The Application of Non-phosphorous AEC Program in Cooling Water Systems of Petrochemical Industry

Similar documents
Sulfuric Acid Plant Cooling Tower Improvements

high cycles cooling tower operation using a revolutionary alkaline treatment program Continuum* AEC (Alkyl Epoxy Carboxylate)

NACE CORROSION 2008 TEG 096X Symposia - Paper 1421

ABSTRACT. Key words: high silica, silica polymerization, scale formation, water scarcity, water reuse INTRODUCTION

COMPREHENSIVE REPORT PRE CLEANING & PASSIVATION PROGRAMME OF ENTIRE RECIRCULATING COOLING WATER SYSTEM OF ECO PLANT BILAG INDUSTRIES LTD.

IWC ZLD: New Silica Based Inhibitor Chemistry Permits Cost Effective Water Conservation for HVAC and Industrial Cooling Towers

Zero Liquid Discharge Cooling Tower Treatment at CSI

Real World Experiences with a Plant- Based Alternative to Chemical Treatment in Cooling Water Systems

1. Introduction. Figure 1: Open Recirculation Cooling Water Tower (image courtesy of Solenis) Page 3

NACE Paper No

Cooling Tower Treatment Chemicals

13 th Annual GC&EC Green Corrosion Inhibition and Water Treatment Session

COOLING TECHNOLOGY INSTITUTE

ACUMER 2200 High Performance Scale Inhibitor

Wastewater Characterization. Tenaska Westmoreland Generating Station

Benefits of Novel Cooling Water Chemistry on Refinery Economics

Modern Treatment Programmes Can Reduce Water Consumption in Cooling Towers

Evaporative Condenser Passivation. Cameron Klein Strand Associates, Inc.

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

an integrated approach to water reuse

Acidity and Alkalinity:

OPERATIONAL UPDATE ON INNOVATIVE COOLING TOWER PRETREATMENT TECHNOLOGY

Case Study 3M Corporate Headquarters 2014 Distributed by:

Distribution Review. Corrosion Control. Corrosion Control Vocabulary. American Water College 1. Corrosion Control Training Objectives

PRODUCT PROGRAMMING GUIDELINES CHEMICAL GUIDELINES

Zero Blowdown Technology - ZBT Arizona Transportation Center

KKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana

Carbosperse K-700 Water Treatment Polymers

DOW Ultrafiltration. Case History. DOW Ultrafiltration Membranes Offer Reliable, Economical Answer to High Solids

Saturation Index -100 F

2.2.3 Water Quality of Groundwater and Surface Water

Water Recycle as a Sustainability Tool for Industrial Plants

Green Corrosion Inhibition and. (NGC) for Cooling Water Treatment. Report by Dan Duke Water Conservation Technology International

Zero Discharge Treatment Method for Cooling Towers and Heat Exchangers with SP3, I-SOFT-OB, OXYDES & KATALOX LIGHT

ACUMER 3100 Terpolymer The Anti-Scale Deposition for Stressed Cooling Water Conditions

Treatment Technologies

Schematic diagram of a cooling water system

OPTIDOSE 4210 Traceable Polymeric Acid Scale Inhibitor and Dispersant

Waterside Cleaning of Recovery Boilers.. Pay Now or Pay Later

Stressed Cooling Water System Deposit Control Management

Corrosion Control Across Consecutive Systems

REQUEST FOR PROPOSALS DESAL ANTISCALANT/CLEAN-IN-PLACE CHEMICALS BID NO: ADDENDUM 1

Carbosperse K-700 Water Treatment Polymers

Solus* AP - advanced boiler all-polymer internal treatment technology

NPDES COMPLIANCE OF COOLING TOWERS BLOWDOWN AT POWER PLANTS WITH RECLAIMED WATER AS SOURCE WATER

DOW Ultrafiltration. Case History. DOW Ultrafiltration Modules Protect Reverse Osmosis System from High Iron

Dispersants & antiscalants

Optimizing Steam and Cooling Systems for Reliability and Sustainability. Presented By: Kevin Emery

Higher COC and ph Independent Operation of Cooling Water Systems

The OWASA UNC Reclaimed Water System: A Progress Review

Water Conservation Technology for Recirculating Cooling Systems

LOCALIZED AND GENERAL CORROSION OF COPPER IN AZOLES AND SILICA INHIBITED ZERO BLOWDOWN COOLING WATER IN AN AUTOMOTIVE PLANT

