City of Santa Monica Building and Safety Division

Similar documents
TOWN OF PERINTON 1350 TURK HILL ROAD. FAIRPORT, NEW YORK (585) , Fax: (585) ,

Single Family Dwelling Documents Preparation and Plan Review Guidelines California Residential Code (CRC).

RESIDENTIAL BUILDING REQUIREMENTS

RESIDENTIAL REMODELING AND BASEMENT FINISH

2003 International Residential Building Code

CITY OF DANA POINT WINDOW REPLACEMENTS FOR R-3 B030 WINDOWS

2018 IRC Sections R303 through R310 Building Planning II

Building Department Informational Handout. Residential Window Replacement Requirements

* RESIDENTIAL PLAN REVIEW *

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

WINDOW AND DOOR REPLACEMENT SAMPLE PLAN

FRAMING INSPECTION GENERAL

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.

Adult Family Home Inspections

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

2015 BUILDING CODES APPENDIX Q TINY HOUSES. Routt County Regional Building Department

Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL Tel: Fax:

2012 IRC Sections R303 R310 Building Planning II

One and Two Family Additions

(Statute, Rule, FBC, Industry) FBC 406.3, see also FBC No provisions in FBC or FS

RESIDENTIAL BASEMENT ALTERATIONS GUIDE

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

General Residential Code Requirements

General Residential Code Requirements

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

Inspecting the Means of Egress Course

General Residential Code Requirements

Minimum Requirements for Residential Occupancy Codes and FAQs

Inspection Checklist Residential Building Final July 2016

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

RESIDENTIAL STAIRWAYS, HANDRAILS,

2012 Code Update Training

Village of Glen Ellyn Basement Remodeling Project Guidelines

Continuing Certificate of Occupancy Pre-Inspection Checklist

SITE PLAN SCALE: 1/8"=1'-0" NORTH

RENTAL INSPECTION CHECKLIST. Helpful Definitions: Egress: the free and unobstructed access to the exterior of a habitable space.

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

General Building Information

City of New Hope Community Development 4401 Xylon Ave N New Hope MN Phone: Fax: newhopemn.gov

CTC MEETING #25 CHILD WINDOW SAFETY REPORT

Residential Building Plans

BUILDING PERMIT APPLICATION

311.7 Stairways Width Headroom. Exception: Walkline Stair treads and risers Tread depth.

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION

CITY OF OAK CREEK SINGLE FAMILY & TWO-FAMILY CONSTRUCTION/PERMIT REQUIREMENTS

INTERNATIONAL CODE INTERPRETATIONS

SFR SUBMITTAL REQUIREMENTS

Schedule A. a representative appointed from among persons nominated by the Nova Scotia Accessibility Advisory Board.

Screen & 3-Season Porches

BUILDING INSPECTION DIVISION Vacant Property Notice Exterior & Interior Inspection Checklist

CARBON MONOXIDE ALARMS

EGRESS AZMIR SULTANA NICOLAS MIMU SAKUMA EDWIN VEGA CHAMORRO

Typical Finished Basement Details

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

APPLICATION NUMBER:, TAX MAP KEY: STREET ADDRESS:, PRPOJECT: APPLICANT:, PHONE NO: MAILING ADDRESS:, FAX NO:

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

Pulaski County, Virginia

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL)

Administrative Changes

International Code INTERPRETATIONS

INDIANA COUNTY Office of Planning and Development 801 Water Street Indiana, PA (724) Fax (724)

Permit Posting and Inspection Procedures

CITY OF DALY CITY DEPARTMENT OF ECONOMIC AND COMMUNITY DEVELOPMENT, BUILDING DIVISION

Repair or replace section of driveway, approach, or sidewalk that are a trip hazard.

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

Accessory Dwelling Unit (ADU) Correction Sheet

RESIDENTIAL PLAN CHECK LIST

SUBMITTAL REQUIREMENTS FOR SINGLE FAMILY DWELLINGS

By James Tente, MCP, CBO,CFM

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood

Contractor/Owner initials are verification that items #1 and #2 and items (a) thru (g) above are included in the submitted plan/drawing.

