LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

Similar documents
LISTING INFORMATION OF Mitek Design No. MCI/WI SPEC ID: MiTek Canada, Inc. 100 Industrial Road Bradford, ON L3Z 3G7 Canada

LISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948

Stark Truss Company, Inc. Revised December 14, 2018

PinkWood Ltd. Revised September 29, 2017

Boise Cascade Company Revised June 25, 2018

Appendix D. -Weyerhaeuser Fire Rated Assembly Listings-

AUTHORIZATION TO MARK

LISTING INFORMATION OF ClarkDietrich Wall Assembly Design No. CD/WA SPEC ID: 26053

LISTING INFORMATION OF Metl-Span, LLC THERMALSAFE 8" Thick 3 Hour Fire Rated Panels SPEC ID: 29868

LISTING INFORMATION OF Metl-Span, LLC THERMALSAFE 4" Thick 1 Hour Fire Rated Wall Panels SPEC ID: 29555

LISTING INFORMATION OF Metl-Span, LLC THERMALSAFE 6" Thick 2-hour Fire Rated Panels SPEC ID: 29771

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

LISTING INFORMATION OF ClarkDietrich Steel 'H' Stud and 'U' Track Fire-resistance-rated Area Separation Wall Assemblies SPEC ID: 26662

REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: September 14, 2012 REVISED DATE: N/A

Page 2 of 5 1. Flooring Systems The flooring system shall consist of one of the following: System No. 1 Subflooring Nom 23/32 in. thick wood structura

LISTING INFORMATION OF CCI Manufacturing Inc. - HiBAR SPEC ID: CCI Manufacturing Inc Ave. Edmonton, AB T5V 1K5 Canada

LISTING INFORMATION OF SIPA - Structural Insulated Panels (SIPs) SPEC ID: Structural Insulated Panel Association (SIPA) P.O.

BXUV.L576 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY

Design No. M507. Design No. M507

Design No. U415 BXUV.U415 Fire-resistance Ratings - ANSI/UL 263. Design No. U415

REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER

Design No. L565. Design No. L565

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

UL Design System HW-D-1012 continued

Duct Wrap Flexible Wraps

FLOOR CEILING ASSEMBLY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK Order No October 15, REPORT NO CRT-002d3

BXUV.L521 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

CEYDC.R25563 Nonmetallic Plumbing System Components Listed for Fire Resistance

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

ATI Evaluation Service A Division of Architectural Testing Certification Services

BXUV.U415 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

PFC-5804* Reissued February 1, Filing Category: DESIGN Wood

LISTING INFORMATION OF Dryvit - Category 2 OUTSULATION NC EIFS Wall Systems SPEC ID: 29344

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003

Design No. L551. Design No. L551

FIRE DESIGN & INSTALLATION GUIDE

RSIC ACOUSTIC ASSEMBLY

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

ESR-1405 Reissued November 1, 2013 This report is subject to renewal December 1, 2015.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: REDBUILT LLC

RSIC ACOUSTIC ASSEMBLY

RSIC ACOUSTIC ASSEMBLY

SECTION GYPSUM BOARD PART 1 - GENERAL

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

Code Compliance Research Report CCRR-0231

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

R-Matte Plus-3: Insulation for the Building Envelope

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

SECTION GYPSUM BOARD ASSEMBLIES

FIRE DESIGN & INSTALLATION GUIDE

REPORT HOLDER: GYPSUM ASSOCIATION 962 WAYNE AVENUE, SUITE 620 SILVER SPRING, MARYLAND EVALUATION SUBJECT:

WALL ASSEMBLIES. PHILLIPS MANUFACTURING CO. - Omaha, NE USA DESIGN NO. PMC/WA DESIGN NO. PMC/WA 60-01

Installation. Resilmount A237R. Installation Instructions. Furring channel sound isolation clip

REPORT HOLDER: GYPSUM ASSOCIATION 6525 BELCREST ROAD #480 HYATTSVILLE, MARYLAND EVALUATION SUBJECT:

FOR: CEMCO - California Expanded Metal Products Co. Sound Transmission Loss Test

SECTION GYPSUM BOARD

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: APA- THE ENGINEERED WOOD ASSOCIATION