RECYCLED WATER AT SYDNEY OLYMPIC PARK. Andrzej Listowski SYDNEY OLYMPIC PARK AUTHORITY

Technical Data Monograph. Stainless Steel Instrument Maintenance Using Prolystica Restore Descaler & Neutralizing Detergent

Forward Osmosis Applied to Desalination and Evaporative Cooling Make-up Water

COOLING TOWER WATER TREATMENT

New Challenges, Solutions, and Opportunities in Leachate Collection Systems. Matthew Poore, Progressive Environmental Services

Water Monitoring - Teralba Quarry EPA Point No.4 - Adit Overflow

Environmental Sustainability through the use of Nalco 3D TRASAR Technology for Sea Water Cooling tower

Prevention Strategies Design and Coatings

Joel E. Bowdan III, P.E WateReuse California CII Pre-Conference Workshop

Studies on performance of indices in cooling water system

Lead and Copper Rule and Treatment Overview

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)

Application Data Sheets ISSUE DATE 17/04/ :09:40

Cooling Water Treatment

Golden Sunlight Mine Bio-Treatment of Acid Producing Waste. By Rory Tibbals Operations Superintendent

Boiler/Cooling Water Processes and Parameters

Water Resources Director: Chris Graybeal

ACUMER ACUMER 4450 ACUMER 4800

Water Treatment Solutions A - Z

Dan Duke Water Conservation Technology International, Inc. Temecula, CA. Lietai Yang Corr Instruments, LLC San Antonio, TX ABSTRACT

Compliance Through Stability The Art of Avoiding Plant Crises. Timothy J. Drake, Zinkan Enterprises, Inc. Andrew Rupprecht, Premier Magnesia

DESIGN AND OPERATION OF A HYBRID RO SYSTEM USING ENERGY SAVING MEMBRANES AND ENERGY RECOVERY TO TREAT SOUTHERN CALIFORNIA GROUND WATER.

Boiler Water Chemistry: Getting From the Source to the Boiler Colleen M. Layman, PE

EFFECTIVE USE OF RECYCLED WATER IN COOLING TOWERS WITH NEW GREEN TECHNOLOGY. Abstract

Joe Walters West Basin Municipal Water District, Carson CA. Dan Duke Water Conservation Technology International, Temecula, CA

Monthly Environmental Data January 2014

Wastewater reuse for industrial applications in cooling towers

Water QUALITY OF THANLWIN AND ATTARAN RIVERS

Membrane Technology: From Manufacture to. May Production

Common Well Problems. Common Well Problems. Well Forensics. Difficult Well Problems May Require Well Forensics 12/11/2017

AL 29-4C AL 29-4C. Technical Data Sheet. Stainless Steel: Superferritic INTRODUCTION (UNS S44735)

M. Ghazi Mirsaeed 1, A.Ataei 1, A. Torabian 2, A.H. Hassani 1, J.Hashmiyan 3

DIFFERENTIATION OF WATER SOURCES USING ANALYTICAL WATER CHEMISTRY DATA

QUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater;

Making feed water for you! Advantage. Protecting any Water Treatment System against. Scaling. a Water Company WAT C H WAT E R

Cooling Water Treatment

SOIL TEST KIT INDIVIDUAL TEST KITS MULTI PARAMETER TEST KITS SWIMMING POOL TEST KIT

Reuse of water and still maintaining reliability by avoiding scale, biological slime and corrosion effects even more effectively.

OPTIDOSE 1000 Traceable Polymer A Tool for Maintaining Maximum Heat Transfer

Lead & Copper Control with Phosphates Darin Skutt Technical Service Manager Carus Corporation

3. Add 0.4 ml of. 7. Use a TenSette

CO forms CO 2. forms. (a) The coke reacts with the oxygen in the air to form carbon dioxide. C + O 2

Boiler Water Treatment

One of the main ores of zinc is zinc blende, ZnS. There are two stages in the extraction of zinc from this ore.

