Membryl UV stable waterproofing membrane.

Similar documents
DESCRIPTION FEATURES AND BENEFITS AREAS OF USE. Showers & Bathrooms. Balconies & Patios SUITABLE SUBSTRATES. for application on: Concrete & Masonry

Shower Waterproofing Membrane Under tile and wet area waterproofing membrane.

Rapid Re-coat PU Modified Under-tile waterproof membrane.

Westbuild PRO. Rapid Drying Wet Area Waterproofing. Polyurethane (PU) modified, permanently flexible, rapid drying, class III waterproof membrane.

DESCRIPTION. DiamondCoat FEATURES AND BENEFITS AREAS OF USE

FEATURES AND BENEFITS

Concrete Paving Sealer Clear, tough, gloss finish surface treatment.

DESCRIPTION FEATURES AND BENEFITS AREAS OF USE. DiamondCoat Polyurethane Concrete Floor Finish is suitable for use in the following areas:

FEATURES AND BENEFITS

FEATURES AND BENEFITS

Pool Paving Sealer Clear, natural finish, water repellent treatment.

Product Information. DiamondCoat Polyurethane Concrete Floor Finish Clear, high build, high abrasion resistant, decorative concrete floor coating

FEATURES AND BENEFITS

Technical Data Sheet

Crystoflex Max comprising of a liquid component of selected polymers and a powder component of selected cements, fillers and aggregates.

Lithium Densifier Concrete floor densifier, hardener and dust-proofer.

AQUATITE. Also designed as: Crack/gap filler for masonry and unglazed ceramics Sealants against leaks Repairer for roof cracks and gutters

WPM WATERPROOFING MEMBRANE

Technical Data Sheet

PRODUCT INFORMATION SABRESHIELD

3,Rothwell Street, Timaru, South Canterbury. ; : Phone or

Multithane UV is designed to waterproof most applications within the building and construction industry including:

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

Sikaflex -1a. One-Part Polyurethane, elastomeric sealant/adhesive. Product Description. Product Data

Emer-Proof Quick Dry Two Part

Data Sheet Eco-Smart Membrane WS M1

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

80212R StoColor Lastic Acrylic-Based, Elastomeric Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

1-part polyurethane pourable self levelling floor joint sealant

80648R StoCoat Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

80648R StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

80201R StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Construction. One component cementitious mortar fibre reinforced for flexible waterproofing. Product Description. Product Data. Form.

Construction. Sikagard -680S. Methacrylic resin protective and anti-carbonation coating for concrete. Product Data Sheet Version 9/5/05.

MasterSeal HLM Liquid cold-applied elastomeric waterproofing membrane system

Liquid applied polyurea hybrid membrane

TECHNICAL DATA SHEET SIKALASTIC-1K

Spray applied waterproofing membrane

1-part elastic joint sealant and multipurpose adhesive

AVM System 500. Aussie Membrane 500

AVM System 500. Aussie Membrane 500

METHOD STATEMENT SIKALASTIC -680 AP SIKA LIMITED (VIETNAM)

Non-sag, ultra low modulus, neutral cure silicone sealant for pavements

PEKAY T570 RUBBERSEAL

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

838 Coatings System Specification Single-Ply Restoration (838 SPR)

80648 StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

Fosroc Nitodek UR200 System

Construction. 1-part floor joint sealant. Product Description. Product Data. Tests. Form. Storage

Pacific Polymers Elasto-Deck 5000MR Guide Specification

Pacific Polymers Elasto-Mat D&G Guide Specification

Multithane UV is also available in a thicker grade (Vertical Grade) for exposed vertical surfaces.

MEMBRANE 510/510R Low VOC Flexibilized, Urethane Membrane mils

1-part high performance sealant for flooring

Construction. Sika FerroGard Method Statement for Application Corporate Construction. Scope:

80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

PRODUCT DATA SHEET Sikalastic -501 Roofseal Plus

1-part elastic joint sealant and multipurpose adhesive

Pacific Polymers Elasto-Deck BT Guide Specification

SIKA CAR PARK DECK SYSTEM. Product. Scope. Appraisal No. 781 [2019] Appraisal No. 781 (2019) This Appraisal replaces BRANZ Appraisal No.

