STERI-SOFT HIGH FOOT TRAFFIC, ULTRAVIOLET RESISTANT, URETHANE RESILIENT FLOORING SYSTEM, 1/8 GREEN BUILDING FEATURES TYPICAL APPLICATIONS

Similar documents
MEMBRANE 510/510R Low VOC Flexibilized, Urethane Membrane mils

STERI-FLAKE 470 HYBRID ESTER POLYMER, LIGHT-MEDIUM TRAFFIC, FLAKE FILLED FLOOR SYSTEM LOW ODOR MMA ALTERNATIVE FEATURES

STERI-QUARTZ B SOLVENT FREE, UV RESISTANT, LIGHT-MEDIUM TRAFFIC, DECORATIVE QUARTZ FLOOR SYSTEM, 1/16-3/16 GREEN BUILDING FEATURES

STERI-QUARTZ GP GENERAL PURPOSE BROADCAST, UV RESISTANT, LIGHT-MEDIUM DECORATIVE QUARTZ FLOOR SYSTEM, 1/16 3/16

POLYMER ALLOY 1000/1000SF HIGH SOLIDS, MULTI-FUNCTIONAL, SEMI-SELF LEVELING OR SEEDED EPOXY FLOOR TOPPING

POLYMER ALLOY 2000/2000SF 100% SOLIDS, MULTI-FUNCTIONAL SEMI-SELF LEVELING OR SEEDED EPOXY FLOOR TOPPING

STERI-FLEX SPECIFICATIONS FEATURES

PERFORMANCE, 100% SOLIDS,

PROTECTO-CRETE 800/800SF

FLEXIBILIZED TROWEL APPLIED, GLASS

100% Solids, Multi Functional, Pigmented High Build Epoxy Novolac Coating, For Wall & Ceiling Applications mils

POLYMER CONCRETE 800 NON-SHRINK VINYL ESTER POLYMER CONCRETE, CONCENTRATED HYDROFLUORIC ACID RESISTANCE

PROTECTO-FLEX 100XT. TROWEL APPLIED, GLASS REINFORCED, EPOXY LINING WITH NOVOLAC EPOXY TOPCOAT MILS ( mm)

PROTECTO-CRETE 900/900SF

PROTECTO-COAT 900/905

PROTECTO-FLEX 310. Corporate Offices 1818 Miller Parkway Streetsboro, OH FAX

PROTECTO-COAT 900/905

FEATURES. 150 F- Continuous NOT recommended for area with Thermal Shock. DUD IC K, INC Miller Parkway. Streetsboro, OH

PROTECTO-COAT 800/805

STERI-COAT P. Multi Functional, Pigmented High Build Epoxy Novolac Coating, For Wall & Ceiling Applications mils GREEN BUILDING FEATURES

PROTECTO-CRETE 140T/140TSF

POLYMER CONCRETE 100 EPOXY POLYMER CONCRETE DILUTE ACIDS RESISTANCE

PROTECTO-FLEX 310. Corporate Offices 1818 Miller Parkway Streetsboro, OH FAX

PROTECTO-GLASS 160XT. Corporate Offices 1818 Miller Parkway Streetsboro, OH FAX

PROTECTO-COAT 900FR/905FR FIRE RETARDANT CLASS A FLAKE FILLED, NOVOLAC VINYL ESTER COATING, MILS (1.0 mm)

PROTECTO-FLEX 805. TROWEL APPLIED, GLASS REINFORCED, EPOXY LINING, WITH A GRAPHITE FILLED VINYL ESTER TOPCOAT MILS (2.2-2.

PROTECTO-FLEX 905. Corporate Offices 1818 Miller Parkway Streetsboro, OH FAX

PROTECTO-FLEX 805. TROWEL APPLIED, GLASS REINFORCED, EPOXY LINING, WITH A GRAPHITE FILLED VINYL ESTER TOPCOAT MILS (2.2-2.

