Application Note. Authors. Abstract. Introduction. Pharmaceutical

Similar documents
Fast Analysis of Environmental Phenols with Agilent Poroshell 120 EC-C18 Columns

EPA 8330A Analysis of Explosives Using Agilent Poroshell 120 EC-CN and EC-C18 Columns

Emulation of the Agilent 1100 Series LC Through Waters Empower Software Analysis of an Analgesic Mixture

Method Translation in Liquid Chromatography

Determination of Asarinin in Xixin (Asari Radix Et Rhizoma)

Agilent 1290 Infinity Quaternary LC Support of Columns with 2.1 to 4.6 mm ID to 1200 bar

Fast, Low Pressure Analysis of Food and Beverage Additives Using a Superficially Porous Agilent Poroshell 120 EC-C18 Column

Performance Characteristics of the Agilent 1220 Infinity Gradient LC system

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

Agilent 1290 Infinity Binary LC System with ISET Emulation of a Waters Alliance 2695 LC Applying Concave, Convex, and Linear Gradients

Automated alternating column regeneration on the Agilent 1290 Infinity LC

Agilent 1290 Infinity LC with ISET under Waters Empower control Emulation of Agilent 1100 Series LC

Reversed-phase Separation of Intact Monoclonal Antibodies Using Agilent ZORBAX Rapid Resolution High Definition 300SB-C8 1.

Performance characteristics of the 1260 Infinity Quaternary LC system

Application Note. Author. Abstract. Pharmaceuticals. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Abstract. Authors. Introduction. Environmental

Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector

Technical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Faster Separations Using Agilent Weak Cation Exchange Columns

Comparing gradient transfer of isocratic hold and delay volume addition using the Agilent 1290 Infinity LC with ISET

Application Note. Environmental. Agilent 1290 Infinity Binary LC. with ISET and fine-tuning. Agilent 1290 Infinity Binary LC.

Developing Purification Strategies for the Agilent 1260 Infinity II Preparative LC/MSD System

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

Method Transfer from an Agilent 1200 Series LC to an Agilent 1260 Infinity II LC

High-Throughput LC/MS Purification of Pharmaceutical Impurities

Automated Scouting of Stationary and Mobile Phases Using the Agilent 1290 Infinity II Method Development Solution

Transferring a Method from a Conventional 3.5 µm or 5 µm to an Agilent Poroshell 120 Column to Improve Analytical Speed and Resolution

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

Agilent 1290 Infinity Binary LC System with ISET - Emulation of the Waters Alliance 2695 LC system analyzing b-blockers

Application Note. Biopharma. Authors. Abstract. James Martosella, Phu Duong Agilent Technologies, Inc Centreville Rd Wilmington, DE 19808

Rapid UHPLC Analysis of Reduced Monoclonal Antibodies using an Agilent ZORBAX Rapid Resolution High Definition (RRHD) 300SB-C8 Column

Scale-up with the Agilent SD-1 Purification System analytical and preparative runs on a single system

A Guide To Speeding Up Your Separation

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit

New Advances in UHPLC -Resolution, Speed & Sensitivity

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Separation of Recombinant Human Erythropoietin (repo) Using Agilent Bio SEC-3

EPA Method 540: Selected Organic Contaminants Using Agilent Plexa Cartridges and the Agilent 6460 Triple Quadrupole LC/MS

Analysis of Trace Organic Contaminants in Water by Direct Injection Using Agilent 6490 LC/MS/MS with Pos/Neg Switching

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Reproducible LC/MS Peptide Separation Using Agilent AdvanceBio Peptide Plus Columns

ISET. Agilent 1290 Infinity Binary LC with ISET, emulation of the Waters Alliance 2695 LC system analyzing aromatic acids. Application Note.

