e~,5.eik REDDING, CALIFORNIA

Similar documents
SECTION 2.0 WASTEWATER TREATMENT PLANT AND DISPOSAL SYSTEM DESCRIPTION

WASTEWATER TREATMENT PLANT MASTER PLAN 6. BUSINESS CASE EVALUATION OF ALTERNATIVES

MUNICIPALITY OF WEST ELGIN RODNEY WASTEWATER TREATMENT PLANT

APPENDIX D ONSITE WASTEWATER TREATMENT TECHNICAL MEMORANDUM

Winery FAST & Floating FAST

Anderson Water Pollution Control Plant

DRIP EMITTER SYSTEM STUDY GUIDE

CITY OF LONDON ENVIRONMENTAL & ENGINEERING SERVICES WASTEWATER TREATMENT OPERATIONS DIVISION

CHAPTER 4 WASTEWATER CHARACTERISTICS WASTEWATER FLOWS

Palmer Wastewater Treatment Plant 6.7 Alternative 7: Upgrade Existing Lagoons with New Percolation Bed

RENNIA ENGINEERING DESIGN, PLLC CIVIL ENVIRONMENTAL STRUCTURAL. Report. Conceptual Wastewater Facility Plan. Olivet Center.

EVALUATION OF A WASTEWATER TREATMENT FACILITY USING A ROTATING LOW-ENERGY NON-BLOWER AERATOR

REUSE QUALITY EFFLUENT FROM RESTAURANT WASTEWATER James Bell 1, Chris Duhamel 2 and Sheryl Ervin 3

Reclaimed Waste Water for Power Plant Cooling Tower Water & Boiler Feed Make-up. Richard Coniglio, Business Product Manager

Comprehensive Plan Update - Sanitary Sewer Section Planning Commission Workshop: November 10, 2014

2017 Annual Performance Report

Appendix III. Onsite Wastewater System Feasibility Report and Plans (2012)

EVW 2 Hynds Commercial Wastewater Systems April 2013

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary

CITY OF LONDON ENVIRONMENTAL & ENGINEERING SERVICES WASTEWATER TREATMENT OPERATIONS DIVISION

Wastewater Treatment. Where does wastewater go when it leaves your house?

MUNICIPALITY OF WEST ELGIN WEST LORNE WASTEWATER TREATMENT PLANT

DISCUSSION PAPER. 1 Objective. 2 Design Flows and Loads. Capital Regional District Core Area Wastewater Management Program

Technical Memorandum No. 1

Fremont Water Pollution Control Center Plant Expansion for Nutrient Removal and Wet Weather Flow Treatment

Assuming 100 gallons per capita per day, and 3 people per REU, design flows for the development are proposed to be:

ECO Smart Aerobic Waste Water Treatment System. Optimising the re-use and recycling of waste water

Lagoons Operation and Management in New Brunswick

WASTEWATER DEPARTMENT. Bentonville Wastewater Treatment Plant Facts:

Duffin Creek Water Pollution Control Plant Technical Information

Chapter 2: Description of Treatment Facilities

CORPORATION THE EXPERIENCED LEADER IN SEQUENCING BATCH REACTOR TECHNOLOGY

APPENDIX A. 1. Background. 1.1 Existing Facilities. Page 1

Watershed Training Workshop

City of Elk River Wastewater Treatment Facility Improvements. Achieving Wastewater Treatment Goals

PRELIMINARY WASTEWATER CAPACITY STUDY

XII. APPENDIX B DECENTRALIZED MANAGED WASTEWATER SYSTEMS (DMWS) IN DETAIL

City of Redlands Wastewater Treatment Plant. Redlands, CA LOCATION: Carollo Engineers; CH2M HILL MBR MANUFACTURER: COMMENTS:

CHAPTER 1 - WASTEWATER SYSTEM DESCRIPTION

POTABLE WATER SUPPLY DEFINITIONS

Performance Evaluation of the Moores Creek Advanced Water Resource Recovery Facility

General Information on Nitrogen

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2014

Best Practice in Sewage and Effluent Treatment Technologies

Individual Residential Spray Irrigation Systems (IRSIS)

6 WASTEWATER. 6.1 Overview. 6.2 Darvill Wastewater Works

Membrane BioReactor: Technology for Waste Water Reclamation

Quilcene Wastewater Feasibility Study

VILLAGE OF ALGONQUIN 2014 WASTEWATER FACILITY PLAN UPDATE EXECUTIVE SUMMARY

Where does drinking water come from?