DUDICK, INC. FEATURES. DUDICK. INC Miller Parkway. Streetsboro, OR PROTECTO-FLEX 800

PROTECTO-COAT EPG EPOXY PHENOLIC GLASS FLAKE COATING

PROTECTO-FLEX 900. Corporate Offices 1818 Miller Parkway Streetsboro, OH FAX SPECIFICATIONS FEATURES

- 250 F Intermittent. 1 DUDICK, INC Miller Parkway. Streetsboro, OR FEATURES

PROTECTO-GLASS 860/865

PROTECTO-GLASS 960/965

Application Guidelines for PPC Coatings Flooring

SECTION ELASTOMERIC LIQUID FLOORING

KEY 9418 MMA BINDER DESCRIPTION KEY ADVANTAGES KEY CONSIDERATIONS COMPOSITION COLOR SELECTION SURFACE PREPARATION

Installation Instructions

Vapor-Clear. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring

TL-250 Glass Flake Filled, Vinyl Ester Tank Lining System

NSP SPECIALTY PRODUCTS Technical Data Sheet. NSP 120 High Performance Epoxy Coating

TL-250AR Abrasion Resistant, Glass Flake Filled, Vinyl Ester Tank Lining System

Sanitile 945 SL PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. 100% solids epoxy

Refer to Substrates & Surface Preparation.

Property Test Method Typical Value

Specifications. Specifications (Architectual) Metallic System. Metallic System

DUR-A-FLEX, Inc. Page 1 of 5

Florock Seamless Flooring Systems

Carboxane 950 Metallic

SECTION RESINOUS FLOORING

TL-280 Sprayable Flake Glass Vinyl Ester Lining System

1.2 SUMMERY A. Section Includes: 1. High-Performance Polyurethane Resinous flooring systems. 2. Decorative Polyurethane Resinous flooring systems.

DIVISION 9 - FINISHES Section Coatings

SECTION A. American Society for Testing and Materials (ASTM):

Technical Data Sheet PaveCoat Product Description

FLEXMAR 3-Coat High-Build Colored Quartz System

Tennant Company October North Lilac Drive Minneapolis, Minnesota Guide Specification

Installation Instructions

SECTION A. American Society for Testing and Materials (ASTM):

Protective Industrial Polymers - USA Manufacturer s Specification February 11, 2015

LS 486 / GLASS MAT REINFORCED SYSTEM A LAVALINE - SERIES 48 SYSTEM / Vinyl Ester CONCRETE & MASONRY SURFACES

Rust-Oleum Industrial Brands Specification

SECTION A. American Society for Testing and Materials (ASTM):

OVERKOTE E-100 Epoxy Floor Coating Technical Data

DIVISION 9 FINISHES Section Floor Finishes

Solventless two-component crosslinked epoxy

Installation Instructions

SECTION RESINOUS FLOORING PLEXIQUARTZ BROADCAST SKID-RESISTANT QUARTZ SYSTEM

A/D Firefilm III PRODUCT DATA SHEET

Flowfast SR (3mm) Technical Profile

Seal- Krete High Performance System

TL-225-NS Teflon Filled, Vinyl Ester Coating & Lining

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

DUR-A-FLEX, Inc. Page 1 of 6

1/16 Single Broadcast Polymer Flooring System

SECTION EPOXY MOSAIC COMPOSITION FLOORING Dex-O-Tex Cheminert Terracolor

SECTION A. American Society for Testing and Materials (ASTM):

Specifier Notes: Edit the following list as required by the project. List other sections with work directly related to the floor coating.

Rust-Oleum Industrial Brands Specification

APF Epoxy 752 CLEAN ROOM FORMULATIONS, CHEMICAL RESISTANT THIXOTROPIC CLEAR & PIGMENTED EPOXY

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX Products

1.04 REFERENCES STANDARDS.1 For reference standards tests & results refer to Manufactures Product Data Sheets

20-30 mils ( microns) per coat mils ( microns) in two or more coats

Action Herculan MF 7+2 Synthetic Floor System

Rust-Oleum Industrial Brands Specification

Refer to Substrates & Surface Preparation.

Rust-Oleum Industrial Brands Specification

DIVISION 7 THERMAL AND MOISTURE PROTECTION Section Traffic Coatings

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

1.1 This procedure governs the installation of PENNTROWEL UT500 Polyurethane Mortar Flooring Systems CE-286, CE-287 and CE-288.

