Preliminary evaluation of NaClO 2 powder injection method for mercury oxidation: Bench scale experiment using iron-ore sintering flue gas

Similar documents
Sorbents Evaluation Testing Facilities. 95% removal efficiency or an emission standard of lbs/gw h by 2012, while

Hydrogen Sulphide and Mercaptan Removal

A novel method for NOx and Hg emission control in power plants using existing wet limestone scrubbers

Physical, Chemical and Electrical Analysis of Dust Generated from Cement Plants for Dust Removal with an Electrostatic Precipitator

D DAVID PUBLISHING. Mechanism Research of Hg 0 Oxidation by Pulse Corona Induced Plasma Chemical Process. 1. Introduction

Proceedings of the 22 nd Annual International Pittsburgh Coal Conference Paper 5-1 Pittsburgh, PA September 12-15, 2005

WHITE PLUME REMOVAL USING FUEL ADDITIVES IN THERMAL POWER PLANTS

Gas Suspension Absorber

Continuous Mercury Monitoring at Cement Plant

Chemkin Simulation of Mercury Oxidation in a Condensing Heat Exchanger

Performance Review of CASTOR Pilot Plant at Esbjerg

Development of Mercury and SO3 Control Technology using Gas Gas Heater

Analysis of micro-leak sodium-water reaction phenomena in a sodium-cooled fast reactor steam generator

pilot plant for CO 2 capture in Esbjerg

MERCURY CONTROL WITH FABRIC FILTERS FROM COAL-FIRED BOILERS

Effect of the Chlorine Type, Concentration and the Adding Mode on the Mercury Transformation in. Coal-Fired Flue Gas

TruePeak TDLS200. NH 3 Slip Measurement. <Document Number> Copyright Yokogawa Electric Corporation <date/time>

Fabrication and performance of fl y ash granule fi lter for trapping gaseous cesium

Removal of Elemental Mercury from Flue Gas by V 2 O 5 /TiO 2 Catalysts Dispersed on Mesoporous Silica

MerSim TM Mercury Model. Abstract. Introduction. Mercury Control Strategies

Dust Recycling System by the Rotary Hearth Furnace

Purification of Oxyfuel- Derived CO 2

Mercury Oxidation Across SCR Catalyst at LG&E s Trimble County Unit 1

Purification of Oxyfuel- Derived CO 2. Vince White Air Products PLC, UK 5 th March 2008

Overview of Speciated Mercury at Anthropogenic Emission Sources

Biofuels GS 2 Measuring Course Part II, DTU, Feb 2 6, 2009 Experiments in the entrained flow reactor

Evaluation of Mercury Control Strategies in the Presence of SO 3 Using the MerSim TM Model. Brydger Van Otten, Bradley Adams

A Review of Sulfide Smelting Process Gas Handling Systems

Development of Air Pollutants Treatment System for Industrial Processes using Petroleum Coke

Verification of Microfine Lime Theoretical Model for SO 2 Removal in Precalciner Cement Plants

Absorption of SO 2 using PVDF hollow fiber membranes with PEG as an additive

Methods for determination of mercury in LP gas

Hydrogen production by catalytic decomposition of methane over carbon catalysts in a fluidized bed

FOR GOOD RTO OPERATION, KNOW YOUR INPUTS

Evaporative Gas Cooling and Emissions Control Solutions

Questions. Downdraft biomass gasifier. Air. Air. Blower. Air. Syngas line Filter VFD. Gas analyzer(s) (vent)

Acid Gas Control Systems. Spray-Dry Scrubbers and Dry Injection Systems. United McGill products. a McGill AirClean product

Particulate CEMs for Wet and Dry FGD applications. By William Averdieck, Managing Director, PCME Ltd, UK

by: Steven M. Puricelli and Ernesto Vera-Castaneda MECS, Inc USA

Yi-Shiu Jen 1, Chung-Shin Yuan 1, Yuan-Chung Lin 1, Chang-Gai Lee 2. Institute of Environmental Engineering, National Sun Yat-sen University 2

Advanced AQCS for Oxy-fuel Combustion System; Controlling Mercury & SO3

Research Article Investigation on Mercury Reemission from Limestone-Gypsum Wet Flue Gas Desulfurization Slurry

