Declaration of Performance

Similar documents
Declaration of Performance

Declaration of Performance No. DPGEB1018 v2

Declaration of Performance

Declaration of Performance No. DPGEB1006 v2.1

Declaration of Performance

Declaration of Performance Number 1219-DPC-0071 According to Regulation EU No 305/2011

English translation prepared by CSTB - Original version in French language

ETA-11/0141 of 08/08/2016. European Technical Assessment. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej


English translation prepared by CSTB - Original version in French language. Injection system DeWalt PURE110-PRO

English translation prepared by CSTB - Original version in French language

Designated according to Article 29 of Regulation (EU) No 305/2011 and member of EOTA (European Organisation for Technical Assessment)

Designated according to Article 29 of Regulation (EU) No 305/2011 and member of EOTA (European Organisation for Technical Assessment)

Declaration of Performance

Intended uses of the construction product, in accordance with the applicable harmonized technical specification as foreseen by the manufacturer:

SVM-PSC Polyester resin for use in concrete

European Technical Assessment ETA-14/0454 of 11/12/2014

English translation prepared by CSTB - Original version in French language

English translation prepared by CSTB - Original version in French language. Tecfi S.p.A. SS Appia km 193 Pastorano (CE) 81050, Italia

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

DECLARATION OF PERFORMANCE

English translation prepared by CSTB - Original version in French language

DECLARATION OF PERFORMANCE

Declaration of Performance No1109-CPD-0080 According to the Regulation EU No 305/2011


English translation prepared by CSTB - Original version in French language

DECLARATION OF PERFORMANCE

European Technical Assessment ETA-15/0288 of 17/06/2015

European Technical Approval ETA-11/0344

Declaration of Performance No1109-CPD-0079 According to the Regulation EU No 305/2011 HXE01 - HXE02 - HXE12 - HXE85 - HXE03

Hilti HIT-CT 1 with HIT-V

PRODUCT DATA SHEET THROUGH BOLTS. facebook.com/sormat youtube.com/sormatfixing SORMAT Product data sheet 1217

PRODUCT DATA SHEET THROUGH BOLTS S-KA S-KAK S-KAH A4 S-KAH HCR S-KAR A2 HHA A2

European Technical Assessment. ETA-17/0237 of 15/05/2017. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

HST Carbon steel. HST-R Stainless steel HST-HCR High corrosion resistance steel. Fire resistance

General Information. Installation Information Design Information Material Information Ordering Information

ETA-13/0584 of 24/09/2014. European Technical Assessment. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

ETA-13/0058 Assessment

EJOT Through Bolts. Premium-quality through bolts for fixing in cracked and non-cracked concrete.

SINGLE ANCHOR USE FOR NON-CRACKED CONCRETE

L Length [mm] [mm] 3. Intended use Generic type: Torque controlled expansion anchor throughtbolt type. Made of steel, zinc plated ISO 4042 A2

English translation prepared by CSTB - Original version in French language. Simpson Strong-Tie ZAC. Les 4 chemins Sainte-Gemme-la-Plaine France

European Technical Approval ETA-08/0376

European Technical Assessment. ETA-11/0336 of 17 July English translation prepared by DIBt - Original version in German language.

HKD Push-in anchor, Single anchor application

HVU with HAS/HAS-E rod adhesive anchor system

ue du Bâtiment Techniqu Member of General Part Trade name produit Product family Famille de Titulaire Manufacturer Harjutie 5 Finland

PRODUCT DATA SHEET SAFETY BOLT

Technical data No. 17/0001 of 25/04/2017

HKD Push-in anchor, Single anchor application

European Technical Assessment. ETA-12/0398 of 29/12/2017. General Part. Instytut Techniki Budowlanej. Technical Assessment Body issuing the

English translation prepared by CSTB - Original version in French language. FRIULSIDER Via Trieste,1 I San Giovanni al Natisone (UDINE) ITALIE

English translation prepared by CSTB - Original version in French language

HDA-P HDA-PR HDA-PF Anchor for presetting. HDA-T HDA-TR HDA-TF Anchor for through-fasting. Nuclear power plant approval

English translation prepared by CSTB - Original version in French language. Injection System ZETACHEM EPX 30 / 41

Intended uses of the construction product, in accordance with the applicable harmonized technical specification as foreseen by the manufacturer:

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

Approvals / Certificates:

Hilti HIT-HY 170 mortar with HIT-V rod. Anchor Fastening Technology Manual. Hilti HIT-HY 170 with HIT-V HIS-(R)N 03 / /