SealArm Tape TPE. Building & Joint Sealants T E C H N I C A L D A T A S H E E T. Uses. Features and Benefits

Dist. by: BEST MATERIALS Ph:

Liquid applied pure polyurea membrane

PERM-A-BARRIER NPS Detail Membrane

TECHNICAL DATA SHEET SIKABOND AT METAL GREY 300CC

Section COATING RESTORATION

Fosroc Nitoproof 800 Method Statement

Construction. 1-part high performance sealant for flooring. Product Description. Environmental Information. Product Data Sheet Edition _1

Approx. 12 m² per litre depending on surface porosity, profile. Application methods

Construction. SikaMembran system Vapour control/waterproofing sheet system for ventilated curtain walling

MasterSeal M 616. THEORETICAL CONSUMPTION kg/m 2. PACKAGES 25 kg and 5 kg cans

80230 StoColor Coat Sand Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

Ure-plex [ TECHNICAL BULLETIN ] POLYURETHANE WET AREA MEMBRANE PRODUCT TYPE DESCRIPTION / USE

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

YEARS WATER PROOFING AND PERFORMANCE WARRANTY*

1 ST KOTE HI COVER PVA

SECTION FLUID-APPLIED WATERPROOFING

A range of popular roof shades Spruce Acrylic Roof cannot be tinted.

Magna Wall. Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

National Construction Code Series (NCC 2016) Building Code Of Australia (BCA)

HAMMERITE NO. 1 RUST BEATER PRIMER

EPILOX EPOXY BINDER TECHNICAL DATA SHEET. Multi-purpose High Performance Epoxy Binder System DESCRIPTION FEATURES AND BENEFITS

TECHNICAL DATA SHEET SIKAFLEX FLOOR

Sikaflex PRO-3 PROVISIONAL PRODUCT DATA SHEET HIGH-PERFORMANCE SEALANT FOR FLOOR JOINTS AND CIVIL ENGINEERING APPLICATIONS DESCRIPTION

DOWSIL ALLGUARD Silicone Elastomeric Coating

1-part elastic joint sealant and multipurpose adhesive

SECTION SELF-ADHERING SHEET FLASHING

MASTERSEAL HLM 5000 R

Heatgard 4 acts as a protective shield against Solar Radiation by re-radiating most of the infra-red & ultra violet rays back into the atmosphere.

Section COATING RESTORATION

PRODUCT DATA SHEET Sikalastic -590

SILASEC DESCRIPTION FEATURES AND BENEFITS SURFACE PREPARATION

SMARTCARE DAMP PROOF TECHNICAL PARAMETERS

Transcription:

Technical Data Sheet July 2017 DESCRIPTION is a waterborne elastomeric waterproofing membrane with outstanding long-term UV stability. is an effective anti-carbonation membrane for concrete as it exceeds the Klopfer Criterion requirements of Sd < 4m and R > 50m. SUBSTRATES is suitable for application on; Concrete & Brick Timber Plywood Sheeting Metal Sheeting Structural Screeds ADVANTAGES delivers the following advantages; Seamless waterproofing system - liquid applied with no joints or laps, not allowing ingress of water or contaminants. Elastomeric, even after weathering. Anti-carbonation protection of concrete. Tough and trafficable - high tensile strength and hardness. Allows substrate to breathe. Fungal and algal resistant - an extended life and clean appearance in high humidity environments. Fire and flame resistive. Chemical attack resistive. Excellent resistance to dirt pick up. Very high adhesive strength. High build - bridges fine cracks. Resistive to impact and light traffic damage. Weatherproof and lightfast. Not suitable for use in areas of ponding water. TESTING APPROVALS AND STANDARDS is compliant with the following standards; Green Star - Design & As Built v1.1: Indoor Pollutants 13.1 Paints, Adhesives, Sealants and Carpets. APAS 181 V.O.C limits. AS4654.1 Waterproofing membrane systems for exterior use Above ground level, Part 1: Materials. TECHNICAL DATA (@ 25⁰C) Number of Coats: Coverage: (per coat) Wet Film: (per coat) Recoat: Full Cure: Colour: 4 6 h 7 days White, Off White, Gull Grey AREAS OF USE is suitable for use in the following areas; Concrete Roof Areas External Walls Clean Up: Shelf Life: Water 12 months Balconies Parapet Walls Decks Page 1 of 5

