北京欧万电子科技有限公司 Production Quality Assurance Research & Development Test & Measurement NON-CONTACT TEMPERATURE MEASUREMENT GLASS INDUSTRY innovative infr

Similar documents
Production. Maintenance. Process Optimization. Quality Assurance NON-CONTACT TEMPERATURE MEASUREMENT METAL INDUSTRY. innovative infrared technology

Non-contact temperature measurement from 50 C to 2200 C

IMPAC Infrared Thermometers

GLASS INDUSTRY SOLUTIONS

Sensortherm. Digital Pyrometer. Temperature Measurement and Control. com

Product Overview. Pyrometers, Accessories, Software. Digital Self-Contained Pyrometer Series:

lumasense IMPAC Pyrometers Product Overview Highly Accurate Infrared Thermometers for Non-contact Temperature Measurements

8. PYROMETRY FUNDAMENTALS

Plastics Industry. Processing and Manufacturing. Noncontact Temperature Measurement Solutions. Major Applications

Industry, Universities Collaborate 11

Steel Industry Solutions Non-Contact Temperature Sensors for Improved Process Monitoring a nd Greater Efficiency

ONYX-M SINGLE-CHANNEL OPTICAL TEMPERATURE PYROMETER

THE INFRARED PROS. Non Contact Infrared Thermometers for the Glass Industry

IMPAC Infrared Thermometers

INDUSTRIAL INFRARED PYROMETERS. Williamson - Where Wavelength Matters

Industrial Infrared. Pyrometers. Williamson - Where Wavelength Matters

Digital Pyrometers PYROSPOT

Jewelry Laser Spot Welding Machine

TEMPERATURE MEASUREMENTS IN METAL REHEAT FURNACES

Highly Accurate Infrared Non Contact Pyrometers

CellaTemp PQ, PL Pyrometer Series

Laser Welding of Engineering Plastics

INTERPLANT STANDARD - STEEL INDUSTRY SPECIFICATION FOR INFRA-RED PYROMETERS IPSS:

OPERATION MANUAL OPTICAL THERMOMETERS FOR THE MEASURE OF TEMPERATURE PROFILES

High-Speed Infrared Imaging for Characterization of the Additive Manufacturing Process

PRODUCT OVERVIEW IMPAC Pyrometers

Intelligent Power Control for Quasi- Simultaneous laser welding. Saara Ruotsalainen VTT

TL-S, TL-GA USER MANUAL. -32 C to 2500 C NON-CONTACT T EMPERATURE MEASUREMENT - WORLDWIDE

Chapter 11. Measurement of Temparature. Oxford University Press All rights reserved.

Temperature measurement of metals regardless of emissivity

STEEL INDUSTRY SOLUTIONS

PYROMETER CONTROL FOR QUASI-SIMULTANEOUS LASER WELDING

1. BASIC CONCEPTS PYROMETRY 6 3. CHOOSING THE SPECTRAL RANGE METHODS FOR DETERMINING THE EMISSIVITY 9

Non-Contact Temperature Measurement

Thermophil INFRAsmart R 300 / R 301 / R 302

Thermal Diffusivity - Thermal Conductivity LFA 447

Development of New Technique for Continuous Molten Steel Temperature Measurement

CNC - LASER MACHINES OF THE SERIES LS Welding Cutting Hardening Drilling Structuring

We use the best and fastest new technology in optics, software, hardware and mechanical components.

STEEL PRODUCTION HOT ROLLING MILL

BOROFLOAT 33 & Functional Coatings: A Union of Inspiration & Quality

Compact flue gas analyser: testo 300 M-I

Exceptional Technology for Material Science TT DMA. Dynamic Mechanical Analyser

UNIT 3 Part 1 Temperature Measurements

This document is downloaded from the Digital Open Access Repository of VTT. VTT P.O. box 1000 FI VTT Finland

TOP PERFORMANCE IS OUR CONNECTION TO THE FUTURE.