When demanding consistent quality, specify FIRM-FILL SCM-250 to assist in achieving highly improved IIC sound performance in multifamily

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

TYPICAL BEARING WALL FRAMING

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

DIVISION: CONCRETE SECTION: CEMENTITIOUS WOOD FIBER DECKS DIVISION: FINISHES SECTION: ACOUSTIC ROOM COMPONENTS

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

138 H-STUD AREA SEPARATION WALL SYSTEM

HIGH PERFORMANCE FIRE RETARDANT TREATED WOOD PRODUCTS

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

SECTION GYPSUM BOARD

The System U.S. Patent No. 5,913,788

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

ICC-ES Evaluation Report Reissued February 1, 2011 This report is subject to re-examination in one year.

Code Compliance Research Report CCRR 0232

GYPSUM BOARD AND PLASTER

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11

SECTION CEMENTITIOUS WOOD FIBER DECKS

BXUV.L548 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

CITY OF LOS ANGELES CALIFORNIA

ESR-1882 Reissued February 1, 2013 This report is subject to renewal February 1, 2014.

Report on Structural Stability of Engineered Lumber in Fire Conditions

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

Table R (1) Allowable Spans and Loads for Wood Structural Panels for Roof and Subfloor. Sheathing and Combination Subfloor Underlayment

SECTION GYPSUM BOARD ASSEMBLIES

SECTION THERMAL INSULATION

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION

INSTALLATION GUIDE GUIDE TO ASC ISO-WALL CONSTRUCTION SYSTEM APPLICATION ISO-WALL SYSTEM. ASC Iso-Wall System Includes: Materials Required:

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

FIGURE R502.2 FLOOR CONSTRUCTION

LISTING INFORMATION OF Dryvit - Category 1 OUTSULATION EIFS Wall Systems SPEC ID: 29311

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

Transcription:

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316 International Beams Inc. 2010 Boul. St-Elzear Quest Laval, QC H7L 3N4 CANADA This report is for the exclusive use of Intertek s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. International Beams Inc. 27316 Rev: Mar 27 2015 7:52AM Uncontrolled Copy Page 1 of 12

IB400, IB600, IB800 and IB900 I Joists are installed in place of conventional 2x10 and 2x12 joists using traditional framing tools and fasteners. With long lengths, I-joists are used in multiple span applications, thus reducing cutting, overlapping and material waste at the job site. The wide flanges provide a larger gluing and nailing surface for floor and roof sheathing. These lightweight joists will not twist, warp, or shrink and are more uniform in their dimensions than solid lumber. IB400, IB600, IB800 and IB900 I Joists are available in lengths up to 52 feet. IB400, IB600, IB800 and IB900 I Joists are available in depths ranging from 9-1/2 to 24 inches deep. RATINGS Standard Rating Design Number ASTM E 119 1 hour IB/WIJ 60-01 ASTM E 119 and CAN/ULC S101 45 minutes IBI/MWP 45-01 ASTM E 119 and CAN/ULC S101 1 hour IBI/MWP 60-01 ASTM E 119 and CAN/ULC S101 1 hour IBI/MWP 60-02 1 hour IBI/MWP 60-03 ASTM E 119 and CAN/ULC S101 ASTM E 119 and CAN/ULC S101 1 hour IBI/MWP 60-04 2 hours IBI/MWP 120-01 ASTM E 119 and CAN/ULC S101 Attribute Value Criteria CAN / ULC S101 (2007) Criteria ASTM E119 (2012a) CSI Code 06 17 00 Shop-Fabricated Structural Wood Fire Resistance 2 Hour Fire Resistance 1 Hour Fire Rating Fire Resistance 45 Minute Fire Rated Intertek Services Certification Listed or Inspected LISTED Listing Section PREFABRICATED JOISTS, COLUMNS & OPEN WEB TRUSSES Listing Section ROOF/CEILING, FLOOR/CEILING, BEAM & COLUMN ASSEMBLIES Report Number 3189627; 3180279; 100309568, 100559067SAT-001 EEV, 100547384SAT-002, 101819415 Spec ID 27316 International Beams Inc. 27316 Rev: Mar 27 2015 7:52AM Uncontrolled Copy Page 2 of 12