Application Note. Abstract. Authors. Environmental

Robustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Analytical Instrument Qualification According to USP <1058>: Requirements and Examples for the Agilent 1290 Infinity LC System

BioHPLC columns. Tim Rice Biocolumn Technical Specialist

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

Determination of Pesticides in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes. Application Note. Author. Abstract.

Preparative Purification of Corticosteroids by HPLC; Scalability and Loadability Using Agilent Prep C18 HPLC Columns Application

Peptide Mapping: A Quality by Design (QbD) Approach

Practical Applications of Method Translation Using the Agilent Method Translation Tool. eseminar and Workshop

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

Automated Online SPE for LC/MS/MS Analysis of Trace Organic Contaminants in Water Using the Agilent 1290 Infinity Flexible Cube Module

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

Optimizing Protein Separations with Agilent Weak Cation-Exchange Columns

Agilent 6430 Triple Quadrupole LC/MS System

Fast Method Development Using the Agilent 1290 Infinity Quaternary LC System with Column Selection Valve

Increased Throughput in the Determination of PPCPs in Water Using Optimized MS Cycle Times in a High Sensitivity UHPLC-Triple Quadrupole System

Method Transfer from an Agilent 1260 Infinity LC to an Agilent 1260 Infinity II LC

Authors. Introduction. Experimental. Environmental Analysis

Characterize mab Charge Variants by Cation-Exchange Chromatography

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

AdvanceBio Peptide Mapping

Analysis of amoxicillin and five impurities on the Agilent 1220 Infinity LC System

ENVIRONMENTAL ANALYSIS. Solutions for Your Analytical Business Markets and Applications Programs. Solution Note

Agilent 1260 Infinity Purification Systems. Infinitely better purity and recovery

Agilent 1260 Infinity LC & LC/MS Purification Systems. Purify your way

Clone Selection Using the Agilent 1290 Infinity Online 2D-LC/MS Solution

Prefractionator for Reliable Analysis of the Light Ends of Crude Oil and other Petroleum Fractions

Simplifying Methods Transfer: Novel Tools for Replicating Your Established Methods on an ACQUITY Arc System

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

Peptide Mapping. Hardware and Column Optimization

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

Analysis of TCM injections using the Agilent 1290 Infinity LC system

Analysis of Monoclonal Antibody (mab) Using Agilent 1290 Infinity LC System Coupled to Agilent 6530 Accurate-Mass Quadrupole Time-of-Flight (Q-TOF)

Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

Infinitely better. Agilent 1200 Infinity Series. Infinity LC. Infinity LC. Infinity LC. products applications soft ware services

Minimizing Sample Carryover Using the Multiwash Function of the Agilent 1290 Infinity II Multisampler

Agilent 218 Purification System. Purify your way

Performance characteristics of the Agilent 1100 Series capillary LC system using diode-array UV and MS for detection. Technical Note.

Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application

Multiple Detector Approaches to Protein Aggregation by SEC

Agilent Prep LC Columns for Small Molecules and Biomolecules MAINTAIN RAPID, RELIABLE SEPARATIONS AS YOU SCALE-UP

Puzzled About LCMS? Sample. Sensitivity in Mass Spec Analysis. Prep. Adapting LC-UV. Optimizing and Maintaining Your Mass Spec LCMS

A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery Using HPLC-Chip/ MS-Enabled ESI-TOF MS

Technical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Inertsil ODS-3 2 µm. Base Silica Physical Properties and Chemical Modification. Base Silica: High Purity Silica Gel % Surface Area: 450 m 2 /g

The Agilent 1260 Infinity BioInert Quaternary Pump. Scope of a low-pressure mixing UHPLC pump with Bio-Inert Capabilities

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Transcription:

