A. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for each product.

Similar documents
ROOF REPLACEMENT AND ALTERATIONS TO WOODSTOCK Barrett Architecture, PC WASTE WATER TREATMENT FACILITY - Woodstock, VT February 28, 2019 SECTION

SECTION PENETRATION FIRESTOPPING PART 1- GENERAL PART 2- PRODUCTS 1.1 RELATED DOCUMENTS

A. This Section includes joint sealants for the following applications, including those specified by reference to this Section:

SUNY GENESEO RED JACKET DINING HALL RENOVATION SECTION JOINT SEALANTS

PROJECT NO August 19, 2014 SENATE CHAMBER MEZZANINE RENOVATION MISSOURI STATE CAPITOL BUILDING SECTION JOINT SEALANTS

A. Product Data: For each joint-sealant product indicated. D. Joint-Sealant Schedule: Include the following information:

SECTION JOINT SEALERS 1.03 THIS SECTION INCLUDES JOINT SEALERS FOR THE FOLLOWING LOCATIONS:

Union County Vocational - Technical Schools Scotch Plains, New Jersey

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

CR# Issued Date: June 14, 2016 Waterville, OH

SECTION JOINT SEALANTS

c. Do not include spray applied insulation products or vapor retarders. a. All paints, coatings, spray insulation, adhesives or adhesive primers.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

PART 1- GENERAL MISSOURI ARMY NATIONAL GUARD MISCELLANEOUS INTERIOR AND EXTERIOR REPAIRS CARTHAGE, MO T

Drawings, General Conditions and Supplementary General Conditions and other Division-1 Specification Sections, apply to this Section.

THERMAL INSULATION

SECTION THERMAL INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Construction Standards PAGE

Construction Standards PAGE

SECTION JOINT SEALANTS PART 1 - GENERAL

A. Section Includes: B. Proceed with installation only after unsatisfactory conditions have been corrected.

B. Preconstruction Field-Adhesion Testing: Before installing sealants, field test their adhesion to Project joint substrates as follows:

A. Source Limitations: Obtain each type of building insulation through one source.

SECTION JOINT SEALANTS PART 1 - GENERAL 1.01 RELATED DOCUMENTS

C. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for each product.

A. Testing Agency Qualifications: Qualified according to ASTM C I 021 to conduct the testing indicated.

A. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for each product.

SECTION PIBERGLAS REINFORCED PLASTIC PANELING

SECTION SEALANTS AND CAULKING

1. Division 15 Sections specifying duct and piping penetrations. 2. Division 16 Sections specifying cable and conduit penetrations.

PART 1 GENERAL JOINT SEALANTS

2. Gj-type substrates: Glass and transparent plastic glazing sheets. 3. A-type substrates: Metals, porcelain, glazed tile, and smooth plastics.

SECTION JOINT SEALANTS

A. Section includes traffic coatings and pavement markings for the following applications: 1. Vehicular traffic.

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING

Excel Medical Waste - Equipment Installation Section SECTION JOINT SEALANTS

SECTION JOINT SEALANTS. A. Preparation of substrate surfaces to receive sealants.

SECTION (07920) - JOINT SEALANTS

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION #05-221C 2012

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

1. Building insulation in batt form. 2. Rigid board insulation. 3. Cavity wall insulation.

Spec. Standard: 08/31/ Revision: 09/28/07

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

SECTION THERMAL INSULATION

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

SECTION JOINT SEALANTS

SECTION (07200) - THERMAL PROTECTION

SECTION JOINT SEALERS

A. ASTM C203: Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation

THERMAL AND MOISTURE PROTECTION

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

SECTION JOINT SEALANTS

SECTION GLAZING

SECTION DAMPPROOFING AND WATERPROOFING

SECTION JOINT SEALANTS

B. Mirror glass for toilet rooms is specified in Section "Toilet Accessories."

Bid Opportunity Pacific Avenue, Winnipeg, Manitoba Page 1..1 CGSB 51-GP-23M-[78] Thermal Insulation, Urethane, Spray in Place.