DRAWING INDEX IB/WIJ 60-01 IBI/MWP 120-01 IBI/MWP 45-01 IBI/MWP 60-01 IBI/MWP 60-02 IBI/MWP 60-03 IBI/MWP 60-04 International Beams Inc. 27316 Rev: Mar 27 2015 7:52AM Uncontrolled Copy Page 3 of 12

IB/WIJ 60-01 06 10 00 Rough Carpentry 06 17 00 Shop Fabricated Structural Wood 06 17 33 Wood I Joists Design Number IB/WIJ 60-01 Loaded Floor / Ceiling Assembly International Beams, Inc. IB600 OSB Web I Joist ASTM E119-2012 Fire Resistance Rating 1 hour Superimposed Load 51 PSF 1. TOPPING (Optional, Not Shown): Lightweight concrete, minimum density 110 pound per square foot (pcf), minimum compressive strength 3000 pound per square inch (psi) or proprietary gypsum/cement/sand topping, minimum density 100 pcf, minimum compressive strength 1000 psi. Minimum topping thickness for lightweight concrete or proprietary gypsum/cement/sand topping is 3/4 in. Date Revised: February 27, 2012 Project No: 100547384SAT-002 with joists (Item 2) spacing 24 in. on center (OC). 2. CERTIFIED COMPANY: International Beams, Inc. CERTIFIED PRODUCT: IB I Joist CERTIFIED MODEL: IB600, IB800 or IB 900 Intertek International Beams Inc. 27316 Rev: Mar 27 2015 7:52AM Uncontrolled Copy Page 4 of 12

IB/WIJ 60-01 (page 2 of 3) 06 10 00 Rough Carpentry 06 17 00 Shop Fabricated Structural Wood 06 17 33 Wood I Joists WOOD JOISTS: Use minimum 14 in., 1-1/2 in. x 2-1/2 in. flange, 3/8 in. thick OSB web I Joists spaced a maximum of 24 in. OC. Fasten I Joists to rim board with 2-3/8 in. long by 0.113 in. smooth shank nails. Fasten 1 nail through the rim board into the end of each flange, and one on each side of the joist web into the bearing plate (Not Shown). 3. SUB-FLOORING: Use nominal 23/32 in. thick tongue and groove OSB subfloor sheathing. Apply a minimum 1/8 in. bead of adhesive with the following requirements along the top of all the joists and in the flooring grooves: meets ASTM D 3498 Standard Specification for Adhesives for Field- Gluing Plywood to Lumber Framing for Floor Systems, meets American Plywood Association specifications AFG-01 and tested and approved for HUD-FHA application per specification UMB No. 60. Secure OSB using 8d 2-1/2 in. common nails spaced 6 in. OC around the perimeter and at the butted edges and 12 in. OC at interior members. 4. SOUND ISOLATION CLIP (OPTIONAL): GenieClip, UL Classified. 1-5/8 in. wide x 15/16 in. high x 2-/12 in. long spaced maximum 48 in. on centre along the length of the furring channels (Item 5). GenieClip shall be used with furring channel matching the specifications noted as required for GenieClip in Item 5 of this Design Listing. Each GenieClip must be fastened to the Wood Joist (Item 2) using a minimum 2 in. Hi-Lo drywall screw through the center grommet. 5. FURRING: Use one of the following options: i. Install 1/2 in. deep nominal 25 GA galvanized steel single leg (RC-1) or minimum 1/2 in. deep x 2-1/2 in. wide hat shaped (RC-2) channels spaced 16 in. OC and applied perpendicular to the Wood Joists (Item 2). Secure furring channels to the bottom flange of each of the Wood Joists (Item 2) using minimum 1-1/4 in. long Type W screws Date Revised: February 27, 2012 Project No: 100547384SAT-002 ensuring two screws are installed in the bottom flange of each wood joist (Item 2). When required for length, overlap the channel a minimum 6 in. and secure using a 1-1/4 in. Type W screw. ii. FOR USE WITH GENIECLIP (OPTIONAL): Install 7/8 in. deep x 2-1/2 in. face width, minimum nominal 25 GA galvanized steel spaced 16 in. OC applied perpendicular to wood joists (Item 2). Furring channels must have hemmed edges. 6. GYPSUM BOARD: Install 2 layers of 1/2 in. or 5/8 in. thick proprietary Type X gypsum board UL-Classified (Type C) for application in fire-rated construction, installed with the long edge of the base layer perpendicular to the Furring Channel (Item 4), and the face layer sheets with butt joints offset. Attach gypsum board using one of the methods below. Install 1/2 in. thick gypsum board using method i or ii, but when using 5/8 in. thick gypsum board, only method i may be used. After gypsum board is attached, apply vinyl or casein, dry or premixed joint compound to the exposed face of gypsum wallboard in two coats to all exposed fastener heads and gypsum wallboard joints. Embed a minimum 2 in. wide paper, plastic, or fiberglass tape in first layer of compound over joints in gypsum wallboard. i. Attach base layer to Furring Channel (Item 4) using 1 in. Type S drywall screws spaced 12 in. OC, 1-1/2 in. from the sides and 3/8 in. from butt joints. Attach face layer to the resilient channels (through the base layer) using 1-5/8 in. Type S drywall screws spaced 8 in. OC, 1-1/2 in. from the sides. Install face layer with joints offset 24 in. from those of the base layer in 2 directions (at the sides and ends of the panels). Attach face layer to the base layer using 1-1/2 in. Type G laminating screws spaced 8 in. OC at butt joints. Install screws just short of flush with the surface. Intertek International Beams Inc. 27316 Rev: Mar 27 2015 7:52AM Uncontrolled Copy Page 5 of 12