Advantages USDA Compliant Chemical Resistant 100% Solids High Build Seamless Easy Clean Up Durable Decorative Variety of Colors Unique Effects

A. This Section includes resinous flooring systems with epoxy body coat(s).

Specifier Notes: Edit the following list as required by the project. List other sections with work directly related to the floor coating.

SECTION A. American Society for Testing and Materials (ASTM):

Flowfast SRQ (2mm) Technical Profile

Product Data. Products Available. A wide range of products designed to complement our specialty polymer floor coating systems.

Resists a very wide range of organic and inorganic acids, alkalis, amines, salts and solvents.

Florock Seamless Flooring Systems

SECTION A. American Society for Testing and Materials (ASTM):

Installation Instructions

Transcription:

GREEN BUILDING FEATURES * Steri-Soft contributes toward satisfying credit EQ 4.2 under LEED. 100% Resilient Flooring Low emitting material Contains 27% post consumer recycled product Processed and manufactured in Ohio VOC compliant California Rule 1113, 9/6/13 APPLICATION FEATURES Ergonomic Outstanding UV Stability Acoustic Noise Reduction Enhanced Slip Resistance Seamless Easy to Maintain Surface Anti-Microbial Agents are available as an option Excellent Durability and Chemical Resistance The LEED (Leadership in Energy and Environmental Design) Green Building Rating System is a nationally accepted benchmark for Design, Construction, and Operation of High Performance Green Buildings. LEED and related logo is a trademark owned by the U.S. Green Building Council and is used by permission. * Products are not reviewed or certified under the LEED Rating System. LEED credit requirements cover the performance of materials in aggregate, not the performance of individual products or brands. For more information on LEED, visit www.usgbc.org/leed. TYPICAL APPLICATIONS Clean Rooms Offices Medical Facilities Educational Facilities Lobbies Hallways Dry Laboratories Small Animal Vivariums Commercial/Institutional Facilities CHEMICAL RESISTANCE Please consult Dudick, Inc. for complete chemical resistance information. COLORS Available in standard color patterns. Consult Dudick, Inc. for complete information. TYPICAL PHYSICAL PROPERTIES Hardness 85 ASTM D-2240 Shore A Water Absorption 0.1 % ASTM D-570 Impact Resistance > 160 in. / ASTM D-4226 pound Tensile Bond Cohesive Failure ASTM D-4541 Strength of Concrete Static Load Limit 0.002in./0.05m m ASTM F-970 125 lb./57 kg.load Residual Indentation <1% thickness ASTM F1914 140lb. /64kg. load Noise Reduction 0.05 ASTM C-423 Coefficient With Optional Anti-Microbial additives: Fungus Resistance SPECIFICATIONS No Growth U.S. Mil Std. 810E system shall be a 1/8 inch* medium traffic floor that consists of high solids, moisture tolerant primer, urethane resilient bodycoat, and a UV stable sealer coat. 1 *For thick applications, consult a Dudick representative.

