Additional reaction to fire classification report No K

Similar documents
Classification report for roofs/roof coverings exposed to external fire No D

BIS Pacifyre AWM II, AWM III & AWM Max Manchons Coupe-Feu

BRE Global Classification Report

Title: EXTENDED APPLICATION REPORT IN ACCORDANCE WITH EN/TS Notified Body No: 0833 Product Name:

Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 Notified Body No: 0833 Product Name: Type II

Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1: Notified Body No: 0833 Product Name:

Co-ordination of the Group of Notified Bodies for the Construction Products Directive 89/106/EEC

EN Test Report

Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1: Notified Body No: 0833 Product Name:

1 st August Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1: 2009.

CLASSIFICATION OF REACTION TO FIRE FIRES-CR AUPE

Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1: Notified Body No: 0833 Product Name:

Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1: Notified Body No: Product Name:

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Contra Vision. Document Reference:

BRE Global Test Report

WFRC TEST REPORT NO BS 476: Part 7: 1997 Method For Classification Of The Surface Spread Of Flame Of Products.

Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007 Notified Body No: 0833 Product Name:

DECLARATION OF PERFORMANCE

european fire standards and national legislation

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Thermaflex International Holding B.V.

Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2002 Notified Body No: 0833 Product Name: Mix Report No:

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

BS 476: Part 6: Method Of Test For Fire Propagation For Products. WF Additional Report Number: Date: 18 th February 2008.

TECHNICAL SCHEDULE TS46 CERTIFICATION OF WOOD BASED PANELS WITH CLASSIFICATION B/C REACTION TO FIRE PERFORMANCE

EUROPEAN CONSTRUCTION PRODUCTS REGULATION INFORMATIONS ABOUT THE NEW EUROPEAN CONSTRUCTION PRODUCTS REGULATION

CrystalTM Tapis Coton

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. WF Report Number: Test Sponsor:

Review of Fire Test Report

Review of Fire Test Report

The ETA for ETICS Basics of the technical assessment of ETICS with rendering. Matthias Hammerla R&D Knauf Group

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Geaves Surface Solutions Ltd

RMANCE ROCKPANEL. System 1. inorganic finish. Konstruktieweg. Tel. Fax. Notified. Body: 1. Unique. 4. System as set. and issued: Netherlands

PRODUCT DATA SHEET. Sika Pyroplast Wood T with Topcoat Sika Pyroplast Wood Top T PRODUCT DESCRIPTION

IMO Resolution MSC 307(88): Annex 1: Part 5

COFORD 2018 WOOD TECHNOLOGY IRELAND. NO.

BRE Global Test Report

ASTM E84-05 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS

DD CEN/TS 1187: 2012 Test 4

BRE Global Test Report

Q-MARK REGISTRATION SCHEDULE FOR STRUCTURAL PLYWOOD

RESOLUTION MSC.90(71) (adopted on 21 May 1999) ADOPTION OF AMENDMENTS TO THE STANDARD FOR QUALIFYING MARINE MATERIALS FOR HIGH-SPEED CRAFT AS

DICKSON COATINGS FIRE TEST REPORT

European Technical Assessment ETA-14/0354 of

European Technical Assessment. ETA-18/0041 of Member of. General part

CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT

Report VNLF Classification Report

NRA Pavement Standards Training

REPORT NUMBER: SAT-004A ORIGINAL ISSUE DATE: April 13, 2017 REVISED DATE:

Flame-retardant treatments for timber products

Product Data Sheet Rockpanel Premium

PRODUCT DATA SHEET. Sika Pyroplast HW-300 PRODUCT DESCRIPTION. Transparent, water based fire protective coating system for wood, interior use

BS 476: Part 3: 2004 test on SureSeal EPDM 1.2mm on a plywood deck

Fire resistant toughened safety glass. Heat-reflective coating*

EPS White Book. EUMEPS Background Information on standardisation of EPS

NFP Epiradiateur Test. WF Report Number: (Issue 2) Test Sponsor: Fiba Tech Industries Limited. Date of original report:

Classification of Reaction to Fire in accordance with DIN EN :

Product Data Sheet Rockpanel Woods

DECLARATION OF PERFORMANCE

EQUITONE [pictura] Material Information Sheet

P.O. Box ZN Bleiswijk Brandpuntlaan Zuid NZ Bleiswijk The Netherlands

CERTIFICATE OF APPROVAL No. ME 5064 ALSTRONG ENTERPRISES INDIA (PVT) LTD

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Pulver Kimya San. Ve Tic. A.Ş.

