MRI Information. MRI Safe The following AMS product does not contain metallic components and therefore is considered MRI Safe.

MRI Information. MRI Safe The following AMS product does not contain metallic components and therefore is considered MRI Safe.

Examples of component location and routing are shown on the next page:

Magnetic Resonance Imaging (MRI) Safety for Boston Scientific Products. 1. WALLSTENT Iliac Endoprosthesis with Unistep Plus Delivery System

GDC Detachable Coils, GDC 360o Detachable Coils, Matrix2 Detachable Coils, and Target Detachable Coils

MR Safety Evaluation of Orthopedic Devices: Why It's Important and How to Select Test Device Configuration

MRI Conditional Devices and Patient Safety. Outline. MRI Labeling: Objects 8/3/13 1. David W. Jordan, Ph.D. Senior Medical Physicist

MRI Safety

Metallic Neurosurgical Implants: Evaluation of Magnetic Field Interactions, Heating, and Artifacts at 1.5-Tesla

Research Article Assessment of MRI Issues at 3 Tesla for a New Metallic Tissue Marker

PRODUCT NOTIFICATIONS

12 pericardial bioprostheses. 7300TFX Carpentier-Edwards bioprosthetic valved conduit

extended sewing ring Carpentier-Edwards bioprosthetic valved conduit , 21, 22

3000, 3000TFX 12 bioprostheses Carpentier-Edwards PERIMOUNT pericardial aortic and mitral

Artifacts Caused by Eddy Current in Diffusion MRI

Replacement Heart Valve Product Description (Stented Tissue) Models Reference

CSF shunts are frequently used to treat hydrocephalus. The

MRI Safety. How can we ever forget?? July Missile Effect. Have we lost sight of our MR Safety responsibility?

Contains Nonbinding Recommendations. Draft Not for Implementation

Replacement Heart Valve Product Description (Stented Tissue) Models Reference

Replacement Heart Valve Product Description (Stented Tissue) Models Reference

RePlay Hemostasis Clip

ISO/TS TECHNICAL SPECIFICATION. Assessment of the safety of magnetic resonance imaging for patients with an active implantable medical device

RePneu (Lung Volume Reduction) Coil System Instructions For Use

RapidPort EZ Access Port Kit DIRECTIONS FOR USE (DFU)

Septal repair implants: evaluation of magnetic resonance imaging safety at 3 T

LAP-BAND System Access Port II Kit

Replacement Heart Valve Product Description (Stented Tissue) Models Reference

CHAPTER 2 INTERFERENCE ISSUES OF RFID IN MRI AND CT SCAN

Testing Methods and Standards for Magnetic Resonance (MR) Safety and Compatibility of Medical Devices - Update

Magnetic Resonance Imaging at 7T in Glasgow. A unique opportunity!

Chapter 2. Magnetic Resonance Safety. Andrew Simmons and Kristina Hakansson. Abstract. 1. Legislation, Guidance and Best Practice

TiP-TV Training in Partnership Program Supplement and Test for Imaging Professionals. MR: Quench Your Thirst for MR Safety

Endovascular Device Testing A Survey of Requirements for Product Validation


Final Project

Current Issues in MRI Safety

PRINCIPLES OF CT AND MR IMAGING Marc-André d Anjou, DMV, DACVR Faculty of Veterinary Medicine, University of Montreal Saint-Hyacinthe, Quebec, Canada

Background. Magnetic Resonance Spectroscopy (MRS) non invasively measures metabolite concentrations

MRMD and MRSO Examination Content Syllabus

The Harvard community has made this article openly available. Please share how this access benefits you. Your story matters. doi:10.

SELF-REGULATORY INITIATIVE FOR MEDICAL IMAGING EQUIPMENT MAGNETIC RESONANCE MEASUREMENT OF ENERGY CONSUMPTION

The Unique, New MRI Philips Ingenia 3 Tesla is now in Ayios Therissos! The first-ever digital broadband MR system has been installed in Ayios

A Guide to the Safety, Health and Welfare at Work (Electromagne c Fields) Regula ons (S.I. No. 337 of 2016)

MRI. Magnetic Resonance Imaging

Assessment of MRI Issues for a 3-T Immune Programmable CSF Shunt Valve

Simplicity is efficiency. Analyzing Moisture Content by Using Magnetic Resonance Technology

- MRI Safety Update - RF Induced Heating. Society for Medical Innovation and Technology

Magnetic Resonance Imaging of concrete. Coring. Location of flaws. Assessment of Concrete Structures. Systems to monitor concrete modulus

Magnetic Resonance Spectroscopy from fundamental developments to improved noninvasive diagnosis and characterisation of children s brain tumours.

