SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Similar documents
CENTRIA FORMABOND II Metal Composite Wall System

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

CENTRIA FORMABOND. Aluminum Composite Wall System

CENTRIA Concept Series Metal Wall Panels ZINC

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

CENTRIA EcoScreen Perforated Screen Wall Panels

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

SECTION STAINLESS STEEL WALL PANELS

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

Centria Conversion SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

SPECIFICATIONS FOR. CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System. Section Aluminum Composite Panels

Architectural Wall Products Guide Specifications


SECTION PORCELAIN TILE WALL SYSTEM. (Porcelanosa Venis Urbatek)

Page 1 of 5

SECTION mm METAL COMPOSITE MATERIAL (MCM) RAINSCREEN SYSTEM SPECIFICATION

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Architectural Roof and Wall Products Guide Specifications

SECTION mm METAL COMPOSITE MATERIAL (MCM) RAINSCREEN SYSTEM SPECIFICATION

SECTION EXTERIOR GRILLS AND SCREENS

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS

SECTION EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS

Project Name Project # Project Information

Architectural Roof Products Guide Specifications

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

Corium Brick Rainscreen System Specifications

Ice Rink Renovation & New Clubhouse

Student Services & Classroom Addition

Guideline Specifications

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM

Architectural Roof Products Guide Specifications

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

EMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS

CENTRIA MetalWrap Insulated-Composite Backup Panel System

Ameriplate. Rain Screen Wall System

SECTION METAL WALL PANELS

SECTION INSULATED CORE METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

Architectural Roof and Wall Products Guide Specifications

Ameriplate. Rain Screen Wall System

SECTION METAL WALL PANEL SYSTEM

[Project Name] Section [ ]

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION METAL ROOF PANELS. A. Vertical-rib, seamed joint, standing seam metal roof panels, with related metal trim and accessories.

COLLEGE OF STATEN ISLAND

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

TRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT

COMPOSITESIDING

METAL COMPOSITE MATERIAL WALL PANELS

North Hanover Township School District North Hanover Township, New Jersey

SECTION METAL COMPOSITE MATERIAL WALL PANELS

EC-250 AAMA Pressure-Equalized Aluminum Plate Rainscreen East Coast Metal System

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

CENTRIA MetalWrap Insulated-Composite Backup Panel System with Integrated Windows and Louvers

LOG COLLEGE MIDDLE SCHOOL

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

Omniplate Barrier Wall System

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION AWNINGS

SECTION EXPANSION CONTROL

SECTION COMPOSITE WALL PANELS HIGH-PRESSURE LAMINATE EXTERIOR (COMPOSITE WALL) PANELS

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION METAL ROOF PANEL, STANDING SEAM - SRS3

CENTRIA Exposed Fastener Series Metal Wall Panels

SECTION EXPANSION CONTROL

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

Architectural Roof and Wall Products Guide Specifications

SECTION METAL FLAT LOCK TILE PANELS

SECTION EXPANSION CONTROL

SECTION METAL ROOF PANELS

SECTION STANDING SEAM METAL ROOFING

SECTION EXPANSION CONTROL

Arcwall. Rain Screen Wall System

SECTION ALUMINUM COMPOSITE WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

2004 MASTER FORMAT SECTION Façade Panels

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

TerraClad TM General Specifications

by Rollfab Metal Products

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL

Skyline Sheet Metal, Inc.: SSMXRS Pressure Equalized Rainscreen Wall Cladding System

SECTION PREHUNG WOOD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SSL-175. Specifications

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

MARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

TO THE DESIGNER. Respectfully, TFC Canopy, a Division of Centurion Industries, Inc. Bob Patterson President, TFC Canopy

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Transcription:

SECTION 07 4243 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Composite wall panel system consisting of aluminum-faced composite panels in a rainscreen application as part of the assembly described below. 1.02 PARAGRAPH BELOW DESCRIBES INSTALLATION OF METAL WALL PANELS OVER CENTRIA METALWRAP BACKUP SYSTEM. A. Metal Wall Panels over Multi-Component Framed Wall System: Aluminum-faced composite panels applied as exterior rainscreen cladding over wall framing specified in Division 05 Section "Cold-Formed Metal Framing" with exterior Foamed-in-place Closed Cell Insulation. Metal wall panel installation specified in this Section includes [secondary metal subgirt framing and] mounting clips for panel attachment. 1.03 RELATED REQUIREMENTS A. Division 07 air barrier section for transition and flashing components of building air/moisture barrier. B. Division 07 Section "Sheet Metal Flashing and Trim" for sheet metal copings, flashings, reglets and roof drainage items. C. Division 07 Section "Joint Sealants" for field-applied joint sealants. 1.04 SYSTEM DESCRIPTION A. Composite Metal Panel Wall System: Drained and back-ventilated rainscreen design consisting of dry seal joinery designed to minimize water penetration and induce air circulation in the space behind the panel system. Moisture weeping trim at panel base details allows water to drain out of the system. 1.05 REFERENCE STANDARDS A. American Architectural Manufacturer's Association (AAMA): 1. AAMA 508-07 Voluntary Test Method and Specifications for Pressure Equalized Rain Screen Wall Cladding Systems 2. AAMA 509 - Voluntary Test and Classification Method for Drained and Back Ventilated Rain Screen Wall Cladding Systems. 3. AAMA 620 - Voluntary Specification High Performance Organic Coatings on Coil Coated Architectural Aluminum. 4. AAMA 2605 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels. B. American Society of Civil Engineers (ASCE): 1. ASCE 7 - Minimum Design Loads for Buildings and Other Structures. C. ASTM International (ASTM): 1. ASTM A 653 - Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process. 2. ASTM B 209 - Specification for Aluminum and Aluminum Alloy Sheet and Plate. 3. ASTM C 645 - Specification for Nonstructural Steel Framing Members. 07 4243-1 of 07 4243-7

4. ASTM D 3359 - Standard Test Methods for Measuring Adhesion by Tape Tests. 5. ASTM E 84 - Test Methods for Surface Burning Characteristics of Building Materials. 6. ASTM E 329 - Standard Specification for Agencies Engaged in Construction Inspection and/or Testing. D. National Fire Protection Association (NFPA): 1. NFPA 285 - Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components. 1.06 PERFORMANCE REQUIREMENTS A. General: Provide composite wall panel system meeting performance requirements as determined by application of specified tests by a qualified testing agency on manufacturer's standard assemblies. B. Structural Performance: Design composite wall panel system fabricated to withstand effects of indicated loads and stresses within limits and under conditions indicated below. C. Wind Loads: Determine loads based on uniform pressure, importance factor, exposure category, and basic wind speed indicated on drawings. D. Limits of Deflection: Composite wall panel system shall withstand scheduled wind pressure with the following allowable deflection: 1. Maximum allowable deflection limited to L/175 deflection of panel head and sill normal to plane of wall. 2. Maximum allowable deflection of panel stiffeners and aluminum panel material combined limited to L/60. E. System Performance: A third party test report utilizing the standard ASTM E 283, E 331 and AAMA 501 procedures following the test protocol described in AAMA 508-07 must be submitted prior to bid. Test panel must include a horizontal joint, with an imperfect air barrier. F. Drained and Back Ventilated Rain Screen Performance: Per AAMA 509-09: 1. Water penetration through panel system: W1 classification. 2. Ventilation: V4 classification. G. Air/Moisture Barrier: Refer to Division 07 air barrier section. H. Thermal Movements: Allow for thermal movements from variations in both ambient and internal temperatures. Accommodate movement of support structure caused by thermal expansion and contraction. I. Wall systems that incorporate foam plastic insulation must be tested by the foam plastic supplier in accordance with NFPA-285. 1.07 QUALITY ASSURANCE A. Manufacturer Qualifications: Approved manufacturer listed in this Section with minimum 10 years experience in manufacture of similar products in successful use in similar applications. 1. Approval of Comparable Products: Submit the following in accordance with project substitution requirements, within time allowed for substitution review: 07 4243-2 of 07 4243-7