Air Pollution Control For

Effect of Fuel Particle Size on Emissions and Performance of Fluidized Bed Combustor

CEMENT PLANT ENVIRONMENTAL TECHNOLOGY FOR ACHIEVING HIGH SO 2 REMOVAL

Mercury emission from anthropogenic sources from Guizhou province, China, in 2006

Hot Gas Filters for Control of Emissions to Atmosphere

Simultaneous removal of SO 2, NO and particulate by pilot-scale scrubber system

The effects of carbon-in-ash on mercury capture from. flue gas

Effect of catalyst to oil weight ratio on gaseous product distribution during heavy oil catalytic pyrolysis

NO x and SO x Simultaneous Removal from Exhaust Gas in a Glass Melting Furnace Using a Combined Ozone Injection and Chemical Hybrid Process

Application of CFB (Circulating Fluidized Bed) to Sewage Sludge Incinerator

Releasing behavior of mercury in coal during mild thermal treatment

Fluid Bed Scrubbing TECHNOLOGY

TECHNICAL PUBLICATION

MERCURY IN THE CEMENT INDUSTRY

Catalytic Activated Ceramic Dust Filter a new technology for combined removal of dust, NOx, dioxin, VOCs and acids from off gases.

LATEST DEVELOPMENTS OF THE PLASMA-ENHANCED ELECTROSTATIC PRECIPITATOR FOR MERCURY REMOVAL IN COAL-FIRED BOILER FLUE GAS

A Study on the de-nox Activity of V2O5-Sb2O3/TiO2 SCR Catalyst at Low Temperature According to the Wash Coating Conditions

PPC specializes in maximum efficiency air pollution control equipment using a variety of different

Ms.P.Aileen Sonia Dhas

Development of Technology for Advanced Utilization of Hydrogen from By-product Gas of Steelmaking Process

Chapter 10 Material Balances for Processes Involving Reaction 10.1 Species Material Balances Processes Involving a Single Reaction

The effect of noncondensable gas on heat transfer in the preheater of the sewage sludge drying system

A study of the improvement in dewatering behavior of wastewater sludge through the addition of fly ash

Mercury Emissions Control in Coal Combustion Systems Using Potassium Iodide: Bench-Scale and Pilot-Scale Studies

Preparation of Ultra-fine Alumina Powders by D. C. Plasma Jet

Design, Construction, and Commissioning of a Pilot-Scale Dual Fluidized Bed System for CO 2 Capture

Pyrometallurgy of iron is still the most important pyrometallurgical process economically.

Optimizing Absorber STEP 2 - FGDplus Working principle for DeSOx

Simulation of a Fluidized Bed Spray Granulation Pilot Plant GF/ProCell 25 with the Flowsheet-Simulation Software SolidSim

Module 4 : Hydrogen gas. Lecture 29 : Hydrogen gas

THE HOT GAS DESULFURIZATION IN A COMPACT TWO BEDS SYSTEM INTEGRATED WITH COAL GASIFICATION AND FISHER-TROPSCH SYSTEM

Air Quality Measurement Methods. Tim Morphy Regional Manager Thermo Electron October 20 th, 2006

Overall, about one-third of airborne mercury

Worldwide Pollution Control Association

Duke Energy Seminar September 3 5, 2008 Concord, NC

Worldwide Pollution Control Association. August 3-4, 2010

A comparison of spontaneous combustion susceptibility of coal according to its rank

Chlorine promotes antimony volatilization in municipal waste incineration

Robust flue gas probes for industrial emissions measurements.