Wastewater Systems. By Reza Shams-Khorzani, Ph.D. VP - Bio-Microbics, Inc. 9 th KWEA/KsAWWA Annual Joint Conference August 29, 2017 Wichita, Kansas

Wastewater Facility Plan City of Marshall, Minnesota

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

Aeration Blower Requirements. Tom Jenkins 06/15/2016

1 Construction The sewage treatment plant (STP) is to be an Icon-Septech Pty Ltd Turbojet 4000 as described below and as shown on the drawings.

1 Construction The sewage treatment plant (STP) is to be an Icon-Septech Pty Ltd Turbojet 5000 as described below and as shown on the drawings.

City of Andover, Kansas Energy Assessment-Wastewater Treatment Plant

Compact Waste Water Treatment MBR /MBBR Technology

WASTEWATER TREATMENT

City of Leadwood Wastewater System Engineering Report

Watertown Wastewater Facility Plan. August 11, 2015

1/11/2016. Types and Characteristics of Microorganisms. Topic VI: Biological Treatment Processes. Learning Objectives:

Operation of a small scale MBR system for wastewater reuse

Reducing Inputs: Irrigating with Winery Wastewater Mai Ann Healy, Regional Manager - BioFiltro

AQUAROBIC AQUAROBIC MINI-PLANT TM GENERAL INFORMATION

NITROGEN REMOVAL GUIDE FOR WASTEWATER OPERATORS THE WATER PLANET COMPANY FORMS OF NITROGEN OF INTEREST TO WASTEWATER OPERATORS

Chapter 2 Screening Approach and Criteria

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2018

Mid-Halton Wastewater (Sewage) Treatment Plant Expansion And Effluent Sewer Public Information Centre # 1 May 14, 2009

Akiki Engineering Est.

American Water College 2010

Waste water treatment

We Know Water. NEOSEP Membrane Bioreactor (MBR) WATER TECHNOLOGIES

Fusion Series Treatment Systems Small Scale Residential & Commercial Treatment Units

Turbo4bio System For the Treatment of Sewage & Organic Effluents

Wastewater Treatment clarifier

Operation and Control of Multiple BNR Processes in One WWTP

Sanitary Sewer Systems. Sewage Collection System. Types of Sewage 10/12/2016. General Overview

Membrane Bioreactor vs. Extended Aeration Treatment Pilot Study Effluent and Groundwater Quality Presenter Leslie Dumas

2015 HDR, Inc., all rights reserved.

FINAL. WASTEWATER TREATMENT & COLLECTION SYSTEM FEASIBILITY STUDY for the TOWN OF PARADISE DOWNTOWN COMMUNITY CLUSTER SYSTEM

EXECUTIVE SUMMARY A. INTRODUCTION B. FINDINGS AND CONCLUSIONS. 1. Conveyance System

TOWN OF LONDONDERRY, NEW HAMPSHIRE WASTEWATER FACILITIES PLAN UPDATE TABLE OF CONTENTS

Lowering The Total Cost Of Operation

1 Construction The sewage treatment plant (STP) is to be an Icon-Septech Pty Ltd Turbojet 2000 as described below and as shown on the drawings.

Biological Treatment of Wastewater

2017 Annual Performance Report

BRACEBRIDGE WASTEWATER TREATMENT

WATER AND WASTEWATER FACILITY CLASSIFICATION APPLICATION FORM

DRAFT SUBMITTED TO: TOWNSHIP OF LONG HILL PREPARED BY: KLEINFELDER

Course: Wastewater Management

TAMING TIGERS AND WRESTLING ANACONDAS: PENDER COUNTY COMMERCE PARK WWTP

Unit 1 - Alternate Peat Based Systems In Pennsylvania Unit 2 - Alternate Peat Based System Option 1 Unit 3 - Alternate Peat Based System Option 2