Removing Heavy Metals from Wastewater

Pilot scale evaluation of mine water (MW) as a cooling medium

Water and Energy in Arizona

Biodegradation Test of Chemical Substances

Transcription:

CORROSION SCIENCE AND TECHNOLOGY, Vol.7, No.1(2008), pp.16~21 The Application of Non-phosphorous AEC Program in Cooling Water Systems of Petrochemical Industry Li Dagang, Mike Hong, and He Gaorong Suite 4208, United Plaza 1468 Nanjing Road West, Shanghai 200040, China GE Water & Process Technologies A non-phosphorous program employing an alkyl epoxy carboxylate (AEC) has been successfully applied to petrochemical and other large industrial open recirculating cooling water systems. AEC is a patented non-phosphorous calcium carbonate scale inhibitor that has demonstrated better scale inhibition abilities than traditional organic phosphonates. In addition to its antiscalant properties, AEC inhibits carbon steel corrosion when used at high dosages. AEC can be combined with zinc to form a non-phosphorous program with very low levels of phosphate to provide an environmentally acceptable program. In actual applications, the total phosphate developed in the cooling system from cycling the makeup is below 1 ppm as PO 4. This level has complied with the highest standards of wastewater discharge limitations. The performance of two AEC/Zinc applications is reviewed. In both cases excellent corrosion and scale control were achieved with AEC/Zinc programs. One case history details the performance with a low hardness water (100 ppm calcium, as CaCO 3) operating at 8-10 cycles of concentration. The corrosive nature of the water and the long retention time of the system stressed both the corrosion and scale control capabilities of the program. The second case history demonstrates the performance of the program with a moderate hardness water (400-600 ppm calcium, as CaCO 3), but under harsh conditions of high temperature and low flow. The AEC/zinc combination has been found to be highly effective in controlling the corrosion of ferrous metals. AEC can provide good corrosion inhibition at high concentrations, while zinc is known to be an excellent cathodic inhibitor. The combination of the two inhibitors not only provides a synergistic blend that is effective over a wide range of operating conditions, but also is environmentally friendly. Keywords : alkyl epoxy carboxylate, non-phosphorous, cooling water, corrosion inhibitor 1. Introduction The development of cooling water treatment technologies, since the introduction of phosphonates in the late 1960 s has become increasingly more driven by environmental considerations. Phosphonate-based programs are still the most prevalent cooling water treatment programs now From the report 1). Phosphonates serve the dual function of calcium carbonate scale control and steel corrosion protection. Although the commonly used phosphonates as calcium carbonate scale inhibitor can contribute to steel corrosion protection when used with inorganic phosphate and/or zinc, alone they are weak corrosion inhibitors. Recently, environmental concerns have been raised Corresponding author: Dagang.Li@ge.com about the discharge of phosphorous containing compounds in the effluent streams resulting in eutrophication of receiving waters. As a result, the use of phosphorous-based water treatment chemicals is being viewed as less environmental acceptable. Reductions in total phosphorus contributed by phosphonate-based programs could be achieved by using non-phosphorus scale inhibitors in combination with low dosage of phosphate and/or zinc. However, this would require that the scale inhibitor have the same or superior scale control capabilities as phosphonate materials and contribute to steel corrosion protection in a comparable manner. The replacement of phosphonate-based programs by non-phosphorous or low-phosphorous containing corrosion inhibitors would require the use of more effective polymeric scale inhibitors to control both corrosion and scale deposition From the report 1). 16