RETROFIT IMPACTS OF OXY-COAL COMBUSTION OF PRB COAL ON DEPOSIT FORMATION AND MERCURY SPECIATION. Jost O.L. Wendt and Geoffrey D Silcox

Determination of the Ethylene Oxide Control Efficiency from Catalytic Oxidizers. A Guidance Document

Enhanced Dust Collector Performance Evaporative Gas Conditioning

Effect of Moisture Conditioning and Handling on Leaching and Physical Properties of Sodium Bicarbonate Flue Gas Desulfurization Materials

Method Development for Direct Analysis of Mercury by Thermal Decomposition. David L. Pfeil

Static Mixing, Reaction, Heat Transfer & Fluid Dynamics Technology

Manganese removal using an aerated granular filter

The Cost of Mercury Removal in an IGCC Plant

POINT SOURCES OF POLLUTION: LOCAL EFFECTS AND IT S CONTROL Vol. II - Clean Coal Technologies - Bingjiang Liu

WOOD PELLETS- A GROWING MARKETPLACE

AQCS (Air Quality Control System) for Thermal Power Plants Capable of Responding to Wide Range of Coal Properties and Regulations

Catalytic coal partial gasification in an atmospheric fluidized bed

EERC. June 21, Dear Dr. Berndt:

Keywords: Reformer model; Preferential oxidation; Water-gas shift reaction

METHOD #: Approved for NPDES and SDWA (Issued 1974) Mercury (Automated Cold Vapor Technique) ANALYTE: CAS # Hg Mercury

Membrane-Based Wet Electrostatic Precipitation

The WTA technology An advanced method of processing and drying lignite

DIOXINS AND THE CEMENT INDUSTRY IN AUSTRALIA

Lesson 5. Industrial Applications of ESPs. Goal. Objectives. Introduction. Boilers. Particulate Matter Control System

Transcription:

Korean J. Chem. Eng., 28(3), 808-812 (2011) DOI: 10.1007/s11814-010-0433-y INVITED REVIEW PAPER Preliminary evaluation of NaClO 2 powder injection method for mercury oxidation: Bench scale experiment using iron-ore sintering flue gas Youngchul Byun, Kiman Lee, Jeonghyun Kim, Dong Jun Koh, and Dong Nam Shin Environmental Research Department, Research Institute of Industrial Science and Technology, Hyoja Dong, Pohang, Gyeoungbuk 790-600, Korea (Received 5 April 2010 accepted 15 September 2010) Abstract The injection of powdered sodium chlorite (NaClO 2 (s)) for mercury oxidation into iron-ore sintering flue gas has been evaluated by using the bench scale of tubular flow reactor, where the flow rate and temperature of flue gas stream were controlled to 250 Nm 3 hr 1 and 135 o C, respectively, and either 50 or 260 µg Nm 3 of the mercury concentration was introduced intentionally to the gas stream. We have observed that 90% of Hg 0 oxidation was obtained at 0.18 g Nm 3 NaClO 2 (s) injection, indicating that the oxidized weight of Hg 0 by the loaded weight of NaClO 2 (s) is 1026 (±333) (µg-hg 0 ) (g-naclo 2 (s)) 1. This result leads us to suggest that the simple injection of NaClO 2 (s) into the flue gas has the potential to achieve over 90% mercury control in practical application. Key words: Sodium Chlorite, Mercury, Oxidation, Real Plant, ClO INTRODUCTION To whom correspondence should be addressed. E-mail: jydnshin@rist.re.kr Mercury, as a highly toxic pollutant, tends to be bio-accumulate in the food chain with adverse effects on human health [1,2]. A large portion of anthropogenic mercury emissions comes from municipal waste combustors and coal-burning utilities [1]. Mercury emissions occur in association with particulate matter (Hg p ), gaseous elemental form (Hg 0 ), and various gaseous mercuric compounds (Hg 2+ ) [1]. Although Hg 2+ and Hg p can be effectively removed by conventional air pollution control devices such as electrostatic precipitation (ESP) and flue gas desulfurization (FGD), Hg 0 is harder to capture because of its high vapor pressure and low water solubility. Unfortunately, the vast majority of mercury is emitted in the form of Hg 0. Therefore, most studies are focused on the oxidation of Hg 0 to Hg 2+ species, such as HgO and HgCl 2, for the effective control of mercury emission. In our previous studies, we examined the oxidation of NO by using powdered sodium chlorite (NaClO 2 (s)) in laboratory scale. It was found that NO oxidizes to NO 2 by NaClO 2 (s) and in turn NO 2 reacts with NaClO 2 (s) leading to the formation of OClO, followed by the further reaction of OClO with NO to produce ClO, Cl and Cl 2 which play an important role in the oxidation of Hg 0 [3]. On the basis of such observation, we further examined whether the oxidation of Hg 0 by using NaClO 2 (s) proceeds well in the presence of NO x and, eventually, we observed that the co-benefit removal of mercury by using NaClO 2 (s) in the presence of NO x is possible [4]. However, our previous study focused on only the detailed mechanism behind the oxidation of Hg 0 and used a packed-bed reactor containing NaClO 2 (s) within N 2 balance, instead of the flow system of the real flue gas. NaClO 2 (s) has a form of powder, indicating that the direct injection of NaClO 2 (s) is more convenient way than the packed NaClO 2 (s) when we try to control mercury contained within the real flue gas. To evaluate the performance of NaClO 2 (s) injection toward mercury control, it is necessary to know the oxidized weight of Hg 0 by the loaded weight of NaClO 2 (s). Besides, the effectiveness of NaClO 2 (s) in the real flue gas must be examined because the real flue gas contains other gas components such as H 2 O, CO, CO 2, NO x, H 2 O, SO 2 and dust. Therefore, for the first time, we conducted the injection of NaClO 2 (s) to the real flue gas containing other gas components emitted from the iron-ore sintering plant of steel making works with the following objectives: (1) to confirm the possibility of oxidizing Hg 0 by the injection of NaClO 2 (s) into the real flue gas, and (2) to evaluate the oxidized weight of Hg 0 related to the loaded weight of NaClO 2 (s). EXPERIMENTAL SECTION 1. Description of the Iron-ore Sintering Plant in a Steel-making Company We installed a tubular flow reactor in an iron-ore sintering plant of steel making works. The function of a sintering plant is to pro- Table 1. Gas conditions of iron-ore sintering plant conducted the injection of NaClO 2 (s) for the oxidation of Hg 0 Flow rate 250 Nm 3 hr 1 Reactor temperature 135 o C Baseline O 2 concentration 14-16% Baseline NO concentration 180 ppm Baseline SO 2 concentration 175 ppm Baseline CO 2 concentration 2.5% Baseline CO concentration 5,850 ppm Baseline Hg 0 concentration <10 µg Nm 3 Baseline particle concentration 10 mg Nm 3 Inlet Hg 0 concentrations 50 µg Nm 3, 260 µg Nm 3 808