DICKSON COATINGS FIRE TEST REPORT

European Technical Assessment. ETA-15/0540 of Member of. General part

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings.

RMANCE ROCKPANEL. EL FS-Xtra 9 mm. System 1. inorganic finish. Konstruktieweg. Tel. Fax. Notified. Body: 1. Unique. 4. System as set.

Determination and assessment of the continuous glowing combustion behaviour of building products in the SBI test method

European Technical Assessment. ETA-17/0398 of Member of. General part

THERMOFLOC. Peter Seppele GmbH Bahnhofstrasse 79 A 9710 Feistritz/Drau

No: UK-WER _english. 1. Unique identification code of the product-type UK-WER _english

P.O. Box ZN Bleiswijk Brandpuntlaan Zuid NZ Bleiswijk The Netherlands

Prysmian Guide to CPR

FUNDERMAX GMBH LETTER OF RESULTS

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-04 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS. We Identify and S.T.O.P. Your Noise Problem

P.O. Box ZN Bleiswijk Brandpuntlaan Zuid NZ Bleiswijk The Netherlands

Product Data Sheet Rockpanel Natural

^pr oeti. Report VNLF Classification Report

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Ronald Mark Associates Inc

Fire resistance according to EN :2008 of a Sectional door set, type Metacon OHD EI(1)-60

C Technical Data Sheet. Heat transfer Elastic Domestic wash Silver. Product Description. Product Construction. Areas of Applications

XLnt Panels. Super-size your ceiling

Product Specification

Product Data Sheet Rockpanel Brilliant

EUROPEAN ORGANISATION FOR TECHNICAL APPROVALS

Revision 1 of EN Changes and News

Product Data Sheet Rockpanel Chameleon

European Technical Assessment. ETA-11/0135 of Member of. General part

BRE Global Test Report

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-03 SURFACE BURNING CHARACTERISTICS. We Identify and S.T.O.P. Your Noise Problem.

BRE Global Test Report

Guide Specification for: FABRI TRAK PVC FREE Stretched Fabric Wall System Section [ ] or Section [ ]

File P Document DE/3 - Page 1/5

Product Guide Specification

European Technical Assessment. ETA-12/0281 of Member of. General part

Jabfloor High Performance (HP) 70 and 100

CLASSIFICATION OF REACTION TO FIRE FIRES-CR AUPE

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-03 SURFACE BURNING CHARACTERISTICS. We Identify and S.T.O.P. Your Noise Problems

Report VNLF Classification Report

European Technical Assessment ETA-10/0067 of

PROPOSAL BALLOT DUE BY: Wednesday, September 2, 2009

Transcription:

Additional reaction to fire classification report. 16736K Owner of the additional classification report Rokerijweg 5 1271 AH Huizen The Netherlands Introduction This additional classification report defines the classification assigned to the product BN CONTRACT WALLCOVERING - HT NONWOVEN FABRIC BACKED in accordance with the procedures given in the standard EN 13501-1:2007+A1:2009: Fire classification of construction products and building elements - Part 1: classification using data from reaction to fire tests. This additional classification report consists of 8 pages This report is additional to that issued as. 16736F, dated 03/02/2015. This report is drafted in accordance with the regulations of EGOLF Agreement EGA 08rev2:2013 Application note: clause 5.10 / 4-2 Amendment of reports: client changing product/company names (ii) for commercial reasons Issue of additional reports. The original report remains valid and is not replaced by this report. The product has not been retested and this report does not involve technical changes or technical reviews of the original report. The original and the new name of the product and of the company commercially responsible for the product, as well as the declarations concerning this additional report, are documented by the laboratory and maintained in the laboratory records. FOUNDING MEMBER WFRGENT nv - Ottergemsesteenweg-Zuid 711 - B-9000 Gent - België t: +32 9 243 77 50 - f: +32 9 243 77 51 - e: info@wfrgent.com BTW/VAT/TVA: BE0870.418.414 - Ondernemingsnummer: RPR GENT 0870.418.414 NOTIFICATIE BPV-RPC 1173 196-TEST WFRGENT nv is een spin-offbedrijf van de Universiteit Gent, voorheen Laboratorium voor Aanwending der Brandstoffen en Warmteoverdracht - Afdeling Brandveiligheid WFRGENT nv is a spin-off company from the University of Ghent, previously the Laboratory for Heat Transfer and Fuel Technology - Fire Safety Division

