AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A AAMA TEST REPORT SUMMARY

Similar documents
AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT SUMMARY. Rendered to:

TEST REPORT. Report No.: B Rendered to: MI WINDOWS AND DOORS, INC. Gratz, Pennsylvania

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: ALUMIL US. SERIES/MODEL: M300 Falcon PRODUCT TYPE: Aluminum Horizontal Sliding Window (XO)

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window

TEST REPORT. Rendered to: EARTHWISE GROUP, LLC Liberty Township, Ohio

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

TEST REPORT. Report No.: A Rendered to: DEALERS SUPPLY AND LUMBER CO., LLC Greenville, South Carolina

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

Structural Performance Certification Authorization Report

INTERNATIONAL WINDOW TEST REPORT

Architectural Testing TEST REPORT. Rendered to: COEUR D'ALENE WINDOW Spokane Valley, Washington. PRODUCT TYPE: PVC Fixed Window SERIES/MODEL: 3310

TEST REPORT AAMA/WDMA/CSA 101/I.S.2/A440-11

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

TEST REPORT. Report No.: F Rendered to: MI WINDOWS AND DOORS, LLC Gratz, Pennsylvania

Structural Performance Certification Authorization Report

Dennis Fassnacht Jr :59:35-04'00'

TEST REPORT. ASSOCIATED MATERIALS, INCORPORATED Cuyahoga Falls, Ohio. Rendered to: PRODUCT TYPE: Fixed Window SERIES/MODEL: A780 SPECIFICATIONS:

Structural Performance Certification Authorization Report

TEST REPORT AAMA/WDMA/CSA 101/I.S.2/A440-11

Structural Performance Certification Authorization Report

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: BUILDERS ACCESSORIES, INC.

TEST REPORT. Report No.: A Rendered to: TUBELITE, INC. Walker, Michigan

OSHA Title 8 General Industry Safety Orders Floor Openings, Floor Holes, Skylights and Roofs

ANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

ETC Laboratories Measuring Up To Your Standards And More

Construction Consulting Laboratory, International

AAMA 506 TEST REPORT. Report No.: G Rendered to: VEKA INC. Fombell, Pennsylvania

TEST REPORT. Report No.: G Rendered to: CR LAURENCE CO., INC. Vernon, California

AAMA/WDMA/CSA 101/I.S.2/A440-08

PERFORMANCE TEST REPORT. Report No.: H Rendered to: VELUX America LLC Greenwood, South Carolina

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: MGM WINDOW COMPANY Hendersonville, Tennessee

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: WASHOE EQUIPMENT, INC. DBA SUNOPTICS PRISMATIC SKYLIGHTS

SECTION VINYL (PVC) WINDOWS

STRUCTURAL PERFORMANCE TEST REPORT. Series Casement (Rep/Impact/AAMA) C-C70 940mm x 1930mm (37 x 76 )

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

AAMA/WDMA/CSA 101/I.S.2/A440-08

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.

MOCK-UP TEST REPORT NCTL ACURLITE STRUCTURAL SKYLIGHTS MOCKUP TEST UNIT TEST DATES 03/13/17, 03/21/17 03/23/17 REPORT DATE 04/03/17

TEST REPORT. Report No.: F Rendered to: FAIRFIELD METAL, LLC Fairfield, New Jersey


SECTION SERIES 200 DOUBLE-HUNG VINYL WINDOWS

OSHA FALL PROTECTION TEST REPORT. Rendered to: VELUX America Inc. SERIES/MODEL: VCM/VCE B PRODUCT TYPE: Venting Curb Mounted Skylight

PERFORMANCE TEST REPORT. Rendered to: TREMCO INC. SERIES/MODEL: Proglaze ETA - System 3 PRODUCT TYPE: Pre-Engineered Air Barrier Transition Assembly

SECTION ALL ULTREX DOUBLE HUNG WINDOW

Intertek NAFS-11 Testing

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: LEED HIMMEL INDUSTRIES, INC. Hamden, Connecticut

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Rendered to: FLEETWOOD WINDOWS & DOORS. SERIES/MODEL: Norwood 3070HI OOX PRODUCT TYPE: Sliding Glass Door

United Window & Door - Series 5500 New Construction Double Hung Windows Specifications