Soil Physical Properties and Wastewater Treatment

Thornton Sewer Plant Operations Manual -DRAFT-

WWTF Capacity Assessment Project

Water Recycling Facility Project

Appendix 5. Wastewater Treatment Report/Water Facilities Report

OPTIMIZATION OF AN INTERMITTENTLY AERATED AND FED SUBMERGED MEMBRANE BIOREACTOR

Wastewater Terms for Permit Applications

Transcription:

e~,5.eik REDDING, CALIFORNIA Memorandum TO: Brian Huffaker, Director of Development Services DATE: January 20,2009 Hawkins Companies.~ FROM: Paul Reuter, Managing Engineer JOB NO.: 2031.01 SUBJECT: UPDATED Water and Wastewater Facilities Narrative - Knighton Road Development (Replaces the February 21, 2008 Memorandum) WATER SYSTEM REQUIREMENTS The proposed development consists of a mix ofmajor retail, general retail, shops, and sit down and fast food restaurants. It is estimated there will be approximately five acres of landscape irrigation. The attached Table 1 contains a breakdown of the proposed development and assigns water demands based on recent water consumption data from similar facilities within the Cities of Redding, Anderson and Yreka. The Maximum Daily Demand (MDD) is the flow used to design water supply facilities. As indicated in Table 1, the estimated MDD for the proposed developnlent is about 265,000 Gallons per Day (GPD) or 184 Gallons per Minute (GPM). Demands in excess of the MDD, such as during the peak hour of the day, will be provided from on-site storage. There is no municipal water system in place around the proposed development. Thus, it appears the only viable option for providing water is to develop a well. Currently, there is an existing well located on the west side ofthe site near Interstate 5. As described in the report prepared by Lawrence and Associates (L&A), dated August 20, 1998, (Well Installation Aquifer Testing and Groundwater Monitoring for the Flying J Knighton Road Travel Stop, Shasta County, California) this well has test pumped at 500 GPM for 24 hours. Thus, there appears to be ample volume to supply the proposed development. In that report, data was presented that indicated the presence of iron and/or manganese in water samples taken from this well, depending on depth of extraction. While further analysis and data collection will be required to identify the extent of these constituents, it is assumed that iron/manganese treatment will be required. Iron/manganese treatment is a common requirement in many of the wells within the Bella Vista Water District, and some City of Redding wells, located to the north-east. The well will pump water through the iron/manganese treatment system into an above-ground bolted steel water storage tank that will provide storage to accommodate demands in excess of

MEMORANDUM January 20, 2009 Hawkins Companies 2031.01 Page 2 the MDD and the required fire flow volume, see Figure 1. A small booster pump station will pump water from the storage tank to a 1O,OOO-gallon hydropneumatic tank that will maintain system pressure and provide storage for cycling the constant speed booster pump(s). The booster pump station will contain two end-suction centrifugal pumps (one active and one backup) and one fire pump, located in a small building. All pumps will be controlled based on the pressure in the hydropneumatic tank. The fire pump will be called to run when the pressure in the hydropneumatic tank falls to some level and the booster pump will not keep up. It is assumed that all commercial buildings will be equipped with fire sprinklers. The exact fire flow requirement will need to be determined based on building size and construction type. A fire flow of 2,000 GPM for 2 hours equates to 240,000 gallons of storage. Adding the requirenlent for equalizing volume (the difference between MDD and peak hourly flow) yields a tank size requirement of about 300,000 gallons. The distribution system piping will consist of a 12-inch diameter main loop through the development that will feed fire hydrants spaced in accordance with Shasta County Fire Safety Standards. Smaller water lines will be fed off the 12-inch main to serve municipal and irrigation demands. WASTEWATER SYSTEM REQUIREMENTS Since there are no municipal sewage collection and treatment facilities near the proposed development, on-site sewage treatment and disposal appears to be the only viable option. Based on winter-time water consumption quantities for similar facilities in Redding, Anderson, and Yreka, it is estimated the proposed development wastewater flows will be about 80,000 GPD during dry weather conditions. Table 2 contains a breakdown of the wastewater flow determination for the proposed project. The sewage collection system will consist of gravity sewer mains to a centrally-located submersible pump station that will convey raw sewage to the wastewater treatment facility. Wastewater Treatment: In discussions with the California Regional Water Quality Control Board (CRWQCB), they have indicated the nitrogen limit in the groundwater cannot exceed 10 milligrams per liter (mg/l) of nitrate (measured as nitrogen). However, the CRWQCB has also indicated that any treated wastewater disposal system cannot have a noticeable impact on the background nitrate levels in the area groundwater. Therefore, ifbackground nitrate levels in the groundwater are significantly below 10 PPM, it may be necessary to provide nitrate removal in the treatment process to concentrations well below 10 mg/l.