Mercury oxidation 809 Fig. 1. Schematic diagram of the experimental system. cess the fine grain of raw iron-ore material into coarse grained ironore before being charged to the blast furnace. The flow rate of flue gas emitted from the iron-ore sintering plant is about 1 million Nm 3 hr 1, where ESP, bag filter and selective catalytic reduction are equipped in series to control the air pollutants. We installed the tubular flow reactor in the duct between ESP and the bag filter. The experimental conditions such as gas composition, temperature and flow rate are listed in Table 1. 2. Tubular Flow Reactor and NaClO 2 (s) Injection System A schematic diagram of the tubular flow reactor is shown in Fig. 1. The flue gas of 250 Nm 3 hr 1 was taken out from the duct of the iron-ore sintering plant by using the induced blower, then introduced into the tubular flow reactor and eventually returned to the duct. The tubular flow reactor was made of steel pipe (10 cm in diameter). The linear velocity of flue gas in the tubular reactor was 885 cm s 1. An electric heater was installed between the duct and the tubular flow reactor to control the gas temperature. The temperature difference between two ends of the tubular flow reactor was controlled to be within 5 o C. Hg 0 was introduced intentionally to the tubular flow reactor by evaporating liquid mercury wrapped by heating tape in which the temperature was controlled. A screw feeder was used to inject NaClO 2 (s) into the reactor. The photograph of the experimental system used in this study is shown in Fig. 2. The screw feeder supplied NaClO 2 (s) (density=0.667 g cm 3, size=below 0.5 mm) to the reactor at a constant feeding rate, and then the released NaClO 2 (s) was naturally squeezed into the reactor by the pressure difference between the inside and outside of the tubular flow reactor. The distance between NaClO 2 (s) and mercury injection ports was separated to 15 cm. The gas sampling port for the analysis of gas composition was 300 cm away from the NaClO 2 (s) injection port. The inside volume of the tubular flow reactor and the residence time of the flue gas passing between the NaClO 2 (s) injection and the gas sampling ports were 23,550 cm 3 and 0.33 s, respectively. 3. Gas Analysis and Hg 0 Calibration Procedure A gas sample of 10 L min 1 for the analysis of gas composition was taken from the sampling port by using a peristaltic pump. The mercury concentration was determined by using cold vapor atomic absorption spectrometry (CVAAS) having two absorption cells [5]. The concentrations of gas components were monitored with a nondispersive infrared type of gas analyzer (ZKJ, Fuji Electric Systems Co.). Before the concentrations of gas components were analyzed, the water cooling section for the gas stream was positioned to remove water entering the analyzer. The mercury analyzer was calibrated with the calibration equipment (Fig. 3). The concentration of Hg 0 was controlled both by N 2 flow and by the temperature of the mercury condensation vessels. Hg 0 was vaporized within a mercury evaporation vessel and swept out by using N 2 gas passing through the vessel. The Hg 0 laden N 2 then entered a saturation vessel within a finely controlled temperature Fig. 2. Photograph of the experimental system. Fig. 3. Schematic diagram of the calibration system for Hg 0 analyzer. MFC: Mass flow controller. Korean J. Chem. Eng.(Vol. 28, No. 3)