SECTION ALUMINUM WINDOWS

MOCK-UP TEST REPORT. Report No: NCTL Test Dates:06/22, 07/23-27/10 Test Dates: 08/23-25/10 Report Date: 08/26/10

Sliding Patio Doors Brickmould Vinyl

SIDE HINGED SECURITY ALUMINUM WINDOWS

AAMA 1801 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, INC. SERIES/MODEL: 420/430/440. TYPE: Sliding Glass Door

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

4 1 2" Sliding Door WINDOW ELEVATIONS FEATURES OPTIONAL O-X SLIDING DOOR X-O SLIDING DOOR VER:

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: COASTAL INNOVATIVE PRODUCTS

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

4600 Series Specifications (Section 08520)

SECTION K. Section Millwork: Wood trim other than furnished by door and frame manufacturer

SILVER LINE BUILDING PRODUCTS

Series 4900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

SECTION ALUMINUM WINDOWS

General Specifications COMPLETE PRODUCT LINE

SECTION SLIDING PATIO DOORS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text

SERIES /8 SINGLE HUNG (CW50)

PRODUCT SPECIFICATION SERIES 4500T THERMALLY BROKEN ALUMINUM SLIDING BALCONY DOOR

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS

TEST REPORT. Report No.: B Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

TEST REPORT. Report No.: F Rendered to: VELUX America LLC Greenwood, South Carolina

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window

Awning Windows Tuscany Vinyl Replacement Window

AAMAIWDMAlCSA S.2/ A "NAFS - North American Fenestration Standard/Specification for Windows, Doors and Skylights."

OSHA FALL PROTECTION TEST REPORT. Rendered to: SERIES/MODEL: FS S PRODUCT TYPE: Fixed Deck Mounted Skylight

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

SERIES 8510 AW-PG85-FW FIXED WINDOW

Awning Windows Montecito New Construction Window

Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

Casement Windows Montecito New Construction Window

SECTION FIBERGLASS CLAD EXTERIOR / WOOD INTERIOR FULL FRAME DOUBLE-HUNG WINDOWS CSI PRODUCT SPECIFICATION

Casement Windows Tuscany Vinyl Replacement Window

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

SERIES /8 HORIZONTAL SLIDING WINDOW (CW30)

SERIES 2100 CW-PG60-FW FIXED WINDOW

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

Milgard Double Bypass Horizontal Sliding Windows SERIES QUIET LINE VINYL JANUARY Min Max

SECTION VINYL WINDOWS AND DOORS. 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes)

DOUBLE HUNG SERIES 3500 AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.

SERIES 6200 HS-HC60 HORIZONTAL SLIDING WINDOW

SECTION FIBERGLASS CLAD EXTERIOR / WOOD INTERIOR INSERT DOUBLE-HUNG WINDOWS CSI PRODUCT SPECIFICATION

Transcription:

AAMA/WDMA/CSA 101/I.S.2/A440-08 AAMA/WDMA/CSA 101/I.S.2/A440-05 AAMA 910-93 TEST REPORT SUMMARY Rendered to: GIESSE NORTH AMERICA 2014 Holston Industrial Drive Blountville, TN 37617 PRODUCT TYPE: XO Sliding Glass Door SERIES/ MODEL: GOS-S Lift and Slide Door Title Primary Product Designator AAMA/WDMA/CSA 101/I.S.2/A440-08 AAMA/WDMA/CSA 101/I.S.2/A440-05 Positive Design Pressure Negative Design Pressure Operating Force (in motion max ) Air Infiltration Water Penetration Resistance Test Pressure Uniform Load Structural Test Pressure Forced Entry Resistance AAMA 910-93 Summary of Results Class AW-PG50: Size tested 3124 x 2416 mm (123 x 95.125 in) - SD SD-AW50 3124 x 2416 (123 x 95.125) +2400 Pa (+50.0 psf) -2400 Pa (-50.0 psf) 35.6 N (8 lbf) Prior to and After cycling 0.1 L/s/m 2 (0.01 cfm/ft 2 ) Prior to and After cycling 730 Pa (15.0 psf) ±3600 Pa (75.0 psf) ASTM F842-04 - Grade 10 Pass Pass Test Completed: 08/08/13 Revision Date: 09/17/13 Reference must be made to Report No. NCTL-110-16304-1 dated 09/05/13 for complete test specimen description and data. For National Certified Testing Laboratories Jay Leader Technician 1 of 23