a. Product data, including certified independent test data indicating compliance with requirements. b. Samples of each component. c. Sample submittal from similar project. d. Project references: Minimum of 5 installations not less than 5 years old, with Owner and Architect contact information. e. Sample warranty. 2. Substitutions following award of contract are not allowed except as stipulated in Division 01 General Requirements. 3. Approved manufacturers must meet separate requirements of Submittals Article. B. Wall Systems Installer Qualifications: Experienced Installer with minimum of 5 years experience with successfully completed projects of a similar nature and scope. C. Fire Performance Characteristics: Provide metal composite wall systems with the following fire-test characteristics determined by indicated test standard as applied by UL or other testing and inspection agency acceptable to authorities having jurisdiction. 1. Surface-Burning Characteristics: Provide metal composite wall system panels with the following characteristics when tested per ASTM E 84. a. Flame spread index: 25 or less. b. Smoke developed index: 450 or less. 2. Intermediate Scale Multistory Fire Test: Representative mockup tested per NFPA 285 for a complete wall system providing air, water, vapor and thermal barriers. D. Mockups: Build mockup in size and location indicated. Show details of composite wall panel system. Demonstrate methods and details of installation. Show details of gasketed return vertical joints, penetrations, doors, windows, louvers, pipe openings, inside and outside corners, top and bottom of wall, horizontal and vertical joints. 1. Approval of mockup does not relieve Contractor of responsibility to comply with all requirements of contract documents. 2. Approved mockup may become part of installation if approved by Architect. 1.08 ADMINISTRATIVE REQUIREMENTS A. Preinstallation Meeting: Conduct preinstallation meeting at site attended by Owner, Architect, manufacturer's technical representative, and other trade contractors. 1. Coordinate building framing in relation to composite wall panel system. 2. Coordinate installation of building air and water barrier behind composite wall panel system. 3. Coordinate window, door and louver, and other openings and penetrations of composite wall panel system. 1.09 ACTION SUBMITTALS A. Product Data: Manufacturer s data sheets for specified products. 07 4243-3 of 07 4243-7

B. Shop Drawings: Provide shop drawings prepared by manufacturer or manufacturer's authorized dealer. Include full elevations showing openings and penetrations. Include details of each condition of installation and attachment. Provide details at a minimum scale 1-1/2-inch per foot of all required trim and extrusions needed for a complete installation 1. Include data indicating compliance with performance requirements. 2. Indicate points of supporting structure that must coordinate with composite wall panel system installation. 1.10 INFORMATIONAL SUBMITTALS A. Product Test Reports: Indicating compliance of products with requirements, from a qualified independent testing agency. 1.11 CLOSEOUT SUBMITTALS A. Maintenance data. 1.12 DELIVERY, STORAGE, AND HANDLING A. Protect products of composite wall panel system during shipping, handling, and storage to prevent staining, denting, deterioration of components or other damage. 1. Deliver, unload, store, and erect composite wall panel system and accessory items without misshaping panels or exposing panels to surface damage from weather or construction operations. 1.13 WARRANTY A. Special Manufacturer s Warranty: On manufacturer s standard form, in which manufacturer agrees to repair or replace metal wall panel assemblies that fail in materials and workmanship within [two] years from date of Substantial Completion. PART 2 PRODUCTS 2.01 MANUFACTURERS A. Basis of Design: CENTRIA, FormaBond II Composite Wall Panel System. Provide basis of design product[, or comparable product approved by Architect prior to bid]. 1. CENTRIA Architectural Systems; Moon Township, PA 15108-2944. Tel: (800)759-7474. Tel: (412)299-8000. Fax: (412)299-8317. Email: info@centria.com <mailto:info@centria.com>. Web: www.centria.com <http://www.centria.com>. 2.02 MATERIALS A. Aluminum Sheet: Smooth surface coil-coated sheet, ASTM B209. B. Aluminum Extrusions: ASTM B 221, 3105 Aluminum. 2.03 COMPOSITE METAL PANELS A. Composite Metal Panels: Factory-formed, aluminum-faced composite panels fabricated from two sheets of 0.020 inch (0.51 mm) thick aluminum facing sheets with metal facings bonded to thermoplastic core, and rout and return joinery. 1. Thickness: [4 mm] nominal. 2. Panel Flatness: Maximum allowable distortion: 1/32 inch in 24 inches (0.794 mm in 600 mm) in any direction. 07 4243-4 of 07 4243-7