TEST DATA Properties Measurement / Standard Test Results VOC Content ASTM D-2369 10g/L (Low) Tensile Strength: ASTM D412 3.66MPa Elongation: ASTM D412 140% Durometer Hardness ASTM D2240 Durometer A Value 78.5 Direct Tension Adhesion Strength ASTM D4541 2.0 MPa Mandrel Bend Test (6mm) AS1580.402 / ISO 1519 Pass-no cracking, flaking or peeling observed. Water Vapour Transmission ASTM E96 35.6g / m 2 / 24 hours Permeance ASTM E96 1.47 x 10-7 g / Pa.s.m 2 Moisture Vapour Diffusion Coefficient (DH20) ASTM E96 4.3 x 10-5 cm 2 sec -1 Moisture Vapour Diffusion Resistance Coefficient (µ) Moisture Vapour Equivalent Air Layer Thickness (Sd) ASTM E96 5920 ASTM E96 1.21m Oxygen Diffusion Coefficient Carbon Dioxide Diffusion Coefficient Diffusion Resistance Coefficient (µ) Equivalent Air Layer Thickness (R) Equivalent Thickness of Concrete (Sc) Chemical Resistance 10% W/V Sodium Hydroxide 10% W/V Nitric Acid Fire Propagation Surface Spread of Flame Resistance to Artificial Weathering 1000 hours 4000 hours Biological Resistance Fungal 1 month (accelerated) Algal 6 months (accelerated) Taywood in-house test method Section 5.4 (Gas Dispersion Test) Taywood in-house test method (as nominated) B.S. 476: Part 6 B.S. 476: Part 7 AS 1580.483.2 Thor In-house Accelerated Testing 2.9 x 10-7 cm 2 sec -1 4.9 x 10-7 cm 2 sec -1 305800 64m 16cm 1 hour temporary effect 3 hours temporary effect 1 hour no visible change 3 hours no visible change 3.3 Fire Propagation Index Class 1 Satisfactory no defects Satisfactory no defects Excellent Film Fungal Protection Excellent Film Algal Protection Abrasion Resistance ASTM D1242 0.18mm Page 2 of 5

SPECIFICATIONS Waterproofing reinforced trafficable; Spreading Rate W.F.T. D.F.T. 1 st Coat - 1.6m 2 /L 625 µm 300 µm Whilst wet embed Crommelin Polyfab 40 µm 2 nd Coat - 1.6m 2 /L 625 µm 300 µm Anti-carbonation weatherproof membrane; 640 µm Spreading Rate W.F.T. D.F.T. 1 st Coat - 4.8m 2 /L 210 µm 100 µm 2 nd Coat - 4.8m 2 /L 210 µm 100 µm ANCILLARY PRODUCTS 200 µm Crommelin Contractor Polyurethane Sealant 600ml Crommelin Silicone WP Plus 300ml Crommelin Polyfab reinforcing fabric Crommelin Polyfab BB bond breaker Crommelin Contractor Membrane Applicator Brush 100mm, 75mm Crommelin Contractor Membrane Roller Cover 230mm Crommelin Moisture Meter SUBSTRATE PREPARATION AND PRIMING Full substrate preparation instructions can be found at www.crommelin.com.au/full-instructions/ Surfaces must be clean, dry, sound and free from dust, grease, curing compounds, release agents, loose particles, efflorescence, concrete laitance or any other contaminants. Exposed reinforcing bars are to be cleaned of rust prior to repair. If cementitious repair products are used. they should be cured for a minimum of 7 days, however 28 days is preferable. Remove contaminants such as grease and oil with Crommelin HD Cleaner. Areas showing fungal or algal growth should be treated with Crommelin Enhance Pre-Seal and allowed to dry. Remove dust, loose dirt, flaking paint, rust etc. as appropriate by high pressure water jetting, abrasive blasting or mechanical/hand wire brushing. Substrates that are porous and/or slightly dusty should be primed with a 2:1 dilution of Membryl and water. Painted areas should be checked for soundness. Remove loose paint and prime area with Crommelin Next Day SB. Allow to dry for 24 hours. Cracks or joints displaying non-active cracks wider than a hairline should first be filled with proprietary filler. All active cracks and expansion or construction joints are to be cleaned to accommodate a backing rod combined with proprietary elastomeric filler. Note: Due to the wide variety of substrates available, adhesion testing is recommended in a trial area before full application. If substrate is not dry, prime surface with Crommelin WB2K. Page 3 of 5