810 Y. Byun et al. bath. The gas residence time and surface of condensation materials within the saturation vessel ensured that the gas stream of Hg 0 in N 2 was saturated with Hg 0 vapor at the controlled temperature of the saturation vessel. The temperature of Hg 0 evaporation vessel was set to ensure that the mercury content of the gas stream leaving the evaporation vessel was greater than that of the saturation concentration corresponding to the value of the saturation vessel temperature. The stream of N 2 and Hg 0 exiting the saturation vessel was diluted prior to entering to the CVAAS. In such a way, we obtained the signal of the Hg 0 concentration by using CVAAS. RESULTS AND DISCUSSION We injected NaClO 2 (s) into the tubular flow reactor containing 50 µg Nm 3 of Hg 0, where the feeding rate of NaClO 2 (s) was set to 0.06 g Nm 3 (Fig. 4). As soon as NaClO 2 (s) was introduced into the tubular flow reactor, Hg 0 was decreased suddenly to 10 µg Nm 3. In our previous study, we observed that the introduced NO reacts with NaClO 2 (s) to produce NO 2 through the following reaction: 2NaClO 2 (s)+no NO 2 +NaClO 3 (s)+nacl(s) (1) The generated NO 2 further reacts with NaClO 2 (s) to produce OClO through the reaction (2): 3NaClO 2 (s)+no 2 NaClO 3 (s)+nacl(s)+nano 3 (s)+oclo (2) OClO also can react with NO to give rise to the formation of ClO, Cl and Cl 2 via the reaction channels of (3), (4) and (5) [6], OClO+NO NO 2 +ClO (3) Cl+Cl Cl 2 (5) These chlorine-containing species of ClO, Cl and Cl 2 can significantly oxidize Hg 0 to HgCl 2 and HgO. However, we did not confirm whether the removed Hg 0 by injecting NaClO 2 (s) was exactly 40 µg Nm 3 as shown in Fig. 4. When SO 2 presents with Hg 0 in flue gas, it can interfere with the detection of Hg 0, because it also absorbs the light of 253.7 nm used in CVAAS [7]. Typically, solutions containing NaOH or Na 2 CO 3 have been used to remove SO 2 [8]. Solid NaOH granules also have been used [9]. Although the flue gas of an iron-ore sintering plant contains about 175 ppm of SO 2 as listed in Table 1, we did not employ such a system to remove acidic gas of SO 2, because NaClO 2 (s) and Cl 2 can be dissolved in solutions to result in oxidizing Hg 0. The solid NaOH granules can also absorb Hg 0. Therefore, the Hg 0 concentration of about 10 µg Nm 3 shown in Fig. 4 originates from the signal of SO 2 contained in the flue gas. Since we cannot overcome such an interference of SO 2 at the present stage, we have planned to utilize a gold amalgamation method equipped with cold vapor atomic fluorescence spectrometry. It is difficult to obtain the oxidized weight of Hg 0 related to the loaded weight of NaClO 2 (s) in these experimental conditions containing just 50 µg Nm 3, because Hg 0 is oxidized completely, which indicates that the injected amount of NaClO 2 (s) is too much as compared to that of Hg 0 in flue. Under the present experimental conditions, there are two possible methods to obtain the oxidized weight of Hg 0 related to the loaded weight of NaClO 2 (s). One is to increase the concentration of Hg 0 and the other is to decrease the feeding rate of NaClO 2 (s). The minimum feeding rate of NaClO 2 (s) is 0.05 g Nm 3 in our screw feeder, implying that decreasing the feeding ClO+NO NO 2 +Cl (4) Fig. 4. Temporal profile of Hg 0 concentration obtained by the injection of NaClO 2 (s) at 50 µg Nm 3 of Hg 0. Fig. 5. Oxidation of Hg 0 by NaClO 2 (s) injection. (a) Temporal profile of Hg 0 concentration. (b) Hg 0 oxidation efficiency as a function of weight of injected NaClO 2 (s). Error bars represent the standard deviation of Fig. 5(a) for the measurement duration of about 50 min. March, 2011