ITW Construction Products Italy S.r.l. V.le Regione Veneto, PADOVA (PD) ITALIEN. V.le Regione Veneto, PADOVA (PD) ITALIEN

Type or serial number or any other element allowing identification of the construction product as

English translation prepared by CSTB - Original version in French language POWERS PB-PRO-S

HKD Push-in anchor, Single anchor application

Type or serial number or any other element allowing identification of the construction product as

Injection System Batifix VIFIX V. BATIFIX Z.A. La Gravière FAREINS FRANCE. Plant France 1

Anchor HSA Fastening. Technology Manual HSA. Stud anchor. Version /

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

SIMPLY THE BEST HEAVY DUTY SELF-UNDERCUTTING ANCHOR IN THE WORLD

SOUDAFIX VE400-SF. Temperature -10 C (1) -5 C 0 C 5 C 10 C 20 C 30 C 35 C 40 C

Typical Applications. 1) Concrete Temperature 2) Cartridge Temperature must be min. +15 C. 3) Cartridge Temperature must be under +20 C.

English translation prepared by CSTB - Original version in French language. Smart expansion anchor types H / T / K

Société SPIT Route de Lyon F BOURG-LES-VALENCE France. Société SPIT Route de Lyon F BOURG-LES-VALENCE France

R-CAS-V Spin-In Capsule with Threaded Rods

English translation prepared by CSTB - Original version in French language. FM753 Crack

European Technical Approval ETA-98/0001

English translation prepared by CSTB - Original version in French language. Throughbolt TX

E TA TECHNICAL REPORT. Evaluation of Anchorages in Concrete concerning Resistance to Fire. TR 020 Edition May 2004

(English language translation, the original version is in French language) SPIT FIX Z A4. Société SPIT Route de Lyon F BOURG-LES-VALENCE

(English language translation, the original version is in French language) SPIT FIX Z A4. Société SPIT Route de Lyon F BOURG-LES-VALENCE

DECLARATION OF PERFORMANCE

(English language translation, the original version is in French language) ELEMATIC ETD Z A4 10/04/ /01/2017

Hilti-HY 110 available in 330ml and 500ml foil packs. Static mixer HIT M1. Rebar BSt 500 S

SHP-VE / Hammer-in capsule Vinylester capsule resin for use in concrete

English translation prepared by CSTB - Original version in French language. Stud anchor BOAX-FMC

System Components. Grades. General Information. Installation Information Design Information Material Information Ordering Information

Epoxy Injection System with ETA Assessment Option 1 for Cracked & Non-Cracked Concrete SA TS 101:2015 Compliant

English translation prepared by CSTB - Original version in French language. Injection system Hilti HIT-RE 500 V3

HUS3-H 8 / 10 / 14 Carbon steel concrete screw with hexagonal head. HUS3-C 8 / 10 Carbon steel concrete screw with countersunk head

Internal dry conditions Static or quasi-static loads Seismic actions for Performance Category C1 and C2 Fire exposure

M6 M8 M10 M12 M16 M20

(English language translation, the original version is in French language) Hilti HSA and HSA-R

English translation prepared by CSTB - Original version in French language. Injection system Hilti HIT-RE 500 V3

HST3 Metal expansion anchor

EJOT Concrete screws. ETA-approved concrete screws for cracked and non-cracked concrete

English translation prepared by CSTB - Original version in French language SPIT EPOMAX. Société SPIT Route de Lyon F BOURG-LES-VALENCE FRANCE

(English language translation, the original version is in French language) Injection system Chemfix CH+

European Technical Approval ETA- 10/0230

Transcription:

Expandet ESI Extreme Pro, EVL Extreme Pro (galvanized or stainless steel bonded anchor) Intended use or uses of the construction product according to ETAG 001 parts 1 and 5 Generic type Bonded anchor for anchorage of threaded rod Base material Cracked and Un-cracked concrete C20/25 to C50/60 acc. to EN 206-1:2003 Steel, zinc plated 5 µm acc. to EN ISO 4042:1999 or hot-dip galvanised 40 µm Material acc. to EN ISO 1461:2009 and EN ISO 10684:2004+AC:2009 A Property class 4.6, 4.8, 5.8, 8.8 acc. EN 898-1 & EN 898-2 Durability Internal dry conditions Material Stainless steel: M24: A4-70 ; > M24 A4-50 according to EN ISO 3506 B C Durability Material Durability Dry internal conditions, external atmospheric exposure (including industrial and marine environment) or exposure in permanently damp internal conditions if no particular aggressive conditions exist. Stainless steel 1.4529 & 1.4565: M24: class 70 ; > M24 class 50 according to EN ISO 3506 dry internal conditions, external atmospheric exposure, in permanently damp internal conditions or in other particular aggressive conditions - e.g. permanent, alternating immersion in seawater, splash zone of seawater, chloride atmosphere of indoor swimming pools or atmosphere with chemical pollution (e.g. in desulphurization plants or road tunnels where de-icing materials are used). Loading (A,B,C) Fire Resistance Fire Reaction Static, quasi-static & seismic. NPD A1 according to EN13501-1 Generic type Bonded anchor for anchorage of reinforcing bar Base material Cracked and Un-cracked concrete C20/25 to C50/60 acc. to EN 206-1:2003 Material of reinforcing bar D Class B and C as EN 1992-1-1 Annex C Loading Static, quasi-static & Seismic Fire Reaction Service temperature range Use category A1 according to EN13501-1 I: -40 C to +40 C (max. short term temperature +40 C and max. long term temperature +24 C). II: -40 C to +80 C (max. short term temperature +80 C and max. long term temperature +50 C). III: -40 C to +120 C (max. short term temperature +120 C and max. long term temperature +72 C). Category 1 & 2:, flooded holes are allowed. Drilling method: Hammer drilling. ETA 16/0959 issued by DIBT On the basis of ETAG 001, according to Article 29 of the Regulation (EU) No 305/2011 Certificate of constancy of performance STAATLICHE MATERIALPRÜFUNGSANSTALT DARMSTADT 1343-CPR-M 628-1 Page 1-11

Installation parameters for threaded rod Anchor size M 8 M 10 M 12 M 16 M 20 M 24 M 27 M 30 Nominal drill hole diameter d 0 [mm] = 10 12 14 18 24 28 32 35 Effective anchorage depth Diameter of clearance hole in the fixture h ef,min [mm] = 60 60 70 80 90 96 108 120 h ef,max [mm] = 160 200 240 320 400 480 540 600 d f [mm] 9 12 14 18 22 26 30 33 Diameter of steel brush d b [mm] 12 14 16 20 26 30 34 37 Torque moment T inst [Nm] 10 20 40 80 120 160 180 200 Thickness of fixture t fix,min [mm] > 0 t fix,max [mm] < 1500 Minimum thickness of member h min [mm] h ef + 30 mm 100 mm h ef + 2d 0 Minimum spacing s min [mm] 40 50 60 80 100 120 135 150 Minimum edge distance c min [mm] 40 50 60 80 100 120 135 150 Installation parameters for rebar Rebar size Æ 8 Æ 10 Æ 12 Æ 14 Æ 16 Æ 20 Æ 25 Æ 28 Æ 32 Nominal drill hole diameter d 0 [mm] = 12 14 16 18 20 24 32 35 40 Effective anchorage depth h ef,min [mm] = 60 60 70 75 80 90 100 112 128 h ef,max [mm] = 160 200 240 280 320 400 480 540 640 Diameter of steel brush d b [mm] 14 16 18 20 22 26 34 37 41,5 Minimum thickness of member h min [mm] h ef + 30 mm 100 mm h ef + 2d 0 Minimum spacing s min [mm] 40 50 60 70 80 100 125 140 160 Minimum edge distance c min [mm] 40 50 60 70 80 100 125 140 160 Page 2-11

Characteristic values of tension loads under static, quasi-static action and seismic action (performance category C1) Anchor size threaded rod M 8 M 10 M 12 M 16 M 20 M24 M27 M30 Steel failure Characteristic tension resistance N Rk,s =N Rk,s,seis [kn] A s f uk Combined pull-out and concrete failure Characteristic bond resistance in non-cracked concrete C20/25 t Rk,ucr [N/mm²] 10 12 12 12 12 11 10 9 t Rk,ucr [N/mm²] 7,5 8,5 8,5 8,5 not admissible t Rk,ucr [N/mm²] 7,5 9 9 9 9 8,5 7,5 6,5 t Rk,ucr [N/mm²] 5,5 6,5 6,5 6,5 not admissible t Rk,ucr [N/mm²] 5,5 6,5 6,5 6,5 6,5 6,5 5,5 5,0 t Rk,ucr [N/mm²] 4,0 5,0 5,0 5,0 not admissible Characteristic bond resistance in cracked concrete C20/25 t Rk,cr [N/mm²] 4,0 5,0 5,5 5,5 5,5 5,5 6,5 6,5 t Rk,C1 [N/mm²] 2,5 3,1 3,7 3,7 3,7 3,8 4,5 4,5 t Rk,cr [N/mm²] 4,0 4,0 5,5 5,5 not admissible t Rk,C1 [N/mm²] 2,5 2,5 3,7 3,7 not admissible t Rk,cr [N/mm²] 2,5 3,5 4,0 4,0 4,0 4,0 4,5 4,5 t Rk,C1 [N/mm²] 1,6 2,2 2,7 2,7 2,7 2,8 3,1 3,1 t Rk,cr [N/mm²] 2,5 3,0 4,0 4,0 not admissible t Rk,C1 [N/mm²] 1,6 1,9 2,7 2,7 not admissible t Rk,cr [N/mm²] 2,0 2,5 3,0 3,0 3,0 3,0 3,5 3,5 t Rk,C1 [N/mm²] 1,3 1,6 2,0 2,0 2,0 2,1 2,4 2,4 t Rk,cr [N/mm²] 2,0 2,5 3,0 3,0 not admissible t Rk,C1 [N/mm²] 1,3 1,6 2,0 2,0 not admissible Page 3-11

Characteristic values of tension loads under static, quasi-static action and seismic action (performance category C1) C25/30 1,02 Increasing factors for concrete (only static or quasi-static actions) y c C30/37 1,04 C35/45 1,07 C40/50 1,08 C45/55 1,09 C50/60 1,10 Factor according to CEN/TS 1992-4-5 Section 6.2.2.3 Non-cracked concrete 10,1 k 8 [-] Cracked concrete 7,2 Concrete cone failure Factor according to CEN/TS 1992-4-5 Section 6.2.3.1 Non-cracked concrete k ucr [-] 10,1 Cracked concrete k cr [-] 7,2 Edge distance c cr,n [mm] 1,5 h ef Axial distance s cr,n [mm] 3,0 h ef Splitting Edge distance c cr,sp [mm] æ h ö 1,0 hef 2 hef ç2,5-2,4 hef h è ef ø Axial distance s cr,sp [mm] 2 c cr,sp Installation safety factor () γ 2 = γ inst 1,0 1,2 Installation safety factor () γ 2 = γ inst 1,4 not admissible Page 4-11

Characteristic values of shear loads under static, quasi-static action and seismic action (performance category C1) Anchor size threaded rod M 8 M 10 M 12 M 16 M 20 M24 M 27 M 30 Steel failure without lever arm Characteristic shear resistance V Rk,s [kn] 0,50 A s f uk V Rk,s,C1 [kn] 0,35 A s f uk Ductility factor according to CEN/TS 1992-4-5 Section 6.3.2.1 k 2 0,8 Steel failure with lever arm Characteristic bending moment M 0 Rk,s [Nm] 1.2 W el f uk M 0 Rk,s,C1 [Nm] No Performance Determined (NPD) Concrete pry-out failure Factor k 3 in equation (27) of CEN/TS 1992-4-5 Section 6.3.3 Factor k in equation (5.7) of k (3) 2,0 Technical Report TR 029 Installation safety factor γ 2 = γ inst 1,0 Concrete edge failure Effective length of anchor l f [mm] l f = min(h ef; 8 d nom) Outside diameter of anchor d nom [mm] 8 10 12 16 20 24 27 30 Installation safety factor γ 2 = γ inst 1,0 Page 5-11

Characteristic values of tension loads under static, quasi-static action and seismic action (performance category C1) Anchor size reinforcing bar Æ 8 Æ 10 Æ 12 Æ 14 Æ 16 Æ 20 Æ 25 Æ 28 Æ 32 Steel failure Characteristic tension resistance N Rk,s = N Rk,s,seis [kn] A s f uk Combined pull-out and concrete failure Characteristic bond resistance in non-cracked concrete C20/25 t Rk,ucr [N/mm²] 10 12 12 12 12 12 11 10 8,5 t Rk,ucr [N/mm²] 7,5 8,5 8,5 8,5 8,5 not admissible t Rk,ucr [N/mm²] 7,5 9 9 9 9 9 8,0 7,0 6,0 t Rk,ucr [N/mm²] 5,5 6,5 6,5 6,5 6,5 not admissible t Rk,ucr [N/mm²] 5,5 6,5 6,5 6,5 6,5 6,5 6,0 5,0 4,5 t Rk,ucr [N/mm²] 4,0 5,0 5,0 5,0 5,0 not admissible Characteristic bond resistance in cracked concrete C20/25 t Rk,cr [N/mm²] 4,0 5,0 5,5 5,5 5,5 5,5 5,5 6,5 6,5 t Rk,C1 [N/mm²] 2,5 3,1 3,7 3,7 3,7 3,7 3,8 4,5 4,5 t Rk,cr [N/mm²] 4,0 4,0 5,5 5,5 5,5 not admissible t Rk,C1 [N/mm²] 2,5 2,5 3,7 3,7 3,7 not admissible t Rk,cr [N/mm²] 2,5 3,5 4,0 4,0 4,0 4,0 4,0 4,5 4,5 t Rk,C1 [N/mm²] 1,6 2,2 2,7 2,7 2,7 2,7 2,8 3,1 3,1 t Rk,cr [N/mm²] 2,5 3,0 4,0 4,0 4,0 not admissible t Rk,C1 [N/mm²] 1,6 1,9 2,7 2,7 2,7 not admissible t Rk,cr [N/mm²] 2,0 2,5 3,0 3,0 3,0 3,0 3,0 3,5 3,5 t Rk,C1 [N/mm²] 1,3 1,6 2,0 2,0 2,0 2,0 2,1 2,4 2,4 t Rk,cr [N/mm²] 2,0 2,5 3,0 3,0 3,0 not admissible t Rk,C1 [N/mm²] 1,3 1,6 2,0 2,0 2,0 not admissible Page 6-11

Characteristic values of tension loads under static, quasi-static action and seismic action (performance category C1) C25/30 1,02 Increasing factors for concrete (only static or quasi-static actions) y c C30/37 1,04 C35/45 1,07 C40/50 1,08 C45/55 1,09 C50/60 1,10 Factor according to CEN/TS 1992-4-5 Section 6.2.2.3 Non-cracked concrete 10,1 k 8 [-] Cracked concrete 7,2 Concrete cone failure Factor according to CEN/TS 1992-4-5 Section 6.2.3.1 Non-cracked concrete k ucr [-] 10,1 Cracked concrete k cr [-] 7,2 Edge distance c cr,n [mm] 1,5 h ef Axial distance s cr,n [mm] 3,0 h ef Splitting Edge distance c cr,sp [mm] 1,0 hef æ h ö 2 hef ç2,5-2,4 hef h è ef ø Axial distance s cr,sp [mm] 2 c cr,sp Installation safety factor () γ 2 = γ inst 1,0 1,2 Installation safety factor () γ 2 = γ inst 1,4 not admissible Page 7-11

Characteristic values of shear loads under static, quasi-static action and seismic action (performance category C1) Anchor size reinforcing bar Æ 8 Æ 10 Æ 12 Æ 14 Æ 16 Æ 20 Æ 25 Æ 28 Æ 32 Steel failure without lever arm Characteristic shear resistance Ductility factor according to CEN/TS 1992-4-5 Section 6.3.2.1 V Rk,s [kn] 0,50 A s f uk V 0 Rk,s,C1 [kn] not admissible 0,35 A s f uk k 2 0,8 Steel failure with lever arm Characteristic bending moment M 0 Rk,s [Nm] 1.2 W el f uk M 0 Rk,s, C1 [Nm] No Performance Determined (NPD) Concrete pry-out failure Factor k 3 in equation (27) of CEN/TS 1992-4-5 Section 6.3.3 Factor k in equation (5.7) of k (3) 2,0 Technical Report TR 029 Installation safety factor γ 2 = γ inst 1,0 Concrete edge failure Effective length of anchor l f [mm] l f = min(h ef; 8 d nom) Outside diameter of anchor d nom [mm] 8 10 12 14 16 20 25 28 32 Installation safety factor γ 2 = γ inst 1,0 Page 8-11

Displacements under tension load 1) (threaded rod) Anchor size threaded rod M 8 M 10 M 12 M 16 M 20 M24 M 27 M 30 Non-cracked concrete C20/25 d N0-factor [mm/(n/mm²)] 0,021 0,023 0,026 0,031 0,036 0,041 0,045 0,049 d N -factor [mm/(n/mm²)] 0,030 0,033 0,037 0,045 0,052 0,060 0,065 0,071 d N0-factor [mm/(n/mm²)] 0,050 0,056 0,063 0,075 0,088 0,100 0,110 0,119 d N -factor [mm/(n/mm²)] 0,072 0,081 0,090 0,108 0,127 0,145 0,159 0,172 d N0-factor [mm/(n/mm²)] 0,050 0,056 0,063 0,075 0,088 0,100 0,110 0,119 d N -factor [mm/(n/mm²)] 0,072 0,081 0,090 0,108 0,127 0,145 0,159 0,172 Cracked concrete C20/25 d N0-factor [mm/(n/mm²)] 0,090 0,070 d N -factor [mm/(n/mm²)] 0,105 0,105 d N0-factor [mm/(n/mm²)] 0,219 0,170 d N -factor [mm/(n/mm²)] 0,255 0,245 d N0-factor [mm/(n/mm²)] 0,219 0,170 d N -factor [mm/(n/mm²)] 0,255 0,245 1) Calculation of the displacement: d N0 = d N0-factor t; t: action bond stress for tension d N = d N -factor t; Displacements under shear load 1) (threaded rod) Anchor size threaded rod M 8 M 10 M 12 M 16 M 20 M24 M 27 M 30 For non-cracked concrete C20/25 All temperature ranges For cracked concrete C20/25 All temperature ranges d V0-factor [mm/(kn)] 0,06 0,06 0,05 0,04 0,04 0,03 0,03 0,03 d V -factor [mm/(kn)] 0,09 0,08 0,08 0,06 0,06 0,05 0,05 0,05 d V0-factor [mm/(kn)] 0,12 0,12 0,11 0,10 0,09 0,08 0,08 0,07 d V -factor [mm/(kn)] 0,18 0,18 0,17 0,15 0,14 0,13 0,12 0,10 1) Calculation of the displacement: d V0 = d V0-factor V; V: action shear load d V = d V -factor V; Page 9-11

Displacements under tension load 1) (rebar) Anchor size reinforcing bar Æ 8 Æ 10 Æ 12 Æ 14 Æ 16 Æ 20 Æ 25 Æ 28 Æ 32 Non-cracked concrete C20/25 d N0-factor [mm/(n/mm²)] 0,021 0,023 0,026 0,028 0,031 0,036 0,043 0,047 0,052 d N -factor [mm/(n/mm²)] 0,030 0,033 0,037 0,041 0,045 0,052 0,061 0,071 0,075 d N0-factor [mm/(n/mm²)] 0,050 0,056 0,063 0,069 0,075 0,088 0,104 0,113 0,126 d N -factor [mm/(n/mm²)] 0,072 0,081 0,090 0,099 0,108 0,127 0,149 0,163 0,181 d N0-factor [mm/(n/mm²)] 0,050 0,056 0,063 0,069 0,075 0,088 0,104 0,113 0,126 d N -factor [mm/(n/mm²)] 0,072 0,081 0,090 0,099 0,108 0,127 0,149 0,163 0,181 Cracked concrete C20/25 d N0-factor [mm/(n/mm²)] 0,090 0,070 d N -factor [mm/(n/mm²)] 0,105 0,105 d N0-factor [mm/(n/mm²)] 0,219 0,170 d N -factor [mm/(n/mm²)] 0,255 0,245 d N0-factor [mm/(n/mm²)] 0,219 0,170 d N -factor [mm/(n/mm²)] 0,255 0,245 1) Calculation of the displacement: d N0 = d N0-factor t; t: action bond stress for tension Displacement under shear load 1) (rebar) d N = d N -factor t; Anchor size reinforcing bar Æ 8 Æ 10 Æ 12 Æ 14 Æ 16 Æ 20 Æ 25 Æ 28 Æ 32 Non-cracked concrete C20/25 All temperature ranges Cracked concrete C20/25 All temperature ranges d V0-factor [mm/(kn)] 0,06 0,05 0,05 0,04 0,04 0,04 0,03 0,03 0,03 d V -factor [mm/(kn)] 0,09 0,08 0,08 0,06 0,06 0,05 0,05 0,04 0,04 d V0-factor [mm/(kn)] 0,12 0,12 0,11 0,11 0,10 0,09 0,08 0,07 0,06 d V -factor [mm/(kn)] 0,18 0,18 0,17 0,16 0,15 0,14 0,12 0,11 0,10 1) Calculation of the displacement: d V0 = d V0-factor V; V: action shear load d V = d V -factor V; Page 10-11

The performance of the product identified above is in conformity with the set of declared performance/s. This declaration of performance is issued, in accordance with Regulation (EU) No 305/2011, under the sole responsibility of the manufacturer identified above. Signed for and on behalf of Expandet Screw Anchors A/S by: Place and date of issue: Græsted, 31/12/2016 Lars Mortensen, Head of Technical Department Page 11-11