IB/WIJ 60-01 (page 3 of 3) 06 10 00 Rough Carpentry 06 17 00 Shop Fabricated Structural Wood 06 17 33 Wood I Joists ii. Attach base layer of gypsum board to Furring Channel (Item 4) using minimum 1-1/4 in. Type S screws spaced 12 in. OC, 1-1/2 in. from the sides and 3/8 in. from butt joints. Attach face layer to the resilient channels (through the base layer) using 1-5/8 in. Type S screws spaced 12 in. OC, 1-1/2 in. from the sides. Install face layer with joints offset 24 in. from those of the base layer in 2 directions (at the sides and ends of the panels). Attach face layer to the base layer using 1-1/2 in. Type G laminating screws spaced 12 in. OC at butt joints. Install screws just short of flush with the surface. 7. INSULATION: Use insulation with a thickness ranging from 3-1/2 in. thick (R13) to 9-1/2 in. thick (R30) unfaced glass fiber insulation batts conforming to ASTM C518. Install insulation using one of the below methods: ii. installed, insulation wire stays (Not Shown) are required and are to be spaced at a maximum of 12 in. OC perpendicular to the I-Joists in the plenum cavity. Use 6-1/4 in. thick insulation or greater. When installed, insulation wire stays are not required. Install insulation over the Furring (Item 4) and Gypsum Board (Item 5). Pressfit insulation between the bottom flanges of the Wood Joists (Item 2). Install insulation with ends butted over or between the Furring (Item 4). iii. When needed, install insulation directly underneath the sub-flooring (Item 3) and hold insulation in place using insulation wire stays installed per the manufacturer s specifications or spaced maximum 12 in. OC, whichever is more conservative. i. Use less than 6-1/4 in. thick insulation. When insulation is Date Revised: February 27, 2012 Project No: 100547384SAT-002 Intertek International Beams Inc. 27316 Rev: Mar 27 2015 7:52AM Uncontrolled Copy Page 6 of 12