is manufactured by Dudick, Inc. and applied in accordance with the manufacturer s recommendations. THE SYSTEM Steri-Soft consists of a moisture tolerant primer, gauge raked bodycoat and a highly UV stable topcoat. This total system provides a strongly bonded monolithic floor with excellent physical properties. Steri-Soft is only intended for interior applications and consists of the following components. Primer: The prepared concrete surface is primed with Steri-Soft Primer 87 to provide the wetting out required for good bonding. Do not allow primer to puddle. Allow the Steri-Soft Steri-Soft Primer 87 to cure a minimum of 24 hours before applying Steri-Soft Flake Bodycoat. Bodycoat: The seamless, resilient and decorative bodycoat utilizes flexible urethane resin binders to provide a seamless floor that offers ergonomic comfort and acoustical noise reduction. Sealer: The high solids satin finish sealer provides exceptional UV stability with added abrasion resistance. Cove: Cove base installation with this material is not recommended. Contact Dudick representative for cove base recommendation. ESTIMATING QUANTITIES AND ORDER BILL OF MATERIAL APPROXIMATE SQUARE FEET PER GALLON ** PRIMER 87 Primer 150-200 ft 2 Bodycoat 12-13 ft 2 / gallon @ 1/8 Sealer 50 Option: Sealer 30 400-500 ft 2 @ 3-4 mils WFT 250-300 ft 2 @ 6 mils WFT Coverage rates will ultimately be determined by applied thickness and the degree of broadcast coverage. **Quantities shown are for estimating purposes only. Coverages will vary due to porosity of substrate and other environmental conditions. All quantities are estimated and will be affected by job conditions and workmanship. APPLICATION INSTRUCTIONS SURFACE PREPARATION Concrete must be prepared mechanically to remove surface laitance. Oils, grease or other contaminant must be removed prior to surface preparation. Concrete must be free of curing compounds and form release agents. Surface texture should be similar to 60-80 grit sandpaper or the visual standard, CSP-3 from the International Concrete Repair Institute. The prepared surface should have a nominal tensile strength of 250 PSI per ASTM D-4541. All concrete substrates must be checked for moisture prior to primer application using the Plastic Sheet Test per ASTM D-4263. Additional surface preparation will be required if a 60-80 grit texture is not achieved and the surface laitance not completely removed with the first mechanical preparation procedure. Mechanical preparation removes laitance, exposing honeycombs or voids beneath the surface which must be filled with Scratch Coat 300. (Refer to separate product bulletin) ENVIRONMENTAL CONDITIONS Temperature of the concrete substrate must be between 60ºF and 90ºF. Relative humidity must not exceed 75%. Substrate temperature must be 5ºF above the Dew Point. PRIMING PRIMER 87 MIX RATIO (BY VOLUME) 79 fl.oz. 49 fl.oz. PRIMER 87 POT LIFE TEMPERATURE PRIMER 87 50ºF 90 min. 75ºF 60 min. 90ºF 30 min. 2

PRIMING Concrete: Mix the pre-measured units of Steri-Soft Primer 87 with. Prime all concrete surfaces to be coated with Steri-Soft Primer 87 at 3-4 mils WFT. Do not allow the primer to puddle. Basecoat should be applied only after the Steri-Soft Primer 87 has cured a minimum 24 hours. BODYCOAT MIX RATIO (BY VOLUME) *For a unit combine the following: Do not split units SEALER 50 SATIN FINISH, PIGMENTED MIX RATIO (BY VOLUME) POT LIFE AND CURE TIME BODY COAT Temperature Pot Life 60ºF 60 min. 75ºF 40 min. 90ºF 30 min. RECOAT TIME MINIMUM MAXIMUM Steri-Soft 24 hr. @ 75 F 120 hr. Primer 87 Body Coat 16 hr. 120 hr. BODYCOAT Before beginning application: Curing by-product vapors can slow cure. Assure that there is air movement, exhaust, and fresh make-up air, especially in floor-to-wall and wall-to-wall corners.. Pre-mix Steri-Soft Bodycoat resin and hardener separately for 3 minutes until uniform. The Bodycoat is most easily blended using a stainless steel propeller, 5 diameter and ½ bore. Combine pre-measured and and stir for approximately 2-3 minutes, thoroughly scrape the sides and bottom of the container and re-mix for another 30 seconds. Pour mixed bodycoat directly onto the primed concrete. The mix should be spread over the floor with a Midwest CAM Gauge Rake @ 1/8-3/16. Allow Bodycoat to cure for 18 hours @ 75 o F before applying sealer. Urethane products are very sensitive to minimum re-coat times and temperatures. Contact Dudick representative for more information. SEALER Before beginning application: Curing by-product vapors can slow cure. Assure that there is air movement, exhaust, and fresh make-up air, especially in floor-to-wall and wall-to-wall corners. This will assure that vapor laden air/environment will not impact curing. Assure that application personnel are equipped with respirators fitted with approved organic vapor cartridges. Pre-mix Sealer 50 resin and hardener separately for 3 minutes until uniform. Combine pre-measured and and stir for approximately 2-3 minutes. Thoroughly scrape sides and bottom of the container and re-mix for another 30 seconds. Apply Sealer 50 using a flat squeegee and back roll with a high quality 3/16 nap roller. If using Sealer 50 with added glass beads, use 5 mil squeegee. Apply at a spread rate of 450-500 ft.² per gallon. 3

