Item 2.3 Unit pricing GC to provide a square foot unit cost for material and labor to replace plywood decking beneath new concrete walkway slab.

Similar documents
OAK TREE LIQUOR STORE

ADDENDUM # 2. - Page 1 of 2

Exterior Elevated Elements Inspection Guidelines

Residential Building Inspections

UNIVERSAL BRACKET. Shown in red color for illustration purposes. Bracket can be painted to match panels.

WeatherSmart Air Barrier Installation Guide

TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

GAF EnergyGuard Polyiso Wall Sheathing

SECTION 07530CP EPDM MEMBRANE ROOFING

Aqua Coast Engineering

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

B.01. Lincoln Property Company 100 Lowell Road North Reading, MA 01864

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

The better way to build TM. Installation Manual NAILBASE PANELS

J.DAVID POUNDER LIMITED CONSULTING ENGINEER AND ARCHITECT

FirstEnergy Program Overview

Building Enclosure Detailing for Balconies

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

HIGHLANDVIEW CEMETERY CHAPEL

Building Enclosure Detailing for Balconies

DECK CONSTRUCTION REQUIREMENTS

PROJECT INFORMATION PROJECT NUMBER 1706 SINGLE DETACHED DWELLING - RENO 4208 VARMOOR ROAD NW CALGARY ALBERTA

ROME ART AND COMMUNITY CENTER

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

EXW3 EXISTING DOWEL NEW FOOTING TO EXISTING WALL WITH 3-15M DOWELS, DOWEL THE NEW

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

WICOMICO COUNTY BOARD OF EDUCATION

Commercial Flashing Details

The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits

THE CITY OF WALTHAM MASSACHUSETTS PURCHASING DEPARTMENT PHASE III RENOVATIONS TO THE FORMER BANKS SCHOOL ELDERLY HOUSING CONDOMINIUMS AND CONDOMINIUMS

WELCOME HOME VETERANS SHELTER 2112 BUSINESS LOOP 70 EAST COLUMBIA, MISSOURI PWA #201430

FACE CFP - HORIZONTAL PANELS - OPTION 'B'

PORCH PLAN. Existing House. New Porch. Page A.1. Boxed Beams. 5/4x6 Cedar Decking. Roof Overhang. Wood Columns. Hip Roof. Step

Distances are not shown to scale. Existing porch. Community. Building. Distances are not shown to scale

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

Insulation manufacturer to submit dew point analysis free of charge for typical wall section. Analysis by:

Cowhorn Residence. PHnw 2017 Cowhorn Residence

Fixed Skylight / Fixed Multiple Skylight Milgard Aluminum Window

ADDENDUM NO Refer to Specifications Section Alternates. Clarifications to alternate descriptions are as follows:

RESIDENTIAL INSULATED SHEATHING COMFORTBOARD. Installation Guide

Multi-Institutional Academic Health Science & Research Center Evansville, IN

RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE. Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD 80

Carpenter Level 2 Rev. September 2017

Meriter Heights Renovations Madison, Wisconsin

SECTION THERMAL INSULATION

Henri Fennell, CSI/CDT ABX 2015

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

Building Enclosure Details and Assemblies for Wood-Frame Buildings

TABLE OF CONTENTS Updated 1/2014 SECTION TITLE DATE

ELEVATION FOR DETAIL REFERENCE ONLY

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 440 / 533 WEST MAIN STREET TUPELO, MS / FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON

University of Colorado Colorado Springs. National Cybersecurity Center Roof Replacement Package CSNA Project Number

T T LEGAL DESCRIPTION: LEGEND X FOUND MONUMENT AS NOTED A.M. ~ AS MEASURED IN FIELD REC. ~ DEED OR PLAT DISTANCE PL ~ PROPERTY LINE FF ~ FINISHE

