Corrugated modular panel of U.V. protected multiwall polycarbonate for windows and translucent roofing, continuous or installed with corrugated insulating panels The arcoplus 1000 system has been awarded: TEST 1200Joule ACCIDENTAL SHOCK RESISTANCE arcoplus 1000 is a modular system used in civil and industrial construction for: Gutter ridge skylights: as perfectly superimposable to all main types of corrugated insulating panels (min. slope 5%); Continuous translucent covers: of considerable size (min.slope 7%); Curved translucent covers: (radius 3.300 and 6.000mm); Transparent vertical walls. Composed of double-wall coextruded (U.V. protected) polycarbonate panels with a variable thickness of 7-10mm, module width 1.000mm and profile height 80mm. U.V. side SPECIFICATIONS Covering/wall made with modular multi wall coextruded polycarbonate panels (protected U.V.) with a variable thickness of 7-10mm, module width 1.000mm, maximum length 5.000mm. Panels can be overlapped. Thermal transmission coefficient K= 3,4 W/m 2 K. APPLICATIONS PRODUCTION STANDARDS Thickness Profile height Structure Modular width variable 7 10mm 80 mm 2 walls 1.000 mm TECHNICAL FEATURES UV rays protection Coextrusion Thermal transmittance 2,9 Kcal/hm 2 C - 3,4 W/m 2 C Light transmission 76% (satin crystal) - 55% (satin opal) Linear thermal expansion 6,5 x 10-5 m/m C - (0,065mm/m C) Use temperature -40 C+120 C Fire reaction CLASSE 1 (italian) Accidental shock resistance 1.200 Joule Skylight ridge-eaves Continuous coverings Vertical walls Skylights and curved coverings "ADVANTAGES" HIGH LOAD RESISTANCE The greca corrugated profile confers a high load resistance to the panel. LONGITUDINAL SUPERIMPOSITION The arcoplus 1000 system is perfectly superimposable to all main types of foamed panels for covering. TRANSVERSAL SURMOUNT arcoplus 1000 panels are perfectly suitable to be installed one upon the other, and allow ridge-eaves covers even of considerable size (Max. length 5.000mm). This feature always ensures a perfect hold of the translucent elements, reducing the negative effects of thermal dilatation. PANEL WELDING The arcoplus 1000 profile is supplied welded at the ends. LIGHT TRANSMISSION SOLAR FACTOR RESISTANCE TO UV RAYS AND TO HAIL THERMAL ISOLATION (See section "general characteristic of product" page 6/7) COLOUR cod. arcoplus 1000 Satin Crystal 2154/5028 Satin Opal 2154/5015 32

APPLICATION OF SKYLIGHT RIDGE-EAVES Laterally overlapping panels with metallic profiled panels for covering. Minimum slope 5%. DETAIL PANEL JOINT LOAD RESISTANCE Top detail city, for longitudinally overlapping panels with two covering panels, fixed on more than two supports. superimposition detail Max loads arcoplus 1000 SKYLIGHTS (plane) on more supports-rise 1/50 LOADS (dan/mq) Roof gutter detail Distance between supports (m) The choice of the distance between supports should be made in relation to the capacity values required. The table below shows values of capaanchorage roof gutter detail 33

APPLICATION ON CONTINUOUS COVERINGS Continual covering application, with continuous lateral overlapping of the elements. Minimum slope 7%. LOAD RESISTANCE The choice of the distance between supports is a function of the values of resistance to the wind-thrust required. Table below shows the value of the capacity, for longitudinally overlapped profiles, fixed on more than two supports. DETAIL PANEL JOINT Max loads arcoplus 1000 CONTINUOUS COVERING-WINDOWS on more supports-rise 1/50 LOADS (dan/mq) Distance between supports (m) Values below refer to product installed according to the Technical Handbook Recommendation APPLICATION ON VERTICAL WALL Vertical wall application, with lateral continuous overlapping of the elements. 34

CURVED TRANSLUCENT COVER APPLICATION Curved covering is obtained with continuous lateral overlapping of the elements, or with curved insulating panels with radius R.3.300mm or R.6.000mm PANEL DEVELOPMENT RISE LATERAL OVERHANG EXTERNAL WALLS SPAN LATERAL OVERHANG LOAD RESISTANCE The choice of the distance between supports is a function of the values of resistance to the wind-thrust required. The table below shows the value of the capacity, for longitudinally overlapped profiles, fixed on extremities in correspondance to all greca panels. UTILIZATION: To install with insulating panels (skylight): max light 5.000mm Continous coverings: max light 3.500mm RADIUS 3.300mm COLOUR cod. arcoplus 1000 Satin Crystal 2162/5028 Satin Opal 2162/5015 RADIUS 6.000mm COULOUR cod. arcoplus 1000 Satin Crystal 2163/5028 Satin Opal 2163/5015 Max loads arcoplus 1000 BENDED R.3.300mm - R. 6.000mm on two supports - rise 1/50 LOAD (dan/mq) CONTINUOUS COVERINGS MAX SPAN (metres) Values below refer to product installed according to the Technical Handbook Recommendation DEVELOPMENT TABLE RADIUS 3.300mm RADIUS 6.000mm SPAN (LIGHT) RISE DEVELOPMENT RISE DEVELOPMENT 1.000 38 1.016 21 1.008 1.200 55 1.221 30 1.231 1.400 75 1.428 41 1.413 1.600 98 1.635 54 1.616 1.800 125 1.845 68 1.820 2.000 155 2.056 84 2.024 2.200 189 2.270 102 2.228 2.400 226 2.486 121 2.434 2.600 267 2.704 143 2.640 2.800 312 2.926 166 2.846 3.000 361 3.151 191 3.054 3.200 414 3.380 217 3.263 3.400 472 3.613 246 3.472 3.600 534 3.851 276 3.683 3.800 602 4.095 309 3.895 4.000 675 4.345 343 4.108 4.200 754 4.601 380 4.322 4.400 840 4.867 418 4.538 4.600 935 5.141 458 4.756 4.800 1.035 5.426 501 4.975 35 SKYLIGHT "STRONG POINTS" SUPERPOSITION LONGITUDINALE Due to their innovative design the profiles adapt to all main types of isolating panels for coverings. ACCIDENTAL SHOCK RESISTANCE (Test 1.200 Joule) Sample testing: fall of 50Kg weight from a 2.400mm high; Test validated from control office SOCOTEC (France).

ACCESSORIES arcoplus 1000, is a complete system for the construction of transparent wall and coverings with a series of accessories for all purposes. In addition, the system comes with a complete group of fixing elements, a "tongue and groove connection, a plane connection for resistance in the overlapped areas, and steel accessories used as bracing brackets to increase load resistance, and a special profile to install in the reinforcement area, in correspondance of the groove side of the panel. A flat profile to put adjacent to the other profiles completes the set of accessories. Panels are normally delivered with thermowelded sides. Alu. cap with gasket Cod. 4234 Fixing screw 6,3 x 120 Cod. 4233 Gasket M/F (2 pieces) Cod. 4229 SILICONE PRODUCTS Use of policarbonate compatible silicone products is recommended only in case of increased water proof reliability, reduced slope, windy areas or if air tight and dust proof conditions, are needed. Gasket for gutter Cod. 4250 Protected steel profile Cod. 4236 Sealant tape PE 20x10 Cod. 4232 Central bracing bracket Cod. 4235 Roof profile (2 pieces) Cod. 4231 36