ENGINEERING-CONSULTING- OPERATIONS UCC CONSTRUCTION PERMIT APPLICATION INSTRUCTIONS Dear East Union Township Construction Permit Applicant, Please complete enclosed application to obtain an East Union Township UCC Construction Permit. For your use, we have also enclosed the plan review requirements for residential and non-residential construction. Three sets of plans are required to be submitted with the completed application. Incomplete or missing application information and/or incomplete plan submittals will delay permit processing. The fees associated with these permits, made payable to East Union Township, will be calculated based on the applications submitted and are based the attached Building Permit Fee Schedule (Item C.). We will contact you with the amount of the fees due upon receipt of the plans and applications. No permits will be issued prior to receipt of all fees. If the work performed varies from the applications and/or plans and results in additional fees being required, no Occupancy Permit will be issued by East Union Township until all fees have been paid in full. Applications, plans and supporting documents for construction permits may be delivered to the East Union Township Municipal Building or forwarded directly to ARRO Consulting, Inc. An approved East Union Township Zoning Permit is required to be submitted with the construction permit application. For new construction (residential, commercial & industrial) involving the generation of sewage an approved public or on-lot sewage disposal permit is required prior to the issuance of UCC permits. The issuance of UCC Construction Permits does not individually authorize the start of construction until all other required permits and approvals are in-place. If you have any questions regarding the application process do not hesitate to contact me at 570-366- 9534. Very truly yours, ARRO Consulting, Inc. V-)-) William N. McMullen Project Manager ARRO Consulting, Inc. 400 Pinebrook Place, Suite 8 Orwigsburg, PA 17961 570-366-9534
EAST UNION TOWNSHIP UNIFORM CONSTRUCTION CODE PERMIT APPLICATION LOCATION OF PROPOSED WORK OR IMPROVEMENT Site Address: Tax Parcel # Lot # Subdivision/Land Development: Phase: Section: Owner: Phone # Fax # Mailing Address: E-Mail: Principal Contractor: Phone# Fax# Mailing Address: E-Mail Architect: Phone# Fax# Mailing Address: E-Mail: TYPE OF WORK OR IMPROVEMENT (Check One) New Building Addition Alteration Repair Demolition Relocation Sign Other Describe the proposed work: ESTIMATED COST OF CONSTRUCTION $ 1 of 3
DESCRIPTION OF BUILDING USE (Check One) RESIDENTIAL One-Family Dwelling Two-Family Dwelling NON-RESIDENTIAL Specific Use: Use Group: Change in Use: YES NO If YES, Indicate Former: Maximum Occupancy Load: Maximum Live Load: BUILDING/SITE CHARACTERISTICS Number of Residential Dwelling Units: Existing Proposed Mechanical: Indicate Type of HeatingNentilating/Air Conditioning (i.e., electric, gas, oil, etc.) Water Service: (Check) Public Private Sewer Service: (Check) Public Private (Septic Permit # ) Does or will your building contain any of the following: Fireplace(s): Number Type of Fuel Type Vent Elevator/Escalators/Lifts/Moving walks: (Check) YES NO Sprinkler System: YES NO Pressure Vessels: YES NO Refrigeration Systems: YES NO BUILDING DIMENSIONS Existing Building Area: sq. ft. Number Of Stories: Proposed Building Area: sq. ft. Height of Structure Above Grade: ft. Total Building Area: sq. ft. Area of the Largest Floor: sq. ft. FLOODPLAIN Is the site located within an identified flood hazard area? (Check One) YES NO Will any portion of the flood hazard area be developed? (Check One) YES NO N/A Owner/Agent shall verify that any proposed construction and/or development activity complies with the requirements of the National Flood Insurance Program and the Pennsylvania Flood Plain Management Act (Act 166-1978), specifically Section 60.3. Lowest Floor Level: The applicant certifies that all information on this application is correct and the work will be completed in accordance with the approved construction documents and PA Act 45 (Uniform Construction Code) and any additional approved building code requirements adopted by the Municipality. The property owner and applicant assumes the responsibility of locating all property lines, setback lines, easements, rights-of way, flood areas, etc. Issuance of a permit and approval of construction documents shall not be construed as authority to violate, cancel or set aside any provisions of the codes or ordinances of the Municipality or any other governing body. The applicant certifies he/she 2 of 3