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

2001 COMPANY. WIND BLOWN DEBRIS RESISTANT ROOF ASSEMBLIES Hurricane 140 Mph And Tornado 250 Mph Wind Blown Debris

Subtotal - Category 2 $ 1, $ 1, Landscaping and Fence - By Field Outdoor Spaces (

Questions and Answers Construction of New Amenities At Folly Beach County Park

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

REBECCA LG BOSTICK, ARCHITECTS, INC

Building Construction and Water Intrusion

PG&E BUILDING AT 215 MARKET STREET

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

SECTION 1 - ETHYLENE-PROPYLENE-DIENE-MONOMER (EPDM) ROOFING

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

ROOF DETAIL RD-16 CONSTRUCTION DOCUMENTS - PHASE / PENNSYLVANIA HOUSING FINANCE AGENCY/ MAY 22, 2017 MURRAY ASSOCIATES ARCHITECTS, P.C.

KORA_Req._for_Eng._Studies_on_Stouffer_Apts. KU Reference No

SECTION RESILIENT SHEET FLOORING

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

QUEEN ALEXANDRA COMMUNITY CENTRE

ADDENDUM NO. 1. Kapuskasing District High School Interior Upgrades. ADDENDUM NO. 1 November 9, 2018

Table of Contents. List of Drawings

Installation Guidelines VBC Products

SPECIFICATIONS Section Cantilevered Walkway Cover

DIVISION 7 - THERMAL AND MOISTURE PROTECTION

LIQUID RUBBER INDUSTRIES ENGINEERING SPECIFICATIONS FOR ENGINEERS AND ARCHITECTS. Diagram 1: Standard Membrane Continuation 150 mm Overlap

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

SGN+A Planning Architecture Landscape Architecture

PLATON FOUNDATION WRAP

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

ADDENDUM NO. 2 Consisting of 3 pages and Attachments

Overall Existing Conditions Summary

SAN FRANCISCO UNIFIED SCHOOL DISTRICT 2006 PROPOSITION A BOND PROGRAM 300 SENECA NEW ACADEMIC CAMPUS ADDENDUM NO. 1

4615 E. State Street Suite 206 Rockford Illinois /


THE SPENCER RESIDENCE J&S ARCHITECT

SECTION SELF-ADHERING SHEET FLASHING

CONSTRUCTION SUMMARY REPORT

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

WCU ALUMNI TOWER MASONRY & ENVELOPE REPAIRS

RE: Pacific Shores VIS Block Second Floor Walkway Structural Review

11/09/2018 LBP licence classes

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

10 EXTREME BASEMENT PANELS

Transcription:

Willow Glen Housing Repairs Project #9-59 Addendum Item. Change to bid date The bid date will be extended to March 8, 09, :00pm at the Housing Authority of Columbus Central Office,000 Wynnton Road Columbus, Georgia 3906 Item. Clarifications and additional information from the Pre-bid conference. GC s will not be allowed to use power from the individual apartment units, but they can use the House Electrical Panel GC s will be required to provide their own portable toilet facility. Construction personnel will not be allowed to use the owner s restroom facilities. The housing authority s typical restriction of work hours on renovations will NOT be applied to this project. Construction may work extended workdays and on weekends in coordination with the owner for site access and control. The lower panels of cement fiber board siding at the second-floor units will require removal to extend waterproofing membrane vertical leg and tie into walls existing air and moisture barrier to provide a weather tight enclosure. GC s to include price for repairing cement fiber board installation after demolition and painting the entire front façade of each building to match current paint scheme. As previously stated in the project narrative, each building will have a two-week period where residents will be temporarily housed off site. It is the owner s desire to have the existing structural elements removed, new structural system and stairs installed as well as the second-floor concrete balcony poured and cured for traffic with in that two week window for each unit. Guardrail and handrails must be installed at that time as well prior to residents returning to units. The additional scope of work including repair of siding, painting, cement fiberboard installation over wood structure elements, and rebuilding of deck privacy screens may occur after this two-week window. GCs are to provide an add alternate to paint each entire apartment building based on the current color scheme. See existing construction elevation sheet for take off information. Construction Document A3. from original building construction provided. Note, owner took a deductive alternate at the time of construction, Unit 5 shown on the original document site key is only 3 units wide. Pictures of existing paint scheme for reference attached. Regarding the wood structural option, where the wood beams penetrates the existing wall, GC will remove a sufficient portion of siding to flash the opening and provide water tight transition of the wall air and moisture barrier system (building wrap currently installed on wall) to the air and moisture barrier of the engineered wood beam. Repair siding and paint to match adjacent. Item.3 Unit pricing GC to provide a square foot unit cost for material and labor to replace plywood decking beneath new concrete walkway slab. Item.4 Add alternate - high performance paint at steel structural option Ninth Street Suite 0 Columbus, GA 390 p. 706.57.693 f. 706.57.698 www.wrarch.com WR of Georgia, Inc.

Provide add alternate for high performance paint at the steel option. Basis of Design: Tnemec, or approved equals from Sherwin Williams or PPG o Shop Prime: Series 90Gk-97 @.5-3.5 mils DFT ( section 500 and 5500) o Field Spot Prime: Series 394 Primer @.5-3.5 mils DF (section 9600) you can put it in 9900 o Field Intermediate: Series 73 @.0-3.0 mils DFT o Field Finish: Series 07 @.0-3.0 mils DFT Item.5 Clarification to detail at wall penetration of wood beam structural system option. See AD-.4 Drawing Item.6 Revised Sheet A.. See A. Drawing Sheet revised. o Provides clarification on cladding of existing roof beam to remain. o Provides clarification on steel railing bracing at columns. End of Addendum

EXISTING WALL EXISTING WALL WRAP AIR AND MOISTURE BARRIER. OVERLAP SELF ADHERING FLASHING SELF ADHERING AIR AND MOISTURE BARRIER FLASHING TAPERED BLOCKING TO PROVIDE OF CEMENT FIBER BOARD ACROSS TOP OF BEAM -MAINTAIN MIN OF 8" GAP BETWEEN INSIDE SURFACE OF CEMENT FIBER BOARD AND AIR AND MOISTURE BARRIER AIR AND MOISTURE BARRIER ENCASING BEAM SEALANT AT PERIMETER FILL VOID AROUND PENETRATION W/ MINIMALLY EXPANDING CLOSED CELL SPRAY FOAM INSULATION WOOD BEAM WALL PENETRATION