AAMA/WDMA/CSA 101/I.S.2/A440-08 AAMA/WDMA/CSA 101/I.S.2/A440-05 AAMA 910-93 STRUCTURAL TEST REPORT NCTL-110-16304-1 REPORT TO: GIESSE NORTH AMERICA 2014 HOLSTON INDUSTRIAL DRIVE BLOUNTVILLE, TN 37617 REPORT NUMBER: NCTL-110-16304-1 REPORT DATE: 09/05/13 REVISION DATE: 09/17/13 PRODUCT: GOS-S LIFT AND SLIDE DOOR TYPE XO SLIDING GLASS DOOR 2 of 23

Report Number NCTL-110-16304-1 Report Date 09/05/13 Revision Date 09/17/13 Report To Giesse North America 2014 Holston Industrial Drive Blountville, TN 37617 Test Date 08/08/13 Specification Performance Results AAMA/WDMA/CSA 101/I.S.2/A440-08 NAFS North American Fenestration Standard/Specification for windows, doors, and skylights AAMA/WDMA/CSA 101/I.S.2/A440-05 Standard/Specification for Windows, Doors, and Unit Skylights AAMA 910-93 Voluntary Life Cycle Specifications and Test Methods for Architectural Grade Windows and Sliding Glass Doors AAMA/WDMA/CSA 101/I.S.2/A440-08 Class AW-PG50: Size tested 3124 x 2416 mm (123 x 95.125 in) - SD AAMA/WDMA/CSA 101/I.S.2/A440-05 SD-AW50 3124 x 2416 (123 x 95.125) Description of Specimen Tested Note: All dimensions are in the order (Width x Height x Thickness) unless otherwise noted. Model/ Series GOS-S Lift and Slide Door Configuration OX Sliding Glass Door Overall Frame Size 23.616 mm x 2416.18 mm (123 x 95.125 ) Active Panel Size 1565.28 mm x 2330.45 mm (61.625 x 91.75 ) Fixed Panel Size 1565.28 mm x 2330.45 mm (61.625 x 91.75 ) Viewing Area 1397 mm x 2171.9 mm (55 x 85.5 ) Frame & Panel Joint Construction Glazing Components Overall Glass Thickness Spacer /Size Glazing System Extruded aluminum with reinforced nylon thermal breaks Frame (1) Screw, mitered, aluminum corner gusset Panel Mitered, slide-fitted double aluminum corner keys 23.14 mm (0.911 ) Nominal (2) Lites of 6 mm (0.222 ) nominal tempered glass 11.86 mm (0.467 ) Aluminum desiccant-filled spacer ( A1-D) Interior glazed with interior, exterior glazing gaskets and a silicone heel bead 3 of 23

Giesse North America NCTL-110-16304-1 Weatherstrip (2) Strips bulb-vinyl Jamb stiles, top and bottom rails (1) Strip bulb-vinyl Meeting stiles (1) Strip center fin Size 6.35 mm (0.250 ) Meeting stiles Operating Hardware Locks Keeper Auxiliary Reinforcement Single-handle (3)-point integrated lock system 996.95 mm (39.25 ) From the bottom of the active lock stile (2)-Point integrated lock system Fixed jamb stile Metal Active and fixed lock jambs at the lock location Rigid vinyl weatherstrip adapter/ interlock Meeting stiles secured with evenly spaced screws Rigid vinyl filler Head and jambs Rigid vinyl track cover with roller guide Interior and exterior sill tracks Plastic end-cap with felt-wrapped foam Each end of the fixed meeting stile Plastic end-cap Each end of the active meeting stile Metal adjustable dual tandem rollers with metal housing 241.3 mm (9.5 ) From each end of the active bottom rail Aluminum retainer Exterior of the head and interior of the sill secured with evenly spaced screws Plastic end cap Each end of the head and sill retainer Plastic block Each end of the top rails Rubber bumper Each end of the jamb stiles Aluminum cover Meeting stiles and interior head face (2) Aluminum interlock clips Midspan of each meeting stile, each clip was secured with (3) screws Plastic head adapter with felt-wrapped foam Midspan of the head secured with (4) screws No reinforcement employed 4 of 23