MRI Safety & Site Planning. Lawrance Yip Senior Radiographer, DR, QMH 16 June 2007

Overview of ASTM Subcommittee F04.15 on Material Test Methods Terry O. Woods, Ph.D. FDA Center for Devices & Radiological Health

In Vitro Investigation of Pacemaker Lead Heating Induced by Magnetic Resonance Imaging: Role of Implant Geometry

Magnetic Resonance Imaging. D. J. McMahon rev cewood

MRI Safety aspects. for the anaesthesiologist

Azur Peripheral Coil System Helical HydroCoil Embolization System (Detachable) Instructions for Use

Uncompromised accuracy in neuroimaging and treatment

CQIE MRI PROCEDURES. American College of Radiology Clinical Research Center. Centers for Quantitative Imaging Excellence LEARNING MODULE

Special thanks to the University of Utah for allowing us to adapt their materials. MRI Safety and Training

Friday, May 29, Update on Testing Medium Voltage Cable and Switchgear Systems

Guidance for Industry and FDA Staff. Criteria for Significant Risk Investigations of Magnetic Resonance Diagnostic Devices

Chapter 3. An evaluation of the suitability of endografts for an MRI-based follow-up after EVAR

Press Presse Press Presse

Pulsed NMR of Paramagnetic Terbium. Cheyenne Michael Yari

MRI Protocols in Experimental Stroke. Xenios Milidonis Centre for Clinical Brain Sciences The University of Edinburgh

ClinScan. think forward. Small Animal MRI Solution for Molecular Imaging and Translational Research. Preclinical MRI

Modified WHO Surgical safety check-lists for MRI-related safety in hybrid operating room

Simple, intuitive and accessible MRI solution for preclinical research. M-Series Compact MRI Systems

M-PHASE Magnetic resonance multiphase flowmeter for the simultaneous measurement of oil, gas and water

TA10 Non Ionizing Radiations EVALUATION OF EMF EXPOSURE FROM MEDICAL ELECTRICAL EQUIPMENT. Halina Aniołczyk, Paweł Mamrot, Piotr Politański

Simple, intuitive and accessible MRI solution for preclinical research. M-Series Compact MRI Systems

Vibration effects in healthcare facilities

Arrhythmia Summit Basel

Electromagnetism. Magnetism & Electricity

3. Introducing Narda Workers Directive preliminary approach

Balancing versatility and value Introducing Optima MR T

MR Safety and Compatibility Issues at High Magnetic Fields

Innovations in medical imaging:

2018 REVIEW CATEGORIES

Measuring Residual Magnetism of Ferromagnetic Parts

ASQ-10. Ten Meter Squalo INSTRUCTION MANUAL. CAUTION: Read All Instructions Before Operating Equipment. Cushcraft. Amateur Radio Antennas

DuoFLEX. MRI Coil Suite. Flexible coils that contour to your patient and your budget.

Mark van der Zande April 2 nd 2015 Sense of Contact 17. Magnetic Resonance Technology A new concept for Multiphase Flow Measurement

Approval of subjects for measurements at ultra-high-field MRI

Choose both quality and value

Magnetic Resonance Safety Update 2002: Implants and Devices

Emerging Applications and Trends Across Medical Imaging

NeuroPort Array PN 4382, 4383, 6248, and 6249 Instructions for Use

Medical Devices Having MRI Compatible Metal Alloys

SMP Coaxial Connectors Update

MR Compatibility of Mechatronic Devices: Design Criteria

MR Basics: Module 7 Safety Essentials

An ultrasonic volumetric scanner for image-guided surgery

Date: May 26, 2015 Page 1

Computer Assisted Surgery Basics of medical imaging

Important Information

Guidance Document Magnetic Resonance Imaging Effective Review Delegated & Full Board Version Date February 1, A. Preamble

SMB Flexible Cable Connector Index

Leksell. Vantage Stereotactic System. Advancing stereotactic neurosurgery

Operation and Maintenance Manual

Transcription:

To Whom It May Concern: DeRoyal Foley Catheters with Temperature Sensors have been tested for safe use in magnetic resonance environments at 1.5 and 3.0 Tesla according to ASTM International F2052, Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment. The testing at 1.5 Tesla and 3.0 Tesla was completed in 2014 and 2010 respectively. The results demonstrate that the catheters are MR Conditional, according to ASTM International F2503, Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment. This designation means the device has demonstrated safety in an MR environment with defined conditions. These conditions are defined in the attached pages. Please consult the Instructions for Use and the attached guidelines prior to using the device.