Page 2 of 8 1. DETAILS OF CLASSIFIED PRODUCT a) Nature and end use application The product BN CONTRACT FABRIC BACKED is defined as a decorative wall covering'. Its classification is valid for the following end use application(s): Used for attaching onto walls or ceilings by means of an adhesive. b) Description of the tested product This description is based on information given by the sponsor. minal values BN CONTRACT FABRIC BACKED The tested product is wall covering consisting of a Type of product non-woven fabric backing coated with a polyvinyl chloride (PVC) layer with or without ink (non solvent based) and with an acrylic top coating. Manufacturer Total thickness (mm) (1) Total surface mass (g/m²) 355 ± 45 n-woven fabric backing Type of product n-woven fabric backing Manufacturer (2) Thickness (mm) 0,19 ± 0,03 Surface mass (g/m²) 90 Use of fire retardants Coating: PVC layer Type of product The product consists of a PVC layer with or without ink (non solvent based) and with an acrylic top coating. Manufacturer Thickness (mm) (1) Surface mass (g/m²) 270 Use of fire retardants Colour White (code 00842), red (code 05010) and dark brown (code 03602). (1) The sponsor has declared that the thickness depends on the grade of embossing. (2) t communicated by the sponsor.

Page 3 of 8 Mounting and fixing Substrate Type of product Calcium silicate board Thickness (mm) 12 Density (kg/m³) 870 Fixation of the wall covering Application method The product BN CONTRACT WALLCOVERING - HT NONWOVEN FABRIC BACKED was glued onto the substrate. Type of glue Heavy duty wall covering adhesive BK 10 Amount of glue (g/m²) 250 ± 50 Test specifications: EN 13823 The product was tested with a closed vertical joint at 200 mm from the inner corner. Test specifications: EN ISO 11925-2 The product was tested freehanging. 2. TEST REPORTS AND TEST RESULTS IN SUPPORT OF THIS CLASSIFICATION a) Test reports Name of the laboratory Name of the sponsor Test report ref.. Test method WFRGENT nv Ghent, Belgium Huizen, The Netherlands 16736B, 16736C EN ISO 11925-2 (vember 2010/AC:2011) WFRGENT nv Ghent, Belgium Huizen, The Netherlands 16736D, 16736E EN 13823 (July 2010+A1:2014) WFRGENT nv Ghent, Belgium Huizen, The Netherlands 16736G EXAP according to CEN/TS 15117 (August 2005)

Page 4 of 8 b) Test results Test method EN ISO 11925-2 (*) (1) 30 s flame application: Parameter Surface exposure Fs 150 mm - front side Ignition filter paper Edge exposure - front side Fs 150 mm Ignition filter paper EN 13823 (2) FIGRA 0,2 MJ (W/s) FIGRA 0,4 MJ (W/s) LFS<edge THR600s (MJ) SMOGRA (m²/s²) TSP600s (m²) Flaming droplets/particles f < 10 s f > 10 s Number of tests Continuous parameters Mean 6 6 3 76 12 1,4 1 (**) 46 (**) Results Compliance parameters Criteria for Class B-s1,d0 Continuous parameters 120 7,5 30 50 Compliance parameters t applicable. (*) The material didn t melt nor pull away from the pilot burner. (**) Smoke value was corrected according to A.6.1.2 of EN 13823:2010 te (p.34). (1) Based on the results obtained in test report. 16736C BN CONTRACT WALLCOVERING - HT NONWOVEN FABRIC BACKED (Red). (2) Based on the results obtained in test report. 16736E BN CONTRACT WALLCOVERING - HT NONWOVEN FABRIC BACKED (Red). Fs 150mm Ignition filter paper Average maximal flame spread (mm) Sample 1: BN CONTRACT 29,2 FABRIC BACKED (white) Sample 2: BN CONTRACT 37,5 FABRIC BACKED (red) Sample 3: BN CONTRACT FABRIC BACKED (dark brown) 36,7 Based on the results obtained in test report. 16736B: only edge exposure was performed.