MEMORANDUM January 20, 2009 Hawkins Companies 2031.01 Page 3 In August 2008, Lawrence and Associates (L&A) performed a series of groundwater samplings from eight different shallow monitoring probes around the site; currently, L&A is monitoring the depth to water in these probes on a bi-weekly basis. The individual water samples were tested for total nitrogen, which includes nitrate. These results are included in a Technical Memorandum by L&A. Based on the analytical data, L&A estimated the wastewater should be treated to 3.0 PPM nitrate as nitrogen to avoid adverse effects to the shallowest groundwater beneath the site. In order to obtain this level of nitrogen removal, it is proposed that the wastewater treatment system incorporate a nitrification/denitrification step utilizing pre- and post-anoxic basins and Membrane Bioreactors (MBR's) for separating the permeate from the biological solids. MBR technology allows the operator to operate at higher solids concentrations in the treatment basin, which provides enhanced nitrogen removal through control of dissolved oxygen concentration in the recycle stream. The MBR treatment plant consists of a partially buried reinforced concrete basin partitioned into two separate treatment trains. Each train consists of a series oftreatment basins containing the following: Pre-Anoxic Basin: In this 6,700-gallon basin, raw sewage is mixed with return activated sludge from the MBR basin. The microorganisms in the activated sludge begin consuming the organics in the raw sewage. Pre-Aeration Basin: The pre-aeration basin is a 1O,OOO-gallon basin consisting of fine bubble diffusers which provide an oxygen supply to sustain the colony of microorganism. Post-Anoxic Basin: The 5,000-gallon post-anoxic basin provides an environment in which the microorganisms in the activated sludge are starved for oxygen creating a propensity for other oxygenated compounds to become the oxygen source for the microorganisms. For example, oxygen molecules in the compound nitrate, are consumed and nitrogen gas is released into the atmosphere. MBR Basin: The 10,700-gallon MBR basin contains submerged membrane units that separate liquid from the activated sludge. This liquid (effluent) is highly treated and meets discharge requirements for Biochemical Oxygen Demand (BOD), suspended solids and nitrate. Aerobic Digester: The aerobic digester is a four-chambered basin consisting of an anoxic basin, melubrane thickener, and two digester basins. Utilizing diffused air and MBR modules, the digester stabilizes the sludge by removing volatile organics and enhancing pathogen destruction, while reducing the volume to be disposed offsite. The effluent is then disinfected utilizing ultraviolet radiation and discharged to the effluent dosing station, which conveys treated effluent to the subsurface disposal fields at the north end of

MEMORANDUM January 20, 2009 Hawkins Companies 2031.01 Page 4 the site. At full build out, the wastewater treatment plant will be designed for the following criteria: Average Dry Weather Flow (ADWF): Peak Wet Weather Flow (PWWF): Influent Biochemical Oxygen Demand (BOD): Influent Suspended Solids (SS): Influent Total Kjeldahl Nitrogen (TKN): Effluent BOD: Effluent SS: Effluent Nitrate, as Nitrogen: 80,000 Gallons per Day (GPD) 240,000 GPD 300 mg/l 250 mg/l 60 mg/l 5mg/L 5 mg/l 3 mg/l Initially, the wastewater treatment plant will be designed for 67% of full build out capacity, or about 53,600 GPD; however, the concrete basins and infrastructure will be designed for full build out. Once flows start approaching 67% of full build out, it will be necessary to add an additional submerged MBR unit into each MBR basin. Wastewater Disposal: In February 2008, PACE performed a soils investigation ofon-site soils in order to evaluate their compatibility for subsurface disposal oftreated effluent. The investigation included excavation of 15 soils test pits and performance of 12 percolation tests at various depths in the area north of the proposed development. In general, the deeper soils (4-foot to 8-foot) consisted of gravelly sands and loanls with percolation rates in the 5 to 12 minutes per inch (MPI) range. The shallow soils (less than 2-foot) consisted of loamy soils with percolation rates between 5.3 and 40 MPI. The acceptable percolation range in Shasta County, for conventional on-site sewage disposal systems, is 5 to 60 MPI. Thus, it appears the site could accommodate on-site wastewater disposal. Wastewater disposal could consist of conventional leach trenches, or shallow drip tubes, such as the Geoflow Subsurface Drip System. However, in order to maximize the distance between the disposal trenches and the area groundwater, the shallow drip tube disposal option is recommended. However, due to the variability ofpercolation rates in the shallower soils, additional percolation tests would be necessary before final design of the subsurface drip system. There are approximately 14.6 acres available at the north end ofthe site for subsurface treated effluent disposal. According to the technical memorandum by L&A, this entire area will need to be utilized in order to provide adequate separation to area groundwater and 100% disposal field replacement area per County Standards. Although a drip disposal system would maximize the separation to groundwater, a pressurized distribution system is recommended due to the large area requirement. This type of distribution system allows for alternatively dosing a number of zonal areas. It is anticipated that up to four zones will be required at full project build out.