PATTERNING OF OXIDE THIN FILMS BY UV-LASER ABLATION

PROBLEM 2: PREDICTING GLASS RIBBON SHAPE IN

INSPECTION LINE FOR RAILS

MEASURING MICROPARTICLE IMPACT CHARACTERISTICS UNDER REALISTIC GAS TURBINE CONDITIONS. A.G. Friedman, W.F. Ng Virginia Tech

Fig1: Melt pool size of LAMP vs. µlamp. The LAMP process s melt pool is x the area of the LAMP s melt pool.

Productivity versus Profitability in Vacuum Web Coating

Thermo Scientific GENESYS 10S Bio spectrophotometer

Non-Contact Temperature Measurement

Remote Sensing of CO from AIRS AIRS typically sees 82% of the globe each day

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Bruker JUWE G8 GALILEO ONH. High-End Melt-extraction Analyzer. Elemental Analysis. think forward

Contents Ⅰ Plastic laser welding. Ⅱ Laser soldering

Non-Contact Infrared Temperature Measurement for Industrial Process and Research Applications

Pyrometer CellaPort PT. for non-contact temperature measurement from 0 C to C

Pyrometric Temperature Measurement in the Glass Industry

11.3 Polishing with Laser Radiation

Properties of Inclined Silicon Carbide Thin Films Deposited by Vacuum Thermal Evaporation

Aluminium. Non-contact temperature measurement in aluminium processing

Sensors and measurement techniques for monitoring and control of the EAF process

Infrared Temperature Measurement Systems. Designed for the Aluminium Extrusion Industry

Infrared Absorption by Ferroelectric Thin Film Structures Utilizing Novel Conducting Oxides

EXPERIMENTAL TEMPERATURE ANALYSIS OF POWDER-BASED ELECTRON BEAM ADDITIVE MANUFACTURING. Steven Price*, James Lydon**, Ken Cooper**, Kevin Chou*

Skills and excellence formation on basis of Laboratory of Plasma Physics & Atomic Spectroscopy Institute of Spectroscopy (ISAN) of Russian Academy of

REDWAVE SORTING TECHNOLOGY

Thermal analysis of Laser Transmission Welding of thermoplastics: indicators of weld seam quality

Paper II. Non-contact Temperature Measurements using an Infrared Camera in Aerospace Welding Applications. Per Henrikson and Mikael Ericsson

Analyzing & Testing. Laser Flash Apparatus LFA 457 MicroFlash. Method, Technique, Applications of Thermal Diffusivity and Thermal Conductivity LFA 457

QUASI-SIMULTANEOUS LASER WELDING OF PLASTICS COMPARISON OF DIODE LASER WELDING AND FIBER LASER WELDING

Recent Progress in Droplet-Based Manufacturing Research

IRt/c Mission Increase Your Profitability

Price List. Calibration Fee

DIE SURFACE TEMPERATURE MONITORING

LASER TRANSMISSION WELDING OF THERMOPLASTIC POLYURETHANES: A ROBUST PROCESS WITH HIGH RELIABILITY

How to Maximize the Return on Investment. Monitoring and Inspection of Mechanical Systems by Using Infrared Thermography

BOD 21M Distance Sensors. Effortless performance High efficiency

ATTACHMENTES FOR APD 2000 PRO POWDER X-RAY DIFFRACTOMETER. Monochromators

Infrared Thermography : A versatile Technology for Condition Monitoring and Energy Conservation

Use of automation to improve productivity and quality in long product rolling mills

Understanding Extrusion

Quality Management of Laser Cladding Processes for Additive Manufacturing by new Methods of Visualization and Evaluation of Thermographic Data

Measuring on surfaces

Pyrometer CellaTemp PZ Profibus. for non-contact temperature measurement from 0 C to C

ZP Series of Small, High-sensitivity Infrared Gas Analyzers

RHEOLOGICAL PROPERTIES ROSAND RH7 & RH10 RHEOLOGICAL INSTRUMENTS BACKED WITH RHEOLOGICAL EXPERIENCE

P2Xe: compact hybrid panel bender. Perfect balance between space and consumption, productivity and flexibility. Within everybody s reach.

waterjet cutting expertise in Byjet The flexible waterjet cutting system for demanding applications

Coatings. Ion Assisted Deposition (IAD) process Advance Plasma Source (APS) plasma-ion assisted Deposition. Coatings on Optical Fibers

Product Overview. Highly Accurate Infrared Thermometers for Non-contact Temperature Measurements

OIML D 24 DOCUMENT. Edition 1996 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Total radiation pyrometers DE MÉTROLOGIE LÉGALE

For further information about our products and installation services please call to arrange a personal consultation.