Mercury oxidation 811 rate is difficult. Therefore, we increased the concentration of Hg 0 to 260 µg Nm 3 (Fig. 5). At first, 0.1 g Nm 3 of NaClO 2 (s) was introduced into the tubular flow reactor. The Hg 0 concentration began to drop suddenly and reached 100 µg Nm 3 (Fig. 5(a)). As the injection weight of NaClO 2 (s) was increased to 0.18 g Nm 3, about 90% of Hg 0 oxidation efficiency was achieved. When the injection weight of NaClO 2 (s) was further increased to 0.36 g Nm 3, the oxidation efficiency of Hg 0 was achieved to be over 92% (Fig. 5(b)). Based on these experimental results, we obtained the oxidized weight of Hg 0 related to the loaded weight of NaClO 2 (s), i.e., 1026 (±333) (µg-hg 0 ) (g-naclo 2 (s)) 1. The amount of NaClO 2 (s), for example, used in 1 million Nm 3 hr 1 is calculated to be about 936 kg day 1 (1,403 L day 1 ) for 40 µg Nm 3 of Hg 0 oxidation, which was estimated from the oxidized weight of Hg 0 related to the loaded weight of NaClO 2 (s). Based on this observation, we concluded that the simple injection of powdered NaClO 2 (s) into the flue gas has a potential to achieve over 90% Hg 0 oxidation in practical application. The iron-ore sintering flue gas contains many other gas components which can influence the oxidation of Hg 0. Therefore, we investigated their effect on the oxidation of Hg 0 by using a laboratory scale of the experimental system. Since the overall experimental system of laboratory scale was described in detail elsewhere [3], only a general outline of the scheme was inset in Fig. 6. Initially, the effect of SO 2 on the Hg 0 oxidation was investigated in this study. 1.2 g of NaClO 2 (s) was packed within the packed-bed reactor for which the temperature was set to 130 o C and then only Hg 0 (260 µg Nm 3 ) in 2.6 L min 1 N 2 balance was introduced to the reactor. As shown in Fig. 6, no oxidation of Hg 0 occurred. As soon as 15 ppm SO 2 was introduced into the packed-bed reactor, Hg 0 oxidation occurred suddenly to give about 70% of the oxidation efficiency. With further increase of the addition of SO 2 to 35 ppm, the complete oxidation of Hg 0 was obtained. Although the insight into the oxidation mechanisms cannot be verified well presently, this result demonstrated that SO 2 can enhance greatly the oxidation of Hg 0. We also investigated the effect of H 2 O, CO, CO 2 and O 2 on the Hg 0 oxidation and observed little enhancement of Hg 0 oxidation within experimental errors; the concentration of each gas component was increased from 0 to 200 ppm with five loading steps. Upon the basis of these results, we concluded that the most important species influencing the oxidation of Hg 0 is SO 2, rather than H 2 O, CO, CO 2 and O 2. As can be seen in Figs. 4 and 5(a), the concentration of Hg 0 was increased when the injection of NaClO 2 (s) was stopped. However, the time for the Hg 0 concentration to reach the initial value of Hg 0 concentration took about 30 min. Considering the residence time of the flue gas passing the reactor (0.33 s), the accumulated NaClO 2 (s) on the inner surface of the reactor has caused the slow increase of Hg 0 concentration. Although we did not use the particulate control equipment in the present stage, it must be used in the case of a larger system than the present one to prevent the release of the NaClO 2 (s) into the atmosphere. A bag house as a particulate control equipment can provide better interaction between gas and NaClO 2 (s) due to the accumulation of the NaClO 2 (s) on the surface of the bag house. If so, installing a bag house gives rise to reducing the amount of NaClO 2 (s), which is necessary to oxide Hg 0. Therefore, we feel that further studies by employing a bag house are essential to extract the required weight of NaClO 2 (s) in a practical application. CONCLUSIONS Effects of the NaClO 2 (s) injection on the oxidation of Hg 0 were evaluated experimentally in a bench scale tubular flow reactor where the flue gas emitted from iron-ore sintering plant of steel making works is used. This study demonstrated that the direct injection of NaClO 2 (s) within flue gas can be applicable for Hg 0 emission control for a practical application. In addition, we feel that, as a next step, a long-term reliable test of this process using a bag house at a low Hg 0 concentration (below 50 µg Nm 3 ) is necessary. The following conclusions were obtained by this study: (1) Hg 0 oxidation efficiency of 90% was obtained at the feeding rate of 0.18 g Nm 3 NaClO 2 (s), which corresponds to the oxidized weight of Hg 0 related to the loaded weight of NaClO 2 (s) being 1026 (±333) (µg-hg 0 ) (g-naclo 2 (s)) 1 ; (2) SO 2 species contained in flue gas accelerated the oxidation of Hg 0, whereas CO, CO 2, H 2 O and O 2 had little effect on the Hg 0 oxidation; (3) The accumulated NaClO 2 (s) inside the tubular reactor enhanced the oxidation of Hg 0, implying that installing a bag house will reduce the required amount of the NaClO 2 (s) injection for Hg 0 oxidation. ACKNOWLEDGEMENTS Fig. 6. Effect of SO 2 on Hg 0 oxidation by NaClO 2 (s). These data were obtained at the laboratory-scale experiment using packed bed reactor. The inset describes the experiment setup. More detailed experimental system is described in our previous studies [3]. Experimental conditions: total flow rate= 2.6 L min 1, temperature=130 o C, weight of packed NaClO 2 (s)=1.2 g, N 2 balance. This work was supported by the Power Generation & Electricity Delivery (20091020100080) of the Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant funded by the Korea government Ministry of Knowledge Economy. REFERENCES 1. W. H. Schroeder and J. Munthe, Atmos. Environ., 32, 809 (1998). Korean J. Chem. Eng.(Vol. 28, No. 3)