MEMORANDlTM January 20,2009 Hawkins Companies 2031.01 Page 5 Sludge Disposal: It is proposed that digested sludge will be removed from the aerobic digester and hauled to the Shasta County Septage Ponds once a week. Shasta County has expanded the septage ponds and has indicated it has surplus capacity to receive septage. M:\Jobs\2031.01 Knighton Road Development\Wastewater system\memo - Wastewater System Narrative 1-16-09.doc

TABLE 1 KNIGHTON ROAD COMMERCIAL DEVELOPMENT WATER SYSTEM DEMAND ESTIMATE (Updated 1 19 09) ESTIMATED WATER DEMANDS WITHOUT IRRIGATION BASED ON LOCAL AREA DATA Number of Area Average Daily Demand Max Month Maximum Daily Demand Peak Demand Use Business (sqft) (gpd/1000sqft) (gpd) (gpd/1000sqft) (gpd/1000sqft) (gpd) (gpm) (gpm) Major Retail 4 482,000 80 38,560 100 150 72,300 50 201 Retail 9 185,000 40 7,400 50 75 13,875 10 39 Shops 6 47,700 30 1,431 40 60 2,862 2 8 Restaurants (gpd/restaurant) Sit down 3 19,000 4,000 12,000 72,300 50 60 Fast food 2 7,000 3,300 6,600 13,875 10 30 TOTAL 740,700 65,991 175,212 122 337 Average Water Demand = 89 gpd/1000sqft ESTIMATED IRRIGATION WATER DEMANDS Area Annual Demand Maximum Daily Demand Peak Demand Use (Acres) Ac Ft/Ac Ac Ft/Yr (gpd/ac) (gpd) (gpm) (gpm) Landscape Irrigation 9 4 36 10,000 90,000 63 188 TOTAL 265,000 184 525 TOTAL ANNUAL WATER CONSUMPTION NON IRRIGATION IRRIGATION TOTAL 24,086,715 Gallons per year 11,736,000 Gallons per year 35,822,715 Gallons per year TOTAL PEAK DEMAND = 525 GPM DESIGN BOOSTER PUMP FOR 550 GPM DESIGN WELL FOR 200 GPM (Minimum) NOTES: 1. Landscape Irrigation done during an 8 hour period on maximum day. M:\Jobs\2031.01 Knighton Road Development\Water System\Water Demand Estimates.xls

TABLE 2 KNIGHTON ROAD COMMERCIAL DEVELOPMENT WASTEWATER ESTIMATE Number of Area Average Daily Flow Maximum Daily Flow Use Business (sqft) (gpd/1000sqft) (gpd) (gpd/1000sqft) (gpd) Major Retail 4 482,000 60 28,920 90 43,380 Retail 9 185,000 45 8,325 68 12,488 Shops 6 47,700 36 1,717 54 2,576 Restaurants (gpd/restaurant) Sit down 3 19,000 3,200 9,600 4,800 14,400 Fast food 2 7,000 2,250 4,500 3,375 6,750 TOTAL 740,700 53,062 79,593 Notes: 1. Average daily flows are based on 90% of the winter time water consumption for similar facilities in Northern California and maximum flows are estimated by multiplying the average flows by 1.5. USE 80,000 M:\Jobs\2031.01 Knighton Road Development\Wastewater system\wastewater Estimates.xls