IBI/MWP 120-01 International Beams Inc. June 23, 2009 Project No. 3180279COQ-004 Revised: January 27, 2015 DESIGN NO. IBI/MWP 120-01 ASSEMBLY RATING: 120 MINUTE FLOOR/CEILING ASSEMBLY 1 Floor Topping (optional): Lightweight concrete or proprietary topping. Sub-Flooring: Min. 5/8 in. thick plywood or Oriented Strand Board (OSB) installed 2 perpendicular to joists, with end joints staggered. Min. sheathing thickness (based on framing spacing) and fastener schedules shall comply with the Code. Structural Members: International Beams Inc. (IB) Series I-joists having a min. depth of 3 9-1/2 in., installed at 24 in. on center (oc) max.. Insulation (optional): When installed, insulation shall be installed above the joist flanges 4 and supported by stay wires spaced 16 in. oc. Resilient Channels: Min. 0.019 in. thick (28 GA) galvanized steel resilient channels, attached perpendicular to joists using one 1-5/8 in. long drywall screw. Resilient channels 5 spaced 16 in. oc. (channels installed after the first layer of gypsum board and is used to support the second and third layers of gypsum wallboard). 6. Gypsum Wallboard: Three layers of min. 5/8 inch thick Type C gypsum wallboard as follows: 6a. Wallboard Base Layer: Base layer of wallboard installed perpendicular to the joists and directly attached to the bottom flange using 1-5/8 in. Type S drywall screws at 12 in. oc. End joints of wallboard centered on bottom flange and staggered a min. of one joist spacing. 6b. Wallboard Middle Layer: Middle layer of wallboard attached to channels using 1 inch Type S drywall screws spaced 12 in. oc with the long dimension of wallboard 6 perpendicular to channels. Edge joints shall be centered between the joists. End joints staggered a min. of one channel spacing and offset from the edge joints in the base layer a min. of one channel spacing. 6c. Wallboard Face Layer: Face layer of wallboard attached to channels through middle layer using 1-5/8 in. Type S drywall screws spaced 8 in. oc. in the field and on the edge with a min. 3/4 in. edge distance. Edge joints of face layer of wallboard offset a distance equal to the joist spacing from those of middle layer. End joints of face layer of wallboard staggered a min. of one channel spacing with respect to the middle layer end joint. Finish System (not shown): Face layer joints covered with tape and coated with joint 7 compound. Screw heads covered with joint compound. International Beams Inc. 27316 Rev: Mar 27 2015 7:52AM Uncontrolled Copy Page 7 of 12

IBI/MWP 45-01 International Beams Inc. July 17, 2009 Project No. 3180279COQ-004 Revised: January 27, 2015 DESIGN NO. IBI/MWP 45-01 FLOOR/CEILING ASSEMBLY RATING: 45 Minutes 1 Floor Topping (optional): Lightweight concrete or proprietary topping. Sub-Flooring: Min. 5/8 in. thick plywood or Oriented Strand Board (OSB) installed 2 perpendicular to joists, with end joints staggered. Min. sheathing thickness (based on framing spacing) and fastener schedules shall comply with the Code. Structural Members: International Beams Inc. (IB) Series I-joists having a minimum depth 3 of 9-1/2 in., installed at 24 in. on center (oc) max.. 5. Resilient Channels: Min. 0.019 in. thick (28 gauge) galvanized steel resilient channel attached perpendicular to the bottom flange of the joists with one 1-5/8 inch Type W screw. 4 Channels spaced 16 inches on center max.. Additional channels are required at gypsum board end joints so that each board is attached to a separate channel. These additional channels shall extend to the next joist on each side of the board end joint. 6. Gypsum Wallboard: Min. 5/8 in. thick Type X gypsum wallboard installed with long dimension perpendicular to resilient channels and fastened to each channel with min. 1-1/8 5 in. long Type S drywall screws. Fasteners spaced 12 in. oc. in the field, 8 in. oc at wallboard end joints, and 1-1/2 in. from panel edges and ends. Edge joints shall be centered on joists. End joints of wallboard staggered a min. of one channel spacing. Insulation (optional): When installed, insulation shall be supported above the top flange 6 by stay wires spaced 16 in. oc. Finish System (not shown): Face layer joints covered with tape and coated with joint 7 compound. Screw heads covered with joint compound. International Beams Inc. 27316 Rev: Mar 27 2015 7:52AM Uncontrolled Copy Page 8 of 12

