GAS DETECTION SYSTEMS

Similar documents
A World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...

3M Meridian Sensor Specifications

EQUIPMENT AND SERVICE COMPANY, INCORPORATED FX- 300 ISE Ammonia, Nitrate, Nitrite Measurement

Sensor Cartridge SC2 for toxic gases and oxygen

Sensor Cartridge SC2 for toxic gases and oxygen

Sensor unit MC2 for toxic gases and oxygen with analog output

X-Change Gas Sensor Cartridges. PolyGard 2 SC2

ECD Analytical. Your Liquid Measurement Expert. Industrial Water Analyzers and Liquid Analytical Products

Technical Note TN-114 rev 16 wy/wh.11-04

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument

Crowcon Technical Note

Crowcon Technical Note

Q45WQ. Water Quality Monitoring System. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

INNOVA. Innova. Innova FV. Innova LS. Innova SV. Innova XT. Portable Gas Monitors For one, two, three or four gases. (Standard Multi Gas) (Fuel Vapor)

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

PRESSURE REGULATOR AND VALVE SELECTION GUIDE

Sensor Specifications and CroSS- Sensitivities

Complete Water Analysis Solutions for Power, Heat & Steam Generation

SENSOR SPECIFICATIONS AND CROSS-SENSITIVITIES

Turn-key packages - precise, accurate and dependable. Dosing, metering & monitoring systems

HAZ-SCANNER. Model HIM Complete Air Monitoring Station

Waspmote Plug & Sense! Quick Overview

DR1000 Flying Laboratory, Drone Environmental Monitoring

Online Gas Analyzer / Monitor

Panel Discussion on Water Monitoring for Combined Cycle Plants

CANADA UNISEARCH founded in 1980

Complete Water Analysis for POWER GENERATION

NEW!! Online Field. Laboratory. Water Testing Product Sampler Visit our Web Site

AP Chemistry Reaction Set

H2scan Market Overview

Calibration gas cylinders Calibration gas cylinders for the calibration or the periodical checkings of the gas detectors

COMBIMASS Thermal Gas Flow

AP Chemistry Reaction Set

Cyanide Concentration Changes in Environmental Water Samples as a Function of Sample Preservation, and Holding Time

Safe Handling of Import-Containers

Thermo Scientific Orion Dissolved Oxygen Probes

Cl500/Cl1000 BROCHURE

Advanced Spectroscopic Solutions for Fuel Cell Hydrogen Analysis

Causes of Corrosion and Corrosion Monitoring

ETHYLENE PLANT DRY CRACKED GAS Product Code 54801

HI Multiparameter Photometers with up to 44 Measurement Methods. ISO 9001:2000 Certified

Waspmote Plug & Sense! Quick Overview

Conex DIA-1, DIA-2, DIA-2Q

Conex DIA-1, DIA-2, DIA-2Q

Lab Design or Renovation Plans Interview/ Review

MultiRAE Pro Monitors (Model PGM-6248)

COMPANY PRODUCT PORTFOLIO

???? Spot Check Measurement Simple, accurate, reliable

ABB MEASUREMENT & ANALYTICS DATA SHEET. AW400 Residual chlorine monitor

Online. Field Laboratory. Water Testing Product Sampler HFscientific.com. Visit our Web Site HFscientific.com. Visit Us at:

RESP_IRR_20 P Package

SERIES 60 DETECTORS-TRANSMITTERS FOR FLAMMABLE, TOXIC GASES AND OXYGEN ATEX. Your environment, your safety, let s master them together

Process Monitoring of Water and Wastewater Treatment

S80 Intelligent Sensors

Hazardous Chemicals, Dangerous Goods and Explosives Storage and Transport Procedure

HI GPS Multiparameter Meter. With great products, come great results HI 9829

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

S E N S O R T E C H N O L O G Y

News. Power Generation 11. ph Control Reduces Acid Consumption in Neutralization Process up to 90 % Perspectives in Pure Water Analytics THORNTON

WATER QUALITY ANALYZERS SENSOR TECHNOLOGY. mv(orp) ION. Conductivity. Resistivity. Salinity TDS

