Status of Chlorate Regulations & Impact at Water Treatment Plants

Similar documents
On-Site Generation Of Disinfectants

Distribution System Levels of Chlorate From Formation in Sodium Hypochlorite Stock

Electrochemical Generation The applications and scientific mechanisms of disinfectants generated on-site using salt, water and electricity

Conditions for Making Sodium Hypochlorite (Bleach) for Water Treatment in a Developing Country While Avoiding Inorganic Disinfection By-Products

On-Site Sodium Hypochlorite Generation Equipment

CHEMNIUM NACLO SODIUM HYPOCHLORITE GENERATOR

The ABC s of OSG (On-Site Generation of Hypochlorite and Chlorine Gas) TACWA Business Meeting Fort Worth, Texas

Chloramine: An Effective Biocide for Produced Waters. Andrew K. Boal, Ph.D. and Charles Mowery

Making Bleach Made Easy

NJWA Presents DISINFECTION BYPRODUCTS: TREATMENT OPTIONS & CHALLENGES. Stage 2 D/DBPR. Trihalomethanes DISINFECTION BYPRODUCTS.

Chlorine Dioxide One Year Later. Shazelle Terry Treatment & WQ Department Manager

Challenges in Municipal Water Treatment and the MIOX Solution. Part 2 of 3: Groundwater Treatment

MAKING BLEACH MADE EASY

Drinking Water Disinfection A History and Improved Monitoring Techniques. Randy Turner Technical Director, Chemist Swan Analytical USA

COMBITECH. A. Forslund P. Fogh, E.J. Jurgensen, A. Dalsgaard, H.C. Bruun Hansen

Chlorination/Dechlorination: An Environmental Solution

Electricide HG Electrochemical Chlorine Generators

Hypochlorite Production General Information. 740 E. Monroe Road, St. Louis, MI

Graham Hill Water Treatment Plant Upgrades Status Update

COOLING TECHNOLOGY INSTITUTE

CGN 6933: Drinking Water Treatment Processes Department of Civil & Environmental Engineering University of South Florida Cunningham Spring 2013

Chlorine Dioxide Feed System for Pre-Oxidation

Chlorine Decay Modeling and Water Age Predictions

KLORIGEN. On-site Generation of Chlorine & Sodium Hypochlorite. Bringing Technology to Life

Field experience by water treatment facilities of Chlorine Dioxide & Chlorine Compound Disinfectant, replacing the traditional chlorine treatment

Drinking Water Disinfection For Operators, Town Councils, and LSD Committees

Chlorine Dioxide Feed System for Pre-Oxidation at an 8 MGD WTP

Selcoperm electrolytic chlorination system

4709 Hwy 36 South, Suite 10 Rosenberg, TX Phone:

SANITIZING OF MILK CASE WASHERS AND TRANSPORT CONVEYORS: AN OVERVIEW OF CURRENT PRACTICES AND ADVANTAGES OF CHLORINE DIOXIDE USE

Only a small concentration of this Sodium Hypochlorite is required to combat marine fouling, 0.1 to 0.3 ppm.

Advanced Oxidation Processes: Treatment of 1,4-Dioxane and VOCs for Potable Water Applications

Societal and Macroeconomic Assessment of Alternative Technologies for Disinfecting Drinking Water

Challenges in Municipal Water Treatment and the MIOX Solution

Disinfection. The Case for Chlorine. Chlorine is highly reactive. Chlorine Based Disinfectants. The EPA requires a chlorine residual

ENVIRONMENTAL ENGINEERING LECTURE 3: WATER TREATMENT MISS NOR AIDA YUSOFF

Water sanitation at its best

New Technologies for Hypo Production

Future Drinking Water Regulations

gaffey UNCOMPROMISING WATER DISINFECTION SYSTEMS Electrolytic chlorination WATER TREATMENT FOR LIFE

Homework #7 Topic: Disinfection Due Tues., April 12 Assignment for 2018: Answer problem 1; then choose two of problems 4, 5, 8.

Applications of electrochemistry

Control of Oomycete Pathogens in Irrigation Water of soft fruits

Well Treatment Facility Option 2. Treatment Facility Option 1. Pipeline Well Treatment Facility. Well and 69-02

UNCD ELECTRODES. Technical Performance Data. Advanced Diamond Technologies, Inc.

Chloramine and Nitrification... Is There a Simple Solution?

INTRODUCTION. A System Approach to Sustainable Cleaning & Disinfecting

A factual look at the chlorine based methods of disinfecting water in North America

Mitigation of Bromate during Ozonation

What is Chlorine Dioxide and Why You Should Learn About It Now?

