Dedicated System ICS-00 Series Standard Features Dual Piston Pump Thermostated Digital Conductivity Cell Electrolytic Suppression LED Status Front Panel Chromeleon SE Control Software Eluent regenerator control Options Eluent Regeneration (RFIC-ER ) Column Heater In-Line Vacuum Degas Full Chromeleon Chromatography Data System Sample Preparation Valve, PEEK, High Pressure, 2-Position, - or 0-Port ICS-00 Series Standard Features Touch Pad Front Panel Control Dual Piston Pump Thermostated Digital Conductivity Cell Electrolytic Suppression Column Heater Chromeleon Chromatography Data System Eluent regenerator control Options Eluent Regeneration (RFIC-ER) In-Line Vacuum Degas Sample Preparation Valve, PEEK, High Pressure, 2-Position, - or 0-Port page 2
Configurations ICS-200 Series Standard Features Touch Pad Front Panel Control RFIC-EG System Eluent Generation Electrolytic Gradients Electrolytic Suppression CR-TC Trap Column Dual Piston Pump Thermostatted Digital Conductivity Cell Column Heater Chromeleon Chromatography Data System As an RFIC-EG system, just add water for these eluents: K +, Na +, or Li + hydroxide CO 3 CO 3 /HCO 3 MSA Options In-Line Vacuum Degas Eluent Regeneration (RFIC-ER) Sample Preparation Valve, PEEK, High Pressure, 2-Position, - or 0-Port Electrolytic Sample Preparation (RFIC-ESP ) Electrolytic water purifier page 3
Integrated Ion Chromato page Dionex s high-performance integrated Reagent-Free ion chromatography (RFIC ) systems, the ICS-00, ICS- 00, and ICS-200, provide the ultimate in productivity for low cost per analysis while maintaining very high sensitivity results. They combine the power of on-line sample preparation with all the capabilities of modern IC systems, including eluent generation (EG), eluent regeneration (ER), and electrolytic sample preparation (ESP). All three RFIC systems feature a dual piston pump and optional eluent degasser, a conductivity detector with heated cell, and a chromatography compartment for column, suppressor, and automated sample preparation. The ICS-200 is the first totally integrated RFIC system with Electrolytic Sample Preparation (RFIC-ESP system) for automated on-line sample preparation combined with luent generation. The ICS-00 and ICS-00 are the first integrated RFIC systems with built in ER control (RFIC-ER systems), allowing continuous operation for up to four weeks. The ICS series is compatible with all Dionex suppressor technologies and all Dionex 2 to mm columns. B A 2 3 7 8 Column: IonPac AS23 Eluent:. mm Na 2 CO 3 / 0.8 mm NaHCO 3 Flow Rate:.0 ml/min Detection: Suppressed conductivity Inj. Volume: 2 µl Manually Prepared Eluent Electrolytically Prepared Eluent 0 0 20 2 30 Peaks:. Fluoride 3.0 mg/l. Chlorate 2.0 mg/l 2. Chlorite 0.0 7. Bromide 2.0 3. Bromate 20.0 8. Nitrate 2.0. Chloride.0 9. Phosphate 0.0. Nitrite.0 0. Sulfate 30.0 229 Identical separation of anions and oxyhalides using manually or electrolytically prepared eluent. 9 0 Powerful RFIC Solutions The ICS-00 RFIC-ER system integrates an advanced set of features into a single instrument, including RFIC-ER control and plumbing for simple setup of eluent regeneration. A dual-piston pumping system with active feedback control provides extremely low pressure-ripple baselines, enabling the low flow rates required for microbore columns. Advanced detector cell design and precision temperature control provide drift-free baselines for precise integration and quantification at very low analyte concentrations. Valve options facilitate a variety of automated sample handling and preparation techniques. The ICS-00 RFIC-ER system adds an LCD touch panel display and an integrated column heater to the same set of features as those found on the ICS-00, including the powerful sample preparation capabilities. Day-to-Day Reproducibility 2 3 RFIC-EG system gradient separation, showing representative runs during a four-week time period. 