Optimum measurement system for all types of application. Industrial Water Quality Measuring Instruments NEW. On-site (Rain-proof) type

NANOCHEM Purifiers. Complete Purification Solutions with

Portable Instrument Application Guide

Module 5: Disinfection and Chlorination Answer Key

madur GA21p-EN-v portable gas analyser

Application Note. Hydrogen Purity Analysis by FTIR PROBLEM BACKGROUND

SCOTTY Brand Transportables Convenient, Cost-Effective Calibration Gases

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

SENSOR SELECTION GUIDE

SOURCE WATER MONITORING. Taseen Karim SE PA Regional Sales Manager Greg Leininger- NE Divisional Sales Manager

Sherwood Valve Specialty Gas Products

Getting the most from your 4 gas monitor. Terri A. Pearce, PhD Emily R. T. Schmick, MSPH, CIH

半導體水質及氣體分析的革新技術 Continuous Water Analyser (CWA) & Gas Analyser

3. Add 0.4 ml of. 7. Use a TenSette

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

Chlorination/Dechlorination: An Environmental Solution

EPA APPROVES IN-SITU OPTICAL RDO METHODS

TOC SYSTEMS INC. On-Line TOC Analyzer. Features -CHOICE OF PLATFORMS- Options. Combustion ON - LINE HIGH TEMPERATURE COMBUSTION

Gas Analyzer Spare Part Recommendations

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIA-G, DIS-G. Gas warning systems for Cl2, ClO2, O3, NH3, HCl

Continous Emission Monitoring: Methods, Regulations and QA/QC. Anders Arvidsson, Opsis AB, Sweden

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic

AP* CHEMISTRY EQUATIONS BY TYPE

Draeger-Tubes and accuro Pump

Water sanitation at its best

R & R IDENTIFICATION CO.

Boeing BSS 7239 Toxic Gas Generation of "Moniflex as manufactured by Isoflex AB"

American Water College 2010

SIMPLE SOLUTIONS FOR GAS ANALYSIS ENVIRONMENTAL EQUIPMENT, INC. MADE IN USA Page 1 of 7

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

Alphasense Ltd. Compliance Statements and Certificates. Contents. The Restriction of the Use of Certain Hazardous Substances (RoHS)...

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

CO Sensor Response Study NO & NOx Analyzer Validation. June 6, 2018

Transcription:

PRODUCT GUIDE

SENSING SOLUTIONS The quality of the air we breathe and the water we drink is of basic concern to everyone. Analytical Technology is committed to developing and improving the sensing technologies that help insure the quality of the environment in which we live and work. At ATI, we specialize in the application of electrochemistry to air and water monitoring problems. Our sensors are at work 24 hours a day, 365 days a year, year after year, helping safeguard the workplace against the dangers of toxic gas emissions and improving the control of potable water and wastewater treatment. From simple analog transmitters to sophisticated microprocessor based systems, we strive to provide the reliability and durability demanded in today s market. Innovative product design with an emphasis on reduced operational maintenance is the goal in every product we offer. From our exclusive Auto-Test gas sensor verification system to our unique D.O. sensor cleaning system, we provide monitoring solutions that are reliable and cost effective. Quality product design, years of sensor development and manufacturing experience, andknowledgeable application support are an integral part of the products we offer.

GAS DETECTION SYSTEMS GAS DETECTION INSTRUMENTS Gas detection instruments are available for a variety of toxic and flammable gases as shown in the list below. Packages are available or anything from single point to large multipoint systems. NH 3 Ammonia CO Carbon Monoxide H 2 Hydrogen NO Nitric Oxide O 2 Oxygen COCl2 Phosgene Br 2 Bromine Cl 2 Chlorine ClO 2 Chlorine Dioxide F 2 Fluorine I 2 Iodine HX Acid Gases C 2 H 4 O Ethylene Oxide C 2 H 6 O Alcohol O 3 Ozone CH 4 Methane (Combustible Gas) H 2 O 2 Hydrogen Peroxide HCl Hydrogen Chloride HCN Hydrogen Cyanide HF Hydrogen Fluoride H 2 S Hydrogen Sulfide NO 2 Nitrogen Dioxide SO 2 Sulfur Dioxide H 2 Se Hydrogen Selenide B 2 H 6 Diborane GeH 4 Germane AsH 3 Arsine PH 3 Phosphine SiH 4 Silane HCHO Formaldehyde NO X Oxides of Nitrogen HC 2 H Acetylene (CH 3 ) 2 NH Dimethylamine HBr Hydrogen Bromide