EXISTING ROOF ASSEMBLY EXISTING ROOF ASSEMBLY COMPOSITE DRAINAGE CONCRETE SLAB, CONT. SEALANT ARCHITECTURE INTERIORS REMOVE AND DISPOSE OF EXISTING CEMENT FIBER BOARD. PROVIDE AIR AND MOISTURE BARRIER, FURRING STRIPS, AND NEW CEMENT FIBER BOARD. SEE DETAILS 3/A. FOR BEAM ENCLOSURE EXISTING FIBER CEMENT SOFFIT NEW PT 6 X 6 WOOD COLUMN REMOVE AND DISPOSE OF EXISTING CEMENT FIBER BOARD. PROVIDE AIR AND MOISTURE BARRIER, FURRING STRIPS, AND NEW CEMENT FIBER BOARD. SEE DETAILS 3/A. FOR BEAM ENCLOSURE EXISTING FIBER CEMENT SOFFIT NEW STEEL COLUMN, NEW STEEL GUARDRAIL SYSTEM NEW WOOD COLUMN NEW CONCRETE SLAB W/ WWF COMPOSITE DRAINAGE WATERPROOFING NEW ADHESIVE PRIMER REPLACE EXISTING DAMAGED PLYWOOD DECK AS NEEDED ALUMINUM T-RAIL FOR CONCRETE BALCONY BITUMINOUS PAINT ON ALL SURFACES IN CONTACT W/ CONCRETE METAL DRIP EDGE VENT STRIP FIBER CEMENT PANEL 3/8" FURRING STRIPS FLASHING TAPE SELF-ADHERING AIR AND MOISTURE BARRIER NEW WOOD BEAM, NINTH STREET SUITE 0 COLUMBUS, GA 390 P.706.57.693 F.706.57.698 STATE REGIST ERE OF GEORG I LEE MARTIN RA054 D ARCHITECT A NEW CONCRETE SLAB, NEW STEEL GUARDRAIL, PROVIDE STEEL BRACKET AT TOP AND BOTTOM RAIL, USE " LAG SCREW (PRESSURE TREATED WOOD RATED) AT WOOD COLUMN LOCATIONS NEW CONCRETE SLAB, NEW STEEL GUARDRAIL, PROVIDE STEEL BRACKET AT TOP AND BOTTOM RAIL, FULLY WELD TO COLUMN AND RAIL NEW WATERPROOFING ADHESIVE PRIMER EXISTING PLYWOOD DECK NEW RAILING POST WILLOW GLEN HOUSING REPAIRS 3 A. 0'- /" REF. ND FLR SLABS 4 A. 0'- /" REF. ND FLR SLABS NEW PT PARALLAM BEAM EXISTING WOOD JOISTS NEW STEEL BEAM, EXISTING WOOD JOISTS STABILIZE EXISTING FLOOR JOISTS NEW VENTED FIBER CEMENT SOFFIT PANELS SELF-ADHERING AIR AND MOISTURE BARRIER AIR AND MOISTURE BARRIER FIBER CEMENT TRIM FIBER CEMENT PANEL 3/8" FURRING STRIPS FIBER CEMENT VERTICAL PANEL NEW WOOD BEAM FLASHING TAPE NEW WOOD COLUMN NEW STEEL COLUMN, VENT STRIP EXISTING CONCRETE SLAB 0'-0" REF TOP OF FIN. FLR. EXISTING CONCRETE SLAB 0'-0" REF TOP OF FIN. FLR. VENTED FIBER CEMENT SOFFIT PANEL 3/8" FURRING STRIPS AIR AND MOISTURE BARRIER PRINTED: 3/6/09 @ 0:56AM A. WALL SECTION - WOOD REPLACEMENT - OPTION /" = '-0" A. WALL SECTION - STEEL REPLACEMENT - OPTION /" = '-0" 3 A. ENLARGED SLAB DETAIL - WOOD STRUCTURE NEW STEEL GUARDRAIL SYSTEM /" = '-0" COMPOSITE DRAINAGE WATERPROOFING NEW ADHESIVE PRIMER REPLACE EXISTING DAMAGED PLYWOOD DECK AS NEEDED CONCRETE SLAB, CONT. SEALANT ALUMINUM T-RAIL FOR CONCRETE BALCONY BITUMINOUS PAINT ON ALL SURFACES IN CONTACT W/ CONCRETE SELF ADHERING FLASHING Project Number: 9-59 Date: 3 FEBRUARY 09 Drawn by: Revisions: 9 FEBRUARY 09 5 MARCH 09 NEW STEEL COLUMN METAL DRIP EDGE FILE NAME: J:\Job 9-0\9-59 Willow Glenn Emergency Repairs\Drawings\CAD\A. -ADDENDUM.dwg NEW CONCRETE SLAB W/ WWF COMPOSITE DRAINAGE NEW WATERPROOFING ADHESIVE PRIMER EXISTING PLYWOOD DECK NEW () WOOD LEDGER TO MATCH JOISTS STABILIZE EXISTING FLOOR JOISTS NEW VENTED FIBER CEMENT SOFFIT PANELS FIBER CEMENT TRIM 4 A. ENLARGED SLAB DETAIL - STEEL STRUCTURE /" = '-0" NEW RAILING POST NEW STEEL BEAM, Sheet Description WALL SECTIONS AND DETAILS Sheet Number A.