understands all the applicable codes, ordinances and regulations. Application for a permit shall be made by the owner or lessee of the building or structure, or agent of either or by the registered design professional employed in connection with the proposed work. I certify that the code administrator or the code administrator's authorized representative shall have the authority to enter areas covered by such permit at any reasonable hour to enforce the provisions of the code(s) applicable to such permit. Signature of Owner or Authorized Agent Print Name of Owner or Authorized Agent Date (FOR CODE ADMINISTRATOR USE ONLY) PROJECT DOCUMENTS (DRAWINGS & CALCULATIONS) Type of document: Submitted Signed & Sealed Date: Revision Date: Site Plan Yes No Yes No Building Plans Yes No Yes No Electrical Plans Yes No Yes No Mechanical Plans Yes No Yes No Plumbing Plans Yes No Yes No Fire System/Detection Yes No Yes No Specifications Yes No Yes No Flood Hazard Area Data Yes No Yes No Workers Comp. Certificate Yes No ADDITIONAL PERMITS/APPROVALS REQUIRED STREET CUT/DRIVEWAY PENNDOT HIGHWAY OCCUPANCY DEP FLOODWAY OR FLOODPLAIN SEWER CONNECTION/ON-LOT SEPTIC ZONING OTHER APPROVALS BUILDING PERMIT DENIED: Date Date Returned BUILDING PERMIT : Date CODE ADMINISTRATOR Date Issued Date Expires PERMIT # PERMIT FEE $ PLAN REVIEW $ PA ACT 14 FEE $ TOTAL FEES: $ Date Paid: Check # 3 of 3
EAST UNION TOWNSHIP PLAN SUBMISSION REQUIREMENTS FOR RESIDENTIAL UCC PERMIT APPLICATIONS 1. The three (3) sets of plans and specifications must be provided along with the completed permit applications. 2. Drawings shall provide adequate information to verify conformance with the Uniform Construction Code(s). 3. Workman's Compensation Insurance Verification must be provided with East Union Township listed as the certificate holder. 4. Site plans must show building footprint and distances from lot lines, street right-of-ways and finished grades. Building Plans and/or Specifications Front, rear and side elevations (Optional) Footing/foundation diagram Garage/living area separation walls Window and Door schedule Design loads and design calculations Location of smoke and/or heat detectors "R" value of wall and ceiling insulation Plumbing Plans and/or Specifications Diagram of water supply system with fixtures and locations Diagram of sewage collection system with fixtures, location and pipe size Mechanical Plans and/or Specifications Location and equipment size Air distribution and return system Ventilation and exhaust Combustion air requirements for all new appliances Gas piping diagram Electrical & Life Safety Plans and/or Specifications Approximate location of all devices including lighting, receptacles, switches, appliances, transformers, panels, sub panels, smoke detectors, carbon monoxide detectors and if applicable sprinkler system layout and design calculations.. Homeowners are permitted to draw their own plans. All plans must be to scale. The above information represents typical details required for review of building plans for conformance to applicable codes. The Building Code Official may require additional information. THIS ABOVE LIST OF PLAN SUBMISSION REQUIREMENTS PERTAINS TO THE UNIFORM CONSTRUCTION CODE. ADDITIONAL INFORMATION MAY BE REQUIRED TO BE SUBMITTED FOR THE ISSUANCE OF OTHER PERMITS REQUIRED BY THE MUNICIPALITY. A ZONING PERMIT MUST BE OBTAINED FROM THE EAST UNION TOWNSHIP ZONING OFFICE AND A COPY OF THAT PERMIT MUST BE PROVIDED WITH THE RETURNED PERMIT APPLICATIONS AND BUILDING PLANS.
