Single Component 100% Silicone Sealant INSTALLATION INSTRUCTIONS

Similar documents
VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS

VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS

RevealShield SA Penetrations

WrapShield SA Brick Tie Penetration

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

ZIP System Liquid Flash

SLOPE. HIELD SA SELF-ADHERED Vapor Permeable Roof Underlayment INSTALLATION INSTRUCTIONS

Perm-A-Barrier VPS (Vapor Permeable Sheet)

Blue Barrier Flash N Wrap 2400

Installation Guidelines for all Quaker products with nail fins New construction nail fin installation with a drainable weather resistant barrier.

Installation Guide Sto RapidGuard

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

SuperiorFlash. masterwall.com PO Box 397 Fortson GA Tech:

WeatherSmart Air Barrier Installation Guide

AquaFlash System Installation Guide DS196

VaproFlashing PRODUCT DATA SHEET

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

3. Aesthetic Groove. 5. Window Head (Flush) 6. Window Head (Recessed) 7. Window Jamb Detail (Flush) 8. Window Jamb Detail (Recessed)

AquaFlash System Installation Guide

Perm-A-Barrier NPS (Non Permeable Sheet)

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

SECTION WATER-RESISTIVE AIR BARRIER MEMBRANE

DOWSIL Silicone Transition System: Application Guide Build a Better Barrier

Acrocrete Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

R Guard AIR & WATER BARRIER. FastFlash

Product and System Specifications DuPont Flashing Systems

Finestone Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

A. Section includes fluid applied, vapor permeable membrane air barriers.

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details

PART 2 - AIR BARRIERS SELF-ADHESIVE

Acrocrete Platinum CI Stucco Ultra Typical details for a premium impact and puncture resistant rain screen design cement plaster stucco system

Senturion TM III Wall System

SECTION SELF-ADHERING WATER-RESISTIVE AIR BARRIER MEMBRANE

StoGuard Air Barrier Installation Manual

Joint & Seam Filler. R Guard. REGULATORY COMPLIANCE VOC Compliance

SRP-AirOutshield UV Issued:

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

Installation Guide Single-Hung, Picture & Shapes Non-Impact & Impact Resistant Florida Flange Windows

SECTION SELF-ADHERING WATER-RESISTIVE AIR BARRIER MEMBRANE

PERM-A-BARRIER VPS. Product Description. Product Data Sheets. Self-adhering vapor permeable air and water barrier membrane

PART 1 - GENERAL PROJECT NAME SECTION VAPOR PERMEABLE AIR BARRIER

DuPont Tyvek Wall Underlay Install Guide

Commercial Flashing Details

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

WeatherMaster ULTIMATE MP Sealant

Triton WP Waterproof Membrane

PERM-A-BARRIER NPS Detail Membrane

PROTECTO DECK INSTALLATION INSTRUCTIONS

Senturion TM I Wall System

IVC US. Light Commercial Installation Guide - Sheet Vinyl. Leading the Way

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2

Triton DCI Decoupling Mat

SECTION WATER-RESISTIVE AIR BARRIER MEMBRANE

Wabo FireShield Model: FSH

INSTALLATION INSTRUCTIONS

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

Guide Specification for the OSI QUAD Window and Door Flashing System

Impression Graphic panels

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

Securock ExoAir 430 System Installation

DOWSIL 123 Silicone Seal

Weep Valves Stucco Wire Mesh Reinforcement Weather Resistive Barrier Sheathing Insulation Framing

Sentry Stucco Ultra Wall System

GE Enduris* 3500 silicone roof coating Roof Restoration Warranty - 10 Year

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

DuPont Flashing Systems Commercial Installation Guidelines

WELCOME. Recommended Window Installation. 1 credit Minnesota Department of Labor and Industry

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

excom (Expressed Panel Facade System) Primary top hat 160 x 35 x 1.0mm mm.

MirroFlex Tub and Shower Walls Kit Installation Instructions

BEP Blue Barrier Installation and Application Guide

Installation Guidelines for Sealing PTAC Sleeves

GCP APPLIED TECHNOLOGIES PERM-A-BARRIER VPL 50

Senershield -R / Senershield -VB

BACKSTOP NT - Texture A high performance, non-cementitious water-resistive membrane and air barrier. Backstop NT - Texture Application Instructions

Installation Instructions

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

Tensile ASTM D1970 MD = 939 psi / CD = 1252 psi Self Sealability / water penetration resistance around nails. ASTM D1970 Section 7.