Page 5 of 8 Sample 1a: BN CONTRACT FABRIC BACKED (white) Sample 1b: BN CONTRACT FABRIC BACKED (white) Average sample 1: BN CONTRACT FABRIC BACKED (white) Sample 2a: BN CONTRACT FABRIC BACKED (red) Sample 2b: BN CONTRACT FABRIC BACKED (red) Average sample 2: BN CONTRACT FABRIC BACKED (red) Sample 3a: BN CONTRACT FABRIC BACKED (dark brown) Sample 3b: BN CONTRACT FABRIC BACKED (dark brown) Average sample 3: BN CONTRACT FABRIC BACKED (dark brown) FIGRA (W/s) THR600S (MJ) SMOGRA (m²/s²) TSP600S (m²) 65 1,5 9 77 58 1,5 10 74 62 1,5 10 76 63 1,4 8 61 101 1,6 9 63 82 1,5 9 62 76 1,3 11 69 77 1,3 8 58 77 1,3 9 64 Based on the results obtained in test report. 16736D: Two tests on each product have been carried out instead of the standard three replicates.

Page 6 of 8 3. CLASSIFICATION AND DIRECT FIELD OF APPLICATION a) Reference and direct field of application This classification has been carried out in accordance with EN 13501-1:2007+A1:2009 and EN 15102:2007+A1:2011. b) Classification The product BN CONTRACT FABRIC BACKED in relation to its reaction to fire behavior is classified as: Fire behavior Smoke production Flaming droplets B s1 d0 c) Field of application This classification for the product as described in 1b, is valid for the following end use conditions: Substrate: Euroclass A2-s1,d0 or better with a nominal thickness of at least 9 mm and a nominal density of at least 652,5 kg/m³. Fixing: Directly glued (250 ± 50 g/m²) onto the substrate using heavy duty wall covering adhesive BK 10 or similar PVA substitute for absorbing surfaces. With or without vertical closed joints. This classification is valid for the following product parameters: Total product: BN CONTRACT WALLCOVERING - HT NONWOVEN FABRIC BACKED n-woven fabric backing Coating Total thickness Embossing Total surface mass minal thickness 0,19 ± 0,03 minal surface mass 90 g/m² Use of fire retardants minal thickness minal surface mass Use of fire retardants Colour Depends on the embossing Regularly spread over the entire surface (355 ± 45) g/m² Depends on the embossing 270 g/m² All colours

Page 7 of 8 4. RESTRICTIONS At the time the standard EN 13501-1:2007+A1:2009 was published, no decision was made concerning the duration of validity of a classification report. 5. WARNING This classification report does not represent type approval nor certification of the product. The classification assigned to the product in this report is appropriate to a Declaration of Performance (DoP) of the essential characteristics of the construction product by the manufacturer within the context of a System 3 Assessment and Verification of Constancy of Performance (AVCP). Under the Construction Products Regulation (CPR: EU 305/2011), such a Declaration of Performance (DoP) is a requirement for affixing the CE marking. The manufacturer has made a declaration, which is held on file. This confirms that the product's design requires no specific processes, procedures or stages (e.g. no addition of flame-retardants, limitation of organic content, or addition of fìllers) that are aimed at enhancing the fire performance in order to obtain the classification achieved. As a consequence the manufacturer has concluded that a System 3 Assessment and Verification of Constancy of Performance (AVCP) is appropriate. The test laboratory has played no part in sampling the product for the test, although it holds appropriate references, supplied by the manufacturer, to provide evidence for the traceability of the samples tested. EN 13501-1:2007+A1:2009: Annex B Reaction to fire classification report 5 Limitations: The classification assigned to the product in this report is appropriate to a Declaration of Conformity by the manufacturer within the context of a System 3 Attestation of Conformity and CE marking under the Construction Products Directive. The manufacturer has made a declaration, which is held on file. This confirms that the product s design requires no specific processes, procedures or stages (e.g. no addition of flame-retardants, limitation of organic content, or addition of fillers) that are aimed at enhancing the fire performance in order to obtain the classification achieved. As a consequence the manufacturer has concluded that system 3 attestation is appropriate.

Page 8 of 8 The test laboratory has, therefore, played no part in sampling the product for the test, although it holds appropriate references, supplied by the manufacturer, to provide for traceability of the samples tested. PREPARED BY APPROVED BY Signature 1 Signature 2 This document is the original version of this additional classification report and is written in English. This report may be used only literally and completely for publications. - For publications of certain texts, in which this report is mentioned, our permission must be obtained in advance. The authenticity of the electronic signatures is assured by Belgium Root CA.