ARE MORE PROFITABLE DURABLE INVESTMENTS THE ROBUST ALL-ROUNDER

OPERATION MANUAL OPTICAL THERMOMETERS

New Characterization Methods for Mechanical Properties. S. Hoffmann; Department of Ferrous Metallurgy (IEHK), RWTH Aachen University

Transcription:

北京欧万电子科技有限公司 Production Quality Assurance Research & Development Test & Measurement NON-CONTACT TEMPERATURE MEASUREMENT GLASS INDUSTRY

Glass industry TECHNOLOGY AND PHYSICS Influence from the surroundings The illustration shows that the transmissivity of air strongly depends on the wavelength. Strong flattening alternates with areas of high transmissivity the so-called atmospheric windows. The transmissivity in the longwave atmospheric window (8 14 µm) is constantly high whereas there are measurable alleviations by the atmosphere in the shortwave area, which may lead to false results. Typical measuring windows are 1.1 1.7 µm, 2 2.5 µm and 3 5 µm. Additional influences can arise from heat sources in the environment of the measuring object. To prevent wrong measuring results due to increased ambient temperatures, the infrared thermometer compensates the influence of ambient temperatures beforehand (as e.g. when measuring temperatures of glass surfaces in heating areas whereby the walls are hotter than the glass surfaces). A second tem-perature sensing head helps to generate accurate measuring results by automatically compensating the ambient temperatures and a correctly adjusted emissivity. T amb n Object T n obj = α Compensating ambient influences T amb n Radiation from ambient α = Absorption ρ = Reflectance τ = Transmission ε = Emissivity Emissivity and temperature measurement For the accurate measurement of temperatures, emissivity is a key factor. It is dependent on various influences and must be adjusted according to the application. ρ ε τ Sensor Transmissivity in % 100 75 50 Emissivity theoretically depends on the material, its surface quality, wavelength, the measuring angle and, in some cases, even the applied measuring configuration. Glass usually exhibits an emissivity of 0.85 in the longwave range (8 14 μm). In processes with higher temperatures glass surfaces are measured with 5.0 μm or 7.9 μm because in those spectral ranges the emissivity is 0.95. 25 0 2 4 6 8 10 12 14 16 Wavelength in µm The main advantage of 7.9 µm is the lower angle dependency of the glass surface reflection in this wavelength range. This means that the surface temperature can be measured independently of the reflection even at an inclined viewing angle. Spectral transmissivity of air (1 m, 32 C, 75 % r. F.) Dust, smoke and suspended matter in the atmosphere can pollute the optics and result in false measuring data. Here air purge collars (which are installed in front of the optics with compressed air) help to prevent deposition of suspended matter in front of the optics. Accessories for air and water cooling support the use of infrared thermometers even in hazardous surroundings. Emissivity Spectral emissivity of glass Wavelengh [µm] The CoolingJacket Advanced enables an operation within an ambient temperature of up to 315 C 2