Excerpts from: International Residential Code 2009

UCC Permit Application Procedures

REHABILITATION WORK WRITE-UP. Physical Address: Administrator: Grantee:

R vertical and horizontal.

2006 INTERNATIONAL RESIDENTIAL CODE PLAN ATTACHMENT

HOW TO USE THIS GUIDE:

Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date

Property Inspection Checklist

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER

Town of Pawling Residential Building Permit Application

Residential Rental Property Self-Certification Checklist Rental property municipal address Rental Property number Office Use Only License No.

Office use only 115 S. FRANKLIN AVE. Permit No. POLO, IL 61064

Data Accuracy. Below Ground Finished* Square Footage: Measured below ground level as it appears from the front view of the building.

Bulletin BLD May 24, 2013 (Updated September 26, 2017) SECONDARY SUITES

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

CITY OF OCEANSIDE. Single Family Dwelling Stairways/Guards. Informational Bulletin

Visual Interpretation Of The

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

HARPER WOODS BUILDING DEPARTMENT PROCEDURES FOR OBTAINING CERTIFICATE OF OCCUPANCY

CITY OF SASKATOON COUNCIL POLICY

Transcription:

This is to be used as a general checklist; it is not inclusive of all code requirements and inspection criteria. GENERAL REQUIREMENTS Approved plans and inspection card to be on job site. (CBC 106.4.2 & 108.2) Read plans including notes and any special Conditions of Approval Approved plans to match and correctly reflect work completed. Verify all required signatures on Job card. Plumbing, Mechanical, Electrical, Public Works, Water dept., Fire dept., Business License. Verify exterior requirements are completed as per approved plans, no hazardous visual obstruction or other unsafe conditions including any Planning Dept. conditions Verify the address 4 contrasting numbers visible from street (and rear if an alley) S.M.M.C 8.48.120 (B) 1 Egress from rear yards to the public way. (Two means of egress required for > sq. ft.) Garage door safety devices to be tested Removal of potable toilet, job fence and debris S.M.M.C 5.08.060 EXTERIOR AREAS Landing at exterior doors, Max slope per foot. CBC 1003.3.1.6 Doors may open at a landing that is not more than 8 lower than the floor level, provided the door does not swing over the landing (CBC 1003.3.1.6 exc. 1.2.) Grading and proper drainage away from structure. CBC 1804.7 Building must be weather tight. (Thresholds and weather-stripping.) Calif. Energy Commission, CBC 1403.5.1 Revised 12/02/05 Page 1 of 5

Weep screed to earth and to paved areas CBC 2506.5 Foundation supporting wood shall extend at least 6 above adjacent finish grade CBC 1806.1 Rain gutters in hillside areas. Over flow drain to be same size as roof drain and have completely separate drain line, if over flow scupper is used it is to be times larger than primary drain; all overflow drains to be two inches higher than primary drain. CBC 1506.3 ABS vent pipes exposed to sunlight shall be protected by water base synthetic latex paint. CPC IS-5-313 Degree of driveway slope not to exceed 15% Verify tempered glass locations, all doors, and sidelights adjacent to doors, windows with in 40 of locking devices. See walkthrough hazard requirements CBC. 2406.4.7 Building security shall be in accordance with the Uniform Building Security Code. Swimming pools see handout and CBC section 680. Gates and door need to be selfclosing, self-latching and open away form pools. Gate latch must be higher than for existing pools and for all new pools. Doors accessing pool area to have an alarm audible for seconds throughout house. Alarm must reset automatically. Pool fencing / barrier/ enclosure must be tall, difficult to climb over, maximum vertical clearance from ground to the bottom of the enclosure of or less. Gaps or voids not to allow passage of a sphere equal to or greater than inches in diameter. OR The pool shall be equipped with an approved safety cover. Labeled ASTM Standard F or the residence (Garage & guesthouses) shall be equipped with exit alarms on those doors providing direct access to the pool. Underfloor and attic screens. sq. foot per sq. Ft. of underfloor space. Vents to be evenly space along at least two sides.cbc.2306.7 Revised 12/02/05 Page 2 of 5