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

A. This Section includes duct and plenum insulation; accessories and attachments; and sealing compounds.

EcoTouch Insulation with PureFiber Technology

SECTION THERMAL INSULATION

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Section Roof/Ceiling Thermal Insulation

Thermal Insulation

SECTION GYPSUM BOARD

Guide Specification for the OSI QUAD Window and Door Flashing System

A. This specification describes the sealing of vertical joints/cracks with a one-component, gungrade, elastomeric sealants. B.

PROJ. NO SECTION HVAC DUCT INSULATION

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

FIRE STATION 55 June 14, 2010

THERMAL AND MOISTURE PROTECTION

Dist. by: BEST MATERIALS Ph:

SECTION ACOUSTICAL PANEL CEILINGS

A. This Section includes traffic coatings for the following applications:

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION THERMAL INSULATION

SECTION GLAZING ADDENDUM 10 APRIL 20, 2011

THERMAL INSULATION


Student Services & Classroom Addition

Bid Opportunity No Section Winnipeg, Manitoba Page 1

ARCH 478 OFFICE BUILDING SECTION GLAZING

SECTION (07100) - DAMPPROOFING AND WATERPROOFING

CDBG Downtown Revitalization Façade Master Plan Project No / Chariton, Iowa May 2015 SECTION FIBER-CEMENT SIDING

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 07 Thermal and Moisture Protection 8400 Firestopping

Union County Vocational - Technical Schools Scotch Plains, New Jersey

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

1.6 QUALITY ASSURANCE A. Source Limitations for Tile: Obtain tile of each type and color or finish from one source or producer.

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

St. Monica Food Pantry

PART 1 - GENERAL SECTION JOINT SEALANTS 1.1 SUMMARY

SECTION PRE-ENGINEERED BUILDING INSULATION

Blair Building Office Renovation - Sexual Offender Treatment Services (SORTS) M BA#16026 SECTION FIRESTOPPING

TILING Lutheran Church of the Holy Spirit

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

FIRESTOPPING & SMOKE SEALS

SECTION FIRE RESISTIVE JOINT SYSTEMS

Transcription:

SECTION 072100 - THERMAL INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Glass-fiber blanket insulation. 1.3 ACTION SUBMITTALS A. Product Data: For each type of product indicated. 1.4 INFORMATIONAL SUBMITTALS A. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for each product. B. Research/Evaluation Reports: For foam-plastic insulation 1.5 QUALITY ASSURANCE A. Surface-Burning Characteristics: As determined by testing identical products according to ASTM E 84 by a qualified testing agency. Identify products with appropriate markings of applicable testing agency. 1.6 DELIVERY, STORAGE, AND HANDLING A. Protect insulation materials from physical damage and from deterioration due to moisture, soiling, and other sources. Store inside and in a dry location. Comply with manufacturer's written instructions for handling, storing, and protecting during installation. B. Protect foam-plastic board insulation as follows: 1. Do not expose to sunlight except to necessary extent for period of installation and concealment. 2. Protect against ignition at all times. Do not deliver foam-plastic board materials to Project site before installation time. 3. Quickly complete installation and concealment of foam-plastic board insulation in each area of construction. THERMAL INSULATION 1346 072100-1