THE APPLICATION OF NON-PHOSPHOROUS AEC PROGRAM IN COOLING WATER SYSTEMS OF PETROCHEMICAL INDUSTRY A non-phosphorus, nitrogen free scale inhibitor has been developed that provides calcium carbonate control superior to phosphonate inhibitors and enhances steel corrosion protection. The new material, an Alkyl Epoxy Carboxylate (AEC), is the most significant advance in calcium carbonate inhibitors in the past 30+ years, and is the only effective non-phosphorus calcium carbonate inhibitor for highly saturated waters. In combination with orthophosphate and/or zinc, AEC enhances the corrosion inhibition of cooling water treatment programs. Improved or equivalent corrosion control can be achieved with lower concentrations of orthophosphate or zinc compared to conventional alkaline ph programs From the reports 2),3),4). AEC is not susceptible to hydrolysis or breakdown by normal concentrations of chlorine used in microbiological control programs. Therefore, unlike some conventional phosphonates, no loss of scale control or corrosion inhibition is experienced during periods of chlorination of cooling systems. AEC also has a high calcium tolerance and therefore, compared to certain phosphonates, doesn t form insoluble calcium salts within the system From the report 2). Low-phosphorous AEC programs have been successfully applied in many open recirculating cooling systems From the reports 2),3),5),6). 2. Evolvement of Non-phosphorous program Over the past decade years, the changes in water treatment technologies have been extremely rapid in every industrial sector, driven by the new or proposed government regulations. The scope of changes is best exemplified by some of the major trends driving the cooling water treatment technology today, including minimizing waste discharge, reducing water consumption and minimizing or eliminating the use of phosphorous containing compounds. With the increased consciousness of environmental protection, many countries have already restricted the discharge of phosphorous. Low-phosphorous and non-phosphorous water treatment programs have become desirable. For petrochemical industry, the open recirculating cooling water system is the largest water user in the plant. The discharge standard for petrochemical industry is regulated under Integrated wastewater standard (GB 8978-1996) in China, and most waste water effluents are required to meet the discharge standard listed in table 1 From the report 7). For low phosphate programs, AEC is used primarily for scale control and inorganic phosphates used for steel corrosion protection. Substituting AEC for phosphonate inhibitors lowers the overall phosphorus level without sacrificing corrosion protection. Although these formulas have good performance, they lose the green advantage of AEC. There is a demand, for a more environmentally acceptable corrosion inhibitor package for ferrous-based metals in contact with aqueous systems. In particular, there is a demand for a non-phosphorous contained treatment program. In addition to its good deposit control properties, AEC has good corrosion inhibition for carbon steel when applied at concentrations higher than those needed for scale control. It is not only a kind of green scale inhibitor, but also a green corrosion inhibitor From the reports 8),9). The corrosion inhibition properties of AEC, unlike conventional phosphonates, are characterized by a strong anodic inhibition with moderate cathodic inhibition component From the report 1). The existence of oxygen atom in AEC molecular structure makes it easy to form stable chelated pentacyclic structures From the report 8). Zinc is an extremely powerful cathodic corrosion inhibitor for steel. In many respects, zinc-based programs offers some performance advantages over inorganic phosphate treatments. This is especially noticeable when the effluent goes to waste treatment plants. In contrast to phosphate which may be difficult to remove, most treatment plants can readily remove zinc to very low concentrations with no additional treatment step. In low hardness con- Table 1. National integrated wastewater discharge standard Item Applicable Range First Grade Standard Second Grade Standard Third Grade Standard ph All Discharge Unit 6~9 6~9 6~9 Phosphorus [mg/l as P] All Discharge Unit 0.5 1.0 - Total Zinc [mg/l] All Discharge Unit 2.0 5.0 5.0 Note: 1. The wastewater drained to the Ⅲ type water areas in GB3838 (Except for state protected and swimming areas) and to the second type sea areas in GB3097, should meet the first grade standard. 2. The water drained to the Ⅳ and Ⅴ type water areas in GB3838 and to the third type sea areas in GB3097 should meet the second grade standard. 3. The wastewater drained to the municipal drainage systems including two stage wastewater treatment factory, should meet the third grade standard. CORROSION SCIENCE AND TECHNOLOGY Vol.7, No.1, 2008 17