Scalability of Agilent s Across HPLC and UHPLC Instruments Application Note Pharmaceutical Authors Anne E. Mack, William J. Long Agilent Technologies, Inc. 2850 Centerville Road, Wilmington, DE 19808 USA Abstract LC method transfer across several instrument types, using Agilent and non-agilent systems, demonstrates the scalability of Agilent columns with different configurations and stationary phases. This ability to easily scale a method from one system to another is particularly useful in the pharmaceutical industry where samples may have to be analyzed by R&D, QC, or other laboratories where identical instrument setups may not be possible or where analytical needs may vary. Introduction Instrumentation and column technology for liquid chromatography continually improve, to deliver higher throughput, higher resolution, and higher sensitivity. Transferring an LC method from one instrument to another should be straightforward. However, columns specifically designed for one instrument are often not recommended, or necessary for another instrument. Newer, sub-2-µm columns are designed to withstand higher pressures than traditional HPLC systems, as a result, the smaller particles cannot be fully used within 400 bar. In addition, differences in system delay volume and extra-column volume could affect column performance from one instrument to another, most notably with small internal diameter columns. Therefore, scalability between column dimensions, especially with respect to particle size, is paramount to ensure straightforward method transfer. The flexibility of Agilent ZORBAX columns in several configurations and stationary phases is demonstrated by transferring an LC method across several instrument types, using Agilent and non-agilent systems.

Experimental LC Method Parameters An Agilent 1200 Series RRLC, a 1290 Infinity LC, a 1290 Infinity LC/6410 Triple Quadrupole MS system, and a non-agilent UHPLC are used in this experiment. Mobile phase A: 0.2% formic acid in water; B: acetonitrile Gradient 15% to 95% B, gradient time ( ) varies according to column dimensions and flow rate, see Equations 1 and 2 DAD Sig = 260, 4 nm; Ref = Off MS Source 350 C, 12 L/min, 50 psi, 3500 V MS Scan Positive ESI, Delta EMV 200, Fragmentor 135 V, Scan 100 400, 5 ms scan time, 0.2 amu step, 28.36 cycles/s, 35.3 ms/cycle Analytes in elution order with identifying mass acetaminophen (109), caffeine (194), 2-acetamidophenol (109), acetanilide (135), acetylsalicylic acid (120), phenacetin (179), salicylic acid (120), sulindac (356), piroxicam (332), tolmetin (257), ketoprofen (254), diflunisal (332), diclofenac (295), celecoxib (381), ibuprofen (160) Sample 0.01 mg/ml (UV) and 1 µg/ml (MS) each in water The following Agilent LC columns were used: Description P/N Agilent ZORBAX Eclipse Plus C18 4.6 mm 250 mm, 5-µm 959990-902 Agilent ZORBAX Eclipse Plus C18 4.6 mm 150 mm, 5-µm 959993-902 Agilent ZORBAX Eclipse Plus C18 3.0 mm 100 mm, 3.5-µm 959961-302 Agilent ZORBAX RRHD Eclipse Plus C18 3.0 mm 100 mm, 1.8-µm 959758-302 Agilent ZORBAX RRHD Eclipse Plus C18 3.0 mm 50 mm, 1.8-µm 959757-302 Agilent Poroshell 120 EC-C18 3.0 mm 100 mm, 2.7-µm 695975-302 Agilent Poroshell 120 EC-C18 3.0 mm 50 mm, 2.7-µm 699975-302 Gradient Scaling Once a gradient separation has been optimized (selectivity and retention index), it is possible to further improve the chromatography by varying column length, particle size and flow rate. However, the k* value (Equation 1) must be maintained while varying these column conditions, so as not to lose selectivity while scaling the gradient. Equation 1 k* = ( F)/(d/2) 2 L(D%B) where: = gradient time F = flow rate d = column internal diameter L = column length D%B = change in organic content across gradient segment Assuming a constant k*, Equation 1 can be simplified to Equation 2 below: Equation 2 2 = (1 d 2 2 L 2 F 1 )/(d 2 1 L 1 F 2 ) where: 1 and 2 = original and new gradient times F 1 and F 2 = original and new flow rates d 1 and d 2 = original and new column internal diameters L 1 and L 2 = original and new column lengths Additionally, in Equation 2, v 1 and v 2 can be substituted for 1 and 2 respectively to accurately scale a method s injection volume according to a new column s dimensions. Instrument, Compatibility Considerations While almost any column can be installed and run on any instrument, pressure limitations by the LC and pressure generated by the column can lead to the inability to optimally utilize any column on any LC. For example, small particles generate substantial back pressure, especially when packed into long columns, this particular column configuration is not best suited for a conventional 400 bar HPLC, as that pressure limit will easily be exceeded as flow rates increase. Table 1 lists the specifications of several Agilent LC systems that are critical to good performance, while Table 2 shows compatibility between instruments and columns for UHPLC and HPLC. 2