PART 2 - PRODUCTS 2.1 GLASS-FIBER BLANKET INSULATION A. Available Manufacturers: 1. CertainTeed Corporation. 2. Guardian Fiberglass, Inc. 3. Johns Manville. 4. Knauf Fiber Glass. 5. Owens Corning. B. Unfaced, Glass-Fiber Blanket Insulation: ASTM C 665, Type I (blankets without membrane facing); consisting of fibers; with maximum flame-spread and smoke-developed indexes of 25 and 50, respectively; passing ASTM E 136 for combustion characteristics. C. Faced, Glass-Fiber Blanket Insulation: ASTM C 665, Type III (blankets with reflective membrane facing), Class A (membrane-faced surface with a flame-spread index of 25 or less); Category 1 (membrane is a vapor barrier), faced with foil-scrim-kraft, foil-scrim, or foil-scrimpolyethylene vapor-retarder membrane on 1 face. D. Where glass-fiber blanket insulation is indicated by the following thicknesses, provide blankets in batt or roll form with thermal resistances indicated: 1. 3-5/8 inches thick with a thermal resistance of 11 deg F x h x sq. ft./btu at 75 deg F. 2. 5-1/2 inches thick with a thermal resistance of 19 deg F x h x sq. ft./btu at 75 deg F. 3. 9-1/2 inches thick with a thermal resistance of 30 deg F x h x sq. ft./btu at 75 deg F. 2.2 INSULATION FASTENERS A. Adhesively Attached, Spindle-Type Anchors: Plate welded to projecting spindle; capable of holding insulation of thickness indicated securely in position indicated with self-locking washer in place; and complying with the following requirements: 1. Available Products: a. AGM Industries, Inc.; Series T TACTOO Insul-Hangers. b. Eckel Industries of Canada; Stic-Klip Type N Fasteners. c. Gemco; Spindle Type. 2. Plate: Perforated galvanized carbon-steel sheet, 0.030 inch thick by 2 inches square. 3. Spindle: Copper-coated, low carbon steel; fully annealed; 0.105 inch in diameter; length to suit depth of insulation indicated. B. Anchor Adhesive: Product with demonstrated capability to bond insulation anchors securely to substrates indicated without damaging insulation, fasteners, and substrates. 1. Available Products: a. AGM Industries, Inc.; TACTOO Adhesive. b. Eckel Industries of Canada; Stic-Klip Type S Adhesive. c. Gemco; Tuff Bond Hanger Adhesive. THERMAL INSULATION 1346 072100-2

PART 3 - EXECUTION 3.1 PREPARATION A. Clean substrates of substances that are harmful to insulation or vapor retarders, including removing projections capable of puncturing vapor retarders, or that interfere with insulation attachment. 3.2 INSTALLATION, GENERAL A. Comply with insulation manufacturer's written instructions applicable to products and application indicated. B. Install insulation that is undamaged, dry, and unsoiled and that has not been left exposed at any time to ice, rain, and snow. C. Extend insulation in thickness indicated to envelop entire area to be insulated. Cut and fit tightly around obstructions and fill voids with insulation. Remove projections that interfere with placement. D. Water-Piping Coordination: If water piping is located within insulated exterior walls, coordinate location of piping to ensure that it is placed on warm side of insulation and insulation encapsulates piping. E. For preformed insulating units, provide sizes to fit applications indicated and selected from manufacturer's standard thicknesses, widths, and lengths. Apply single layer of insulation units to produce thickness indicated unless multiple layers are otherwise shown or required to make up total thickness. 3.3 INSTALLATION OF GENERAL BUILDING INSULATION A. Apply insulation units to substrates by method indicated, complying with manufacturer's written instructions. If no specific method is indicated, bond units to substrate with adhesive or use mechanical anchorage to provide permanent placement and support of units. B. Seal joints between foam-plastic insulation units by applying adhesive, mastic, or sealant to edges of each unit to form a tight seal as units are shoved into place. Fill voids in completed installation with adhesive, mastic, or sealant as recommended by insulation manufacturer. C. Set vapor-retarder-faced units with vapor retarder to warm-in-winter side or in location indicated of construction, unless otherwise indicated. 1. Tape joints and ruptures in vapor retarder, and seal each continuous area of insulation to surrounding construction to ensure airtight installation. D. Install mineral-fiber insulation in cavities formed by framing members according to the following requirements: 1. Use insulation widths and lengths that fill the cavities formed by framing members. If more than one length is required to fill cavity, provide lengths that will produce a snug fit between ends. THERMAL INSULATION 1346 072100-3