LI DAGANG, MIKE HONG, AND HE GAORONG ditions, zinc containing cooling water programs are generally acknowledged as being the preferred treatment, since they do not depend on calcium hardness (calcium phosphate) to provide cathodic inhibition. Combinations of AEC and zinc have been shown to be synergistic in their ability to inhibit steel corrosion From the reports 3),9). Programs based on AEC and zinc have a long history in industrial cooling water applications and are the mainstay of non-phosphorus programs provided by GE Water & Process Technologies. In order to eliminate the impact of phosphorous on wastewater and meet the first grade discharge standard, a non-phosphorous, AEC-based program was proposed for petrochemical and other large industrial open recirculating cooling water systems. 3. Laboratory evaluations 3.1 Test methods and conditions The corrosion inhibition test for non-phosphorous AEC programs was evaluated using the Beaker Corrosion Test Apparatus (BCTA). The BCTA consists of a 2 liter beaker equipped with air sparge, two A3 low carbon steel coupons(size: 50 25 2 mm, area: 28 cm 2 ) and a magnetic stir bar. The test solution was 2 liters. Air sparging was done continuously during the test. The magnetic stirrer can control the solution temperature. All tests were conducted at 40, stirred at 300 RPM. The test duration was 24 hours. In all tests the coupons immersed in the beaker during the test were photographed. The corrosion rate was measured by the coupon weight loss. Please see the test photo in Fig. 1. Fig. 1. BCTA photo Table 2. low hardness water condition Items Unit Data ph 8.7 Total Hardness mg/l as CaCO 3 50 Calcium Hardness mg/l as CaCO 3 40 Magnesium Hardness mg/l as CaCO 3 10 Conductivity µs/cm 332 Total Dissolved Solids mg/l 217 Chloride mg/l 28 Sulfate mg/l 22 Silica mg/l as SiO 2 26 Table 3. Corrosion rate of test 1 Chemicals Name Dosage [mg/l] AEC3174 70 AZ8104 10 AEC3174 70 AZ8104 10 MS6207 10 AEC3174 110 AZ8104 10 Coupon Corrosion Rate [mpy] (mm/y) 1.82 (0.046) 1.27 (0.032) 0.48 (0.012) 3.2 Test 1- Low hardness water The water used for testing is prepared by chemical addition to the deionized water. The test water condition is in table 2. The relatively low calcium hardness makes it difficult for inhibitors which depend on calcium to function effectively. The relatively low chloride and sulfate levels make the water with low pitting corrosion tendency. The BCTA test results are shown in table 3. AEC3174 is the mixture of AEC, sulfonated polymeric dispersant and zinc. AZ8104 incorporates a halogen resistant azole (HRA) for copper corrosion protection. MS6207 contains zinc. From table 3, we know non phosphorus AEC program can well control the corrosion of carbon steel in low hardness water. 3.3 Test 2- Moderate hardness and high chloride water The water used for testing is prepared by chemical addition to deionized water. The test 2 water condition is in table 4. The water with moderate calcium hardness and alkaline ph made the water with LSI about 1.7 at 40. The relatively high chloride and sulfate levels (for the given calcium level) make the water aggressive to ferrous metals, particularly with respect to pitting corrosion. 18 CORROSION SCIENCE AND TECHNOLOGY Vol.7, No.1, 2008

THE APPLICATION OF NON-PHOSPHOROUS AEC PROGRAM IN COOLING WATER SYSTEMS OF PETROCHEMICAL INDUSTRY Table 4. Moderate hardness water condition Items Unit Data ph 8.5 Total Hardness mg/l as CaCO 3 750 Calcium Hardness mg/l as CaCO 3 500 Magnesium Hardness mg/l as CaCO 3 250 Total Alkalinity mg/l as CaCO 3 150 Conductivity µs/cm 2650 Total Dissolved Solids mg/l 1930 Chloride mg/l 500 Sulfate mg/l 500 Silica mg/l as SiO 2 15 Table 5. Corrosion rate of test 2 Chemicals Name Dosage [mg/l] AEC3175 70 MS6207 13 PY5200 15 AEC3175 100 MS6207 10 AEC3175 100 MS6207 20 PY5200 10 AEC3175 120 MS6207 10 AEC3175 120 MS6207 20 Coupon Corrosion Rate [mpy] (mm/y) 4.4 (0.112) 3.5 (0.089) 0.71 (0.018) 2.9 (0.074) 0.63 (0.016) The BCTA test results are shown in table 5. AEC3175 is a mixture of AEC, a sulfonated copolymer and HRA. PY5200 is a single component product containing a sulfonated copolymer. From table 5, we know non-phosphorus AEC program can well control the corrosion of carbon steel in moderate hardness and high chloride water. Increasing the concentration of AEC or zinc can both enhance the corrosion inhibiting ability for carbon steel. AEC and zinc demonstrate a synergistic effect in corrosion inhibition. 3.4 Test summary From the above test results, AEC/Zinc program without phosphorus can well control the corrosion of ferrous metal in cooling water systems. AEC/Zinc program are effective in the presence of high chloride and is applicable to both high and low hardness waters. Eliminating inorganic phosphate for corrosion protection provides an environmentally friendly program and eliminates the associated wastewater discharge concerns. Table 6. Cooling system make up and tower water data Items Unit Make up Cooling tower ph 7.0 8.8 Total Hardness mg/l as CaCO 3 15 168 Calcium Hardness mg/l as CaCO 3 10 112 Magnesium Hardness mg/l as CaCO 3 5 56 Total Alkalinity mg/l as CaCO 3 15 180 Conductivity µs/cm 60 925 Turbidity NTU 2 6 Chloride mg/l 9 144 Sulfate mg/l 8 82 Silica mg/l as SiO 2 9.6 92 Phosphate mg/l PO 4 <0.05 0.45 Iron mg/l 0.1 0.37 Zinc mg/l 0.25 4. Field performance 4.1 Case history-1 4.1.1 Background A new large Ethylene plant in southern China has four open recirculating cooling systems. Makeup water is clarified river water, which has very low calcium, alkalinity and conductivity (See Table 6). In order to eliminate the impact of phosphorus on the seawater, the cooling water program is strictly limited to <1 mg/l of total phosphate and <1 mg/l of zinc. 4.1.2 Treatment program AEC/Zinc non-phosphorus program has been applied in this plant. The program provides both corrosion and deposition control by utilizing: AEC to control calcium carbonate scaling and inhibit steel corrosion, a sulfonated copolymer (HPS-1) to prevent zinc precipitation and disperse particulate solids (clays, silt, iron oxides, etc.), zinc to inhibit steel corrosion and HRA to prevent copper alloy corrosion. Sodium hypochlorite solution is used as the oxidizing biocide, supplemented with a bio-dispersant and a non-oxidizing biocide for microbial control. 4.1.3 Treatment results After the precleaning and prefilming operation, the cooling water systems underwent about 3 to 5 months transitional period with little heat load. During this time, the cooling water calcium hardness was below 40 mg/l for an extended period. Caustic soda was added to increase the cooling water ph to 8.4~8.7. Coupon corrosion test showed excellence performance. Corrosion rates were below 0.4 mpy (0.01 mm/y) for carbon steel and below 0.2 mpy (0.005 mm/y) for admiralty brass during the transitional stage. CORROSION SCIENCE AND TECHNOLOGY Vol.7, No.1, 2008 19