IBI/MWP 60-01 International Beams Inc. July 17, 2009 Project No. 3180279COQ-004 Revised: January 27, 2015 DESIGN NO. IBI/MWP 60-01 FLOOR/CEILING ASSEMBLY RATING: 60 Minutes 1 Floor Topping (optional): Lightweight concrete or proprietary topping. Sub-Flooring: Min. 5/8 in. thick plywood or Oriented Strand Board (OSB) installed 2 perpendicular to joists, with end joints staggered. Min. sheathing thickness (based on framing spacing) and fastener schedules shall comply with the Code. Structural Members: International Beams Inc. (IB) Series I-joists having a min. depth of 9 3 ½ inches, installed at 24 in. on center (oc) max.. (Min. 1-1/2 in. by 3-1/2 in. flange dimensions) Insulation: Min. 1-1/2 in. thick mineral wool insulation batts 2.5 pcf (min.), friction fitted 4 between the bottom flanges of the joists and supported by resilient channels. Ends of batts shall be centered over resilient channels and tightly butted. Resilient Channel: Min. 0.019 in. thick (28 GA) galvanized steel resilient channels, attached perpendicular to joists using one 1-5/8 in. long Type W screw. Resilient channels 5 spaced a max. of 16 in. oc. Additional channels are required at gypsum board end joints so that each board is attached to a separate channel. These additional channels shall extend to the next joist on each side of the board end joint. Gypsum Board: Min. 5/8 in. thick Type C gypsum wallboard installed with long dimension perpendicular to resilient channels and fastened to each channel with min. 1-1/8 in. long 6 Type S drywall screws. Fasteners spaced 12 in. oc in the field, 8 in. oc at wallboard end joints, and 1-1/2 in. from panel edges and ends. Edge joints shall be centered between joists. End joints shall be staggered one channel spacing. Finish System (not shown): Face layer joints covered with tape and coated with joint 7 compound. Screw heads covered with joint compound. International Beams Inc. 27316 Rev: Mar 27 2015 7:52AM Uncontrolled Copy Page 9 of 12

IBI/MWP 60-02 International Beams Inc. July 17, 2009 Project No. 3180279COQ-004 Revised: March 20, 2015 DESIGN NO. IBI/MWP 60-02 FLOOR/CEILING ASSEMBLY RATING: 60 Minutes 1 Floor Topping (optional): Lightweight concrete or proprietary topping. Sub-Flooring: Min. 5/8 in. thick plywood or Oriented Strand Board (OSB) installed 2 perpendicular to joists, with end joints staggered. Min. sheathing thickness (based on framing spacing) and fastener schedules shall comply with the Code. Structural Members: International Beams Inc. (IB) Series I-joists having a minimum depth of 3 9 1/2 in., installed at 24 in. on center (oc) max. Insulation (optional): When installed, insulation shall be supported by stay wires spaced 16 4 in. on center (oc). Resilient Channel (optional): Min. 0.019 in. thick (28 GA) galvanized steel resilient channel attached perpendicular to the bottom flange of the joists with one 1-5/8 in. Type W screw. 5 Channels spaced a max. of 16 in. oc. The max. channel spacing may be increased to 24 in. oc when joists are spaced a max. of 16 in. oc Gypsum Board: Two layers of min. 1/2 in. thick Type X gypsum wallboard attached with the long dimension perpendicular to the resilient channels (or joists) as follows: 6a. Wallboard Base Layer: Base layer of wallboard attached to resilient channels (or joists) using 1-1/4 in. type S drywall screws at 12 in. oc. When resilient channels are installed, edge joints shall be centered on joists. End joints of wallboard shall be centered on a resilient channel (or joist) staggered a min. of one channel (or joist) spacing. 6 6b. Wallboard Face Layer: Face layer of wallboard attached to resilient channels (or joists) through base layer using 1-5/8 in. Type S drywall screws spaced 12 in. oc in the field and 8 in. oc at the end joints. Edge joints of wallboard face layer shall be offset a min. distance equal to one joist spacing, from those of the base layer. End joints shall be offset from base layer joints by a min. of 24 in. and shall be centered in-between channel (or joist) spacing. Additionally, wallboard face layer is attached to base layer with 1-1/2 in. Type G drywall screws spaced 8 in.oc, placed 1-1/2 in. from face layer end joints. Finish System (not shown): Face layer joints covered with tape and coated with joint 7 compound. Screw heads covered with joint compound. International Beams Inc. 27316 Rev: Mar 27 2015 7:52AM Uncontrolled Copy Page 10 of 12