DOWSIL Neutral Plus Silicone Sealant

1-part polyurethane sealant for building joints

Window Installation Instructions Fixed Systems with Subframes

Application Guidelines for PPC Coatings Flooring

Adhesion Promoter/Primer 3M Adhesion Promoter AP596

A. The work of this section includes, but is not limited to, the following:

Commercial Resilient Sheet Flooring

BACKSTOP NT - VB A high performance, non-cementitious water-resistive membrane and air/vapour barrier

ERSYSTEM ONESTEP PLUS

3M Plastic Primer P591. Color Clear Black Black Clear Black Clear. (Ford Cup) Solids (%) VOC (g/l)

838 Coatings System Specification Single-Ply Restoration (838 SPR)

2019 IAQA Annual Meeting

PAYING ATTENTION TO DETAIL by Bob Cusumano

Thin Architectural Splitface Block Veneer Specification Guide

Chemical & Hydrocarbon Resistant Membrane 0.00E E E E E E E E+03

Contents. ZIP System R-Sheathing

Transcription:

OVERVIEW VaproBond is a single component 100% silicone sealant designed to function as an adhesive sealant and an allweather silicone liquid flashing material. APPLICATION VaproBond is appropriate for above-grade applications to concrete, masonry, natural stone, structural sheathing, architectural metal panels, painted metals, glass, PVC, FRP, EPDM, all VaproShield WRB/Air Barrier membranes, and most other building materials. TECHNICAL DATA Approved for use as a flashing material with metal framing systems. Not recommended for wood applications. VaproShield recommends VaproLiqui-Flash with wood applications. Usable over a wide temperature range. -50 to 300 F (-45 to 149 C) Cured service temperatures: -50 to 300 F (-45 to 149 C) Excellent weatherability, UV stable for extended exposure Remains flexible under extreme temperatures Compatible with an extensive list of materials from various manufacturers, view list at http://vaproshield.com/ technical-resources/testing/sealant-compatibility COVERAGE VaproBond is available in 20 fl oz (592 g/ml) sausages Sealant Flashing ¼ (6 mm) bead will adhere 125 ft. (38 m) of overlapping membrane 30-45 wet mils (0.76 1.14 mm) covers 6-8 ft 2 (0.56-0.74 m 2 ) Not recommended for wood applications. EQUIPMENT Apply using a professional caulking gun. Use a DRY joint knife, trowel, or spatula to spread. Do not use soapy water or alcohol when tooling or spreading. STORAGE Store VaproBond unopened sausages at temperatures lower than 80 F (27 C). Do not open sausage until preparation work has been completed. Do not alter or mix with other chemicals. When stored at or below 80 F (27 C) VaproBond has a shelf life of 12 months after the date of manufacture. Do not double stack pallets. Dispose of unused product and container in accordance with local, state and federal regulations. CLEANUP Immediately remove all excess VaproBond in undesired areas with mineral spirits. Clean tools and equipment with mineral spirits or similar solvent immediately after use. Observe all manufacture s safety precautions. Remove cured VaproBond using a sharp-edged tool. Page 1 of 5

BEST PRACTICE INSTALLATION ROUGH OPENING SEQUENCE FOR VAPROBOND 1. Install VaproFlashing SA Self- Adhered (orange) or RevealFlashing SA (black) into sill with 2.75 (70 mm) folded into Rough Opening (R.O.) 9 (229 mm) left on face, with bottom 6 (152 mm) of release film to remain 2. Install jamb pieces with 2.75 (70 mm) folded into R.O. 9 (229 mm) to be left on face. 3. Install head piece with 2.75 (70 mm) folded into R.O. 9 (229 mm) to be left on face. Roll all VaproFlashing SA (orange) or RevealFlashing SA (black) sections with weighted roller to ensure full contact. 4. Using the sausage gun, apply VaproBond in a zigzag pattern on the wall face surrounding the rough opening. 5. Immediately spread the applied material with a putty knife creating a 1 (25 mm) border around the rough opening. 6. Apply additional VaproBond in zigzag pattern on all inner surfaces of the rough opening. 7. Immediately spread until all surfaces are completely covered and substrate below is no longer visible (approximately 30-45 wet mils (0.76-1.14mm)). 8. Allow VaproBond to set, then inspect for voids and apply additional VaproBond as needed to achieve complete coverage. RO is now ready for window and head flashing installation (by others). Page 2 of 5

SEALANT BETWEEN MEMBRANE Overlap vertical seams by 12 (305 mm) minimum. Apply VaproBond adhesive sealant bead just below Integrated Tape line at the vertical seam joint. Use hand roller to seal the seam for an air and water tight seal. TEAR AND ABRASION REPAIR Typical installation tears or abrasions Remove excess membrane from tear until smooth with substrate. Cut and apply a patch of self-adhered field membrane or VaproFlashing SA Self-Adhered, remove release film, smooth over with hand pressure. Hole Patch Repair: seal the reverse lap (at top) with VaproBond to ensure a water and air tight seal. Use hand roller to ensure complete adhesion. Abrasion Repair: apply VaproBond over abrasion and tool with a DRY joint knife, trowel or spatula. Page 3 of 5