812 Y. Byun et al. 2. J. M. Pavlish, E. V. Sondreal, M. D. Mann, E. S. Olson, K. C. Galbreath, D. L. Laudal and S. A. Benson, Fuel Process. Technol., 82, 89 (2003). 3. Y. Byun, K. B. Ko, M. Cho, W. Namkung, K. Lee, D. N. Shin and D. J. Koh, Environ. Sci. Technol., 43, 5054 (2009). 4. Y. Byun, K. B. Ko, M. Cho, W. Namkung, D. J. Koh, K. Lee, I. P. Hamilton and D. N. Shin, Environ. Sci. Technol., 44, 1624 (2010). 5. Y. Byun, K. B. Ko, M. Cho, W. Namkung, D. N. Shin, J. W. Lee, D. J. Koh and K. T. Kim, Chemosphere, 71, 1674 (2008). 6. Z. Li, R. D. Wuebbles and N. J. Pylawka, Chem. Phys. Lett., 354, 491 (2002). 7. H. Okabe, Photochemistry of small molecules, John Wiley & Sons, New York (1978). 8. H. K. Choi, S. H. Lee and S. S. Kim, Fuel Process. Technol., 90, 107 (2009). 9. S. Straube, T. Hahn and H. Koeser, Appl. Catal. B, 79, 286 (2008). March, 2011