EAST UNION TOWNSHIP PLAN SUBMISSION REQUIREMENTS FOR NON-RESIDENTIAL UCC PERMIT APPLICATIONS 1. The three (3) sets of plans, drawn to scale, and specifications must be provided along with the completed permit applications. 2. All drawings shall bear the stamp and signature of the design professional responsible for the design as well as contact for the design professional. 3. Drawings shall provide adequate information to verify conformance with the Uniform Construction Code(s). 4. Workman's Compensation Insurance Verification must be provided with East Union Township listed as the certificate holder. Site Plan Site plans must show building footprint and distances from lot lines, street right-of-ways, utilities, handicap parking and access, fire lanes, north arrow, existing buildings and finished grades. Building Plans and/or Specifications Front, rear and side elevations Type of construction, use group classification, design occupant loads Separation walls, window and door schedule Design loads and design calculations Footing, foundation, framing, concrete, masonry, wood and steel construction details Plumbing Plans and/or Specifications Diagram of water supply system with fixtures and locations Diagram of sewage collection system with fixtures, location and pipe size Mechanical Plans and/or Specifications Location and equipment size Air distribution and return system Ventilation and exhaust Combustion air requirements for all new appliances Gas piping diagram Electrical/ Plans and/or Specifications Approximate location of all devices including lighting, receptacles, switches, appliances, transformers, panels and sub panels Electrical/ Plans and/or Specifications Fire system layout (Sprinklers, devices, etc.) and specifications The above information represents typical details required for review of building plans for conformance to applicable codes. Additional information may be required by the Building Code Official for review of the buildings conformance to applicable codes. THIS ABOVE LIST OF PLAN SUBMISSION REQUIREMENTS PERTAINS TO THE UNIFORM CONSTRUCTION CODE. ADDITIONAL INFORMATION MAY BE REQUIRED TO BE SUBMITTED FOR THE ISSUANCE OF OTHER PERMITS REQUIRED BY THE MUNICIPALITY. A ZONING PERMIT MUST BE OBTAINED FROM THE EAST UNION TOWNSHIP ZONING OFFICE AND A COPY OF THAT PERMIT MUST BE PROVIDED WITH THE RETURNED PERMIT APPLICATIONS AND BUILDING PLANS.
RESOLUTION No. 2013-0/ EAST UNION TOWNSHIP - UCC/ZONING PERMIT FEE SCHEDULE A. Zoning Review Certificate Residential $20.00 All other Use Groups $75.00 B. Zoning Certificate of Compliance(new buildings only) Residential (per unit) $50.00 All Other Use groups (per use) $ 225.00 C. Building Permit Fee Schedule (Requires Zoning Permit First) Residential New Construction $110.00 plus 1% of total construction cost* Plan Review $150.00 per dwelling unit Review of Revised Plans $75.00 Repairs and Renovations $25.00 plus 1% of total construction cost* Plan Review $150.00 per dwelling unit Review of Revised Plans $75.00 Demolition $150.00 per dwelling unit Utility & Miscellaneous Group U 4.5% of construction cost* Plan Review (if required) $ 75.00 All use groups other than Residential New Construction $310.00 plus 1% of total construction cost** Repairs and Renovations $55.00 plus 1% of total construction cost** Plan Review For Buildings with an estimated construction value up to $3,000,000.00 the Building Plan Review fee is: 0.0013 of the estimated value. ($250.00 Minimum) For Buildings with an estimated construction value over $3,000,000.00 up to $6,000,000.00 the Building Plan Review fee is: $3,900.00 plus 0.0005 of the estimated value over $3,000,000.00 For Buildings over $6,000,000.00 the fee is: $5,400.00 plus 0.0004 of the valuation over $6,000,000.00 The Plan Review Fee for: Electrical, Mechanical and Plumbing are computed at 25% of the Building Plan Review fee for each discipline Review of Revised Plans Demolition Signs (as required) 25% of Initial Plan Review Fee $0.01 per sq. ft. ($150.00 Minimum) $71.00 plus $2.00 per sq. ft. * All costs estimates are to be base on a minimum of $100.00/ Sq. Ft. for all use groups and $25.00/Sq. Ft. for residential accessory structures. Certified contractors estimates may be accepted. " Additional costs determined at time of review by UCC Inspector
State Act 13 Fee (All Use Groups) $4.00 Re-Inspections (For Failed Inspections All Use Groups) All re-inspections will be invoiced at a rate of $75.00/hr. plus expenses. Construction Not Covered Above Any construction, not specifically cited above, requiring a permit and inspection shall be associated with the closest specific construction type indicated. D. Commencing Activities Prior to the Issuance of Permits or Submittal of Plans Activities commenced prior to the issuance of permits or submittal of plans required by East Union Township pursuant to the Pennsylvania Uniform Construction Code shall be subject to an additional fifty percent (50%) administrative fee. EAST UNION TOWNSHIP BOARD OF SUPERVISORS Attest:,^:' / ate: e/ LS 7. Secretary)