IBI/MWP 60-03 International Beams Inc. July 17, 2009 Project No. 3180279COQ-004 Revised: January 27, 2015 DESIGN NO. IBI/MWP 60-03 FLOOR/CEILING ASSEMBLY RATING: 60 Minutes 1 Floor Topping (optional): Lightweight concrete or proprietary topping. Sub-Flooring: Min. 5/8 in. thick plywood or Oriented Strand Board (OSB) installed 2 perpendicular to joists, with end joints staggered. Minimum sheathing thickness (based on framing spacing) and fastener schedules shall comply with the Code. Structural Members: International Beams Inc. (IB) Series I-joists having a minimum depth of 3 9-1/2 in., installed at 24 in. on center (oc) max.. Insulation: Min. 2 in. thick mineral wool insulation batts 3.5 pcf (min.), friction fitted 4 between the bottom flanges of the joists and supported by wood setting strip edges. Ends of batts shall be centered over resilient channels and tightly butted. Resilient Channel: Min. 0.019 in. thick (28 GA) galvanized steel resilient channel attached perpendicular to the bottom flange of the joists with one 1-1/8 in. drywall screw. Channels 5 spaced a max. of 16 in. oc. Additional channels are required at gypsum board end joints so that each board is attached to a separate channel. These additional channels shall extend to the next joist on each side of the board end joint. Gypsum Board: Min. 5/8 in. thick Type C gypsum wallboard installed with long dimension perpendicular to resilient channels and fastened to each channel with min. 1-1/8 in. long 6 Type S drywall screws. Fasteners spaced 7 in. oc and 1-1/2 in. from panel edges and ends. Edge joints shall be centered between joists. End joints shall be staggered one channel spacing. Wood Setting Strips (not shown): Minimum 1x4 (nominal) wood setting strips attached with 7 1-1/2 in. long Type W screws at 24 in. oc. along the bottom flange of joist creating a ledge to support insulation. Finish System (not shown): Face layer joints covered with tape and coated with joint 8 compound. Screw heads covered with joint compound. International Beams Inc. 27316 Rev: Mar 27 2015 7:52AM Uncontrolled Copy Page 11 of 12

IBI/MWP 60-04 International Beams Inc. June 23, 2009 Project No. 3180279COQ-004 Revised: January 27, 2015 DESIGN NO. IBI/MWP 60-04 ROOF/CEILING ASSEMBLY RATING: 60 Minutes 1 2 3 4 5 6 7 Roof Covering System: Insulation and roof covering materials intended for built-up covering which provides Class A, B, or C covering on combustible wood decks for fire resistant assemblies equivalent to the assembly. Sheathing: Min. 1/2 in. thick plywood or Oriented Strand Board (OSB) installed perpendicular to joists, with end joints staggered. Min. sheathing thickness (based on framing spacing) and fastener schedules shall comply with the Code. Structural Members: International Beams Inc. (IB) Series I-joists having a min. depth of 9-1/2 in., installed at 24 in. on center (oc) max.. (Min. 1-1/2 in. by 3-1/2 in. flange dimensions) Insulation: Min. 1-1/2 in. thick mineral wool insulation batts 2.5 pcf (min.), friction fitted between the bottom flanges of the joists and supported by resilient channels. Ends of batts shall be centered over resilient channels and tightly butted. Resilient Channel: Min. 0.019 in. (28 GA) thick galvanized steel resilient channels, attached perpendicular to joists using 1-5/8 in. long Type W screws. Resilient channels spaced a max. of 16 in. oc.. Additional channels are required at gypsum board end joints so that each board is attached to a separate channel. These additional channels shall extend to the next joist on each side of the board end joint. Gypsum Board: Min. 5/8 in. thick Type C gypsum wallboard installed with long dimension perpendicular to resilient channels and fastened to each channel with min. 1-1/8 in. long Type S screws. Fasteners spaced 12 in. oc in the field, 8 in. oc at wallboard end joints, and 1-1/2 in. from panel edges and ends. Edge joints shall be centered between joists. End joints shall be staggered one channel spacing. Finish System (not shown): Face layer joints covered with tape and coated with joint compound. Screw heads covered with joint compound. International Beams Inc. 27316 Rev: Mar 27 2015 7:52AM Uncontrolled Copy Page 12 of 12