GAS DETECTION SYSTEMS Modular Gas Detector GasSens Detectors provide gas measurement, display, visual and audible alarm, and analog output in a compact unit. Modular in design, these detectors are ideal for small to medium size detection applications. Detector configuration is easily customized to fit specific site requirements. 2-Wire Transmitter UniSens Gas Transmitters are the ultimate in transmitter technology. Transmitter electronics are universal, accepting up to 30 different gas sensors by simply plugging them in. And our exclusive Auto-Test sensor self-test feature reduces maintenance time to an absolute minimum. 2-Wire Transmitter Series B12 Transmitters provide an alternative for 2-wire applications. This transmitter provides fewer features than the UniSens but at a lower cost. For OEM use or installations where advanced UniSens features are not required, TranSens is an economical alternative.

For The Air We Breathe Digital Gas Transmitter Model D12 Gas Transmitters provide the ultimate in application flexibility. Loop-powered or 3-wire models with on-board relays are available, as are both combustible gas and universal toxic gas versions. In addition, digital communication using HartTM or ModbusTM protocol are available. Digital Gas Transmitter Model F12 is an intrinsically safe Gas Transmitter designed for the detection of a variety of toxic gases in hazardous locations or general purpose applications. The F12 uses ATI s smart sensors that contain all calibration constants in memory thus making calibrations possible in safe non-hazardous locations. Portable Gas Leak Detector PortaSens II leak detectors provide a flexible tool for locating the source of toxic gas leaks from storage cylinders, process machinery, gas generation equipment, or piping systems. Interchangeable sensors allow one instrument to be used for a variety of gas detection requirements, with internal data logger standard.

GAS DETECTION SYSTEMS Auto-Test Combustible Transmitter Model A12-17 Combustible Gas Transmitters are unique in their ability to perform an automatic gas response test on the combustible gas sensing elements every 24 hours. A standard 4-20 ma output signal allows application in virtually any existing installation. Wet Gas Transmitter Monitoring gas concentrations in locations where condensation is normally present requires sensors and systems designed for that type of environment. ATI offers B12 wet gas systems for monitoring halogens or hydrogen gas in condensing environments. A special Q45S wet H2S system is also available for odor scrubber monitoring. Infrared Gas Transmitter- LEL/CO2 /N2O Model D12IR provides gas measurements using infrared sensing technology. IR sensors are available for monitoring methane and other combustible gases, carbon dioxide, or nitrous oxide. Explosion-proof design allows use in virtually all environments, with local indication and optional integral alarm relays.

WATER QUALITY MONITORS Water quality instruments are available for monitoring chemical components in drinking water, process water, and wastewater to bring better control to the treatment process. Instruments based on polarographic membrane sensors, potentiometric sensors, and laser optical sensors are designed for demanding applications requiring 24 hour a day reliability. Simplicity of operation, ease of maintenance, and low operating cost are key features of every ATI monitor. Dissolved Oxygen Dissolved Sulfide Chlorine Dioxide ph/orp Transmitter Residual Chlorine Dissolved Ozone Auto Clean ph/orp Peracetic Acid Residual Sulfite Conductivity Dissolved Ammonia Turbidity Fluoride Monitor Hydrogen Peroxide

WATER QUALITY MONITORS Dissolved Oxygen The Auto-Clean D.O. System is the answer to low maintenance D.O. monitoring. The system provides not only accurate measurement but also a unique high pressure air blast system that automatically cleans the sensor as often as needed, virtually eliminating manual sensor cleaning. Dissolved Sulfide Model Q46S/81 Dissolved Sulfide Monitors continuously measure sulfides in water and wastewater streams. Sulfides in solution are stripped into a gas stream and measured using an H 2 S gas sensor, providing extremely high sensitivity. Applications include well water monitoring, wastewater influent measurements, and metal treatment systems using hydrosulfide as a reactant. Chlorine Dioxide Model Q46H/65 Chlorine Dioxide Monitors provide a highly sensitive and selective method for monitoring residual ClO2 concentrations in potable water or cooling water systems. A direct measuring polarographic sensor allows measurement between 10 PPB and 20 PPM with minimal maintenance.