Temperature measurement of glass Line scan with compact infrared camera Owan infrared cameras are equipped with licensefree PI Connect software. The software enables the cameras to operate as line scan cameras. Line scanners are traditionally used in the glass industry for various measurement procedures. In these devices, a point detector is coupled with a rotating mirror to consequently generate a linear optical scan of the object. These devices are bulky and expensive. Hot spot detection at glass bottle production If you measure temperatures of glass with IR thermometers or the special IR camera owan PI G7 it implies that you take care of reflection and transmissivity. A careful selection of the wavelength facilitates measurements of the glass surface as well as of the deeper layers of the glass. Wavelengths of 1.0 µm, 2.2 µm or 3.9 µm are appropriate for measuring deeper layers whereas 5 µm are recommended for surface measurements. If temperatures are low, you should use wavelengths between 8 and 14 µm in combination with an emissivity of 0.85 in order to compensate reflection. For this purpose a thermometer with short response time should be used as glass is a bad heat conductor and can change its surface temperature quickly. Transmissivity in % 100 80 60 When using an infrared camera as a line scanner, an arbitrary line is selected from the detector array. In addition to the more compact construction and the lower price, there are two significant benefits: the line to be scanned can be positioned anywhere using the software and the user receives a complete IR image quasi as additional information these are important advantages, especially during system setup. The cameras can accurately measure surface temperatures of moving measurement objects using minimal apertures. This function is of particular significance in the glass industry, since the glass temperature has a direct impact on the quality. During the production process, temperatures are measured accordingly at many points and it is possible to intervene in the process, when necessary, if there are deviations in setpoint temperatures. For example, the Owan PI 450 G7, a special IR camera for glass applications, can scan the complete glass width using in the float process (Up to 4 m) with an 80 lens using the diagonals as scan line at a height of 2.1 m. 40 Lines have FOV of up to 97 for detailed process analysis. 20 0 2 3 4 5 97 478 Pixel any number of lines Spectral transmissivity of glass Wavelengh [µm] Up to 80 Hz data recording of unlimited lines which in turn produce a thermal image of any given resolution Further information in our infrared basics brochure: www.bjowan.com 3

Applications of Temperature measurement technology PRODUCTION OF GLASS Production optimization in the float glass process After the tin bath, the flat glass band has a temperature of about 600 C; the first infrared camera in line-scan mode is applied for temperature monitoring at the transition to the cooling zone. The glass is transported through various cooling ranges in the cooling zone. Between the cooling ranges, infrared cameras are also installed in the cooling ranges for temperature monitoring, in order to guarantee optimal quality. Measurement areas at float glass production Software adfjustments for line-scan process Infrared cameras Melting process Float Tin bath Cooling > 1500 C 600 C Continious control during the production of container glass Container glass, meaning for example bottles in all sizes and forms, must be multiply monitored for its processrelevant temperature during the production process. When the molten glass exits through the feeder, the glass strand is cut. The thereby resulting molten glass drops must have a temperature of about 1000 C to ensure quality. Temperature measurement was previously only possible with point-measuring infrared thermometers due to the high velocity. The innovative Owan PI 1M now also enables this measurement via surface measurement with an image rate of up to 1000 Hz. During the forming process, which takes place at temperatures of over 500 C, infrared sensors are also used for monitoring. Since the process only takes a few seconds, the reaction of the sensors is of critical importance here. The thermal measurement of the glass can be influenced by direct measurement of the glass surface or indirect measurement of the surface of the forming tool for both the forming of the parison shape as well as during finishing of the mould. To complete the finishing process, another temperature control to reduce tension takes place in the containers. The glass is heated again and subsequently gradually cooled in a cooling tunnel over a period of up to 30 minutes. When the containers exit the heating zone, the cooling process is supported and controlled by temperature measurement. 4

Single-pane safety glass production with correct temperature measurement technology For the production of single-pane safety glass (SPSG), the cut and processed flat glass is heated in a furnace under continuous movement at over 600 C. During the transport of the heated glass in the pretension zone, an infrared camera monitors the temperature distribution on the glass surface in line-scan mode. During the pretension process, where the glass is shock-cooled, inhomogeneities can be compensated. The quality of the SPSG mainly depends on a homogeneous thermal treatment, which is ensured by the application of temperature measurement technology. Infrared camera with line scan mode Heating process Cooling process 600 C 50 C with line scan mode Measurement areas at SPSG production process 50 C Ensuring the quality of laminated safety glass Laminated safety glass (LSG) consists of at least two f lat panes of glass, which are laminated in a clean room with a sheet of PVB film between them. The temperature of the film can be monitored with infrared thermometers. In the pre-lamination furnace, the glass panes are heated in order to melt the film and simultaneously press the sandwich together, to prevent air pockets. During the transition to the autoclaves, the temperature distribution is monitored with an infrared camera, in order to adjust the heating elements in the pre-lamination furnace for subsequent panes, when necessary. Infrared thermometer Infrared camera with line scan mode Heating with IR radiation and rolling Infrared thermometer / Infrared camera Laminating room Final control Measurement areas at LSG production 5