2. Place insulation in cavities formed by framing members to produce a friction fit between edges of insulation and adjoining framing members. 3. Maintain 3-inch clearance of insulation around recessed lighting fixtures. 4. For metal-framed wall cavities where cavity heights exceed 96 inches, support unfaced blankets mechanically and support faced blankets by taping flanges of insulation to flanges of metal studs. E. Install board insulation on concrete substrates by adhesively attached, spindle-type insulation anchors as follows: 1. Fasten insulation anchors to concrete substrates with insulation anchor adhesive according to anchor manufacturer's written instructions. Space anchors according to insulation manufacturer's written instructions for insulation type, thickness, and application indicated. 2. After adhesive has dried, install board insulation by pressing insulation into position over spindles and securing it tightly in place with insulation-retaining washers, taking care not to compress insulation below indicated thickness. 3. Where insulation will not be covered by other building materials, apply capped washers to tips of spindles. F. Stuff glass-fiber loose-fill insulation into miscellaneous voids and cavity spaces where shown. Compact to approximately 40 percent of normal maximum volume equaling a density of approximately 2.5 lb/cu. ft. 3.4 INSTALLATION OF INSULATION IN CEILINGS FOR SOUND ATTENUATION A. Install 3-inch- thick, unfaced glass-fiber blanket insulation over suspended ceilings at partitions in a width that extends insulation 48 inches on either side of partition. 3.5 PROTECTION A. Protect installed insulation and vapor retarders from damage due to harmful weather exposures, physical abuse, and other causes. Provide temporary coverings or enclosures where insulation is subject to abuse and cannot be concealed and protected by permanent construction immediately after installation. END OF SECTION 072100 THERMAL INSULATION 1346 072100-4

SECTION 079200 - JOINT SEALANTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Silicone joint sealants. 2. Latex joint sealants. B. Related Requirements: 1. Section 088000 "Glazing" for glazing sealants. 2. Section 321373 "Concrete Paving Joint Sealants" for sealing joints in paved roads, parking lots, walkways, and curbing. 1.3 ACTION SUBMITTALS A. Product Data: For each joint-sealant product. B. Samples for Initial Selection: Manufacturer's color charts consisting of strips of cured sealants showing the full range of colors available for each product exposed to view. 1.4 INFORMATIONAL SUBMITTALS A. Sample Warranties: For special warranties. 1.5 QUALITY ASSURANCE A. Installer Qualifications: An authorized representative who is trained and approved by manufacturer. B. Source Limitations: Obtain each type of joint sealant through one source from a single manufacturer. 1.6 FIELD CONDITIONS A. Do not proceed with installation of joint sealants under the following conditions: 1. When ambient and substrate temperature conditions are outside limits permitted by jointsealant manufacturer or are below 40 deg F. JOINT SEALANTS 1346 079200-1