Table 1. Critical Parameters of Agilent LC Systems Agilent 1100/1200 Series Binary HPLC Agilent 1200 Series RRLC (std) Agilent 1260 Infinity Binary LC Pressure limit (bar) 400 600 600 1200 Max flow rate (ml/min) 5 5 5 5 Pump Delay volume (µl) 600 900 600 800 600 800 (120*) 45/75 Capillary id (mm) 0.17 0.17 0.17 (0.12*) 0.12 Dispersion volume w/o cell (µl) 15 15 15 (7.5*) 7.5 Injection principle Variable loop Variable loop Variable loop Variable loop Agilent 1290 Infinity Binary LC Injection volume (std/ext) (µl) 100/1500 100/1500 100/1500 20/40 (100 up to 600 bar) Area RSD (%) < 0.25 < 0.25 < 0.25 < 0.25 *optimized for 2.1 mm id Table 2. Instrument and Compatibility in Agilent UHPLC and HPLC Systems (Green [Compatible] to Red [Incompatible]) UHPLC 1.8 µm particles UHPLC superficially porous particles HPLC 3.5 5 µm particles length (mm) Short, 30 50 Long, 100 150 30 150 50 300 id (mm) 2.1 3 4.6 2.1 3 4.6 2.1 3 4.6 3 4.6 Max pressure (bar) 1200 600 600 1200 600 600 600 600 400 Agilent column RRHD* RRHT^ RRHT RRHD RRHT RRHT Poroshell Poroshell Various Agilent 1290 Infinity (1200 bar) Agilent 1260 Infinity/1200 RRLC (600 bar) Agilent 1100/1200 Series (400 bar) *rapid resolution high definition ^rapid resolution high throughput 3

Results and Discussion Maintaining Selectivity with Different Dimensions As shown in Figure 1, selectivity is maintained when a 5-µm column is shortened from 250 mm to 150 mm, and when transferred to a 3 mm 100 mm, 3.5-µm column. Some resolution, however, is lost with the shorter columns, most notably with ibuprofen, the last peak to elute. Agilent ZORBAX Eclipse Plus C18 4.6 mm 250 mm, 5 µm 8.8 min 110 bar 2 4 6 8 10 min Agilent ZORBAX Eclipse Plus C18 4.6 mm 150 mm, 5 µm 5.3 min 77 bar 1 2 3 4 5 6 min Agilent ZORBAX Eclipse Plus C18 3 mm 100 mm, 3.5 µm 0.4 ml/min 3.6 min 87 bar 0.5 1 1.5 2 2.5 3 3.5 4 4.5 min Figure 1. Maintaining selectivity on Agilent ZORBAX Eclipse Plus C18 columns with different dimensions and particle sizes using an Agilent 1200 Series RRLC. 4