NOTES The pot life of Steri-Soft system components will depend upon the temperature. To prevent material waste and avoid damage to equipment, do not mix more material than can be used according to the corresponding tables. Do not attempt to store mixed material. Residual material should be properly disposed of at the end of each work period. Application of Steri-Soft in direct sunlight may lead to blistering, pinholes, or wrinkling due to outgassing of air in the concrete and high substrate temperatures. Double priming, shading or evening application may be required. Consult a Dudick representative. CLEAN UP Use S-10 Cleaning Solvent to clean tools and equipment. Acetone and MEK may also be used. DO NOT USE LACQUER THINNER. SHIPPING Refer to Material Safety Data Sheets. Exposure to resins and hardeners through direct skin contact and/or inhalation may cause severe dermatitis reactions in some people. Cleanliness of the skin and clothing is critical and must be of paramount concern. Fumes are flammable and heavier than air. Proper ventilation should be maintained to minimize breathing of concentrated fumes. Suitable respirators should be used during application. Safety glasses, gloves, and suitable protective clothing must be worn at all times during application. If contact with hardeners occurs, remove any clothing involved and flush the skin with flowing water. Discard the clothing. Do not attempt to wash and reuse it. The components of the Steri-Soft System liquid can be removed with S-10 Cleaning Solvent, MEK, or Acetone. Keep open flames and sparks away from the area where materials are being mixed and applied. If a rash occurs, remove the individual from the work area and seek a physician s care for dermatitis. STORAGE Warning: All Dudick products classified by DOT with white, yellow or red labels must not be mixed or stored together as an explosive reaction can occur. All products should be stored in a cool, dry area, away from open flames, sparks, or other hazards. When properly stored in their original, unopened containers at 50 F-75 F, the Steri-Soft Primer 87 will have a 6-month self life. Steri-Soft components will have a three-month shelf life. Containers that have been opened will have a shorter shelf life. Storage in direct sunlight or excessive heat will reduce working time and shelf life. SAFETY M.S.D.S.: Material Safety Data Sheets must always be read before using products. The components of the Steri- Soft Systems are intended for application by experienced, professional personnel. Dudick, Inc. can supply supervision to help determine that the surface has been properly prepared, the ingredients correctly mixed, and the materials properly and safely applied. If Steri-Soft is to be applied by your own personnel or by a third party contractor, please be sure that they are aware of the following safety precautions: In case of eye contact, flush with water for at least 15 minutes and consult a physician. If swallowed, do not induce vomiting; call a physician immediately. NOTE: Dudick, Inc. ( Dudick ) warrants all goods of its manufacture to be as represented in its catalogs and that the manufacture of its products by its employees or subcontractors shall be performed in a workmanlike manner. Dudick s sole obligation under this warranty shall be to replace any material which its examination shall disclose to be defective. Dudick makes no warranty concerning the suitability of its product for application to any surface, it being understood that the goods have been selected and the application ordered by the Purchaser. DUDICK, INC. MAKES NO WARRANTY, EXPRESS OR IMPLIED, THAT THE GOODS SHALL BE MERCHANTABLE OR THAT THE GOODS ARE FIT FOR ANY PARTICULAR PURPOSE. THE WARRANTY OF REPAIR OR REPLACEMENT SET FORTH HEREIN IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES ARISING BY LAW OR OTHERWISE; AND DUDICK INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DOWN TIME, DAMAGES TO PROPERTY OF THE PURCHASER OR 4

OTHER PERSONS, OR DAMAGES FOR WHICH THE PURCHASER MAY BE LIABLE TO OTHER PERSONS, WHETHER OR NOT OCCASIONED BY DUDICK S NEGLIGENCE. This warranty shall not be extended, altered or varied except by written instrument signed by Dudick and Purchaser. 5/22/17 5