2. When joint substrates are wet. 3. Where joint widths are less than those allowed by joint-sealant manufacturer for applications indicated. 4. Where contaminants capable of interfering with adhesion have not yet been removed from joint substrates. 1.7 WARRANTY A. Special Installer's Warranty: Installer agrees to repair or replace joint sealants that do not comply with performance and other requirements specified in this Section within specified warranty period. 1. Warranty Period: Two <2> years from date of Substantial Completion. B. Special Manufacturer's Warranty: Manufacturer agrees to furnish joint sealants to repair or replace those joint sealants that do not comply with performance and other requirements specified in this Section within specified warranty period. 1. Warranty Period: Twenty <20> years from date of Substantial Completion. C. Special warranties specified in this article exclude deterioration or failure of joint sealants from the following: 1. Movement of the structure caused by stresses on the sealant exceeding sealant manufacturer's written specifications for sealant elongation and compression. 2. Disintegration of joint substrates from causes exceeding design specifications. 3. Mechanical damage caused by individuals, tools, or other outside agents. 4. Changes in sealant appearance caused by accumulation of dirt or other atmospheric contaminants. PART 2 - PRODUCTS 2.1 JOINT SEALANTS, GENERAL A. Compatibility: Provide joint sealants, backings, and other related materials that are compatible with one another and with joint substrates under conditions of service and application, as demonstrated by joint-sealant manufacturer, based on testing and field experience. B. Colors of Exposed Joint Sealants: As selected by Architect from manufacturer's full range. 2.2 ELASTOMERIC JOINT SEALANTS A. Elastomeric Sealants: Comply with ASTM C 920 and other requirements indicated for each liquid-applied chemically curing sealant specified, including those referencing ASTM C 920 classifications for type, grade, class, and uses related to exposure and joint substrates. B. Stain-Test-Response Characteristics: Where elastomeric sealants are specified to be nonstaining to porous substrates, provide products that have undergone testing according to ASTM C 1248 and have not stained porous joint substrates indicated for Project. JOINT SEALANTS 1346 079200-2

C. Suitability for Contact with Food: Where elastomeric sealants are indicated for joints that will come in repeated contact with food, provide products that comply with 21 CFR 177.2600. D. Single-Component Neutral-Curing Silicone Sealant ES-1: 1. Available Products: a. Dow Corning Corporation; 790. b. GE Silicones; SilPruf LM SCS2700. c. Tremco; Spectrem 1 (Basic). d. GE Silicones; SilPruf SCS2000. e. Pecora Corporation; 864. f. Pecora Corporation; 890. g. Polymeric Systems Inc.; PSI-641. h. Sonneborn, Division of ChemRex Inc.; Omniseal. i. Tremco; Spectrem 3. 2. Type and Grade: S (single component) and NS (nonsag). 3. Class: 50. 4. Use Related to Exposure: NT (nontraffic). 5. Uses Related to Joint Substrates: M, G, A, and, as applicable to joint substrates indicated, O. a. Use O Joint Substrates: Coated glass, color anodic aluminum, aluminum coated with a high-performance coating, galvanized steel, and brick. 6. Stain-Test-Response Characteristics: Nonstaining to porous substrates per ASTM C 1248. 7. Applications: Exterior expansion joints, joints at perimeter of windows, doors and wall systems and other joints indicated. E. Single-Component Mildew-Resistant Neutral-Curing Silicone Sealant ES-2: 1. Available Products: a. Pecora Corporation; 898. b. Tremco; Tremsil 600 White. 2. Type and Grade: S (single component) and NS (nonsag). 3. Class: 25. 4. Use Related to Exposure: NT (nontraffic). 5. Uses Related to Joint Substrates: M, G, A, and, as applicable to joint substrates indicated, O. a. Use O Joint Substrates: Glass, anodic aluminum and ceramic tile. 6. Applications: Joints around toilet fixtures, countertops and casework. F. Single-component Nonsag Urethane Sealant ES-3: 1. Available Products: a. Sika Corporation, Inc.; Sikaflex 1a. b. Sika Corporation, Inc.; Sikaflex -15LM. c. Sonneborn, Division of ChemRex Inc.; Ultra. d. Sonneborn, Division of ChemRex Inc.; NP 1. e. Tremco; Vulkem 116. JOINT SEALANTS 1346 079200-3