Effect of System Delay Volume A manual change in system delay volume is the cause of a pronounced difference in the early eluting peaks (Figure 2). The relatively large delay volume of an Agilent 1200 Series RRLC system if set-up in a standard delay volume and not in low delay volume configuration with a smaller dimension column (in this case 3 mm 100 mm, 3.5 µm) causes delayed elution of all peaks. In order to make the chromatography more similar to the larger dimension columns shown in Figure 1, the automatic system delay volume reduction feature of the Agilent 1200 Series autosampler can be used, as shown in the bottom chromatogram in Figure 2. Method Transfer across Agilent Instruments Transferring the method from a 1200 Series RRLC to an Agilent 1290 Infinity LC yields very similar results with the 3.5-µm column, as shown in Figure 3, when the automatic delay volume reduction feature of the 1200 Series autosampler is used. As shown in Table 1, the delay volume of a 1290 Infinity LC system is substantially lower than the 1100/1200 Series or 1260 Infinity LC systems. The same is true for other vendors UHPLC systems optimized for lowest delay volumes. Also, typically the mixing behavior, that is, the slope of a step gradient, is much steeper for such instruments. 196 bar Automatic delay volume reduction OFF 0.25 0.5 0.75 1 1.25 1.5 1.75 2 min 196 bar Automatic delay volume reduction ON Figure 2. 0.25 0.5 0.75 1 1.25 1.5 1.75 2 min Effect of system delay volume on an Agilent ZORBAX Eclipse Plus C18 3.0 mm 100 mm, 3.5-µm column using an Agilent 1200 Series RRLC without (top) and with (bottom) the delay volume reduction function on the autosampler. Instrument Agilent 1200 Series RRLC 196 bar 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 min Instrument Agilent 1290 Infinity LC 200 bar Figure 3. Comparing separations on Agilent 1200 Series RRLC and Agilent 1290 Infinity LC instruments, using an Agilent ZORBAX Eclipse Plus C18 3.0 mm 100 mm, 3.5-µm column. 5

Conversely, if a method originally developed on a 1100/1200 Series or 1260 Infinity LC needs to be transferred to a 1290 Infinity LC system, a larger delay volume would be needed and, ideally, also an adoption of the mixing curve. For this, an isocratic hold can be added manually to the method, or physically the volume can be added by additional capillary tubing. Both need upfront determination of the required volume. The use of the new Intelligent System Emulation Technology (ISET), available only for 1290 Infinity LC systems, is a new technology that makes this process easier. ISET emulates the different delay volumes and mixing behaviors of Agilent s or other LC systems on a 1290 Infinity LC and delivers the same results without manual changes of the method or hardware. For more information see Agilent Pub. No. 5990-8670EN. Method Transfer across Agilent s Totally porous 1.8-µm and 3.5-µm Agilent ZORBAX columns yield the same selectivity, while superficially porous 2.7-µm Poroshell 120 delivers very similar selectivity as a result of similar bonding chemistry. Both 1.8-µm Agilent ZORBAX RRHD and 2.7-µm Agilent Poroshell 120 provide better resolution than the 3.5-µm ZORBAX column of the same dimensions, as can be seen in Figure 4. Referring to Table 2, the scalability illustrated in Figure 4 indicates that there is an Agilent LC column to meet any instrument need. In this case, the same separation can be performed on a 400 bar instrument with a 3.5-µm column, on a 600 bar instrument with a superficially porous 2.7-µm column, or on a 1200 bar instrument with a 1.8-µm column. Agilent ZORBAX Eclipse Plus C18 3.0 mm 100 mm, 3.5 µm 200 bar Agilent ZORBAX RRHD Eclipse Plus C18 3.0 mm 100 mm, 1.8 µm 645 bar Agilent Poroshell 120 EC-C18 3.0 mm 100 mm, 2.7 µm 459 bar Figure 4. Comparing 1.8 and 3.5-µm Agilent ZORBAX Eclipse Plus C18 and 2.7-µm Agilent Poroshell 120 EC-C18 columns using an Agilent 1290 Infinity LC. 6