INTERIOR AREAS Verify hearth dimensions at fireplace. Fireplace openings less than 6 sq. ft. Then hearth depth and from each side. If hearth opening is equal to or larger than 6-sq. ft. then the hearth depth will be and from each side of the opening. (CBC 3102.7.12) Hearth extensions for factory built fireplaces shall conform to terms of their listing. Fireplace vertical surfaces clearances; mantles combustible materials shall not be placed within 6 of fireplace openings. No combustible material within 12 of fireplace openings shall project more than for each clearance from such openings. (Example ¾ projection needs 6 clearance or 1 ½ projection needs a 12 clearance.) CBC 3102.7.8 Verify that fireplace chase cap and spark arrestor has been installed as per manufacturer specifications. CBC 3102.5.1 Smoke detectors are needed when interior work exceeds $ and a permit is required or when one or more sleeping rooms are added in an existing dwelling. Smoke detectors may be solely battery operated when installed in existing buildings. CBC 310.9. In dwelling units a smoke detector is needed in each sleeping room and hallways or area giving access to each separate sleeping room. CBC 310.9 Smoke detectors are to be installed in each story and the basement. Where the ceiling height of a room opens to the hallway serving the bedroom exceeds that of the hallway. CBC 310.9. When smoke detectors are newly hard wired they need to be interconnected and with battery back up CBC 310.9. At least one window in a sleeping area to comply with egress requirements. Maximum. Sill height of above finished floor, Minimum width, minimum, height, and sq. Ft. minimum opening. CBC 310.4 All showers door to open outward and are a minimum dimension of 22. CBC 2407 House to garage door is to be self-closing tight fitting solid wood or have a -minute labeled fire protection rating. CBC 302.4ex.3 Revised 12/02/05 Page 3 of 5

Interior enamel painting is required in the kitchen and bathrooms. Waterproof floor coverings at kitchen and baths. Range vertical clearance 30 (24 if protected with millboard and 28 ga.)cbc 917.1 Check exterior doors and windows for locks per S.M.M.C.8.48.120, CBC 1003.3.8 (security) Headroom in habitable space, kitchens, halls, bathrooms and toilet compartments CBC 310.6.1 GUARDRAILS, STAIRS AND HANDRAILS Handgrip portion of handrail is not to be less than nor more than 2 in cross sectional and less than of projection on each side. Trim, stringers and other projects not more than. CBC 1003.3.3.6 & 1003.3.2 Handrail projection space not less than between the wall and the handrail. Handrail to have no sharp corners. CBC 1003.3.3.6 Openings located in handrails / guardrails shall not allow a sphere to pass through the inner rails. CBC 509.3 The triangular opening formed by the risers and treads at the bottom rail of the guardrail and openings between treads on open risers shall not allow a sphere to pass through. CBC 509.3 Treads must be a minimum of and risers a minimum of and a maximum. Except as permitted for winding, UBC.1003.3.3.8.2 circular and spiral stairs, CBC 1003.3.8.2 the maximum variance for treads and risers over the entire run shall not exceed 3/8 CBC 1003.3.3.3 Headroom above stairs measured vertically from the plane parallel and tangent to the stairs tread nosing to the soffit above at all points. CBC 1003.3.3.4 (Height for stairs 6 8 -For winders 6 6 ) Handrail heights at stairs to above nosing of the stairs. CBC 1003.3.3.6 Revised 12/02/05 Page 4 of 5

Verify guardrail height of all floors greater than in height from adjacent floor level. CBC 106.2#7 509.1 The minimum height for residential guardrails is Guardrails in multi-unit complexes unless within an individual unit only will be required to be minimum in height. CBC 509.2 All glazing subject to human impact is to comply with CBC 2406.3 Finish floor at stairs and stair landings must be installed for final inspection. CBC 1003.3.3.3 Revised 12/02/05 Page 5 of 5