7 8 0 2 8 0 2 8 20 22 2 2 28 30 Minutes Column: IonPac AG, AS, mm Eluent: 8 mm KOH from 0 min, 8- mm from 8 min Eluent Source: RFIC-EG system Flow Rate:. ml/min Inj. Volume: 2 µl Temperature: 30 C Detection: Suppressed conductivity, AutoSuppression recycle mode, 220 ma Peaks:. Fluoride 2 mg/l 2. Chloride 3. Nitrite 0. Carbonate. Sulfate 0. Bromide 20 7. Nitrate 20 8. Phosphate 30 932 The ICS-200 is the first system with integrated eluent generation (EG) and electrolytic sample preparation (ESP) capabilities. The RFIC-EG/ESP system combines electrolytic suppression and continuously regenerated trap column technology with the capability to perform a variety of automated sample preparation techniques. Electronics are available to drive auxiliary electrolytic devices, such as a water purifier for ultratrace-level anion and cation analyses. System-to-System Reproducibility C B A 2 3 0 0 20 30 Minutes Column: IonPac AG, AS mm Eluent: 8 mm KOH from 0 min, 8- mm from 8 min Eluent Source: RFIC-EG system Flow Rate:. ml/min Inj. Volume: 2 µl Temperature: 30 C Detection: Suppressed conductivity, AutoSuppression recycle mode 220 ma Peaks:. Fluoride 2 mg/l 2. Chloride 3. Nitrite 0. Carbonate -. Sulfate 0. Bromide 20 7. Nitrate 20 8. Phosphate 30 7 8 Component System A System B System C Retention Time Retention Time Retention Time (%RSD) (%RSD) (%RSD) Fluoride.37 (0.02).3 (0.03).38 (0.07) Chloride 2. (0.02) 2.3 (0.022) 2. (0.020) Nitrite 3.908 (0.022) 3.90 (0.09) 3.90 (0.02) Sulfate 7.8 (0.027) 7.23 (0.02) 7.8 (0.02) Bromide 9.382 (0.03) 9.0 (0.08) 9.38 (0.08) Nitrate 20.79 (0.03) 20.783 (0.0) 20.70 (0.07) Phosphate 22.29 (0.09) 22.089 (0.03) 22.0 (0.08) (%RSD) n=20 933 RFIC-EG systems produce consistent lab-to-lab results. The table shows excellent reproducibility when transferring applications from system to system, and laboratory to laboratory.
graphs The ICS-200 System Injector 3 Low delay volume, electrically activated PEEK Rheodyne valve provides reliability and consistency, injection to injection. Pump 2 Dual piston pump design provides low drift and pulsation-free eluent delivery, for stable baselines and lower detection limits. PEEK polymeric flow path eliminates metal contamination and corrosion. Auxiliary Power Supply The auxiliary power supply supports electrolytic sample preparation devices, such as a water purifier or CR-TC sample conditioner. Front Panel The LCD touch-pad front panel on the ICS-00 and ICS-200 provides clear identification of key operating parameters, permitting "at instrument" control and monitoring. 2 Eluent Generator 2 Eluent concentrations can be changed with the click of a mouse. Atmospheric carbonate contamination is virtually eliminated, because the eluent is not exposed to air as it is when manually preparing eluents. Eluent generation eliminates the potential variability of manually prepared eluents and enhances day-to-day, operator-to-operator repeatibility (available with the ICS-200 system). Conductivity Cell 3 Low volume, high performance thermostated cell provides high sensitivity and permits stable operation even in variable temperature environments. Digital control offers a wide dynamic range with "autoranging" that allows both major and minor components to be detected in one run. Automated Sample Prep 0 Optional -port or 0-port valve enables a wide range of sample injection and preparation techniques, such as matrix elimination, in-line filtration, and concentration. Vacuum Degas (Optional) 9 Provides in-line vacuum degassing of eluents, ensuring reproducibility and protection of eluents from contamination and decomposition. Control of the degas operation can be automated to trigger degassing as required. Eluent Valve 8 Electronically controlled valve provides positive shut-off of eluent flow prior to the pump for easy servicing. 7 9 3 3 2 8 0 Suppressor All Dionex suppressor technologies are supported, which ensures that all application requirements are met. RFIC suppressors eliminate the need to prepare acid or base regenerants, provide lower noise and better sensitivity, and require less maintenance. Column Heater Temperature control promotes column stability and reproducibility in many applications. A low-dispersion heat exchanger provides eluent pre-heating prior to the column, to maintain the column temperature set point. The transparent cover allows viewing of the column connections without temperature disruption. The column heater is standard on the ICS-00 and ICS-200 and optional on the ICS-00. USB Communication 7 Plug-n-Play USB communication permits fast connectivity and reliability. Instantaneous recognition with autoconfiguration provides ease of use and simplicity in system set up. Leak Detector and Drip Tray The built-in optical leak detector and drip tray provide fast response and shutdown for system leaks. page