For the Water We Drink ph/orp Transmitter Q-Series ph and ORP Transmitters provide process measurements in a rugged industrial package with both 2-wire and AC powered models available. Differential type sensors manufactured from chemical resistant molded PEEK outlast conventional sensors, providing the most economical monitoring system you can buy. Residual Chlorine A variety of monitors are available for chlorine measurement in water. Reagentless systems are available for Free Chlorine, Combined Chlorine, and Total Chlorine. A special Gas Phase Total Chlorine system provides reliable measurement in extremely difficult applications. For high range applications, a system is available for measurements up to 0-2000 PPM. Dissolved Ozone Series Q46H/64 Dissolved Ozone Monitors offer direct sensing of D.O 3 concentrations for high purity water systems, bottled water facilities, and ozone treated potable water. Monitors provide interference free measurement down to 5 PPB with minimal maintenance and simple installation.

WATER QUALITY MONITORS Auto Clean ph/orp Model Q46 Auto Clean Monitors combine conventional ph or ORP sensing with a unique sensor cleaning system that greatly reduces manual maintenance. A high pressure air blast cleaning system automatically cleans the sensor as often as necessary to ensure reliable measurements. Peracetic Acid Model Q46H/85 Peracetic Acid Monitor (PAA) provides continuous real time measurement of PAA to very low levels and is suitable for chemical feed control. The direct sensing polargraphic probe is selective for PAA and is not affected by changes in H 2 O 2 in solution. Residual Sulfite Model Q46S/66 Residual Sulfite Monitors continuously measure SO 3 = concentration to insure complete dechlorination of water streams. Protection of RO membranes and compliance with zero residual chlorine discharge requirements are major applications.

For the Water We Drink Conductivity Q-Series Conductivity Systems allow measurements in both ultrapure water and very high conductivity process water. A versatile 4-electrode sensor design provides measurement from 10 us to 2 S with a single sensor, with 2-electrode sensors available for high purity water. Toroidal sensors are also available where electrode fouling is a major issue. Dissolved Ammonia ATI s ammonia measurement technology provides economical, stable, and sensitive measurements of dissolved ammonia in wastewater effluents, cooling systems, or raw water intakes. A dual sensor version of the ammonia systems provides Free Ammonia, Total Ammonia, and Monochloramine in one package which is perfect for chloramination system monitoring. Turbidity Model Q46/76 Turbidity Monitor provides sensitive and stable measurements in flowing water samples from as low as 0.01 NTU to 4000 NTU. Using the standard 90-degree light scatter technique, the sensor can be mounted in a flowcell, submerged directly into an effluent channel, or inserted into a pipe tee.

WATER QUALITY MONITORS Fluoride Monitor The Q46F Fluoride Monitor provides continuous measurement of fluoride levels in drinking water. An ion-selective sensor provides measurement down to 0.05 PPM, and an automatic calibration function insures long-term measurement accuracy without operator attention. Hydrogen Peroxide Model Q46/84 Hydrogen Peroxide Monitor was developed to provide real time measurement of low levels of H 2 0 2 in solution and is suitable for chemical feed control. The membraned sensor provides long term stability without electrode fouling and is selective for peroxide without interference from most other ions in solution. Headquarters Analytical Technology, Inc. 6 Iron Bridge Drive Collegeville, PA 19426 Email: Sales@analyticaltechnology.com WEB: www.analyticaltechnology.com 1-800-959-0299 Analytical Technology, Inc. Unit 1 & 2 - Gateway Business Park Delph New Road, Delph Saddleworth OL3 5DE Email: Sales@atiuk.com WEB: www.atiuk.com