Giesse North America NCTL-110-16304-1 Weep Description Custom weep assembly box with felt-wrapped foam secured with (4) screws Midspan of the sill Interior/ Exterior Surface Finish Sealant Material Insect Screen Installation Method Silver painted aluminum Frame and panel corners Silicone No screen employed The door was installed in a 50.8 mm x 304.8 mm (2 x 12 ) wood buck and was encased with steel. The door was secured to the buck with (1) #8 x 69.85 mm (2.75 ) flat head screw. At the active jamb, interior track screws were located at 152.4 mm (6 ) from each end and 304.8 mm (12 ) on center thereafter. At the fixed jamb, exterior track screws were located at 152.4 mm (6 ) from each end and 304.8 mm m (12 ) on center thereafter. From the active jamb, screws were located at 152.4 mm (6 ) from the end and 304.8 mm (12 ) on center thereafter at the interior head track to the head midspan. From the fixed jamb, screws were located at 152.4 mm (6 ) from the end and 304.8 mm (12 ) on center thereafter at the exterior head track to the head midspan. The sill was pressure-fitted over (6) evenly spaced aluminum plates. Each plate was secured to the buck with (2) #8 x 38.1 mm (1.5 ) flat head screws. The sill was bedded in silicone and the exterior perimeter was sealed with silicone. Test Results - AAMA/WDMA/CSA 101/I.S.2/A440-2008 & 2005 Paragraph Test 5.2 Operating Force and Force to Latch - Method B (Force Gauge) ASTM E2068-00(08) Prior to and After cycling Initiate Motion = 62 N (14 lbf) Allowed (AW Rating 05/08 ) = 178 N (40 lbf) Maintain Motion - Opening = <27 N (<6 lbf) Maintain Motion - Closing = 36 N (8 lbf) Allowed (AW Rating 05/08 ) = 111 N (25 lbf) Latches = 31 N (7 lbf) Allowed = 100 N (22.5 lbf) NOTE: The results above represent the maximum force among all sash tested. Paragraph Test 5.3.2.1 Air Leakage Resistance ASTM E283-04(12) The tested specimen meets or exceeds the performance levels specified in AAMA/WDMA/CSA 101/I.S.2/A440-2008 and 2005 for air infiltration at 300 Pa (6.2 psf). Prior to and After cycling Maximum Allowable = 1.5 L/s/m 2 (0.3 cfm/ft 2 ) Extraneous Air Leakage Total Air Leakage = 9.86 L/s (20.9 cfm) = 10.43 L/s (22.1 cfm) 5 of 23

Giesse North America NCTL-110-16304-1 Air Infiltration Rate = 0.1 L/s/m 2 (0.01 cfm/ft 2 ) Paragraph Test 5.3.3 Water Penetration Resistance ASTM E547-00(09) and ASTM E331-00(09) Prior to and After Cycling No Leakage after 4 cycles of 5 minutes at 730 Pa (15.0 psf) No Leakage after 1 cycle of 15 minutes at 730 Pa (15.0 psf) NOTE: Tested without insect screen Paragraph Test 5.3.4.2 Uniform Load Deflection at Design Pressure ASTM E330-02(10) No damage after positive No damage after negative 2880 Pa (60.0 psf) held for 10 seconds 2880 Pa (60.0 psf) held for 10 seconds Measured Deflection Positive = 11.28 mm (0.444 inches) Measured Deflection Negative = 7.47 mm (0.294 inches) Maximum Allowed (L/175 AW) = 13.39 mm (0.527 inches) Paragraph Test 5.3.4.3 Uniform Load Structural Test ASTM E330-02(10) No damage after positive No damage after negative 3600 Pa (75.0 psf) held for 10 seconds 3600 Pa (75.0 psf) held for 10 seconds Measured Permanent Set Positive = 0.71 mm (0.028 inches) Measured Permanent Set Negative = 0.41 mm (0.016 inches) Maximum Allowed (0.2%) = 4.70 mm (0.185 inches) NOTE: Deflection and Permanent Set measurements taken on the meeting stile over a 2343.15 mm (92.25 ) span. Paragraph Test 5.3.5 Forced Entry Resistance ASTM F842-13 A SGD Assembly/Grade 10: = Pass Test Results Allowed Hardware Manipulation Test No Entry No Entry Test A1 No Entry No Entry Test A2 No Entry No Entry Test A3 No Entry No Entry Test A4 No Entry No Entry Test A5 No Entry No Entry Test A6 No Entry No Entry Hardware Manipulation Test No Entry No Entry D SGD Assembly/Grade 10: = Pass Test Results Allowed Test D1 No Entry No Entry Test D2 No Entry No Entry Test D3 No Entry No Entry Hardware Manipulation Test No Entry No Entry 6 of 23