A Powerful Combination of Interchangeable Modules to Support Your Applications Electrolytic Suppression The ICS-00, ICS-00, and ICS-200 support all types of Dionex suppressor technologies, including MMS, SRS, and AES suppressors. SRS and AES suppressors utilize electrolytic suppression, which frees the operator from manual regenerant preparation. The suppressor automatically produces the regenerant required for the application and provides continuous regeneration. Advantages of electrolytic suppression include the following: Enhanced day-to-day consistency with low noise and drift Reduced background conductivity and lower detection limits Fast start-up times Cation suppression for superior sensitivity Conductivity Detection The ICS-00, ICS-00, and ICS-200 have been designed and optimized for all types of IC separations and applications employing conductivity detection. The temperature- controlled high-performance conductivity cell permits measurements that are unaffected by temperature variations. Digital control offers a wide dynamic range for detecting analytes with large concentration variations within the same sample. Eluent Generation Eluent generation, integrated into the ICS-200, eliminates the need to manually prepare eluents. The system requires only a source of DI water; isocratic or gradient eluent concentrations are programmed with the click of a mouse for unprecedented simplicity and errorfree operation. Electrolytic eluent generation provides precise eluent concentration delivery, run to run, day to day, week to week, and lab to lab. 8 23 7 8 9 0 2 The RFIC-EG system consists of an eluent generator, a continuosly regenerated trap column, and an electrolytic suppressor. Electrolytically generated hydroxide eluents provide very low background conductivity, resulting in the lowest detection limits available for ion chromatography. Eluent Regeneration The ICS-00 and ICS-00 are the first fully integrated RFIC-ER systems. ER is designed for systems dedicated to routine analyses of anions or cations in low to moderate concentration matrices. ER uses the electrolytic suppressor and patented catalytic and purification columns to regenerate eluent for reuse. A single preparation of eluent can be regenerated for up to four weeks, increasing reproducibility while reducing eluent preparation time and waste disposal. Because the system operates continuously, it does not need to be reequilibrated or recalibrated between eluent preparations. The always on, always ready RFIC-ER system can be used for isocratic separations with carbonate, carbonate/bicarbonate, or methanesulfonic acid eluents. page 2-0 2 3 Component Minutes Retention Time (%RSD). Lithium 0.09 2. Sodium 0.093 3. Ammonium 0.083. Potassium 0.07. Magnesium 0.00. Calcium 0.0 0 (%RSD) n=0 93 RFIC-EG systems provide excellent reproducibility. This example uses an IonPac CS2A column running a six-cation standard, n=0. -2 0 Minutes Column: IonPac AS8, mm Eluent: 22 to 0 mm KOH: 7 8 min Eluent Source: RFIC-EG system Flow Rate: ml/min Inj. Volume: 2 µl Temperature: 30 C Detection: Suppressed conductivity, Sample: Anion standard Peaks:. Fluoride 0. mg/l 2. Acetate 2. 3. Formate.0. Chlorite. Chloride 3. Nitrite 7. Carbonate 20 8. Bromide 0 9. Sulfate 0 0. Nitrate 0. Chlorate 0 2. Phosphate 0 0 7 93 The ICS-200 and the IonPac AS8 column provide excellent separation and increased sensitivity in this anion application. RFIC-EG systems meet the requirements of U.S. EPA methods 300.0 and 300.. Peak Area Change (%) 20 0 0 - -0-20 2 2 28 Days F Cl NO 2 Br NO 3 PO SO } Pass 22 Graph of calibration check standards run over the course of 28 days using a single L bottle of eluent. The always on, always ready RFIC-ER systems remain calibrated and equilibrated when left running, saving time and labor.