Method Transfer with Different Agilent Detectors Selectivity is maintained when transferring this method from an Agilent 1290 Infinity LC with UV detection to a 1290 Infinity LC with MS detection, shown in Figure 5. Some peak broadening occurs with the MS due to more extra column volume in the detector, as compared to the DAD. Additionally, extra transfer tubing connecting the LC and MS accounts for the increase in system pressure and the slightly later elution time of all peaks. Increasing Analysis Speed Due to the highly selective nature of MS detection analysis speed can be increased to take full advantage of the high pressure limit of the RRHD column and the low back pressure generated by the Agilent Poroshell 120 column. With a 50 mm RRHD column, analysis time is increased significantly, resulting in a 0.4 minute run time for the 15 compounds, as seen in Figure 6. Instrument Agilent 1290 Infinity LC 645 bar Instrument Agilent 1290/6410 Infinity LC/MS/MS 657 bar Figure 5. 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 min Comparing Agilent 1290 Infinity LC with UV detection with the Agilent 1290/6410 Infinity LC/MS/MS, using an Agilent ZORBAX RRHD Eclipse Plus C18 3.0 mm 100 mm, 1.8-µm column. 10 2 1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38 Counts (%) vs. acquisition time (min) 10 2 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 Figure 6. 1 1 1 Agilent ZOBAX RRHD Eclipse Plus C18 3.0 mm 50 mm, 1.8 µm 2.75 ml/min 0.27 min 1072 bar Agilent Poroshell 120 EC-C18 3.0 mm 50 mm, 2.7 µm 2.25 ml/min 0.33 min 582 bar 0.02 0.06 0.1 0.14 0.18 0.22 0.26 0.3 0.34 0.38 0.42 0.46 Counts (%) vs. acquisition time (min) High-throughput methods with an Agilent 1290/6410 Infinity LC/MS/MS. (Note that these analyses were performed for demonstration purposes only, as it is not recommended to use such high flow rates with MS detection.) 7

Agilent s on a non-agilent Instrument Agilent s RRHD columns can be run not only with the Agilent 1290 Infinity LC, but also with a non-agilent UHPLC system. The overall analysis is similar, but some slight modification would help resolve the last peak, ibuprofen. Smaller id capillary tubing in the non-agilent UHPLC is probably the cause of increased system pressure and reduced delay volume, causing all peaks to elute earlier, as seen in Figure 7. The separation on the two instruments could be made more similar by adding either an isocratic hold to the beginning of the method on the non- Agilent LC or by adding additional capillary tubing to the non- Agilent LC to delay the gradient. Instrument Agilent 1290 Infinity LC 657 bar Instrument non-agilent UHPLC 754 bar 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 min Figure 7. Using an Agilent ZORBAX RRHD Eclipse Plus C18 3.0 mm 100 mm, 1.8-µm column to compare separation performance on an Agilent 1290 Infinity LC and a non-agilent UHPLC. 8

Conclusions Agilent ZORBAX columns offer the same selectivity across multiple particle sizes, including 5, 3.5 and 1.8 µm. The Agilent Poroshell 120 column has similar selectivity to the Agilent ZORBAX columns, with efficiency close to that provided by 1.8-µm particles, while generating substantially lower pressure due to its larger 2.7-µm particles. Scaling gradient methods according to column volume preserves selectivity when transferring methods, and methods can be easily transferred from Agilent 1200 Series RRLC systems to Agilent 1290 Infinity LC systems. Investigate ISET for more information on new technology from Agilent that makes this process easier. Transferring methods to MS is easy, as it has no significant effect on the chromatography, other than a small increase in extra-column volume. Using MS detection delivers fast analyses because of its more selective nature when detecting co-eluting peaks. Agilent ZORBAX RRHD columns, with their 1200 bar pressure limits, are easy to run on a non-agilent UHPLC without significant method modification. For More Information For more information on our products and services, visit our Web site at www.agilent.com/chem. 9

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. For Research Use Only. Not for use in diagnostic procedures. Agilent Technologies, Inc., 2011, 2017 Printed in the USA April 10, 2017 5990-8428EN