APPLICATION CONDITIONS Substrate must be dry, with less than 15% moisture content. The use of suitable moisture meter is recommended. Application temperature between 7 C - 35 C. Do not apply if relative humidity is above 85% during initial cure phases, or if rain is expected before cure. Note: In humid conditions, air flow should be maximised with the use of fans to assist cure. APPLICATION Full application instructions can be found at www.crommelin.com.au/full-instructions/ Apply Crommelin Polyfab BB or Bond Breaking Sealant to internal angles/corners (wall & floor junction) and vertical angles/corners (wall & wall junction) as per standard. Apply with Crommelin Contractor Membrane Brush, Crommelin Contractor Roller or similar. Apply first coat of as per recommended coverage rate. Work from corners to central areas and allow to dry. If only a bond breaking sealant has been used, it is recommended to install Crommelin PolyFab Reinforcing Fabric to all joints and corners in conjunction with first coat of. Apply second coat of as per recommended coverage rate, at 90⁰ to the first coat. Pre-Existing sealants/mastics - in general Membryl can be directly applied to most mastics, however, nonpaintable silicones are not suitable. If it is silicone or it cannot be identified, apply Crommelin Polyfab BB over the area as detailed above, before treating with. Upright angles and protrusions - sharp corners formed by vertical and horizontal junctions such as parapets and pipes, etc. should be detailed in a similar fashion with Crommelin Polyfab BB as detailed above. APPLICATION - CONTINUED The ends of vertical membranes should be protected to avoid ingress of water behind the membrane. On parapet walls, if possible, the membrane should be carried to the top and slightly down on the other side thus eliminating water ingress. On high vertical walls or protrusions, the horizontal membrane should be turned up approximately 200mm and applied into a reglet (5mm wide and 10mm cut) and / or covered with a down-turned protective flashing. CLEAN UP Uncured material may be removed with warm water and detergent. Cured material may be removed mechanically. Cured material may be softened by soaking in Crommelin HD Cleaner before attempting removal. MAINTENANCE SCHEDULE AND REPAIR must be protected from damage by after trades and inspected prior to the application of any over coat. Moisture blisters and bubbles may be repaired by cutting out the affected areas, allowing substrate to properly dry and reapplication of membrane as per recommended coverage rates. Protect membrane from harsh chemicals, abrasion and other potentially damaging conditions. PRECAUTIONS Do not apply if the temperature is below 7 C or relative humidity is above 85% or if rain is imminent. Do not allow ponding to occur between coats or before system is fully cured (normally 7 days after application of final coat). Water should be swept off or mopped during curing period to avoid damage. Page 4 of 5

WARRANTEES A standard warranty period of 10 years is offered for Crommelin. Extended warrantees are available for project specific applications. Please contact your Crommelin representative, or the Crommelin technical support team for detailed specifications applicable to your project and warranty requirements. TRANSPORT AND STORAGE Size: 15L DG Class: N/A UN Number: N/A Weight: 22.5kg Flash Point: N/A Cool and Dry Storage SAFETY AND FIRST AID Safety Data Sheet is available from Crommelin upon request. Safety Ensure good ventilation and avoid breathing vapours. Avoid skin and eye contact. Wear gloves and eye protection. Remove splashes on skin immediately and remove contaminated clothing. Keep out of reach of children. Keep container sealed when not in use. Do not swallow. First Aid If poisoning occurs, contact a doctor or poisons information centre: Ph. 13 11 26. If swallowed, do not induce vomiting. Give a glass of water to drink. If in eyes, hold eyes open and flood with water for at least 15 minutes. If not breathing, apply artificial respiration. Crommelin and other marks followed by are registered trademarks. Any advice, recommendation, information, assistance or service provided by Crommelin in relation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need to undertake their own assessment to determine the suitability of a product for the intended use. As the performance of any product is subject to a wide variety of different surface types as well as environmental and surface-specific conditions, it is essential that a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and finish and that it performs as required on the specific surface. Crommelin also reserves the right to update information without prior notice, to reflect ongoing research and product development. Page 5 of 5