Glass industry INFRARED CAMERAS AND INFRARED THERMOMETERS The IR thermometer s stainless steel measuring head is extremely small and can be employed in ambient temperatures of up to 85 C without additional cooling. A multi-installation of the pyrometers, e. g. in series as line scanner, is therefore cost-efficient and can be performed even in limited spaces. The temperature range is from 100 C to 1.650 C. CT G5 Due to its special spectral range of 5.0 µm, the pyrometer optris CT G5 is perfectly suited for the measurement of glass temperatures, e.g. during container glass production and vehicle glass production. The infrared thermometer CTlaser G5 allows for temperature measurement of smallest objects of 1 mm from a distance of 70 mm. Due to its very short response time of 10 ms it is often used for fast processes. CTlaser G5 With a spectral range of 5.0 µm, the two-part infrared thermometer optris CTlaser G5 is especially designed in precise measurement of glass surfaces. The devices are employed for temperature measurement in e.g. manufacturing processes of vehicle glass and and flat glass. Also in the manufacturing of laboratory glass equipment or the production of glass bottles, the pyrometer delivers excellent results and is thus employed for quality assurance and process coordination. The infrared thermometer CSlaser G5HF has been specifically designed for temperature measurement of glass. Its standardized two-wire interface provides a reliable measuring data transmission and allows for an easy integration of the temperature sensors into a PLC. The IR thermometer is additionally equipped with an innovative double laser visor for a precise marking of the measuring spot. A variety of optics ensures high adaptability with diverse applications. CSlaser G5HF The CSlaser G5 is perfectly suited for tempera-ture control of production processes of flat glass and vehicle glass. Also, the measurement during cooling and heating processes of single-pane safety glass and laminated sheets safety glass is important. 6

The infrared camera PI 450 G7 is the newest model of the PI series of Owan. It s a special development for the glass industry with a spectral range of 7.9 μm. The temperature range of 200 C bis 1500 C allows the implementation in diverse applications in production, dressing and further processing of glass. PI 450 G7 The infrared camera has to be used when temperature values within a field should be detected. In due to the low price an infrared camera could be the better solution in comparison to rows of infrared thermometers. Line scan camera The infrared thermometer CTfast LT has an extremely short response time of 6 ms. The unchoppered sensor allows a continuous temperature surveillance of fast processes in a spectrum of 50 C up to 975 C. The thermal imager owan PI 160 allows for exact measurements from an object size of 1.5 mm on and is, due to its measurement speed of 120 Hz, perfectly suited for employment in research and development, test stations, and process automation as well as for portable measurement tasks. For fast processes PI 160 and CTfast LT Both products are preferably used in the packaging industry and in bottling plants. In mass production, it is essential that high-output processes are monitored continuously and without friction. Deciding which of the two products should be used, depends on the measuring area. From a measurement of more than 7 measuring points, it is less expensive to use an infrared camera. The pyrometer CThot LT has been developed for the most extreme conditions in high-temperature areas and is acclaimed for its especially high temperature resistance. Employment of the infrared thermometer in ambient temperatures of up to 250 C with- out additional cooling poses absolutely no problems. Due to the mentioned features, the IR pyrometer is especially suited for applications in glass industries. On request, the IR thermometers are available as models for applications in explosion-threatened areas. CThot LT The CThot LT is used in production processes and refining processes of glass. Due to its extremely high temperature resistance, it is also suitable for ovens and closed chambers. 7