3. Panel Core: Thermo-set polymeric[, fire-retardant]. 4. Stiffeners: Manufacturer's standard stiffener as required to meet performance requirements. B. Face Sheet Surface: Smooth. C. Face Sheet Coil-Coated Finish: 1. Color: Refer to Drawings for Custom Color & Finish: A-500 & A-501. D. Unexposed Finish: Manufacturer's standard primer. E. Exposed Trim and Fastener Finish: Match panel finish. 2.04 SECONDARY METAL FRAMING A. Miscellaneous Framing Components, General: Cold-formed metallic-coated steel sheet, ASTM C 645, Grade 50, with ASTM A 653/A 653M, G90 (Z180) hot-dip galvanized zinc coating. 1. Hat Channels: 0.053 inch/16 ga. (1.34 mm) minimum. 2. Sill Channels: 0.053 inch/16 ga. (1.34 mm) minimum. 3. Z-Furring 2.05 ACCESSORIES A. Provide manufacturer's factory-formed clips, shims, flashings, sealants, and tapes for a complete installation. B. Extruded Trim: Aluminum, minimum thickness 0.060 inch (1.59 mm) for trim and 0.90 inch (2.38 mm) for structural units. Include manufacturer-provided extruded trim for the following locations and as indicated on Drawings: 1. Base trim. 2. Coping. 3. Panel installation perimeter. 4. Opening perimeters. C. Splines: Match panel material and finish. D. Gaskets: Panel manufacturer's EPDM or neoprene, fire-retardant-treated. E. Sealants: Type recommended by composite wall panel system manufacturer for application, meeting requirements of Division 07 Section "Joint Sealants." F. Flashing Tape: 4 inch (102 mm) wide self-adhering butyl flashing tape. 2.06 FABRICATION A. General: Fabricate composite wall panels and accessories at factory identical to tested units using manufacturer's standard procedures and processes necessary to meet performance requirements. 1. Provide components of composite wall panel system that are products of one manufacturer, including composite panels, gaskets, head and sill trim, bottom weep, base extrusion, and metal copings. B. Composite Panels: Fabricate composite wall panels with extruded aluminum stiffeners requiring no further fabrication or modification in field. 1. Horizontal Joints: Dry seal, drained and back ventilated. 2. Vertical Joints: Pre-formed returns with metal spline and aluminum extrusion receptors and extruded drain channels. 3. Reveals: 0.50 inch (12 mm). 4. Formed Panel Thickness: 2.50 inch (63.5 mm). 07 4243-5 of 07 4243-7

PART 3 EXECUTION 3.01 INSPECTION A. Examine composite wall panel system substrate with Installer present. Inspect for erection tolerances and other conditions that would adversely affect installation of composite wall panel system. 1. Inspect framing that will support composite wall panel system to determine if support components are installed as indicated on approved shop drawings and are within tolerances acceptable to composite wall panel system manufacturer. a. Maximum deviations acceptable to composite wall panel system manufacturer: 1) 1/4-inch in 20 feet (6.4 mm in 6 m) vertically or horizontally from face plane of framing. 2) 1/2-inch (12.7 mm) maximum deviation from flat substrate on any building elevation. 3) 1/8-inch in 5 feet (3.2 mm in 1.5 m). 2. Confirm presence of acceptable framing members to match installation requirements of composite wall panel system. a. Confirm framing minimum.053 inch/16 ga (1.34 mm) at maximum 24 inch (610 mm) spacing. 3. Verify that window, door, louver and other penetrations match layout on shop drawings. B. Correct out-of-tolerance work and other deficient conditions prior to proceeding with composite wall panel system installation. 3.02 COMPOSITE WALL PANEL SYSTEM INSTALLATION A. General: Install composite wall panel system in accordance with approved shop drawings and manufacturer's recommendations. B. Installation: Attach panels to metal framing using recommended clips, screws, fasteners, sealants, and adhesives indicated on approved shop drawings. 1. Horizontal Joinery: Working from base of installation to top, connect upper panel to lower panel at dry seal joinery utilizing field-applied attachment clip. 2. Vertical Joinery: Provide reveal between vertical ends of panels as shown on shop drawings using hardware furnished by manufacturer. C. Install splines where indicated. 1. Galvanic Action: Where elements of metal composite wall system will come into contact with dissimilar materials, treat faces and edges in contact with dissimilar materials as recommended by manufacturer. D. Rainscreen Installation: Proceed with installation of manufacturer's dry seal horizontal joinery. Keep open spaces in horizontal joinery intended to ventilate cavity behind system. 3.03 FIELD QUALITY CONTROL A. Manufacturer's Field Service: Engage a service representative authorized by metal wall panel manufacturer to inspect completed installation. Submit written report. Correct deficiencies noted in report. 07 4243-6 of 07 4243-7

3.04 CLEANING AND PROTECTION A. Remove temporary protective films within 2 weeks of erection. Clean finished surfaces as recommended by metal wall panel manufacturer. Clear weep holes and drainage channels of obstructions, dirt, and sealant. Maintain in a clean condition during construction. B. Replace damaged panels and accessories that cannot be repaired by field repair. END OF SECTION 07 4243-7 of 07 4243-7