2. Type and Grade: S (single component) and NS (nonsag). 3. Class: 25 or 100/50. 4. Use Related to Exposure: NT (nontraffic). 5. Uses Related to Joint Substrates: M, G, A, and, as applicable to joint substrates indicated, O. a. Use O Joint Substrates: Galvanized metal wall panels with high-performance coatings. 6. Applications: Joints in metal wall panel systems. 2.3 LATEX JOINT SEALANTS A. Latex Sealant LS-1: Comply with ASTM C 834, Type OP, Grade NF. B. Available Products: 1. Bostik Findley; Chem-Calk 600. 2. Pecora Corporation; AC-20+. 3. Schnee-Morehead, Inc.; SM 8200. 4. Sonneborn, Division of ChemRex Inc.; Sonolac. 5. Tremco; Tremflex 834. 2.4 JOINT-SEALANT BACKING A. General: Provide sealant backings of material and type that are nonstaining; are compatible with joint substrates, sealants, primers, and other joint fillers; and are approved for applications indicated by sealant manufacturer based on field experience and laboratory testing. B. Cylindrical Sealant Backings: ASTM C 1330, Type C (closed-cell material with a surface skin), and of size and density to control sealant depth and otherwise contribute to producing optimum sealant performance: C. Bond-Breaker Tape: Polyethylene tape or other plastic tape recommended by sealant manufacturer for preventing sealant from adhering to rigid, inflexible joint-filler materials or joint surfaces at back of joint where such adhesion would result in sealant failure. Provide selfadhesive tape where applicable. 2.5 MISCELLANEOUS MATERIALS A. Primer: Material recommended by joint-sealant manufacturer where required for adhesion of sealant to joint substrates indicated, as determined from preconstruction joint-sealant-substrate tests and field tests. B. Cleaners for Nonporous Surfaces: Chemical cleaners acceptable to manufacturers of sealants and sealant backing materials, free of oily residues or other substances capable of staining or harming joint substrates and adjacent nonporous surfaces in any way, and formulated to promote optimum adhesion of sealants to joint substrates. C. Masking Tape: Nonstaining, nonabsorbent material compatible with joint sealants and surfaces adjacent to joints. JOINT SEALANTS 1346 079200-4

PART 3 - EXECUTION 3.1 EXAMINATION A. Examine joints indicated to receive joint sealants, with Installer present, for compliance with requirements for joint configuration, installation tolerances, and other conditions affecting jointsealant performance. B. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Surface Cleaning of Joints: Clean out joints immediately before installing joint sealants to comply with joint-sealant manufacturer's written instructions and the following requirements: 1. Remove all foreign material from joint substrates that could interfere with adhesion of joint sealant, including dust, paints (except for permanent, protective coatings tested and approved for sealant adhesion and compatibility by sealant manufacturer), old joint sealants, oil, grease, waterproofing, water repellents, water, surface dirt, and frost. 2. Clean porous joint substrate surfaces by brushing, grinding, blast cleaning, mechanical abrading, or a combination of these methods to produce a clean, sound substrate capable of developing optimum bond with joint sealants. Remove loose particles remaining after cleaning operations above by vacuuming or blowing out joints with oil-free compressed air. Porous joint substrates include the following: a. Concrete. b. Masonry. 3. Remove laitance and form-release agents from concrete. 4. Clean nonporous surfaces with chemical cleaners or other means that do not stain, harm substrates, or leave residues capable of interfering with adhesion of joint sealants. Nonporous joint substrates include the following: a. Metal. b. Glass. c. Porcelain enamel. d. Glazed surfaces of ceramic tile. B. Joint Priming: Prime joint substrates, where recommended in writing by joint-sealant manufacturer, based on preconstruction joint-sealant-substrate tests or prior experience. Apply primer to comply with joint-sealant manufacturer's written instructions. Confine primers to areas of joint-sealant bond; do not allow spillage or migration onto adjoining surfaces. C. Masking Tape: Use masking tape where required to prevent contact of sealant with adjoining surfaces that otherwise would be permanently stained or damaged by such contact or by cleaning methods required to remove sealant smears. Remove tape immediately after tooling without disturbing joint seal. 3.3 INSTALLATION OF JOINT SEALANTS A. General: Comply with joint-sealant manufacturer's written installation instructions for products and applications indicated, unless more stringent requirements apply. JOINT SEALANTS 1346 079200-5