Additional instructions for use in MR environments based on testing performed in 2004 according to ASTM F2052-02, Standard Test Method for Measurement of Magnetically Induced Displacement force on Passive Implants in the Magnetic Resonance Environment MR system: 1.5 Tesla Important Note: To safely perform magnetic resonance imaging (MRI) in a patient, it is important to closely follow highly specific conditions and guidelines that have been determined to permit the examination to be conducted safely. Any deviation from these conditions and guidelines may result in a serious injury to the patient or damage to this device. Important Note: Magnetic Resonance Imaging (MRI) safety testing conducted on the Foley Catheters with Temperature Sensors was based on the fact that these devices are not intended for use to monitor temperature during MRI or in the MRI environment. Furthermore, these devices should not be connected to a cable or otherwise attached to a temperature recording device in the MRI environment. Failure to follow these instructions may result in serious injury to the patient or damage to the device. Magnetic resonance imaging (MRI) procedures must be performed according to the following conditions and guidelines: Static Magnetic Field Testing of magnetic field interactions (translational attraction and torque) in association with a shielded 1.5-Tesla MR system demonstrated that this device does not exhibit substantial translational attraction (maximum spatial gradient for the 1.5-Tesla MR system used to assess translational attraction, 2.4 Tesla/meter) or torque. (The evaluation of translational attraction was conducted according to ASTM F-2052, Standard Test Method for Measurement of Magnetically Induced Displacement Force on Passive Implants in the Magnetic Resonance Environment.) Therefore, in consideration of the intended in vivo use of this device, there is no additional risk to a patient with this device with respect to movement or dislodgment using a 1.5-Tesla MR system. Accordingly, a patient with this device may safely undergo an MRI procedure using an MR system operating at a static magnetic field of 1.5-Tesla or lower, with special attention to closely following additional conditions and guidelines (see below). Gradient Magnetic Fields An MRI procedure conducted on a patient with this device may use conventional pulse sequences including spin echo, fast spin echo, gradient echo, and fast gradient echo pulse sequences at 1.5-Tesla or lower. Unconventional or non-standard MRI techniques have not been assessed for this device and, therefore, must be avoided. In general, pulse sequences such as echo planar, magnetization transfer contrast, and other techniques or procedures that exceed gradient magnetic fields of 20-Tesla/sec. must not be used for an MRI procedure in a patient with this device. Radiofrequency (RF) Fields: MRI-related heating was assessed for this device according to F 2182 02 Standard Test Method for Measurement of Radio Frequency Induced Heating Near Passive Implants During Magnetic Resonance Imaging. Based on this information, MRI

procedures must not exceed exposures to radiofrequency (RF) fields greater than a whole-bodyaveraged specific absorption rate (SAR) of 1.5 W/kg for 20- minutes in a patient with this device. Important Note: MRI-related heating was tested for only one configuration of the Foley Catheter with Temperature Sensor: straight configuration without coils or loops for the catheter and the temperature connector component. The Foley catheter and temperature connector component were directed down the center of the MR system bore, without touching an RF coil or other similar device. Therefore, to ensure patient safety and to prevent excessive heating during an MRI procedure, this device should be placed in a straight configuration, directed down the center of the MR system, without touching an RF coil or other similar device. MRI- related heating for other configurations or positions of this device are unknown. MRI Settings and Device Positioning Disconnect the device from cable or other temperature recording device before entering the MRI environment. Direct the device in a straight configuration down the center of the MR system, without touching an RF coil or similar device. Do not use MR systems operating at static magnetic field strengths higher than 1.5-Tesla. Select MRI parameters so that they do not exceed a whole body averaged specific absorption rate (SAR) of 1.5 W/kg to minimize the risk of heating. Instruct the patient to immediately alert the MR system operator of any problems (heating, shocks, etc.) so the operator can immediately terminate the MRI procedure, if needed. Provide the patient with a means to alert the MR system operator of problems (e.g., heating, shocks, etc) so the operator can immediately terminate the MRI procedure, as needed. Monitor the patient continuously during the MRI examination and be prepared to respond in the event of an emergency. Definitions: MR-safe defined by ASTM F2052-02: The device, when used in the MR-environment, has been demonstrated to present no additional risk to the patient or other individuals, but may affect the quality of the diagnostic information. Importantly, the specific conditions used for assessment of MR safety must be specified.