Chemistry and Software Automated Sample Preparation The sample preparation capabilities available with the ICS-00, -00, and -200 systems allow a wide variety of automated laborsaving techniques: Electrolytic Sample Preparation The auxiliary power supply on the ICS-200 allows control of electrolytic sample preparation devices, such as the Self-Regenerating Neutralizers for matrix removal from acidic or basic samples. An optional electrolytic water purifier can be added to polish source water for ultratrace-level determinations. Intelligent Large Loop/Small Loop Sample Injection Automatically reinject different volumes of a sample when a specified analyte is out of range. Two injection loops with a tenfold difference in volume makes reanalysis easy. Standard 8 0 Small Loop 9 7 3 2 Large Loop Waste Waste Dual In-Line Filtration with Backflush Off-line sample filtration is costly in labor and consumables. In-line sample filtration techniques are prone to sample contamination or carryover problems. Backflushing eliminates these issues, providing more accurate results. On-Line Matrix Elimination Organic materials easily foul and damage analytical columns. Trap columns can remove these materials, but trap column lifetime is limited. Automated column wash or backflush significantly extends trap column lifetime, prevents carryover, and eliminates sample contamination. Matrix elimination can be combined with on-line filtration for further analytical column protection. Sample Preconcentration Concentrating large-volume samples enables the use of eluent regeneration for determining low analyte concentrations. It also improves chromatography by narrowing analyte bands. Optional sample preparation valves facilitate automated sample preconcentration. The optional electrolytic water purifier reduces analyte background and eliminates the need for an external pump for loading the concentrator column. Pump Water Polisher Channel Channel 2 Detector 2 Concentrator 3 CRD Suppressor Analytical Column Guard Column Chromatography Management Solutions Chromeleon Chromatography Data System Chromeleon software provides the most powerful control and data processing software available for ion chromatography. Chromeleon features make system control and setup fast and easy. Overall system and method consistency is accomplished with minimal effort with easy to follow screens and set-up wizards. Wellness Trending The built-in Electronic Log Book monitors and trends the condition of your system over time, to ensure high performance and diagnose. eworkflows Using eworkflows, the operator simply selects an instrument, specifies the number of samples and the starting vial position in the autosampler. The eworkflow automatically generates the injection list, loads the correct instrument conditions, and automatically applies the correct processing parameters. Chromatograms are immediately processed and results are instantly calculated Application Templates Simply select the column type and the Chromeleon software sets the eluent conditions and flow rate, guaranteeing system consistency and application conditions proven to meet your laboratory requirements. Calibration Wizard Simply enter the component and concentration levels through a wizard-based program. This gives the operator guidance and confirmation for fast and easy methods development and quantfication. These are just a few of the exciting features available in Chromeleon. Find out more ways Chromeleon can benefit your laboratory. Contact Dionex or point your browser to www.dionex.com. In RFIC-ESP systems, the optional water polisher also serves as a sample preparation pump, facilitating preconcentration or matrix elimination applications. page 7
Complete Customer Support Corporate Headquarters Complete Solutions Dionex is committed to providing total customer support through after-sales service, on-site training, system qualification services, and a broad range of products to meet your laboratory requirements. Customer Service With over 2 years experience in ion chromatography, Dionex understands what is necessary to install and maintain your IC systems for optimal performance and maximum up-time. We do more than install your system. We ensure it will provide solutions to your analytical problems. On-Site Training Training courses are available for all applications and levels of operator expertise. During installation, the service representative will provide an introduction and overview of system operation. Dionex also offers extended training through regional training courses or on-site courses, intended for operators new to ion chromatography. These courses are designed for the nonchemist operator and provide a how to for system configuration, instrument operation, software operation, routine maintenance, and troubleshooting. Total Commitment to Customer Satisfaction Dionex has built its reputation on problem solving and customer satisfaction. The ICS-00, ICS-00, and ICS-200 products continue that tradition. Dionex s Customer Service and Technical Support Departments can provide: System Validation IQ/OQ/PQ Custom Service Agreements Complete Instrument and Applications Support Dionex Corporation 228 Titan Way P.O. Box 303 Sunnyvale, CA 9088-303 Tel: (08) 737-0700 Fax: (08) 730-903 Worldwide Sales and Service North America U.S./Canada (87) 29-700 South America Brazil () 373 0 Europe Austria (3) 2 Benelux (3) 20 83 978 (32) 3 33 2 9 Denmark () 3 3 90 90 France (33) 39 30 0 0 Germany (9) 2 99 0 Ireland (33) 00 Italy (39) 02 2 27 Sweden () 8 73 3380 Switzerland () 2 20 99 United Kingdom () 27 9722 Asia Pacific Australia () 2 920 233 China (82) 228 3282 India (9) 22 27 273 Japan (8) 88 23 Korea (82) 2 23 280 Singapore () 289 90 Taiwan (88) 2 87 www.dionex.com Dionex products are designed, developed, and manufactured under an ISO 900 Quality System. PEEK is a trademark of Victrex PLC MMS, Reagent-Free, RFIC, RFIC-EG, RFIC-ER, and RFIC-ESP are trademarks and AES, ASRS, Atlas, AutoSuppression, Chromeleon, CSRS, IonPac, Self-Regenerating, and SRS are registered trademarks of Dionex Corporation. 2009 Dionex Corporation LPN -0 0M 02/09 Printed in U.S.A. Passion. Power. Productivity.