REVERSE LAP SEALANT VAPROSHIELD BEST PRACTICE IS TO AVOID REVERSE LAPS BY PROPERLY SHINGLING MEMBRANE AND ROUGH OPENING FLASHING. Sealing Reverse Lap Apply 3/8 (9.5mm) minimum bead line of VaproBond to the reverse lapped membrane. Use a DRY joint knife or trowel to tool VaproBond to shed water. OTHER TYPICAL SEALANT USES Head flashing (by others) embedded in VaproBond over cured VaproBond VaproSilicone Transition sheet installed with VaproBond. Headflashing sealant Sealing VaproSilicone Transition Materials Flanges and fasteners should be completely covered with VaproBond Min. 2 (51 mm) on face, min. 1 (25 mm) out along all sides of penetration Sealant joint tooled onto backer rod between window and rough opening. Note: Sealant joint depth should be 1 /2 (13 mm) of width Backer rod installed around entire edge of window, filling gap between rough opening and window edge Penetration Sealant VaproBond inside rough opening and 1 (25 mm) on face. Interior Air Seal VaproBond tooled over vertical seam VaproBond tooled over vertical seam Floor Line Movement Joints Outward Inward Page 4 of 5

Call VaproShield Technical Department, 1.866.731.7663 for further clarification. Job #: Purchase Date: Installation Date: Project Name: PRODUCT: A) PRODUCTS TO WHICH WARRANTY APPLIES: 1). WALLSHIELD IT 2). WRAPSHIELD IT 3). WRAPSHIELD SA SELF-ADHERED 4). WRAPSHIELD RS 5). REVEALSHIELD IT 6). REVEALSHIELD SA SELF-ADHERED 7). SLOPESHIELD IT 8). SLOPESHIELD SA SELF-ADHERED 9). VAPROMAT 10). VAPROFLASHING 11). VAPROFLASHING SA 12). REVEALFLASHING 13). REVEALFLASHING SA SELF-ADHERED 14). VAPROFLASHING Factory Formed Corners 15). VAPROLIQUI-FLASH 16). VAPROBOND B) LIMITED WARRANTY: The WallShield IT, WrapShield IT, WrapShield SA, WrapShield RS, RevealShield IT, RevealShield SA, SlopeShield IT, SlopeShield SA and VAPROMAT products are suited for their intended use as an underlayment, weather resistive barrier, or as an air barrier. VaproShield will warrant its products for a period of twenty (20) years from the date of purchase. VaproShield will replace any faulty product, provided the product used is installed per the published installation instructions and details. VaproShield installation instructions are provided with the products and/or are available at www.vaproshield.com, or by calling VaproShield toll free at 1-866-731-7663. This warranty is transferable upon sale of the project, but in no event does it extend beyond 20 years from the date of original purchase of the product. Any and all claims must be made in writing within 20 business days after the owner discovers or obtains knowledge of any VaproShield LLC 20-Year Product Warranty Owner Name: Installer Name Date Issued: LIMITED PRODUCT WARRANTY AND DISCLAIMER*: defect in the product(s). VaproShield must be given reasonable opportunity to inspect the allegedly defective product and all damage prior to alteration or removal of the product or any surrounding building components. All claims must be made in accordance with the claims and inspection procedure noted herein. This warranty shall not apply to, and VaproShield shall not be liable for, any damages arising in whole or in part from any one or more of the following: 1) WallShield IT, WrapShield IT, WrapShield SA, WrapShield RS, RevealShield IT, RevealShield SA, SlopeShield IT, SlopeShield SA and VAPROMAT that is not stored or installed in accordance with VaproShield s installation instructions in effect at the time of the installation. 2) Improper building practices or design not in accordance with the applicable building code or industry standards, or any deviation from approved construction plans or specifications. 3) Damage to WallShield IT, WrapShield IT, WrapShield SA, WrapShield RS, RevealShield IT, RevealShield SA, SlopeShield IT, SlopeShield SA and VAPROMAT resulting from causes other than normal weather conditions, including impact of falling objects, Acts of God, earthquakes, hurricanes, flood, fire, hailstorms, high winds, cascading roof/floor water, ponding water, immersion in water, or improper installation of any building component. 4) Defects in the structure or a component of the structure (e.g., window, door, or wall system), premature deterioration of the building materials, or non-standard use of the VaproShield products. 5). Contamination of membrane with building site chemicals including, but not limited to, surfactants or substances that adversely affects its water resistance. OPEN JOINT APPLICATIONS: VaproShield will warrant material for any open jointed cladding systems when VaproShield s Best Practices, details, and installation instructions (in effect at the time of the installation) are followed. C) DISCLAIMER: This warranty is limited to product replacement. This warranty is the sole warranty and is being provided in lieu of any other warranties, whether express or implied. Neither VaproShield LLC nor any of its affiliated companies, including product manufacturers, suppliers, representatives or distributors shall be liable for labor costs, consequential damages (such as personal injuries or damage to property) of any kind, loss of profits, loss of use, or any other damage or injury, whether known or unknown, that is caused or alleged to have been caused in whole or in part by any VaproShield product. Any deviation from VaproShield s published Best Practices, details, and installation instructions (in effect at the time of the installation) shall void this warranty as to the entire project, unless such deviation was pursuant to a written directive or approval by VaproShield s Technical Team. Under no circumstances is a product sales representative, or any other individual or entity, authorized by VaproShield to direct or approve any VaproShield product installation, including but not limited to any deviation from VaproShield s published Best Practices, details, and installation instructions. This Warranty is not valid unless and until VaproShield product has been paid for in full. Page 5 of 5