LI DAGANG, MIKE HONG, AND HE GAORONG Corrosion rate [mpy] 0. 4 0. 35 0. 3 0. 25 0. 2 0. 15 0. 1 0. 05 0 Dec-05 Feb. -06 Mar -06 Apr -06 May -06 J ul -06 Sep-06 Oct -06 Dec-06 Jan-07 Da t e Fig. 2. Carbon steel coupon corrosion rate in CT1&2 During the normal operation with heat load, the cooling water chemical dosages and treatment cost were optimized based on excellent performance. Cooling tower cycles were controlled at 8 to 10 based on the silica calculation. The average cooling water data in 2006 are in Table 6. As can be seen, the cooling water total phosphate and zinc are both below 1 ppm, which meets the demand of the first grade wastewater discharge standard. The lower calcium hardness makes it very corrosive for ferrous metal. Meanwhile, high cycles systems with long retention time stressed both scale and corrosion control. The low iron level of the cooling water indicated that the system was being protected. For more than 12 months normal operation, coupon corrosion results demonstrated excellence performance. (Please see the carbon steel coupon corrosion rate tendency for cooling tower 1&2 in Fig. 2.) Corrosion rate were consistently below 0.5 mpy (0.013 mm/y) for carbon steel and below 0.2 mpy (0.005 mm/y) for admiralty brass. The equipment inspections also showed excellent scale, corrosion and biological control. 4.2 Case history-2 4.2.1 Background In a new large Ethylene plant in eastern China, the makeup water for open recirculating cooling systems is clarified river water, which has moderate calcium, alkalinity and high chloride (See the average make up water in 2006 in Table 7). In order to eliminate the impact of wastewater on nearby coastal area, total phosphate and zinc were required to be less than 1.5 and 2 ppm respectively in the cooling water blowdown. There are many high temperature, low water velocity heat exchangers in this cooling water system. Meanwhile, the large system volume resulted in a long retention time, which increased the treatment difficulty under harsh conditions. 4.2.2 Treatment results The treatment program is the same as the previous case history. Cycles of concentration were limited to 4 to maintain a site imposed chloride limitation less than 500 ppm. Cooling water has moderate calcium and high chloride lev- Table 7. Cooling system make up and tower water data Items Unit Makeup Cooling Water Tower Water ph 7.3 8.5 Total Hardness mg/l as CaCO 3 198 737 Calcium Hardness mg/l as CaCO 3 130 510 Magnesium Hardness mg/l as CaCO 3 68 227 Total Alkalinity mg/l as CaCO 3 115 194 Conductivity µs/cm 856 3100 Turbidity FAU 0.5 5 Chloride mg/l 117 481 Sulfate mg/l 127 761 Silica mg/l as SiO 2 5.3 18 Iron mg/l 0.02 0.09 Zinc mg/l 0.88 el (See average cooling tower water in 2006 in Table 7). Through continuous improvement using GE 6 sigma tools, water control limit, chemicals dosage and treatment cost were optimized in condition of excellence performance. GE Water and Process Technologies has treated this system for more than 24 months. The corrosion rate and deposit rate are tested by coupons and bypass monitor tubes once every month. The average corrosion rate and deposit rate data are presented in Table 8. The carbon steel corrosion rate tendency is shown in Fig. 3. Both Table 8 and Fig. 3 show excellent corrosion and scale control performance. From the table 7 water data, we also see excellent corrosion control, since the iron concentration of the cooling water closely tracked its theoretical value, based on the iron level of the make up water and the cycles of concentration. The equipment inspections also showed excellent scale, corrosion and microbial control. 5. Conclusions (1) AEC, a patent non-phosphorous calcium carbonate scale inhibitor, has demonstrated better scale inhibition abilities than traditional phosphonates. In addition to its scale inhibition properties, AEC inhibits carbon steel cor- 20 CORROSION SCIENCE AND TECHNOLOGY Vol.7, No.1, 2008