Recycled Water: A New Source for Private Water Systems in Ohio

The statement of verification is available on the ETV Registry at the following webpage

MICROBICIDES FOR COOLING WATER SYSTEMS

WATER BASICS ENGR. ALBERT SAMUELA KHUN UNNOP TONGYA

Consumer confidence report

Electro-Chemical UET Water Treatment System Achieves Sustainability Objectives for Scottsdale Fashion Square Mall.

Disinfection By-Products Reduction and SCADA Evaluation and WTP Sludge Removal System and Dewatering Facility

carbon anode/+ (1) electrolyte Al 2 O 3 with or dissolved in or solution in cathode/ (1) (steel outer)

Influence of operating parameters on ammonia nitrogen removal from micro-polluted water by electro-coagulation-flotation with aluminum electrodes

CHLORAMINATION AND CHLORAMINE ANALYSIS

BALCLOR TM Ballast Water Treatment System. SunRui Corrosion and Fouling Control Company 3 December 2009, Shanghai China

Regulatory Status of Emerging Contaminants

Section 5: Water Quality

Should we use a residual in our drinking water distribution systems?

carbon dioxide hydrogen hydrogen chloride oxygen answer... [1] [1]

WEFTEC.06. Lake Okeechobee, Actiflo, peroxone, surface water, Cyanobacteria

Aeration Strategies for TTHM Control

Balancing Microbial Control and Stage 2 DBP Rule Compliance (at Ocean City, Maryland)

Effective Disinfection For Healthy Water. GRUNDFOS Disinfection

QUESTION 1 One difference in the electrode reactions of an electrolytic cell compared to a galvanic cell is:

Gretchen Onstad ENV H /15/11

Property of ChemTreat, Inc. Do not copy without permission.

OSEC B-Pak - Frequently Asked Questions

Pittsburgh Water Treatment Plant Projects. by Jay R. Lucas, P.E. Senior Project Manager

Occurrence of UCMR Contaminants in Drinking Water materials and Treatment Chemicals

Operation and Maintenance of Electrochlorination Plant

Figures...vii Tables... ix Acknowledgments... xi Foreword... xiii Preface...xv

AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal

In-Reservoir TTHM Surface Aeration: A year of results, experience and lessons learned

Joseph Roccaro Water Quality Engineer Suffolk County Water Authority LI Water Conference Legislative Breakfast March 9, 2018

Offshore Hypochlorite Generation

ULTRASOUND AS A SOLE OR SYNERGISTIC DISINFECTANT IN DRINKING WATER. Kar Yee Karen Wong. A Thesis. Submitted to the Faculty. of the

Electrode Product Application. Japan Carlit Co.,Ltd 8 June 2015

Which Chlorine Monitoring Method is Most Effective?

Chlorine Scrubbing: Conversion from Batch to Continuous. Brent Hardman, P.E. Powell Fabrication & Mfg., Inc.

ADVANCES IN UV TECHNOLOGY FOR 4-LOG VIRUS DISINFECTION OF GROUNDWATER. Scott Bindner OWWA Annual Conference May 2014

Hydraulic Modeling Assisting in Water Quality. Jinghua Jing Xiao, Ph.D., P.E. Senior Planning Engineer SE PA-AWWA Fall Conference 2018

Disinfection By-Products

Concentration-Time (CT) Assessment Theory and Application Examples. Daniel B. Stephens & Associates, Inc.

James Farrell, Chemical and Environmental Engineering, UA James C. Baygents, Chemical and Environmental Engineering, UA

Coupling electrochemical with biological oxidation of 1,4-dioxane:

Impregnate Technology Platform

Basic Steps in DW Treatment Process. Water Treatment. EPA and DBP s. Scottsdale Chaparral DW Plant

GRUNDFOS WHITE PAPER. Chlorine dioxide offers increased efficiency and

Cyanotoxin Evaluation and Treatment in the New York State Finger Lakes Region Pennsylvania AWWA Annual Conference

Our mission is to provide cost effective, safe, environmentally responsible solutions to bacterial control in the food and water industries

EVALUATION OF CHLORINE DIOXIDE IN POTABLE WATER SYSTEMS FOR LEGIONELLA CONTROL IN A ACUTE CARE HOSPITAL ENVIRONMENT

ElectroPure Technology. Water Treatment System

CHEMICAL DOSING AND DISINFECTION

Transcription:

Status of Chlorate Regulations & Impact at Water Treatment Plants Pennsylvania Annual AWWA Conference Hershey, PA April 18, 2018 ELECTRODE TECHNOLOGIES & WATER TECHNOLOGIES

Background on Chlorate 2

What is Chlorate? Chlorate is a highly oxidized form of chlorine, can be introduced to a water source as an industrial or agricultural contaminant or into a finished water as a disinfection byproduct (DBP). 3