B. Sealant Installation Standard: Comply with recommendations in ASTM C 1193 for use of joint sealants as applicable to materials, applications, and conditions indicated. C. Install sealant backings of type indicated to support sealants during application and at position required to produce cross-sectional shapes and depths of installed sealants relative to joint widths that allow optimum sealant movement capability. 1. Do not leave gaps between ends of sealant backings. 2. Do not stretch, twist, puncture, or tear sealant backings. 3. Remove absorbent sealant backings that have become wet before sealant application and replace them with dry materials. D. Install bond-breaker tape behind sealants where sealant backings are not used between sealants and backs of joints. E. Install sealants using proven techniques that comply with the following and at the same time backings are installed: 1. Place sealants so they directly contact and fully wet joint substrates. 2. Completely fill recesses in each joint configuration. 3. Produce uniform, cross-sectional shapes and depths relative to joint widths that allow optimum sealant movement capability. F. Tooling of Nonsag Sealants: Immediately after sealant application and before skinning or curing begins, tool sealants according to requirements specified below to form smooth, uniform beads of configuration indicated; to eliminate air pockets; and to ensure contact and adhesion of sealant with sides of joint. 1. Remove excess sealant from surfaces adjacent to joints. 2. Use tooling agents that are approved in writing by sealant manufacturer and that do not discolor sealants or adjacent surfaces. 3. Provide concave joint configuration per Figure 5A in ASTM C 1193, unless otherwise indicated. 4. Provide flush joint configuration where indicated per Figure 5B in ASTM C 1193. a. Use masking tape to protect surfaces adjacent to recessed tooled joints. 3.4 CLEANING A. Clean off excess sealant or sealant smears adjacent to joints as the Work progresses by methods and with cleaning materials approved in writing by manufacturers of joint sealants and of products in which joints occur. 3.5 PROTECTION A. Protect joint sealants during and after curing period from contact with contaminating substances and from damage resulting from construction operations or other causes so sealants are without deterioration or damage at time of Substantial Completion. If, despite such protection, damage or deterioration occurs, cut out and remove damaged or deteriorated joint sealants immediately so installations with repaired areas are indistinguishable from original work. JOINT SEALANTS 1346 079200-6

3.6 JOINT-SEALANT SCHEDULE A. Joint-Sealant Application JS-1: Exterior vertical construction joints in cast-in-place concrete. 1. Joint Sealant: Single-component neutral-curing silicone sealant ES-1. B. Joint-Sealant Application JS-4: Exterior vertical construction joints in masonry. 1. Joint Sealant: Single-component neutral-curing silicone sealant ES-1. C. Joint-Sealant Application JS-7: Exterior joints between metal panels. 1. Joint Sealant: Single-component neutral-curing silicone sealant ES-3. D. Joint-Sealant Application JS-8: Exterior vertical joints between different materials listed above. 1. Joint Sealant: Single-component neutral-curing silicone sealant ES-1. E. Joint-Sealant Application JS-9: Exterior perimeter joints around frames of doors, windows, and louvers. 1. Joint Sealant: Single-component neutral-curing silicone sealant ES-1. F. Joint-Sealant Application JS-11: Vertical control and expansion joints on exposed interior surfaces of exterior walls. 1. Joint Sealant: Latex sealant LS-1. G. Joint-Sealant Application JS-12: Interior perimeter joints around doors and windows in exterior openings. 1. Joint Sealant: Latex sealant LS-1. H. Joint-Sealant Application JS-13: Interior joints between plumbing fixtures and adjoining walls, floors, and counters. 1. Joint Sealant: Single-component mildew-resistant neutral-curing silicone sealant ES-2. I. Joint-Sealant Application JS-15: Perimeter joints between interior wall surfaces and frames of interior doors, windows, and elevator entrances. 1. Joint Sealant: Latex sealant LS-1. END OF SECTION 079200 JOINT SEALANTS 1346 079200-7