Giesse North America NCTL-110-16304-1 NOTE: 1. T1 = 5 minutes, L1 = 1334 N (300 lbf), L2 = 778 N (175 lbf), L3 = 133 N (30 lbf), L4 = 222 N (50 lbf) plus weight of panel. 2. Loads were held for 60 seconds. Paragraph Test 5.3.6.2 Thermoplastic Corner Weld Test (PVC products only) - Pass Paragraph Test 5.3.6.3 Deglazing Test ASTM E987-88(09) Active Panel Stiles 320 N (70.0 lbf) Results Allowed Jamb Stile 22.4% <90% (<100%) Meeting Stile 23.6% <90% (<100%) Rails 230 N (50.0 lbf) Results Allowed Top Rail 14.8% <90% (<100%) Bottom Rail 15.8% <90% (<100%) NOTE: The glass bite was approximately 12.7 mm (0.5 ) This test report was prepared by National Certified Testing Laboratory (NCTL), for the exclusive use of the above named client and it does not constitute certification of this product. The results are for the particular specimen tested and do not imply the quality of similar or identical products manufactured or installed from specifications identical to the tested product. The test specimen was supplied to NCTL by the above named client. No conclusions of any kind regarding the adequacy or inadequacy of the glass in the test specimen are to be drawn from the ASTM E330-02(10) test. Forced entry resistance test equipment used is in compliance with Section 7 of ASTM F842-13 test method. Foam tape is mounted to the perimeter of the test buck prior to clamping to the test wall. NCTL is a testing lab and assumes that all information provided by the client is accurate and does not guarantee or warranty any product tested or installed. The results in this report are actual tested values and are applicable to the specimen tested only, using the components and construction methods described herein. 7 of 23

Giesse North America NCTL-110-16304-1 Detailed drawings were available for laboratory records and compared to the test specimen at the time of this report. Component drawings were reviewed for product verification. The bill of materials contains details with any deviations noted. Ambient conditions during the referenced testing are available upon request. A copy of this report along with representative sections of the test specimen will be retained by NCTL. This report does not constitute certification or approval of the product, which may only be granted by a certification program validator or recognized approval entity. All tests were conducted in full compliance with the referenced specifications and/or test methods. This report is the joint property of National Certified Testing Laboratories Inc. and the Client to whom it is issued. Permission to reproduce this report by anyone other than National Certified Testing Laboratories Inc and the Client must be granted in writing by both of the above parties. This report may not be reproduced, except its entirety, without the written consent of NCTL. National Certified Testing Laboratories Jay Leader Technician Robert H. Zeiders, P.E. Vice-President Engineering & Quality NJL/ hl Attachments Appendix A Revision Summary Appendix B Drawings 8 of 23

Appendix A Section 1: Component Drawings, with Applicable Part Numbers, Manufacturing and Modeling Details, were Reviewed (as submitted) for Product Verification (Reference: NCTL-110-16304-1) See Attached Documentation; any deviations noted. Note: The above referenced component drawings (if applicable) along with representative sections of the test specimen will be retained per procedure by NCTL. This testing facility assumes that all information provided by the client is accurate. Section 2: Identification Date Page & Revision Original Issue 09/05/13 Not Applicable Revision 01 09/17/13 Replaced drawings at client request 9 of 23

Appendix B Drawings 10 of 23

11 of 23

12 of 23

13 of 23

14 of 23

15 of 23

16 of 23

17 of 23

18 of 23

19 of 23

20 of 23

21 of 23

22 of 23

23 of 23