Chlorate Likely to be Regulated Chlorate (ClO3-) is on the EPA s Third Chemical Contaminant List (CCL3) Indicating that the intention of the Environmental Protection Agency (EPA) to review chlorate as a potential candidate for regulation under the Safe Drinking Water Act. Currently, not regulated in the United States and there is no enforceable Maximum Contaminant Limit (MCL). Canada MCL is 1.0 mg/l (1000µg/l) WHO recommends a chlorate limit of 0.7 mg/l (700 µg/l) While no final recommendation has been promulgated, literature on the topic indicated that the regulation may fall within the range of 0.21 mg/l (210 µg/l) to 0.7 mg/l (700 µg/l) in the US. 4

Chlorate - Future Regulatory Challenge While 210 µg/l is established by the EPA as a health reference level, it is conjectured that the EPA will not establish such a low level as it will seriously impact the viability of using delivered bulk hypochlorite in the marketplace. A level of 210 µg/l is also predicted to impact 34% of utilities using On-Site Generation. 5

Factors Influencing Chlorate Formation Time (storage time) Storage Temperature Hypochlorite concentration The higher or longer any of these are, the more chlorate that will form 6

Chlorate Impacts on Bulk Hypochlorite To limit chlorate formation, users of bulk hypochlorite may need to: Move storage indoor, if not already located there. Cool the room where the hypochlorite is stored to retard degradation. Require born-on dating from the manufacturers to ensure freshness. Limit storage volumes. Purchase lower concentrations to slow the degradation. Dilute the concentrated hypochlorite once it has been delivered to the treatment plant. All of these will have significant cost impacts!!!!! 7

What About On-Site Generation? On-site generation is when basic, simple chemicals are used to generate chemical at the point of use. In this case, the hypochlorite is produced is generated using salt.

Chlorate Impacts on On-Site Generation Chlorate ions are produced as an undesirable side reaction of the electrochemical process. In the process, a portion of the hypochlorous acid or hypochlorite ions are oxidized at the anode to produce chlorate ions. Research to date on chlorate production by installed commercial electrolytic OSG systems has not found any correlation between OSG brand, age, capacity, or a variety of operational conditions. 9

Theoretical Advantages of On-Site Generated on-site always fresh. <1% chlorine concentration = very slow degradation rate. Modular in nature as regulations change, upgrades are simple and easy to implement. These are all valid and minimize the degradation so focus must be on the generation process itself. 10

Why Use On-Site Generation?

Safety is One Major Reason Regulations Trend toward the safest solution Limit on hazardous chemical storage Incidents Fairly recent near miss of Cl 2 leak at two large industrial facilities (US) Sustainability Less trucks, lower carbon footprint Water conservation, less chemicals

Maintain efficacy of FAC is yet another

Operational Cost is Another To produce 1 lb of 100% Free Available Chlorine equivalent to 1 gallons of 12.5% hypo Salt $0.36 Electricity + $0.18 = Operational Cost MIOX Cost ~$0.54 3 lbs salt at $0.12/lbs (or delivered brine) 2.5 kw-hr power at $0.07/kW-hr Equivalent to 1 gallon of delivered 12.5% sodium hypochlorite ~$0.10 addt l including parts maintenance Equivalent Operational Cost 12.5% Sodium Hypochlorite Chlorine Gas $0.65 ~ $2.50 $0.40 ~ $.75

How Does It Work?

Typical Process Flow

HYPO HYPOCHLORITE MOS HYPO + PEROXIDE 17

Cell Reactions Anode Primary Reaction (+ Side): 2 Cl- Cl 2 + 2 e- Cathode Reaction (- Side): 2 H 2 O + 2 e- H 2 + 2 OH- Chlorine Hydrolysis Reaction: Cl 2 + H 2 O HOCl + Cl- + H+ HOCl Equilibrium Reaction: HOCl OCl- + H+ (depends on ph) If you stop here, you have a hypochlorite generator

Cell Reactions Anode Primary Reaction (+ Side): 2 Cl- Cl 2 + 2 e- Cathode Reaction (- Side): 2 H 2 O + 2 e- H 2 + 2 OH- Chlorine Hydrolysis Reaction: Cl 2 + H 2 O HOCl + Cl- + H+ HOCl Equilibrium Reaction: HOCl OCl- + H+ (depends on ph) If you stop here, you have a hypochlorite generator But if you add more power Anode Secondary Reaction (+ Side): 2 OH- H 2 O 2 + 2 e-

Biofilm Removal Across Many Applications Piping Pool Condenser Frac Pond Gravity Filter Hot Tub Cooling HVAC Cost Safety Control

Thank You for Your Time... Questions? Bob Newton Director Business Development OSHG (215) 272-8966 (Mobile) robert.newton@denora.com 21