THE APPLICATION OF NON-PHOSPHOROUS AEC PROGRAM IN COOLING WATER SYSTEMS OF PETROCHEMICAL INDUSTRY Table 8. Average corrosion and deposit rate Material Coupon Corrosion Rate Monitor Tube Corrosion Rate Monitor Tube Deposit [mpy] (mm/y) [mpy] (mm/y) Rate [mg/cm 2 /month] Carbon Steel 0.22 (0.0056) 0.95 (0.0242) 5.81 Stainless Steel 0.004 (0.0001) Brass 0.013 (0.0003) Corrosion rate [mpy] 1. 00 0. 80 0. 60 0. 40 0. 20 0. 00 May-05 Jun-05 Jul-05 Aug-05 Sep-05 Oct-05 Nov-05 Dec-05 Jan-06 Feb-06 Mar-06 Date Apr-06 May-06 Jun-06 Jul-06 Aug-06 Sep-06 Oct-06 Nov-06 Dec-06 Jan-07 Fig. 3. Carbon steel coupon corrosion rate rosion when used at high dosages. (2) AEC can be combined with zinc to form a non-phosphorous program to provide an environmentally acceptable program, which complied with the first grade standard of wastewater discharge limitations. (3) AEC/Zinc combinations have been found to be highly effective in controlling the corrosion of ferrous metals. AEC can provide good corrosion inhibition at high concentrations, while zinc is known to be an excellent cathodic inhibitor. The combination of the two inhibitors is a synergistic blend that is effective over a wide range of operating conditions and water chemistries. Acknowledgments The authors would like to acknowledge the efforts of Luo Hailong and Xu Jie of GE Water and Process Technologies for their hard work in the areas of monitor and control the projects. We would also like to acknowl edge the efforts of Raymond Post, Gary Geiger and Heo JuCheol of GE for coordinating the writing of this technical paper. References 1. V. Jovancicevic, The NACE International Annual Conference and Exposition, p. 226 (1996). 2. Roy Holliday, 8th European Symposium on corrosion inhibitors, 17, 493 (1995). 3. G. E. Geiger, International Water Conference, Pittsburgh, Pennsylvania (1995). 4. Carey William S, United States Patent, 5,871,691 (1999). 5. Xie Xiao, Industrial Water Treatment, 21, 36 (2001). 6. He Jixing, Petrochemical Technology, Vol.30 Supplement, 836 (2001). 7. Integrated wastewater discharge standard (GB 8978 1996). 8. Xiong Rongchun, Chinese Chemical Letters, 14, 955 (2003). 9. Zhang Bingru, Industrial Water Treatment, 26, 53 (2006). CORROSION SCIENCE AND TECHNOLOGY Vol.7, No.1, 2008 21