Additional instructions for use in MR environments based on testing performed in 2010 according to ASTM F2052-06e1, Standard Test Method for Measurement of Magnetically Induced Displacement force on Passive Implants in the Magnetic Resonance Environment MRI Information MR system: 3-Tesla MR Conditional The DeRoyal Foley Catheter with Temperature Sensor was determined to be MR-conditional according to the terminology specified in the American Society for Testing and Materials (ASTM) International, Designation: F2503-08, Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment. Non-clinical testing demonstrated that the DeRoyal Foley Catheter with Temperature Sensor is MR Conditional. A patient with this device can be scanned safely immediately after placement under the following conditions: Static Magnetic Field -Static magnetic field of 3-Tesla or less -Maximum spatial gradient magnetic field of 720-Gauss/cm or less MRI-Related Heating In non-clinical testing, the DeRoyal Foley Catheter With Temperature Sensor produced the following temperature rise during MRI performed for 15-min of scanning (i.e., per pulse sequence) in the 3-Tesla (3-Tesla/128-MHz, Excite, HDx, Software 14X.M5, General Electric Healthcare, Milwaukee, WI) MR system: Highest temperature change +4.2 C Therefore, the MRI-related heating experiments for the DeRoyal Foley Catheter with Temperature Sensor, 18-Fr at 3-Tesla using a transmit/receive RF body coil at an MR system reported whole body averaged SAR of 2.9 -W/kg (i.e., associated with a calorimetry measured whole body averaged value of 2.7-W/kg) indicated that the greatest amount of heating that occurred in association with these specific conditions was equal to or less than +4.2 C. Artifact Information MR image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of the DeRoyal Foley Catheter With Temperature Sensor, 18-Fr, REF 81-080718. Therefore, optimization of MR imaging parameters to compensate for the presence of this device may be necessary. Pulse Sequence T1-SE T1-SE GRE GRE Signal Void Size 1,956-mm 2 159-mm 2 3,262-mm 2 763-mm 2 Plane Orientation Parallel Perpendicular Parallel Perpendicular Important Note: This labeling information pertains to MRI conditions at 3-Tesla ONLY (no other MR system field strength/frequency, higher or lower).

Additional MRI Information: Importantly, the MRI procedure should be performed using an MR system operating at a static magnetic field strength of 3-Tesla, ONLY. The safe use of an MR system operating at lower or higher field strength for a patient with a DeRoyal Foley Catheter with Temperature Sensor has not been determined. Special Instructions: The position of the wire and connector of the DeRoyal Foley Catheter with Temperature Sensor has an important effect on the amount of heating that may develop during an MRI procedure. Accordingly, the DeRoyal Foley Catheter with Temperature Sensor must be positioned in a straight configuration down the center of the patient table (i.e., down the center of the MR system without any loop) to prevent possible excessive heating associated with an MRI procedure. The wire and connector must not touch the patient. Additional instructions include the following: (1) The DeRoyal Foley Catheter with Temperature Sensor should not be connected to the temperature monitoring equipment during the MRI procedure. (2) If the DeRoyal Foley Catheter with Temperature Sensor has a removable catheter connector cable, it should be disconnected prior to the MRI procedure. (3) Remove all electrically conductive material from the bore of the MR system that is not required for the procedure (i.e., unused surface coils, cables, etc.). (4) Keep electrically conductive material that must remain in the bore of the MR system from directly contacting the patient by placing thermal and/or electrical insulation (including air) between the conductive material and the patient. (5) Position the Foley catheter with a temperature sensor in a straight configuration down the center of the patient table to prevent cross points and conductive coils or loops. (6) The wire and connector of the DeRoyal Foley Catheter with Temperature Sensor should not be in contact with the patient during the MRI procedure. Position the device, accordingly. (7) MR imaging should be performed using an MR system with static magnetic strength of 3- Tesla, ONLY. (8) At 3-Tesla, the MR system reported whole body averaged SAR should not exceed 2.9-W/kg for 15-min of scanning (per pulse sequence).