANCE. No EN

3-Jaw insertion gripper UFG 66

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Welding and Solder Flange

2-finger angular gripper SGB 32-50

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Diaphragm pressure gauge

Translation of the original instructions. Type: PR 8-20

Translation authorised by DIBt. to: 1 December January 2017 I /16

Glycerine filled Bourdon tube pressure gauges EN 837-1

Z5554 Mounting instructions 1.1 en

INSTALLATION OPERATION AND MAINTENANCE MANUAL GEARLESS MG250

Zero cross function. DIN track mounting *2. Screw mounting

Float valves Types SV 4, SV 5 and SV 6

Mechatronic pressure measurement. Applications. Special features. Description

Technical Delivery Conditions Magnets

StairTrainer USER MANUAL STAIRTRAINER GB VERSION 2.0

EU-TYPE EXAMINATION CERTIFICATE

Z5043 MAX Horizontal bracket Mounting instructions

WOODEN TOWERS FOR WIND ENERGY PLANTS

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

GUNNEBO INDUSTRIES ROV RETRIEVE 861 SHACKLE

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction

FDA-general purpose waterproof material. FDA-compliant and wearresistant. FDA-material for high temperatures and high load

Recommended Land Pattern: [mm]

European Technical Assessment ETA-14/0354 of

SPECIFICATION #AES-222C*

Printview: 4-conductor ground terminal block - Item No.:

Pipe Joints. Requirements and Test Methods. VdS-Guidelines for water extinguishing systems. VdS en. VdS en : (01)

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm]

SYSTEM ATHMOS INSTALLATION MANUAL

4-Beam-Turbidity Meter ITM-4

National technical approval

S7 Taifun Installation Manual

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm]

Transcription:

EU type examination for ETN-lift buffers The type examination tests for ETN lift buffers made from Cell-PU have been carried out in accordance with lift directive 95/16/EG. The certificate number records the permissible load ranges for every type of lift buffer. An EU type examination test certificate can be issued for every type of lift buffer on request. Dimens. Buffer type / Load range Ø x H Certificate m max. [kgs] [mm] No. m min. [kgs] Max. nominal speed 1,0 m/s 100 x 80 EN 2 3.240 APV 040 190 125 x 80 EN 3 6.510 APV 036 240 165 x 80 EN 4 8.010 APV 037 290 11.12.2007 Specified office: TÜV Industrie Service GmbH TÜV SÜD Gruppe Zertifizierungsstelle für Aufzüge und Sicherheitsbauteile page 2

EU-Declaration of Conformity for ETN-lift buffers Subject: ETN-lift buffers Dimensions and load ranges: see table, page 2 Materials: ETN-lift buffer: Mounting plates: ETN - Cell-PU steel We hereby declare that the construction conforms to the relevant regulations of the lift buffer attachments with non-linear characteristics lift directive 95/16/EG Harmonised standards used: DIN EN 81-1 (1998) + A3: 2009 DIN EN 81-2 (1998) + A3: 2009 Nominated test centre for the execution of EC type examination test: TÜV Industrie Service GmbH TÜV SÜD Gruppe Zertifizierungsstelle für Aufzüge und Sicherheitsbauteile Notified body: 0036 EC type examination test certificate no.: see table, page 2 Production monitoring by: LIFTINSTITUUT B.V. Buikslotermeerplein 381 NL-1025 XE Amsterdam Notified body: 0400 Year of manufacture of buffer attachment: 2012 Management: 02.01.12 Horst Eichler Date Signature

Operating instructions for ETN-lift buffers ETN lift buffers are used as springs and damping elements for lifts. Depending on the type of lift (with or without choke or choke non-return valve), ETN lift buffers are available in a range of sizes for different max. and min. loads. The load ranges for ETN lift buffers are recorded in the EC type examination certificates. ETN lift buffers are manufactured with a circular steel mounting plate with central hole for central screw fitting. ETN lift buffers can be arranged side-by-side or in line, but the following must be noted when fitting the units: Side-by-side mounting of the lift buffers The distance between the outer surfaces of the buffer must be at least 40 % of the buffer diameter (e.g. buffer 100 mm, distance 40 mm) Ambient conditions Temperature range: -40 C to +80 C, continuous use up to 50 C Humidity: 70% relative humidity at room temperature Avoid continuous contact with water Contamination: Oil and grease compatible, but protect agains acids and cleaning agents. Life, maintenance ETN lift buffers have a minimum life of at least 5 years, but we cannot guarantee this. They are maintenance-free, but they should be subjected to regular visual checks when inspecting and maintaining safety components. Should the shape of the buffer have undergone considerable visible change, it must be exchanged for a new item. The buffer must also be changed after the lift cage has dropped hard on to the buffer. Changes in colour of the buffer from white to brown relate to the material and have no influence on the technical and physical characteristics of ETN lift buffers. Note ETN lift buffer may only be used when it has been determined that the lift installation conforms to the Lift Directive 95/16/EU. ETN lift buffers must not be subjected to a continuous load and therefore must not be used as resting point during repair and maintenance work.

Lift buffers corresponding to EN 81 Calculation Customer Lift-no. Operating speed V = m/s 1. Cage + Working load Number of buffer (n) = m max = m min = Q + F = n kg + F n = = kg Buffer-no. 2. Counterweight Number of buffer (n) = m G = F + Q 2 n = + 2 = kg Buffer-no. m = Weight [kg] F = Cage weight [kg] Q = Working load [kg] m G = Counterweight [kg] Lift producer: Technical regularity body: Signature: Signature: Dated: Dated: