RhinoBond Induction Fixing System

Similar documents
Electromagnetic Induction Welding

Worldwide Competence in Plastics. Development by professionals. The long-lasting roof system

STOMP OUT FLUTTER. Non-penetrating fastening system for thermoplastic roofing

CARLISLE ROOFING SYSTEM

J41 Reinforced bitumen membrane roof coverings

STOMP OUT FLUTTER. Non-penetrating fastening system for thermoplastic roofing

SECTION 07530CP EPDM MEMBRANE ROOFING

Mounting System MCG 1.1 Membrane-Connected Glass. System description

Firestone UltraPly TM TPO Accessories. Products designed to take your UltraPly TPO roof even

Finish for topped and smooth surfaces, with or without chips. Pore and cavity filler, joint filler, adhesive for tiles etc.

INOFIN FPO roofing membrane

1 Firestone EPDM Roofing Systems

Protan Exposed Membrane Roof. Your design - Our solution

SRP-AirOutshield UV Issued:

J41 Reinforced bitumen membrane roof coverings

Installation Instructions ALUTRIX 600 ALUTRIX FR

Polymeric membrane for roof waterproofing

MECHANICALLY ATTACHED TPO SYSTEM SPECIFICATION RhinoBond ATTACHMENT METHOD

Installation instructions. LORO-ATTIKASTAR siphonic drains

H series. for upper balconies DN 100. DN 100 Vers. a X X. Partial unit Side drain

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description

Roofing. Sarnacol Adhesive for Insulation Boards. Product Description. Product Data. Polyurethane-based humidity-hardening one-pack adhesive

Installation Instructions

SECTION TPO WATERPROOFING MEMBRANE FOR FLAT ROOFS INSTALATION

G October 2018

Firestone UltraPly TPO The light colored roofing choice

Roofing. Polymeric sheet for roof waterproofing. Product Description. Tests. Product Data Sheet Edition _1

Sarnavap 5000E SA Vapour Control Layer

Mounting System MCG 3.0 Membrane-Connected Glass. System description

INSTALLATION INSTRUCTIONS KÖSTER TPO

Roofing. Sika-Trocal SG 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

INSTALLATION GUIDELINE. Hertalan EPDM roofing and DPC systems

University of New Hampshire Scholars' Repository

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon,

BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Two layer, EXCEL/SPOT fully adhered waterproofing system

Firestone Polyiso Boards

G October 2018

Construction. Sika-Trocal SGmA 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE

Commercial flat roofing at its best

PlyLok. Product Guide PIR and Plywood Laminate Insulation for Warm Flat Roofs.

Insulated Roof & Wall Panels Solutions. Product Data Sheet. X-Dek Multi-Span Insulated Roof Panel KS1000 XD Multi-Span

BUILT-UP ROOFING SOLUTIONS WITH RIGID INSULATION BOARDS ON PROFILED-METAL DECKS FOR NEW-BUILD AND REFURBISHMENT

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES

J41 Reinforced bitumen membrane roof coverings

LIQUID APPLIED WATERPROOF ROOF COATINGS

System isoweld TM 3000

SINGLE PLY MEMBRANE ROOF SYSTEM

COSMOFIN FG Welding Guidelines

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

METHOD STATEMENT Sika Drain-850 Geo

RAUPEX SPEED SYSTEM Installation Guide

Thermal and sound insulation OPTIMA. Innovative and extremely efficient thermal and sound insulation for the interior surfaces of external walls

Note to Specifier: Use this product for coated glass-mat faced polyisocyanurate insulation boards such as Rboard.

Terokal TK 395 The fast and reliable solution for bonding insulation materials

TORCH-FREE BITUMEN MEMBRANE DETAILING

Single-layer waterproofing membranes

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

SECTION ADHERED SINGLE PLY MEMBRANE ROOFING

Installation Applications

Unitised Curtain Wall Beaded

Sheet Metal Protective Films

SARNAWELD - INDUCTION WELDING FASTENING

Sika-Trocal C200 Adhesive. Sika-Trocal C200 is an adhesive to bond certain insulation boards on approved substrates.

Design manual

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

Thermoplastic Single Ply & Multi-Ply Roofing Systems

Cold Weather Application Considerations

Installation Specification. Preface

Architectural Wall Products Guide Specifications

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

LIQUID APPLIED WATERPROOF ROOF COATINGS

Roofing. Sarnavap 500E. Vapour control layer. Product Description. Tests. Product Data. Form. Storage

EXP. Tilux-Line 4-6 DURABASE WP 7. Tilux Quick finder 11

Insulation Adhesive The fast and reliable solution for bonding insulation materials

General Conditions for Roofing Warranties. Section 2 Specific conditions for material warranty - Roofing products Eligibility and duration

Flat roofs. Flat roof design. 2.3 Flat Roofs

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

RedLINE MOPPING INSTALLATION

Adhesive Pull Test Standard Testing Procedures

ROOFING Sika ROOF CONTROL SYSTEM

Construction. Sarnafil G Felt. Polymeric membrane for roof waterproofing. Product Description

Architectural Roof and Wall Products Guide Specifications

Single-layer waterproofing membranes

Mechanical Attachment of Separation Panels Hot Asphalt Attachment of Separation Panels

HIGH PERFORMANCE WATERPROOFING TAPE WATERPROOFING TAPE THAT PERMANENTLY BONDS AND SEALS TO ALMOST ANY SURFACE

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

The brighter way to insulate

Sample Specification for the application of De Boer Duo HT 4 Slates/F C180 Two-Layer waterproof warm roofing membrane system to concrete.

General Conditions for Roofing Warranties. Section 2 Specific conditions for material warranty - Roofing products Eligibility and duration

Tuscaloosa Police Station

PRODUCT DATA SHEET Sarnafil TS 77-18

Insulated Panels. Insulated Roof Systems. Kingspan X-dek. KS1000 XD Longspan Roofpanel. Systems. Insurer Approved

SECTION FOIL FACED POLYISOCYANURATE FOAM BOARD INSULATION. A. Rigid polyisocyanurate foam board insulation with aluminum facers.

SRP-AirOutshield ROOF Issued:

Mounting System MCG 3.0 Membrane-Connected Glass. System description

Transcription:

RhinoBond Induction Fixing System INSTALLATION INSTRUCTIONS www.hertalan.co.uk

1. Introduction These installation instructions offer Roofers and Contractors information about the material technology involved when using the HERTALAN RhinoBond induction fastening system. They support the installer in combination with practical training at our CARLISLE ACADEMY and/or directly at the construction site. Key installation steps are described in text form and illustrated with appropriate visual material. Under some circumstances, other local conditions or material combinations not described here, may affect the method of installation. Designs that vary from the installation instructions as well as special solutions therefore require prior agreement with our technical department. The information and product descriptions in this publication are based on our experience and test results and are correct to the best of our knowledge and belief. They are the basis for all of the solutions described here. Claims for compensation may not be derived from the contents of this publication. We reserve the right to make technically feasible design and structural modifications to our product range in accordance with our high standards regarding quality and continuous advancement. March 2017 2 RhinoBond Installation Instructions RhinoBond Installation Instructions 3

Contents 1. Introduction 3 2. HERTALAN RhinoBond Induction Fixing System 6 3. Principles 8 4. Design 10 4.1 Positioning of the fixing points 10 4.2 Installing HERTALAN EPDM-membranes 11 4.3 Welding preparation 12 4.4 Welding HERTALAN EPDM-membranes 13 4.5 Ideal rotation of the magnets 14 4.6 Examples of installation depths / fixing lengths 15 4.7 Applications 17 4.8 Choice of plates 17 5. General installation instructions 18 4 RhinoBond Installation Instructions RhinoBond Installation Instructions 5

2. HERTALAN RhinoBond Induction Fixing System Please read the instructions for use before using the RhinoBond induction device. Experience the new dimension of installation with the RhinoBond Induction Fixing System and our HERTALAN EASY COVER membranes. This entire system uses induction-compatible plates to secure the HERTALAN EPDM-membranes and insulation to the roof construction without having to breach the roof membrane. The RhinoBond Induction Fixing System comprises perfectly coordinated components: induction welding device, specially coated fastening plates for HERTALAN EPDM-membranes and magnetic cooling elements. RHINOBOND FASTENING PLATE INCL. SCREW RHINOBOND FASTENING PLATE TUBE FASTENING SYSTEM (TREADSAFE) PROTECTIVE PLATE FOR USE ON MELTABLE SUBSTRATES RHINOBOND INDUCTION DEVICE SET OF 6 MAGNETIC COOLING RODS 6 RhinoBond Installation Instructions RhinoBond Installation Instructions 7

3. Principles The RhinoBond induction system is used in combination with HERTALAN EASY COVER EPDMmembranes (EASY COVER FR if required). Through induction, the coating on the fastening plates is heated to around 280 C and liquefied in the process. With firm pressure on the coating, the magnetic cooling rods create a permanent bond with the HERTALAN EPDM-membranes. Unlike with seam fastenings (e.g. with EASY WELD MF), there is no penetration of the EPDM EASY COVER membranes by the fixings. The field fixing of the fastening plates distributes the wind load evenly over the membranes, unlike traditional seam fixing. This prevents any asymmetrical force impact on the fastening plates and seams. The position of the fastening plate is defined based on the wind load calculations for the property and distributed in the roof system. As a result, despite mechan ical fixing, larger membranes can be used and a clear reduction achieved in the seam proportions and seam overlap compared to conventional systems fixed in place by mechanical means. If insulating boards (new-build or subsequent insulation) are being applied, the manufacturer's specifications with regard to the fixings used must be complied with. The insulation is secured across the entire roof surface with a combination of fastening plates and special screws. Overall, fewer fixing elements are required than with the separate fixing of insulation and membranes. The RhinoBond System is not suitable for direct use on metal substrates such as foil-laminated insulating boards. Doing so interferes with the induction device's function. This problem can be prevented by first applying at least 40 mm of insulation with a suitable facing. When using the RhinoBond System on a meltable substrate, such as EPS insulation, a protective plate must be positioned between the fastening plate and the substrate. This prevents the insulation from melting when the plate heats up. For specific details on the installation process and individual on-site requirements, please contact our Technical Department. CORNERS INNER EDGES OUTER EDGES INTERIOR 8 RhinoBond Installation Instructions RhinoBond Installation Instructions 9

4. Design 4.1 POSITIONING OF THE FIXING POINTS An installation pattern is defined for the fastening plates using the wind load calculation and manufacturer's specifications for the insulation. 4.2 INSTALLING HERTALAN EPDM-MEMBRANES Once the fastening plate has been installed, the HERTALAN EPDM-membrane is positioned and unrolled. The membranes must be rolled out smooth and allowed to relax. Apply the installation pattern to the roof using, for example a chalk line. Affix the fastening plates as per the installation pattern. Remove the membranes from the packaging. Position the membranes and unroll them. The tops of the fastening plates must be clean and dry. In the case of meltable substrates, apply the protective plate together with the fastening plate. Completely unfold the membranes. 10 RhinoBond Installation Instructions RhinoBond Installation Instructions 11

4.3 WELDING PREPARATION 4.4 WELDING HERTALAN EPDM-MEMBRANES Before the HERTALAN EPDM-membrane is induction-welded to the fastening plates, the device settings (calibration) must be coordinated with the weather and environmental conditions. To do this, a series of test welds with different energy intensities should be carried out on a separate piece of HERTALAN EPDMmembrane. The results should be assessed manually and with a simple visual inspection. Position the RhinoBond induction device precisely over a fastening plate on the HERTALAN EPDM-membrane. Switch the RhinoBond induction device on. Induction causes the fastening plate to heat up to around 280 C. After 5 seconds, the device emits a beeping sound and the welding process is complete. Place the induction device on the next fastening plate and immediately position the magnetic cooling rod on the EPDM-membrane over the fastening plate that was just welded so that the HERTALAN EPDM-membrane is pressed firmly onto the molten coating. The cooling and the pressure of the magnet strengthens the bond. The magnetic cooling rods should remain on the fastening plates for at least 45 seconds. Further calibration should be carried out if the temperature changes by + / - 5 C. DOCUMENTATION Only if the device setting used is documented is it possible to prove that the weld was carried out in accordance with the installation instructions. The day, time and device setting, as well a picture of the tests, must be recorded. Repeat this process until all of the RhinoBond fastening plates are bonded with the HERTALAN EPDMmembrane. Use the entire set of 6 magnetic cooling rods for this. A schematic representation of the ideal rotation of the cooling rods can be found overleaf. 12 RhinoBond Installation Instructions RhinoBond Installation Instructions 13

4.5 IDEAL ROTATION OF THE MAGNETS 4.6 EXAMPLES OF INSTALLATION DEPTHS / FIXING LENGTHS FIXING LENGTH DEPENDING ON APPLICATION 1 2 3 4 5 6 STRUCTURE HEIGHT SHEET STEEL WOOD CONCRETE 80 mm 102 mm 127 mm 127 mm 12 11 10 9 8 7 100 mm 127 mm 127 mm 127 mm 120 mm 152 mm 152 mm 152 mm 120 mm* 125 mm 125 mm 125 mm 13 14 15 16 17 18 140 mm 178 mm 178 mm 178 mm 140 mm* 152 mm 152 mm 152 mm 160 mm 178 mm 203 mm 203 mm MOVEMENT SEQUENCE FOR OPERATOR ROTATION OF THE MAGNETS 160 mm* 178 mm 178 mm 178 mm * TreadSafe 14 RhinoBond Installation Instructions RhinoBond Installation Instructions 15

4.7 APPLICATIONS Tested and approved roof structures according to hard roof coverings compliant with DIN V ENV 1187 with EASY COVER FR / EASY COVER for RhinoBond : ROOF MEMBRANE / PRODUCT NEW BUILD / RENOVATION VAPOUR BARRIER INSULATION / SURFACE SEPARATING LAYER EASY COVER FR - 1.2-1.5 mm new build no/or at least B2 EPS/B1 glass fleece A2 plus protective plate EASY COVER FR - 1.2-1.5 mm new build no/or at least B2 mineral fibre A1 glass fleece A2 EASY COVER FR - 1.2-1.5 mm new build no/or at least B2 PIR-FA/GV/PUR EASY COVER FR - 1.2-1.5 mm new build no/or at least B2 wood glass fleece A2 EASY COVER 1.2-1.5 mm new build / renovations no/or at least B2 old bitumen roof EASY COVER 1.2-1.5 mm new build / renovations no/or at least B2 PVC 4.8 CHOICE OF PLATES INSULATION Soft insulation (e.g. mineral wool) Thermal insulation boards with compressive stress > 100 kpa Thermal insulation boards with compressive stress < 100 kpa PLATES TreadSafe plates normal plates TreadSafe plates 16 RhinoBond Installation Instructions RhinoBond Installation Instructions 17

5. General installation instructions RhinoBond induction welding can be carried out at between -10 C and +50 C. The fastening plates must be dry when the roof sheeting is unrolled. The correct setting depth of the plates is crucial for a high-quality weld. The plates must not be positioned too high or too low. They should be flush with the insulation. The screws must be set in accordance with the manufacturer's instructions with the specified installation depths. The check of the screws extraction values must be documented on site by the roofer (in the case of renovation work, the extraction values must be determined before the wind suction calculation is performed). INSTALLATION AND DETAILING The seam connections between the roof sheeting can be established using HERTALAN KS137 and HERTALAN KS 96 or the HERTALAN EASY WELD cover strip. Membranes are fixed in place in the perimeter areas using HERTALAN KS 205 or HERTALAN KS 137. For waterproofing details, suitable pre-formed accessories should be used. Please read the general installation instructions for HERTALAN. Membrane overlaps over the fastening plates must be avoided. The permanent bond between HERTALAN EPDM-membranes and fastening plates can released again if necessary without damaging the membranes in the process. By reactivating the induction device over the fastening plates, the coating on the plates re-liquefies and the HERTALAN EPDM-membrane can be easily removed. The membrane can easily be reused with new fastening plates for a further induction weld, for example if a flat-roof replenishment is planned later. 18 RhinoBond Installation Instructions RhinoBond Installation Instructions 19

CARLISLE Construction Materials Ltd. United Kingdom Lancaster House Concorde Way Millennium Business Park Mansfield Nottinghamshire NG19 7DW T +44 (0)1623 62 72 85 F +44 (0)1623 65 27 41 E info.uk@ccm-europe.com www.ccm-europe.com RHINOBOND Installation Instructions / ENG / 2017/03